Loading...
HomeMy WebLinkAboutCompaction Test (2) Headquarters1&C IL t, ENGINESF"% PO Box 7Mailing '11 345 U%S. Highway 18-1377 Serlando bastian, FL. 32958A% ,AVL AND TESTINu SebaPhonstian, L. 2978 712 723 Progress Way C.A.#5693 Sanford, FL. 32771 KSMengineering.net April 21, 2020 KSM JOB#: 201845-1d/SH/jo CONTRACTOR: James Farley 4606 Magnolia Drive :r Fort Pierce, Florida JOB LOCATION: 4606 Magnolia Drive Fort Pierce, Florida PERMIT#: ;-2003-0125 To Whom it may concern, Enclosed, please find the nuclear density test results performed on the garage pad at the above referenced project. Should you have any question, please feel free to contact our office. APR 2 9 2020 Respectfully, 06gv `.••�.•.•••,• �PSI • 0. 68366 PE#"�3�j NAt'�,`••o' 04/21/20 IIDlttttt Email to: St Lucie Building Department; jfarley@slbt.com Proudly Serving Florida since 1990 HeadquartersPO I&CA 1 t ENGINEERI�'" Box Mailing 1.1345 USebastiaSS. Highway 1 78-1377 78 Ovando n, FL. 32958 Sebas , FL.LZ oLVL AND HUM' Ph net1an772-589-0712 723 Progress Way SOIL COMPACTION REPORT C.A.#5693 Sanford, FL. 32771 KSMengineering.net ASTM D 1557 and ASTM D 6938 DATE TESTED: April 20, 2020 KSM JOB# : 201845-1d/SH/jo PERMIT#: 2003-0125 NUC# 528 CONTRACTOR: James Farley Nuc Model: MC-10R-P y JOB LOCATION: 4606 Magnolia Drive Nuc Serial#: MD049528 Fort Pierce, Florida ITEM TESTED: Garage Pad TEST LOCATION DEPTH PEN DRY MAX. DRY PERCENT OF SAMPLE READ DENSITY PROCTOR VALUE(P.C.F.) COMPACTION 1. S.E. 011- 1211 39 108.4 112.8 96.1% 2. Center 1140 109.0 if 96.6% 3. N.W. 39 108.9 96.5% Soil Description: Brown Sand with Shell In Place Moisture: 10.0% Proctor Optimum Moisture: 11.0% Proctor Max.Dry Density: P.C.F. 112.8 @ Test Locations the Density& Penetrometer reading indicate the Degree of Compaction Meets Minimum Requirement for Staked Foundation Disclaimer: Contractor is responsible to maintain the tested area in the condition that KSM completed the indicated passed compaction test. KSM is not responsible if the tested area has been Julie E. Keller, P.E. altered from the approved inspected condition. President PE#68366 4/21/2020 Proudly Serving Florida since 1990 Headq $1345 iS. H C ENGINEERIP� PO Box 78--11378 1'134 U'S. Highway 1 Sebas , FL. 3278 Orlando Sebastian, FL. 32958 ZV AVLAND TESTM Phone:t1an772-589-07912 723 Progress Way SOIL COMPACTION REPORT C.A.#5693 Sanford, FL. 32771 ASTM D 1557 KSMengineering.net DATE TESTED: April 20, 2020 KSM JOB#: 201845-1d/SH/jo PERMIT#: 2003-0125 CONTRACTOR: James Farley JOB LOCATION: 4606 Magnolia Drive Fort Pierce, Florida 114.0 I I I I I W E I I I I I I G113.0 i—..—..—.. ..—..—..+..—..—..� ..—..—..—j..—..—..—j..—..—..—. H T I I I I I I I I I I I PI I I I I 112.0 j_..—..—. —..—..—..— —..—..— .—..—.. —..—..—. —..—..—. C I I I I I I I I I I I F I I I I I 111.0 —..—..�..— —..T..—..—..�..—..—..�..—.. —i.—..—..—. D I I I I I I R I I I I I Y110.0 �..—..—. —..—..+..—..—.. ..—..—..�..—..—..—�..—..—..—. I I I I I I I I I I I I 109.0 �..—..—..�..—..—.. ..—..—..�..—..—..�..—..—..—� — — —, 8 9 10 11 12 13 14 Moisture-% of Dry Weight Soil Description: Brown Sand with Shell Proctor Optimum Moisture: 11.0% Proctor Max. Dry Density: P.C.F. 112.8 Julie E. Keller, P.E. President PE#68366 4/21/2020 Proudly Serving Florida since 1990