Loading...
HomeMy WebLinkAboutCompaction Test (2) Headquarteri in 11,345 U.S. Highway 1 *r V , At ENGINEERING PO Box.78-1'377 Sebastian, FL. 32958 40 AVL ANDTESTINGSebastian, FL. 32978 Orlando Phone: 772-589-0712 723 Progress Way SOIL COMPACTION REPORT C.A.#5693 Sanford, FL. 32771 KSMengineering.net. ASTM D 1557 and ASTM D 6938 - DATE.TESTED: April 13, 2020 KSM JOB-#: 201722-1d/DJ/cv' PERMIT#: 2002-0650-Detached Garage NUC# 404 2002-0649-House Addition CONTRACTOR: Carter's Concrete Construction Nuc Model: MC-1 Elite JOB LOCATION: 2711 S. 19th Street Nuc Serial#: 31404 Fort Pierce, Florida ITEM TESTED: First Lift TEST LOCATION PEN DRY MAX. DRY PERCENT' DEPTH OF SAMPLE READ DENSITY PROCTOR VALUE(P.C.F.) COMPACTION, . House Addition 1. 'N.E. 0"- 12" 35 108.5 111.7 97.1% 2. S.E. 37 107.2 96.0% 3. Center 37 108.5 97.1% 4=. S.W. 40 108.9 97.5% -5.:N.W. 38 107.8 96.5% --Soils Description: Brown Sand with Traces-of Shell Fragments In P.lace Moisture: 7.3 Proctor Op#imum,Moisture: 11.4% P.roctor'Max. Dry Density: P.C.F. 111.7 @ Test Locations the Density& Penetrometer reading indicate the :Degree of Compaction Meets Minimum Requirement for•Unstake'd Foundation Disclaimer: Contractor is responsible to maintain the tested area in the condition :that KSM completed the indicated passed compaction_test. KSM is not responsible if the tested area has been Julie.E. Keller, P.E. altered from the approved inspected condition. President PE#68366 5/6/2020 Proudly Serving Florida since 1990