Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Cano 2917 PA
BOS Home Log In User Registration Hot Topics Submit Surcharge Slats & Facts Publications Contact Us BCIS Site Map Links Search dbOr ( Product Approval ,T¢ . USER: Public User Product Aparoval wienu > Product or Aqplicatian Search > implication Ust > Application Detail FL # FL11602-R10 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Owens Corning Roofing and Asphalt, LLC Address/Phone/Email one Owens Corning Parkway Toledo, OH 43645 (740) 321-6345 Greg. Keeler@owenscorning.com Authorized Signature Keeler Greg Greg.Keeier@owenscorning.com Technical Representative Greg Keeler Address/Phone/Email 2790 Columbus Road Granville, OH 43023 (740) 321-6345 greg.keeler@owenscorning,corn Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida license PE-59166 Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity Quality Assurance Contract Expiration Date 12131/2020 Validated By John W. Knezevch, PE " Validation Checklist - Hardcopy Received Certificate of Independence FL11602 R10 -Oi� I 2019 92C!Q NIEMINEN•pgf Referenced Standard and Year (of Standard) Standard Year ASTM D1970 2015 ASTM D226 (physicals) 2009 ASTM D4798 2011 FRSA/TR1 April 2012 2012 TAS 117(B) 1995 UL1897 2012 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/17/2019 Date Validated 10/17/2019 Date Pending FBC Approval 10/2012019 Date Approved 12/10/2019 Summary of Products ¢ FL # Model, Number or Name Description — 1 02.1 T manta lum Roof Underlayments Synthetic sheet -type roof underlayments Limits of Use Installation Instructions fft Approved for use in HVHZ- No EL11602 R10 II 2019 10 FINAL ER F1_11602-910 p_ f Verified By: Robert Nieminen PE-59166 Approved for use outside HVHZ: Yes Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure- +N/A/-45 Evaluation Reports i other: 1.) The design pressure noted herein pertains to use of Fl 11602 Rio AE 2D19 10 FINAL ER FL11602-R10.pdf Created by Independent Third Party: Yes a specific underlayment system beneath foam -on the sytsems. Refer to ER Section 5,6.3 for details. 2.) Refer to ER Sections 5 I and 6 for other Limits of Use. Contock Us :: 2601 Blair Stone Road, Tallahass� FE 2= Phone: $50-487-1824 The State of Florida is an AAJEe0 employer. right 2Qp7-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Rfunrl Statement Under Florida law, email addresses are public records. If you do not want your a -mail address released in response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395- *Pursuant to Section 455.275(i), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please dick her Product Approval Accepts: ( Credit Card Safe NEMOI etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY Owens Corning Roofing and Asphalt, LLC One Owens Corning Parkway Toledo, OH 43659 (740) 321-6345 Evaluation Report 111980.11-08-R11 FL11602-it10 Date of Issuance;11/03/2008 Revision 11:10/17/2019 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6u' Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Titanium""' Roof Underlayments LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "MEMO j etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the jots site at the request of the Building Official. This Evaluation Report consists of pages 2 through S. Prepared by: >, Robert J.M. Nieminen P.E. ,SFr .. Tf The facsimile seal appearing was authorized by Robert Florida Registration No. 59I66, Florida ©CA ANE1983 . 'f✓ ,;, ; s4' ` Nieminen, P.E. on 10/17/2019. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE; 1. NEW ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEW ETC, LLC is not Owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. Q2018 NEMO ETC, LLC ONEMOJetc. ROOFING COMPONENT EVALUATION: I. •P Product Category: Roofing Sub -Category: U nderlayment Compliance Statement: Titanium"' Roof Underlayments, as produced by Owens Corning Roofing and Asphalt, LLC, have demonstrated compliance with the intent of the following sections of the 61h Edition (2017) Florida Building Code through testing in accordance with applicable sections the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS' Section Pro a Standard Year 1504.11 Wind Uplift UL 1897 2012 1507.1.1, R905.1.1 Exception Unrolling, Breaking Strength, Pliability ASTM D226 2009 1507.1.1, R905.1.1 Exception Tear Strength ASTM D1970 2015 1507.1.1, T1507.1.1,1507.2.9.2 Physical Properties ASTM D1970 2015 1507,3.3 Physical Properties FRSA/TRI April 2012 (04-12) 2012 TAS 110 Accelerated Weathering ASTM D4798 2011 TAS 110 Pull -through resistance TAS 117(8) 1995 REFERENCES - Entity Examination Reference Bate ERD (TST6049) Physical Properties 115010.04,09 04/29/2009 ERD (TST6049) Physical Properties 115010.05.10 05/14/2010 ERD (TST6049) Physical Properties 135520,06.11 06/15/2011 ERD (TST6049) ASTM D226 138010.08.11 08/11/2011 ERD (TST6049) Wind Uplift 135520.08.11-1 08/12/2011 ITS(TST1509) ASTM D226 311801000Q-003 04/26/2007 ITS(TST1509) ASTM D226 3130639COQ-002A 08/21/2007 ITS (TST1509) Physical Properties 3126617COQ-005 10/31/2007 ITS(TST1509) ASTM D226 101823107COQ-011 01/23/2015 ERD (TST6049) Physical Properties (NH) 4j-OC-19-SSUDL-01.A 06/14/2019 Owens Corning Product equivalency Declaration 06/18/2018 PRI (TST5878) ASTM D1970 OCF-341-02-01 09/20/2017 PRI(TST5878) ASTM D1970; Tear strength OCF-331-02-02 10/03/2017 PRI (TST5878) ASTM D1970; Tear strength OCF-332-02-02 10/03/2017 PRI(TSTS878) ASTM D1970; Tear strength OCF-334-02-02 10/03/2017 PRI (TST5878) FRSA/TRI April 2012 (04-12), partial OCF-343-02-01 11/09/2017 PRI (TST5878) ASTM 04798 OCF-341-02-01 11/27/2017 PRI (TST5878) TAS 117(B);Pull-through OCF-422-02-02 04/03/2018 PRI (TST5878) FRSA/TRI April 2012 (04-12), partial OCF-425-02-01 08/13/2018 PRI (TST5878) ASTM D226 / ASTM D4798 OCF-331-02-01 R1 05/07/2019 PRi (TST5878) ASTM D226 /ASTM D4798 OCF-332-02-01 R1 05/07/2019 PRI (TST5878) ASTM D226 / ASTM D4798 OCF-334-02-01 R1 05/07/2019 PRI (TST5878) UL1897 1378TO02 07/10/2019 PRI (TST5878) Tensile adhesion OCF-507-02-01 08/13/2019 ITS (QUA1673) Quality Control ITS Listings Current ITS (QUA1673) Quality Control Service Confirmation 09/30/2017 MEMO ETC, LLC Evaluation Report 1119$0.11.08-fill Certificate offiuthorizotion ff3M5 6"" EDITION (2017) FBC NON-HVHZ EVALUATION FL11602-R10 Titanium Roof Underlayments Revision 21; 20/27/2019 Page 2 of a NEM01 etc. Product Specification Plant(s) Description 4.1 Titanium"' PSU-30 ASTM D1970 Dubai, UAE & unreinforced polymer modified bitumen material adhered and FRSA/TRl Brentwood, NH to the underside of a polymer -coated, synthetic woven April 2012 sheet. The underside is backed with a release film. Unit weight 24lbs/square 42 Titanium'UDL-l5 FBCl607.1.1 Qingdao, China synthe1icshe�—e-'odedaymrntunmpdsedofawoven &R9O5.1.1 core coated onone side with apolymer coating. Unit (Exception) weight Z.5}bs./squmm 4.3 Titanium1mVDL80 FHCl5O7.I.1 Mission, BC, synthetic sheet -type ondadaymentcomprised nfawoven &8985.1.l Canodo& core coated uuboth sides with apolymer coating. Unit (Exception) Qingdao, China weight 4.0ibu./aquae 4.4 TitaniumT11UDL-50 F8[1507.1.2 Mission, BC, synthetic sheet -type vnder|aymentcomprised ufuwoven &K9OlI'1 CanadaQ core coated onboth sides with apolymer coating. Unit (Exception) [UnQdao'China weight 4.7|6o./square 5.1 This is a building code evaluation, Neither NEW ETC, LLC nor Robert Nleminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report isnot for use inFBCHVMZjurisdictions. 6.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 litanivm`° 8uofUndedayments may be used with any prepared roof cover where the product is specifically referenced within FBCapproval documents. Ifnot listed, arequest may bnmade tnthe Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. B Allowable Roof Covers: TAsLE I: RooFC0VER OPTIONS Asphalt Wood Shakes Underlayment Shingles Nail.OnTile foam -On 711a Metal Shingles State �,fitaniurn PSU- - 30 Yes Yes Yes Yes Yes Yes Titanium UDL-25 Yes No No Yes Yes Yes Yes Yes 4ftaniurn UDL-30 Yes (Base Sheet in 2-ply (Basee Sheet in 2-ply Yes Yes Yes system) system) Titanium UDL-50 Yes No No Yes Yes Yes NEW ETC,uz Evaluation Report u1980,#.08-Ril c°Tifaptc*A.momammmo45s a�EDITION (2uz)FSCwom-HvxzEVALUATION e11602-Rm Titanium Roof onornayments Revision 1x.u01x7/20my Page sofu Ea I etc. 5.5.1 "Foam -On Tile" is limited to use of following Approved the adhesives / underlayment combinations. 5.6 5.6.1 TABLE IA: ALLOwAB1,E TILE Ao"EstvE / UNDERLA`iMENT COMBINATIONS' 1 Underlayment Adhesive Florida Product Approval Titanium PSU-30 DUPONT Tile Bond— FL22525 1CP Adhesives Polyset' AH-160 FL6332 ICP Adhesives Polyset' RTA-1 FL6276 Allowable Substrates (for self -adhering): TABLE 2: SUBSTRATE OPTiONS Underlayment Primer Substrates Titanium PSLI-30 (Optional) ASTM D41 plywood None ASTM D226 felt ASTM D41 ----. Titanium UDL-30 None Titanium UDL-30 (inverted) #1 #2 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on the applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRl April 2012 (04-12), Appendix A, Table 1A or F8C 1609 for determination of design wind loads. Maximum Design Pressure = -45 Ps€: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Flaying Jurisdiction. Primer: (Optional) ASTM 041 Underlayment: One or two plies, Titanium PSU-30, self -adhered and back -nailed max. 6" o.c. with 12 ga. galvanized annular rink shank nails through 32 ga., 1-5/8-inch diameter tin caps in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements. Maximum Design Pressure = -30 psf*: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction, Base Sheet: Titanium UDL-30 (inverted) Fasteners: 12 ga, annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min. 32 ga., 1-5/8" diameter tin caps Spacing: 6-inch o.c. at 4-inch wide side laps and 12-inch o.c. at three (3), equally spaced center rows. Primer: ASTM D41 primer required at all tin -caps. Underlayment: One or two plies, Titanium PSU 30, self -adhered and back -nailed max. 6" o.c. with 12 ga. galvanized annular rink shank nails through 32 ga., 1-5/8-inch diameter tin caps in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements. 'Refer to rile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEIVIG ETC, LLC Evaluation Report 111980.i1.08-Rif certificate OfAufhonzotion #32455 6T4 EDITION (2017) FBC NON-4VH2 EVALUATION FL11602-silo Titanium hoof Underlayments Revision 11: 10/1712019 Page 4 of 8 t #3 Maximum Design Pressure = -30 psf*: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30 (printed side up) Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min. 32 ga., 15/3" diameter tin caps. Spacing: 6-inch o.c_ at 4-inch wide side laps and 12-inch o.c. at three (3), equally spaced center rows. Primer: ASTM D41 primer required over printed side of UDL-30. Underlayment: One or two plies, Titanium PSU 30, self -adhered and back -nailed max. 6" o.c. with 12 ga. galvanized annular rink shank nails through 32 ga., 1-5/8-inch diameter tin caps in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements. ##4 Maximum Design Pressure = -45 psf*: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30 (inverted) Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min. 32 ga.,1-5/8" diameter tin caps Spacing: 6-inch o.c. at 4-inch wide side laps and 8-inch o.c, at three (3), equally spaced center rows. Primer: ASTM D41 primer required at all tin -caps. Underlayment: One or two plies, Titanium PSU 30, self -adhered and back -nailed 6" o.c. with 12 ga. galvanized annular rink shank nails through 32 ga., 1-5/8-inch diameter tin caps in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements. #5 Maximum Design Pressure = -45 psf*: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30 (printed side up) Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min. 32 ga.,1-5/8" diameter tin caps. Spacing: 6-inch o.c. at 4-inch wide side laps and 8-inch o.c. at three (3), equally spaced center rows. Primer: ASTM D41 primer required over ,printed side of UDL-30. Underlayment: One or two plies, Titanium PSU 30, self -adhered and back -nailed 6" o.c. with 12 ga. galvanized annular rink shank nails through 32 ga_, 1-5/8-inch diameter tin caps in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements. 5,6.4.1 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TR1 April 2012 (04-12), Appendix A, Table IA. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.7 Exposure Limitations: Titanium UDL-25, Titanium UDL-30, Titanium UDL-50 or Titanium PSU-30 shall not be left exposed for longer than 180-days. NEW ETC, tic Evaluation Report 111980.11.WR11 Certificate ofAuthorization #32455 67" €DITiON {2017) F8C NON-HVHZ EVALUATION FL11602-R10 Titanium Roof Underlayments Revision 11: 10117/2019 Page 5 of 8 NIFIVIEM0 I etc. 5.8 Tile Slippage Limitations rper FRSA/TRI April 2012 t04-l2j1: When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 3: TOLE SLIPPAGE LimyrATiONS FOR DIRECT -DECK TILE iNsTALLATIoNs Underlayment Tile Profile Staging Method Maximum Slope Titanium PSU-30 Flat Max.10-tile stack 5:12 Flat Max 5-tile stack 6:12 Lugged Max.10-tile stack 4:12 Lugged Max. 5-tile stack 5.12 Lugged Max. 10-tile stack f 5 over Q 5:12 �__-.... 6. s 6.1 Titanium Roof Underiayments shalt be installed in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 Titanium"' UDL-25, Titanium UDL-30 or Titanium UDL-50: 6.3.1 Shall be installed in compliance with the requirements for ASTM D226, Type I or it underlayment in FBC Table 1507.1.1 or R905.1.1 for the type of prepared roof covering to be installed, considering the wider sheet -width. 6.3.2 Fasteners: Mechanical attachment of Titanium UDL-25 and Titanium UDL-30 is limited to ring shank roofing nails with minimum 1-inch diameter plastic caps. Mechanical attachment of Titanium UDL-50 is limited to ring shank roofing nails with minimum 3/8-inch diameter heads; ring shank roofing nails with minimum 1-inch diameter plastic caps; screws and plates; or plastic cap staples. 6.3.2.1 Code Reference: The Exception statement in FBC 1507.1.1 and F8C R905.1.1 states: ':,.except metal cap nails shall be required where the ultimate design wind speed, Vauit, equals or exceeds 150 mph." Owens Corning Roofing and Asphalt, LLC has furnished data to permit the use of 1-inch diameter plastic cap nails in lieu of metal cap nails for these applications, when the Titanium"" UDL-25, Titanium UDL-30 or Titanium UDL-50 underlayment is installed beneath mechanically fastened prepared roof covers referenced in FBC Table 1507.1.1 or R905.1.1. NEM0 ETC, LLC Evaluation Report 111980.11.08-R11 Certificate ofAuthorkation #32455 e EDITION (2017) FBC LION-HVHZ EVALUA T ION FL11602-R10 Titanium Roof Undertayments Revision 11:10/17/2019 Page 6 of 8 *NEM0I etc. 6,3.3 Slopes of 4.12 or greater: End (vertical) laps shall be minimum 6-inches and side (horizontal) laps shall be minimum 4-inches. End (vertical) laps shall be offset from course to course not less than 6 feet. Minimum attachment shall be in accordance with FBC Table 1507.1.1 or R905.1.1. When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily attached pending attachment of the battens. 6.3.4 Slopes of 2:12 to less than 4:12: End (vertical) laps shall be minimum 12-inches and side (horizontal) laps shall be minimum 25-inches. End (vertical) laps shalt be offset from course to course not less than 6 feet, Begin by fastening a 25-Inch wide strip along the eaves. Place a full -width sheet over the starter, completely overlapping the starter course. Continue upslope, maintaining minimum 25-inch side (horizontal) laps, resulting in a double -layer application. Minimum attachment shall be in accordance with FBC Table 1507.1.1 or R905.1.1. Secure end laps 4-inch o.c. When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily attached pending attachment of the battens. 6.4 Titanium'"" PSU-30: 6.4.1 Non -Tile Installations: Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Table 1507,1.1 for the type of prepared roof covering to be installed, and Owens Corning published requirements. TitaniumF"s PSU-30 shall be back -nailed in accordance with Owens Corning published installation requirements, 6.4.2 Nail -On Tile Applications: Shall be installed in compliance with the requirements for Self -Adhered Membrane underlayment set forth in FRSA/TRI April 2012 (04-12), and Owens Corning published requirements. Titanium"4 PSU-30 shall be back -nailed max. 6" o.c. with 12 ga. galvanized annular rink shank nails through 32 ga., 1-5/8-inch diameter tin caps in accordance with Owens Corning published installation requirements. Refer to Section 5.8 for tile staging limitations. 6.4.3 foam -On Tile Applications: Shall be installed in compliance with the requirements for Self -Adhered Membrane underlayment set forth in FRSA/TRI April 2012 (04-12), and Owens Corning published requirements. Titanium"' PSU-30 shall be back -nailed max. G" o.c. with 12 ga. galvanized annular rink shank nails through 32 ga., 1-5/8-inch diameter tin caps in accordance with Owens Corning published installation requirements. Refer to Table 1A for allowable tile adhesives. Refer to Section 5.6.1 for wind uplift limitations. Refer to Section 5.8 for tile staging limitations. 6.5 Titanium 2-Ply System: 6.5.1 The Titanium 2-Ply System consists of a base layer of Titanium UDL-30 (top -surface primed or sheet inverted) mechanically attached to the wood roof deck followed by Titanium PSU-30, self -adhered. 6.5.2 Non -Tile Applications: Install Titanium UDL-30 (top surface primed or sheet inverted) in accordance with Section 6.3 followed by Titanium PSU-30 in accordance with Section 6.4. NEMO ETC, LLC Evaluation Report 111980.11.08-R11 Certi�cateofAuthorizat;on#32455 67" EDITION (2017) FBC NON-HVHZ EVALUATION FL11602-R10 Titanium Roof Underlayments Revision 11:10/1712019 Page 7 of 8 NNEMO 1 etc. 6.5.3 Nail -On Tile Applications; For nail -on tile installations, install Titanium UDL-30 (top surface primed or sheet inverted) in accordance with FRSA/TRI April 2012 (04-12), using Section 6.3 as a guide, and considering the wider sheet width relative to ASTM D226 felt. Then apply Titanium PSU-30 in accordance with Section 6.4. Refer to Section 5.8 for the staging limitations. 6.5.4 Foam -On Tile Applications: For foam -on the installations, install Titanium UDL-30 (top surface primed or sheet inverted) in accordance with Section 5.6.1 herein. Then apply Titanium PSU-30 in accordance with Section 6.4 Refer to Table 1A for allowable tile adhesives. Refer to Section 5.6.1 for wind uplift limitations. Refer to Section 5.8 for tile staging limitations. BUItDING PERMIT REQUIREMEIM' As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. MANUFACTURINGPLANTS- Contact the manufacturer or the named Q4 entity for plants covered under Rule 61G20-3 QA requirements. Refer to Section 4 herein for product & production locations having met codified physical properties specifications. IF Intertek Testing Services NA Inc. -- QUA1673; (604) 520-3321 - END OF EVALUATION REPORT - MEMO ETC, LLC Evaluation Report 111980.11.08-R11 Certificare ofAutthorization #1324SS 6T" EDITION (2017) FBC NON-KVHZ EVALUATION FL11602-R10 Ttanium Roof underiayments Revision 11: 20/27/2019 Page 8 of 8