HomeMy WebLinkAboutCompaction Test (3) Soil Nuclear Gauge Client: Project: ga— OW Report Date:5/27/2020 Arthur Rutenburg Homes PSL 17-6853.00 NP Test Method:ASTM D 6938 114 SE Via Lago Garda Arthur Rutenburg Homes 2017-2018 Master RUno g A reement Port SL Lucie Port St.Lucie, FL 34952 FSPECA#4930 Various Locations 607 NW Commodity Cove FL Port St.Lucie,FL 34986 Phone:772-924-3575 1 Fax:772-924-3580 Test Results Optimum Maximum In Place In Place Probe Min/Max Retest Test Soil Moisture Dry Density Moisture Dry Density Depth Percent Comp. Test# Of Date Proctor ID Method Classification N (pcf) %) (pan) (in) Compaction %) Remark 97 4/17/20 P-3 N/A 11.8 110.1 11.8 108.3 12 98 95/105 Pass 98 4/17/20 P-3 WA 11.8 110.1 12.4 107.8 12 98 95/105 Pass 99 1 1 4/17/20 P-3 N/A 11.8 110.1 12.4 107.4 1 12 98 95/105 Pass 100 1 5/8/20 1 P-3 I Y—N/A 1 11.8 110.1 11.8 108.4 1 12 98 95/105 101 5/8/20 P-3 N/A 11.8 110.1 12.1 107.5 12 98 951105 Pass 102 5/8/20 P-3 NIA 11.8 110.1 11.8 107.9 12 98 95/105 Pass Test Information - Gauge Test# Test Location Elevation Reference Make/Model/SN/Calibrated Field Technician 97 Below Slab Grade:7683 Pelican Pointe,Port St Lucie,House Pad,Northeast Comer 1-2' Troxier/T3430125092/ Fevrius,Carlo of Pad.. 98 Below'Slab Grade:7683 Pelican Pointe,Port St Lucie,House Pad,Center of Pad. 1-2' Troxler/T3430/25092/ Fevrius,Carlo 99 Below Slab Grade:7683 Pelican Pointe,Port St Lucie,House Pad,Southwest Corner 1-2' Troxler/T3430 125092/ Fevrius,Carlo of Pad. 100 - Below Slab Grade:7683 Pelican Point Drive,Port St Lucie,Northwest Comer of Pad. 0-11, Troxler/T3430 125092/ Fevrius,Carlo 101 Below Slab Grade:7683 Pelican Point Drive,Port St Lucie,Center of Pad. 0-1• Troxler/T3430/25092/ Fevrius,Carlo 102 Below Slab Grade:7683 Pelican Point Drive,Port ST eas rner o a Troxler/T3430/25092/ Fevrius,Carlo Remarks Comments Pass:Tests results Comply with specifications Tests are'Direct Transmission'(Method A)unless probe depth is noted es e calibration data on file 100,101 102:St/ ( Stem Wall:North,South,East&West Footing Center. `��`\`th the testing agency. `NN I K! '/ i, 0-1,1-2'HCP=70+,>95%Compaction,PASS.HCP tests are �0.• "' •nV emDiricaliv correlated to the relative density of the soil. �,�CENgF'•. No 632 li Kent, F.E. �_- 1 rt ssior�lat£f��)Reer.# �48 {Fa cto?.• 'GIX �0NAL Test Reports shall not be reproduced,except in full,without the written approval of GFA International Inc. Page 1 of 1 Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.