HomeMy WebLinkAboutInsulation This home has been professionally insulated with
• Owens Corning*
® PROPINK'L77 Loosefill Insulation
(Job Site Address)
Name
Address 1 Gk 7 a 1T
City 7 E7N(j c/Y 13,I-!+ 1-f State t'L Zip
Owens Corning' PROPINK'L77 Loosefill Insulation
Owens Corning Insulating Systems,LLC will accept no responsibility when the product is not installed in accordance with the product label.Stated R-value is provided by
installing the required number of bags at a thickness not less than the labeled minimum thickness.Installation of the required number of bags may yield more than the
specified minimum thickness.Failure by the installer to provide both the required bags and at least the minimum thickness will result in lower insulation R-value.
Specification for Open Blow Attics Attics Coverage charts are based an a nominal net bag weight of 32 lbs.
x t Nbu>Ims t 6laximarn F4{KtWt$num$ } p4raar r z
New Construction a�"" 1d1a�81mta@ed 1ldmretml 1t Cmrcrage�tfi;t�amum,€' t >�hi ` t%+r- a'?.��," rte.;t, r � � r r r` <t � i
4 kfr 176xm1ess Settled r Perfia0 to�9}Per Otip6er s Y tf tmtskd4 ta,s tert>a�r. 1 ttPdmAo-;
Retrofit
:Y'e.^L .r....<'.... . .,„,.:'C!."'.°.. 1:3.k.l�. #.-.,St 3 1...+..Mf.,L � (} yOY CeY�2gE ✓ 5
Number of bags used 13 a.75 4.75 184B 5.4 0.173 5 r , 3TlOtesc± st ,sfPerBa� !t900 '3{riper*.
Estimated R-value of 22 800 8.00 9.4 0301 in 2x4 35 125 87B 11.4 0.364
previous insulation 26 925 925 89. 112 0 15 2x4 3.5 IA5 75.7 132 0.423
30 1(150 10.50 77.0 13.0 .416 16 2x4 3.5 220 499 20.1 0.642
Area of coverage(sq.ft) 38 1325 13.25 599 16.7 0.534 22 2x6 5.5 125 559 179 0.573
Other type(s)of 44 15D0- 15.00 50.7 .7 0.631 23 2x6 5.5 135 517 19.3 0.619
insulation in attic 49 16.75 16.75 45D 2. 0.711 _ 24 2x8 6.5 175 40.0 25.0 0802
60 20.00 20.00 3K 28.0 OB95
Thickness of insulation
Cathedral Ceiling Floors
Depth of previous insulation ; 'S,� s �« ,, x x
_
r{z{-F F yNiBal t 20m4 ?Cerera90 lUnFrttBt WEyCf t x�t fntrtlGrstsLCd's Qoaib ri3[39 mt LlLttmotn(i Wetgtdc
A Yq:i f 1 $ (tSsDe[ Pclia9 ' BagsPer< (�l� m k r> k{Sj 11xr1mei5 fREW Caeru9ePers� Paz
i11;w71OC 'r ltQCtK311,a.«2A0�-..J.v(se n).,:_tUlO .tt. safry_, ;„R FY<_ w ;Ss?..�.� °� ) F.174?4fW 'lt6oce;tt.� saflJ:',s
-30 2x8_7.25 1.35 f 392 255 0.816 30 - 2.8 725 135 39.2 25.5 0B16
38 2x10 9.25 1.35 302 325 1.041 38 2x10 925 1.35 30.8 322 1.041
49 2x12 1125 1.85 185 542 x734 46 202 1125 135 253 39.6 1.266
Owens Corning'glass fiber blanket and loosefill thermal insulations,when installed per the manufacturers'coverage charts and recommendations,will provide the labeled R-value.
THE FOLLOWING PRODUCTS HAVE BEEN INSTALLED IN THIS HOUSE.
Kraft Unbeed Fog Loosefill FS-25 oef R-value Thickness No.pkgs. Cwrage Area
Ceilings 0, ❑ ❑ ❑ ❑ A-30
❑ ❑ ❑ ❑ ❑
Floors 0-" [1 13 El
❑ ❑ ❑ ❑ ❑
Walls !Y ❑ ❑ ❑ ❑ -�-/3- �t r `
❑ ❑ ❑ ❑ ❑
Basement ❑ ❑ ❑ ❑ ❑
❑ ❑ ❑ ❑ ❑
Crawl-
space ❑ ❑ ❑ ❑ ❑
❑ ❑ ❑ ❑ ❑
Attic ❑ ❑ ❑ ❑ ❑
❑ ❑ ❑ ❑ ❑ _ j�_ _ �^
Contractor Date 'Builder I/ 1171-611,P 64 Dated ZO 20'
Company Heartland Insulation&Acoustics Company
(Signature) (Signature)
Address Address
Phone Sebring, FL 33876 Phone
OWENS CORNING INSULATING SYSTEMS,LLC
ONE OWENS CORNING PARKWAY
TOLEDO,OHIO,USA 43659 Pub.No.10018804-C.Printed in U.S.A.October 2016.The color PINK is a registered
• n ® 1-800-GET-PINK' trademark of Owens Corning.0 2016 Owens Corning Insulating Systems,LLC.All
www.owenscoming.com Rights Reserved.