HomeMy WebLinkAboutCompaction Test (3) Soil Nuclear Gauge Client: Project: ga— OW
Report Date:5/27/2020 Arthur Rutenburg Homes PSL 17-6853.00
NP Test Method:ASTM D 6938 114 SE Via Lago Garda Arthur Rutenburg Homes 2017-2018 Master
RUno g
A reement
Port SL Lucie Port St.Lucie, FL 34952
FSPECA#4930 Various Locations
607 NW Commodity Cove FL
Port St.Lucie,FL 34986
Phone:772-924-3575 1 Fax:772-924-3580
Test Results
Optimum Maximum In Place In Place Probe Min/Max
Retest Test Soil Moisture Dry Density Moisture Dry Density Depth Percent Comp.
Test# Of Date Proctor ID Method Classification N (pcf) %) (pan) (in) Compaction %) Remark
97 4/17/20 P-3 N/A 11.8 110.1 11.8 108.3 12 98 95/105 Pass
98 4/17/20 P-3 WA 11.8 110.1 12.4 107.8 12 98 95/105 Pass
99 1 1 4/17/20 P-3 N/A 11.8 110.1 12.4 107.4 1 12 98 95/105 Pass
100 1 5/8/20 1 P-3 I Y—N/A 1 11.8 110.1 11.8 108.4 1 12 98 95/105
101 5/8/20 P-3 N/A 11.8 110.1 12.1 107.5 12 98 951105 Pass
102 5/8/20 P-3 NIA 11.8 110.1 11.8 107.9 12 98 95/105 Pass
Test Information -
Gauge
Test# Test Location Elevation Reference Make/Model/SN/Calibrated Field Technician
97 Below Slab Grade:7683 Pelican Pointe,Port St Lucie,House Pad,Northeast Comer 1-2' Troxier/T3430125092/ Fevrius,Carlo
of Pad..
98 Below'Slab Grade:7683 Pelican Pointe,Port St Lucie,House Pad,Center of Pad. 1-2' Troxler/T3430/25092/ Fevrius,Carlo
99 Below Slab Grade:7683 Pelican Pointe,Port St Lucie,House Pad,Southwest Corner 1-2' Troxler/T3430 125092/ Fevrius,Carlo
of Pad.
100 - Below Slab Grade:7683 Pelican Point Drive,Port St Lucie,Northwest Comer of Pad. 0-11, Troxler/T3430 125092/ Fevrius,Carlo
101 Below Slab Grade:7683 Pelican Point Drive,Port St Lucie,Center of Pad. 0-1• Troxler/T3430/25092/ Fevrius,Carlo
102 Below Slab Grade:7683 Pelican Point Drive,Port ST eas rner o a Troxler/T3430/25092/ Fevrius,Carlo
Remarks Comments
Pass:Tests results Comply with specifications Tests are'Direct Transmission'(Method A)unless probe depth is noted es
e calibration data on file
100,101 102:St/ (
Stem Wall:North,South,East&West Footing Center. `��`\`th the testing agency. `NN I K! '/ i,
0-1,1-2'HCP=70+,>95%Compaction,PASS.HCP tests are �0.• "' •nV
emDiricaliv correlated to the relative density of the soil. �,�CENgF'•.
No 632
li Kent, F.E. �_-
1 rt ssior�lat£f��)Reer.# �48
{Fa cto?.• 'GIX
�0NAL
Test Reports shall not be reproduced,except in full,without the written approval of GFA International Inc. Page 1 of 1
Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.