HomeMy WebLinkAboutCrown Windsor Roof Tile Eval 9/15/20Engineering Evaluation Report Joshua Royce, P.E.
P.O. Box 237
Report: 102106 Gladeville, TN 37071
Joshua Royce, P.E.
Date: 10/18/19
Page 1 of 2
Manufacturer: Crown Building Products of Florida, LLC
6018 SW Highway 72
Arcadia, FL 34266
Product: Windsor Flat Profiles – Concrete Roof Tile
Description of Product:
Flat profile interlocking, Class II concrete roofing tile. Roofing tiles may be mechanically
fastened, mortar-set or adhesive-set.
Submitted Technical Documentation:
1. Test Reports RT0819.03-19, RT0923.01-14, RT0923.02-14, RT0908.01-14,
RT0912.01-14 and RT1020.02-14 signed by Steven W. Warter, P.E. (FL PE 54395) of
American Test Lab of South Florida located in Fort Lauderdale, FL.
2. Quality Assurance: Keystone Certification (Etters, PA)
STANDARDS/REFERENCES:
Code Section Description of Test Standard Test Report #
2017 1507.3.5 Physical Properties ASTM C 1492-03 RT0923.01-14
RT0923.02-14
RT0908.01-14
2017 1507.3.7 Attachment
Requirements
FRSA/TRI 07320
2017 1523.6.5.2 Physical Properties TAS 112-95 RT0819.03-19
2017 1523.6.5.2 Wind Driven Rain TAS 100-95 RT0923.01-14
RT0923.02-14
RT0908.01-14
2017 1523.6.5.2.2 Static Uplift Resistance TAS 101-95 RT0912.01-14
2017 1523.6.5.2.3 Static Uplift Resistance TAS 102-95 RT0912.01-14
2017 1523.6.5.2.3 Static Uplift Resistance TAS 102(A)-95 RT0912.01-14
2017 2109.3.1.1 Freeze and Thawing ASTM C67-08 RT1020.02-14
Tile Roof Institute TAS 100, TAS 101, 102, 102(A) Membership Confirmation Current
Engineering Evaluation Report Joshua Royce, P.E.
P.O. Box 237
Report: 102106 Gladeville, TN 37071
Joshua Royce, P.E.
Date: 10/18/19
Page 2 of 2
Limitations of Use:
1. Fire classification is not part of this evaluation; refer to FBC Section 1505 or current
approved roofing material for fire rating of this product.
2. For non-HVHZ installations, installation shall comply with manufacturer's current
published installation instructions, but not less than the requirements as established in
FBC Section 1507.3 and the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile
Installation Manual, 5th edition for mechanically fastened installations.
3. For non-HVHZ installations, installation shall comply with manufacturer's current
published installation instructions, but not less than the requirements as established in
FBC Section 1607.7.3 and the mortar or adhesive manufacturer's product approval for
mortar or adhesive fastened installations.
4. See evaluation report RT0912.01-14 for attachment calculations.
Compliance:
The above listed products have been shown to demonstrate compliance with the 2017
Florida Building Code and with the Florida Department of Business and Professional
Regulation for Statewide Product Approval as per Rule 61G20-3.
Certificate of Independence:
In accordance with Rule 61G20-3, I do not have, nor do I ever intend to acquire, any
financial interest in any manufacturing company associated with this evaluation report. I
also do not have any financial interest in the manufacturing company or any company
associated with the manufacturing company.