HomeMy WebLinkAboutEnergy Code:FOPM 60OA-2001
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
Residential Whole Building Performance Method A
Project Name: DRAWDY RESIDENCE Builder:
Address: Permitting Office:
City, State: Permit Number:
Owner: Jurisdiction Number:
Climate Zone: Central
1.
New construction or existing
New _
12. Cooling systems
2.
Single family or multi -family
Single family _
a. Central Unit
Cap: 24.0 kBtu/hr
3.
Number of units, if multi -family
1 _
SEER: 12.00 _
4.
Number of Bedrooms
3
b. Central Unit
Cap: 48.0 kBhOu
5.
Is this a worst case?
No -
FILE C 0 PY
SEER: 12.00
6.
Conditioned floor area (ft2)
3659 ft2
c. N/A
7.
Glass area & type
Single Pane Double Pane _
a. Clear glass, default U-factor
414.9 ft2 0.0 ft2 _
13. Heating systems
b. Default tint
0.0 ft2 0.0 ft2 _
a. Electric Strip
Cap: 16.0 kBtu/hr
c. Labeled U or SHGC
0.0 ft2 0.0 ft2
COP: 1.00
8.
Floor types
_ °
b. Electric Strip
Cap: 34.0 kBtu/hr _
a. Slab -On -Grade Edge Insulation
R=0.0, 277.4(p) ft _
COP: 1.00
b. N/A
_
c. N/A
c. N/A
9.
Wall types
_
14. Hot water systems
a. Concrete, Ext Insul, Exterior
R=4.0, 1806.1 ft2 _
a. Electric Resistance
Cap: 52.0 gallons
b. Frame, Wood, Adjacent
R=11.0, 232.0 ft2 _
EF: 0.88
c. N/A
_
b. Electric Resistance
Cap: 40.0 gallons _
d. N/A
_
EF: 0.88 _
e. N/A
c. Conservation credits
_
10. Ceiling types
_
(DR -Heat recovery, Solar
a. Under Attic
R=30.0, 3659.0 ft2 _
DHP-Dedicated heat pump)
b. N/A
_
15. HVAC credits
PT, _
c. N/A
(CF-Ceiling fan, CV -Cross ventilation,
11.
Ducts
_
HF-Whole house fan,
a. Sup: Unc. Ret: Unc. AH: Interior
Sup. R=6.0, 83.1 ft _
PT -Programmable Thermostat,
b. Sup: Unc. Ret: Unc. AH: Interior
Sup. R=6.0, 170.8 ft
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
Glass/Floor Area: 0.11 Total as -built points: 42313 PASS
Total base points: 43813
I hereby certify that the plans and specifications covered
by this calculation ar mpliance with the FI rida
Energy Code.
PREPARED BY.
DATE:
I hereby certify that this building, as designed, is in
compliance with the Florida Ener ode.
OWNER/AGENT: -«• 'D
DATE: a or
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908.
Florida Statutes.
BUILDING OFFICIAL:
DATE:
EnergyGauge® (Version: FLRCSB v3.30)
FORM 60OA-2001
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , . , PERMIT #:
BASE
AS -BUILT
GLASS TYPES
.18 X Conditioned X BSPM = Points
Overhang
Floor Area
Type/SC
Omt
Len
Hgt
Area X SPM X SOF = Points
.18 3659.0 25.78 16979.2
Single, Clear
NW
2.0
5.0
8.8
40.72
0.84
299.3
Single, Clear
W
2.0
5.0
27.6
57.68
0.81
1282.6
Single, Clear
SW
2.0
5.0
8.8
56.99
0.76
382.5
Single, Clear
N
2.0
8.0
8.0
30.19
0.94
227.0
Single, Clear
E
2.0
6.0
15.0
63.97
0.85
820.3
Single, Clear
NE
2.0
6.0
14.6
47.10
0.86
594.6
Single, Clear
N
2.0
6.0
30.0
30.19
0.90
817.9
Single, Clear
NW
2.0
6.0
14.6
40.72
0.87
518.9
Single, Clear
E
2.0
6.0
65.0
63.97
0.85
3554.6
Single, Clear
E
2.0
7.0
12.0
63.97
0.89
681.5
Single, Clear
E
6.0
8.0
45.3
63.97
0.61
1756.0
Single, Clear
NE
6.0
6.0
9.6
47.10
0.59
266.3
Single, Clear
SE
6.0
6.0
9.6
61.07
0.51
300.2
Single, Clear
W
2.0
6.0
24.0
57.68
0.85
1181.9
Single, Clear
W
16.0
8.0
48.0
57.68
0.43
1178.4
Single, Clear
W
16.0
8.0
24.0
57.68
0.43
589.2
Single, Clear
W
2.0
9.0
12.0
57.68
0.94
647.8
Single, Clear
S
2.0
6.0
15.0
48.22
0.80
577.2
Single, Clear
S
2.0
8.0
8.0
48.22
0.87
335.1
Single, Clear
W
2.0
6.0
15.0
57.68
0.85
738.7
As -Built Total:
414.9
16749.8
WALL TYPES
Area X BSPM =
Points
Type
R-Value Area X SPM =
Points
Adjacent
232.0 0.70
162.4
Concrete, Ext Insul, Exterior
4.0
1806.1
0.50
903.0
Exterior
1806.1 1.90
3431.6
Frame, Wood, Adjacent
11.0
232.0
0.70
162.4
Base Total:
2038.1
3594.0
As -Built Total:
2038.1
1065.4
DOOR TYPES
Area X BSPM =
Points
Type
Area X SPM =
Points
Adjacent
0.0 0.00
0.0
Exterior
0.0 0.00
0.0
Base Total:
0.0
0.0
As -Built Total:
0.0
0.0
CEILING TYPES Area X BSPM =
Points
Type
R-Value
Area X SPM X SCM =
Points
Under Attic
3659.0 2.13
7793.7
Under Attic
30.0
3659.0
2.13 X 1.00
7793.7
Base Total:
3659.0
7793.7
As -Built Total:
3659.0
7793.7
EnergyGauge® DCA Form 60OA-2001 EnergyGauge®/FlaRES'2001 FLRCSB v3.30
FOW 60OA-2001
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT #:
BASE
AS -BUILT
FLOOR TYPES
Area X BSPM = Points
Type
R-Value Area
X SPM
= Points
Slab
277.4(p) -31.8
-8821.3
Slab -On -Grade Edge Insulation 0.0 277.4(p
-31.90
-8849.1
Raised
0.0 0.00
0.0
Base Total:
-8821.3
As -Built Total:
277.4
-8849.1
INFILTRATION
Area X BSPM = Points
Area X SPM
= Points
3659.0 14.31
52360.3
3659.0
14.31
52360.3
Summer Base Points:
71905.9
Summer As -Built Points:
69120.2
Total Summer
X System =
Cooling
Total X
Cap
X Duct X System X
Credit
= Cooling
Points
Multiplier
Points
Component
Ratio
Multiplier Multiplier
Multiplier
Points
(DM x DSM x AHU)
69120.2
0.333
(1.087 x 1.150 x 0.90) 0.284
0.950
6997.6
69120.2
0.667
(1.087 x 1.150 x 0.90) 0.284
0.950
13995.2
71905.9
0.4266
30675.0
69120.2
1.00
1.125 0.284
0.950
20992.8
EnergyGaugeTm DCA Form 60OA-2001 EnergyGauge®/FIaRES'2001 FLRCSB v3.30
FOkM 60OA-2001
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS:... PERMIT #:
BASE
AS -BUILT
GLASS TYPES
.18 X Conditioned X BWPM =
Points
Overhang
Floor Area
Type/SC
Ornt
Len
Hgt
Area X WPM X WOF = Poin
.18 3659.0 5.86
3869.5
Single, Clear
NW
2.0
5.0
8.8
14.97
1.00
131.3
Single, Clear
W
2.0
5.0
27.6
13.25
1.03
376.8
Single, Clear
SW
2.0
5.0
8.8
11.59
1.09
111.0
Single, Clear
N
2.0
8.0
8.0
15.07
1.00
120.1
Single, Clear
E
2.0
6.0
15.0
12.37
1.03
191.2
Single, Clear
NE
2.0
6.0
14.6
14.70
1.00
214.8
Single, Clear
N
2.0
6.0
30.0
15.07
1.00
450.1
Single, Clear
NW
2.0
6.0
14.6
14.97
1.00
217.9
Single, Clear
E
2.0
6.0
65.0
12.37
1.03
828.5
Single, Clear
E
2.0
7.0
12.0
12.37
1.02
152.0
Single, Clear
E
6.0
8.0
45.3
12.37
1.11
624.5
Single, Clear
NE
6.0
6.0
9.6
14.70
1.00
141.3
Single, Clear
SE
6.0
6.0
9.6
10.59
1.49
151.8
Single, Clear
W
2.0
6.0
24.0
13.25
1.02
324.8
Single, Clear
W
16.0
8.0
48.0
13.25
1.11
705.8
Single, Clear
W
16.0
8.0
24.0
13.25
1.11
352.9
Single, Clear
W
2.0
9.0
12.0
13.25
1.01
160.2
Single, Clear
S
2.0
6.0
15.0
9.90
1.12
165.8
Single, Clear
S
2.0
8.0
8.0
9.90
1.05
83.2
Single, Clear
W
2.0
6.0
15.0
13.25
1.02
203.0
As -Built Total:
414.9
5706.6
WALL TYPES Area X BWPM
= Points
Type
R-Value
Area X WPM
=
Points
Adjacent 232.0 1.80
417.6
Concrete, Ext Insul, Exterior
4.0
1806.1
2.40
4334.6
Exterior 1806.1 2.00
3612.2
Frame, Wood, Adjacent
11.0
232.0
1.80
417.6
Base Total: 2038.1
4029.8
As -Built Total:
2038.1
4752.2
DOOR TYPES Area X BWPM
= Points
Type
Area
X WPM
=
Points
Adjacent 0.0 0.00
0.0
Exterior 0.0 0.00
0.0
Base Total: 0.0
0.0
As -Built Total:
0.0
0.0
CEILING TYPES Area X BWPM
= Points
Type
R-Value Area X WPM X WCM =
Points
Under Attic 3659.0 0.64
2341.8
Under Attic
30.0
3659.0
0.64 X 1.00
2341.8
Base Total: 3659.0
2341.8
As -Built Total:
3659.0
2341.8
EnergyGauge® DCA Form 60OA-2001 EnergyGauge®/FlaRES'2001 FLRCSB v3.30
FOkM 60OA-2001
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT #:
BASE
AS -BUILT
FLOOR TYPES
Area X BWPM = Points
Type
R-Value Area X
WPM
= Points
Slab 277.4(p) -1.9
-527.1
Slab -On -Grade Edge Insulation 0.0 277.4(p
2.50
693.5
Raised
0.0 0.00
0.0
Base Total:
-527.1
As -Built Total:
277.4
693.5
INFILTRATION
Area X BWPM = Points
Area X
WPM
= Points
3659.0 -0.28
-1024.5
3659.0
-0.28
-1024.5
Winter Base Points:
8679.5
Winter As -Built Points:
12469.6
Total Winter X
System =
Heating
Total X
Cap
X Duct X System X
Credit
= Heating
Points
Multiplier
Points
Component
Ratio
Multiplier Multiplier Multiplier
Points
(DM x DSM x AHU)
12469.6
0.320
(1.078 x 1.160 x 0.92) 1.000
0.950
4361.0
12469.6
0.680
(1.078 x 1.160 x 0.92) 1.000
0.950
9267.2
8679.5
0.6274
5445.5
12469.6
1.00
1.150 1.000
0.950
13628.3
EnergyGauge'rm DCA Form 60OA-2001 EnergyGauge®/FlaRES'2001 FLRCSB v3.30
FOIRM 60OA-2001
WATER HEATING & CODE COMPLIANCE STATUS
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT #:
BASE I AS -BUILT
WATER HEATING
Number of X Multiplier
= Total
Tank EF
Number of
X Tank X Multiplier X
Credit = Total
Bedrooms
Volume
Bedrooms
Ratio
Multiplier
3 2564.00
7692.0
52.0 0.88
3
0.57 2564.00
1.00 4347.7
40.0 0.88
3
0.43 2564.00
1.00 3344.3
As -Built Total:
7692.0
CODE
COMPLIANCE STATUS
BASE
AS -BUILT
Cooling + Heating +
Points Points
Hot Water
Points
= Total
Points
Cooling + Heating + Hot Water = Total
Points Points Points Points
30675 5446
7692
43813
20993 13628 7692 42313
PASS
EnergyGaugeTm DCA Form 60OA-2001 EnergyGaugeO/FIaRES'2001 FLRCSB v3.30
' FORM 60OA-2001
Code Compliance Checklist
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT #:
6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST
COMPONENTS
SECTION
REQUIREMENTS FOR EACH PRACTICE
CHECK
Exterior Windows & Doors
606.1.ABC.1.1
Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area.
Exterior & Adjacent Walls
606.1.ABC.1.2.1
Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall;
foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility
penetrations; between wall panels & top/bottom plates; between walls and floor.
EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends
from, and is sealed to, the foundation to the top plate.
Floors
606.1.ABC.1.2.2
Penetrations/openings >1/8" sealed unless backed by truss or joint members.
EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed
to the perimeter, penetrations and seams.
Ceilings
606.1.ABC.1.2.3
Between walls & ceilings; penetrations of ceiling plane of top floor, around shafts, chases,
soffits, chimneys, cabinets sealed to continuous air barrier, gaps in gyp board & top plate;
attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is
installed that is sealed at the perimeter, at penetrations and seams.
Recessed Lighting Fixtures
606.1.ABC.1.2.4
Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a
sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from
conditioned space, tested.
Multi -story Houses
606.1.ABC.1.2.5
Air barrier on perimeter of floor cavity between floors.
Additional Infiltration reqts
606.1.ABC.1.3
Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA,
have combustion air.
6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.)
COMPONENTS
SECTION
REQUIREMENTS
CHECK
Water Heaters
612.1
Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit
breaker electric or cutoff as must be provided. External or built-in heat trap required.
Swimming Pools & Spas
612.1
Spas & heated pools must have covers (except solar heated). Non-commercial pools
must have a pump timer. Gas spa & pool heaters must have a minimum thermal
efficient of 78%.
Shower heads
612.1
Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG.
Air Distribution Systems
610.1
All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically
attached, sealed, insulated, and installed in accordance with the criteria of Section 610.
Ducts in unconditioned attics: R-6 min. insulation.
HVAC Controls
607.1
Separate readily accessible manual or automatic thermostat for each system.
Insulation
604.1, 602.1
Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides.
Common ceiling & floors R-11.
EnergyGaugeTm DCA Form 60OA-2001 EnergyGauge®/FlaRES'2001 FLRCSB v3.30
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE SCORE* = 85.0
The higher the score, the more efficient the home.
1. New construction or existing
2. Single family or multi -family
3. Number of units, if multi -family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Glass area & type
a. Clear - single pane
b. Clear - double pane
c. Tintlother SHGC - single pane
d. Tint/other SHGC - double pane
8. Floor types
a. Slab -On -Grade Edge Insulation
b. N/A
c. N/A
9. Wall types
a. Concrete, Ext Insul, Exterior
b. Frame, Wood, Adjacent
c. N/A
d. N/A
e. N/A
10. Ceiling types
a. Under Attic
b. N/A
c. N/A
11. Ducts
a. Sup: Unc. Ret: Unc. AH: Interior
b. Sup: Unc. Ret: Unc. AH: Interior
New _
12. Cooling systems
Single family _
a. Central Unit
Cap: 24.0 kBtu/hr
1 _
SEER:12.00 _
No _
b. Central Unit FILE COPY
Cap SEER48.0 hr
� .00 _
3659 ft2
c. N/A
Single Pane Double Pane _
-
414.9 ft2 0.0 ft2 _
13. Heating systems
0.0 ft2 0.0 ft2 _
a. Electric Strip
Cap: 16.0 kBtu/hr _
0.0 ft2 0.0 ft2 _
COP: 1.00 _
b. Electric Strip
Cap: 34.0 kBtu/hr _
_
COP:1.00 _
R=0.0, 277.4(p) ft _
c. N/A
_
14. Hot water systems
_
a. Electric Resistance
Cap: 52.0 gallons _
R=4.0, 1806.1 ft2 _
EF: 0.88
R=11.0, 232.0 ft2 _
b. Electric Resistance
Cap: 40.0 gallons _
_
EF: 0.88 _
_
c. Conservation credits
_
(HR-Heat recovery, Solar
DHP-Dedicated heat pump)
R=30.0, 3659.0 ft2 _
15. HVAC credits
PT,
(CF-Ceiling fan, CV -Cross ventilation,
HF-Whole house fan,
_
PT -Programmable Thermostat,
Sup. R=6.0, 83.1 ft _
MZ-C-Multizone cooling,
Sup. R=6.0, 170.8 ft
MZ-H-Multizone heating)
I certify that this home has complied with the Florida Energy Efficiency Code For Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliapVeaVqres.
Builder Signature: ��.w�� r"G.�if/ Date:
Address of New Home: ZQ City/FL Zip:
*NOTE: The home's estimated energy performance score is only available through the FLARES computer program.
This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a US EPADOE EnergyStar designation),
your home may qualijyfor energy efficiency mortgage (EEAP incentives if you obtain a Florida Energy Gauge Rating.
Contact the Energy Gauge Hotline at 3211638-1492 or see the Energy Gauge web site at www.fsec. ucf edu for
information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction,
contact the Department of Community Affairs at 8501487-1824.
EnergyGauge® (Version: FLRCSB v3.30)