Loading...
HomeMy WebLinkAboutProject InformationJob M Performed by for: DRAWDY RESIDENCE GEMANY CANAL RD. FT. PIERCE, FL Sheet 1 DRAWDY RESIDENCE QUICK CALCS, INC. 317 ST. LUCIE.LN., Phone: 772-466-6799 Scale: 1 : 173 Page 1 Right -Suite Residential 5.9.56 RSR31845 2005-May-03 10:47:35 Documents\Wrightsoft h Project Summary ZONE 2 DRAWDY RESIDENCE QUICK CALLS, INC., 317 ST. LUCIE LN., Phone: 772-166-6799 • eieci fInformation' Job: Date: Apr 28, 2005 By: For: DRAWDY RESIDENCE GEMANY CANAL RD., FT. PIERCE, FL FILF C0PI Notes: Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 16118 Btuh Structure 14942 Btuh Ducts 992 cfm Ducts 1988 Btuh Central vent (43 cfm) 1333 Btuh Central vent (43 cfm) 714 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 18443 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 16762 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 2252 Btuh Ducts 380 Btuh Heatingg coolingg Central vent (43 cfm) load 1809 4441 Btuh Btuh Area (ftz) 1088 1088 Equipment latent Volume (ft�) 8616 8616 Air changes/hour 0.51 0.24 Equipment total load 21203 Btuh Equiv. AVF (cfm) 73 35 Req. total capacity at 0.70 SHR 2.0 ton Heating Equipment Summary Cooling Equipment Summary Make n/a Make Trane Trade Trade XR12 Model n/a Cond 2TTR2024A1 Coil TWE024P13FB Efficiency 100 EFF Efficiency 12 SEER Heating input 0 Btuh Sensible cooling 16800 Btuh Heating output 18443 Btuh Latent cooling 7200 Btuh Temperature rise 19 OF Total cooling 24000 Btuh Actual air flow 906 cfm Actual air flow 906 cfm Air flow factor 0.053 cfm/Btuh Air flow factor 0.054 cfm/Btuh Static pressure 0.00 in H2O Static pressure 0.00 in H2O Space thermostat Load sensible heat ratio 0.80 Boldldalic values have been manually overridden Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wrig 1-litsoft Right -Suite Residential 5.9.56 RSR31845 2005-May-03 10:47:41 ACCK C:1My Documents\Wrightsoft WACIDRAWDY RESIDENE.rrp Calc = MJ8 Orientation = E Page 1 Project Summary ZONE #1 DRAWDY RESIDENCE QUICK CALCS, INC., 317 ST. LUCIE LN., Phone: 772-466-6799 For: Notes: Job: Date: Apr 28, 2005 By: DRAWDY RESIDENCE GEMANY CANAL RD., FT. PIERCE, FL BILE COPY Desi n Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Structure 30122 Btuh Ducts 2748 cfm Central vent (91 cfm) 2798 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 35669 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 1 (Average) Heating Co 0' Area (W) 2577 257-9 Volume (ft') 24101 24101 Air changes/hour 0.25 0.12 Equiv. AVF (cfm) 99 47 Heating Equipment Summary Make n/a Trade Model n/a Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 0 Btuh 356699 Btuh 18 OF 1801 cfm 0.055 cfm/Btuh 0.00 in H2O Sensible Cooling Equipment Load Sizing Structure 28193 Btuh Ducts 5460 Btuh Central vent (91 cfm) 1499 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 33394 Btuh Latent Cooling Equipment Load Sizing Structure 2165 Btuh Ducts 909 Btuh Central vent (91 cfm) 3799 Btuh Equipment latent load 6873 Btuh Equipment total load 40267 Btuh Req. total capacity at 0.70 SHR 4.0 ton Cooling Equipment Summary Make Trane Trade XR12 Cond 2TTR2048A1 Coil TWE048P13FB Efficiency 12 SEER Sensible cooling 33600 Btuh Latent cooling 14400 Btuh Total cooling 48000 Btuh Actual air flow 1801 cfm Air flow factor 0.054 cfm/Btuh Static pressure 0.00 in H2O Load sensible heat ratio 0.84 Boldrdalic values have been manually ovem'dden Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wr101-Ittsoft Right -Suite Residential 5.9.56 RSR31845 2005-May-03 10:47:41 ACCK C:WIy Documents\Wrightsoft HVACIDRAWDY RESIDENE.rrp Calc = MJ8 Orientation = E Page 2 Right-J Worksheet Job: ZONE 2 By: Apr 28, zoos DRAWDY RESIDENCE QUICK CALCS, INC., 317 ST. LUCIE LN., Phone: 772-466.6799 1 Room name ZONE 2 THE RETREAT 2 Exposed wall 117.8 It 25.0 It 3 Ceiling height 8.0 It 8.0 It heat/cool 4 Room dimensions 18.0 x 20.0 It 5 Room area 1077.0 ft' 360.0 11 Ty Construction U-value Or HTM Area (tt2) Load Area (ft?) Load number (Btuh/ft2-°F) (B or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NIP/S Heat Cool Grow NIP/S Heat Cool 6 13A-4ocs 0.143 n 4.00 2.65 328 290 1161 738 40 40 160 102 1A-clom 1.270 n 35.56 34.77 8 0 284 278 0 0 0 0 1A-c1om 1.270 n 35.56 25.71 30 0 1067 .771 0 0 0 0 V�1 13A-4ocs 0.143 ne 4.00 2.55 34 19 78 49 0 0 0 0 11 �--G IA -clam 1.270 ne 35.56 48.57 15 0 519 708 0 0 0 0 Imo; IA-clom 1.270 ne 35.56 70.43 0 0 0 0 0 0 0 0 13A-40cs 0.143 a 4'.00 2.55 224 ' 179 717 456. 144 114 456 290 1A-clom 1.270 a 35.56 62.25 15 0 533 934 0 0 0 0 1A-clom 1.270 a 35.56 91.12 30 0 1067 2734 30 0 1067 2734 1A-clom 1.276 a 35.56 91.12 0 0 0 0 0 0 0 0 10A-m 1.670 a 46.76 53.19 0 0 0 0 0 0 0 0 T--G 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 1Aclom 1.270 se 35.56 70.95 0 0 0 0 0 0 0 0 13A-4ocs 0.143 s 4:00 2.55 80 80 320 204 16 16 64 41 1A-clom 1.270 s 35.56 37.88 0 0. 0 0 0 0 0 0 IA-clom 1.270 s 35.56 37.88 0 0 0 0 0 0 0 0 Val G 13A-4ocs 0.143 sw 4.00 2.55 34 25 101 64 0 0 0 0 7A-lgsnn 0.600 sw 16.80 33.58 9 0 148 '296 0 0 0 0 13A-4ocs 0.143 w 4.00 2.55 176 148 594 378 0 0 0 0 1A-clom 1.270 w 35.56 62.25 28 0 981 1718 0 0 0 0 1A-clom 1.270 w 35.56 69.17 0 0 0 0 0 0 0 0 10A-m 1.670 w 46.76 42.33 6 0 0 0- 0 0 0 0 'I OA-m 1.670 w 46.76 53.19 0 0 0 0 0 0 0 0 1 Dc2om 0.870 w 24.36 77.43 0 0 0 0 0 0 0 0 1A-clam 1.270 w 35.56 91.12 0 0 0 0 0 0 0 0 W , 13A-4ocs 0.143 nw 4.00 2.55 68 44 178 113 0 0 0 0 G 7A-1gsnn 0.600 nw 16.80 32.93 9 0 148 290 0 0 0 0 IA-clom 1.270 nw 35.56 48.57 15 0 519 708 0 0 0 0 P 12C-0sw 0.091 - 2.55 1.28 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 - 0.90 1.68 1077 1077 965 1809 360 360 323 605 C 17B-6al 0.105 - 2.94 4,57 0 0 0 0 0 0 0 0 F 22A-tph 1.358 - 38.02 0.00 1077 118 4480 0 360 25 951 0 .6 c) AED excursion 0 -229 Envelope losslgain 13860 12249 3021 3542 12 a) Infiltration 2258 573 478 121 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 4 920 3 690 Appliances @ 1200 1 1200 1 1200 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 16118 14942 3499 5554 15 Dud loads 6% 13% 992 1988 6°A 13% 215 739 Total room load 17110 16930 3714 6293 Air required (arm) 906 906 197 337 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wr�gl-�tsoi t Right -Suite Residential 5.9.56 RSR31845 2005-May-03 10:47:41 ACGP, C:\MyDocumeryts\WrightsoftHVAC\DRAWDYRESIDENE.rrp Calc = MJ8 Orientation = E Page 1 Right-J Worksheet ZONE 2 DRAWDY RESIDENCE QUICK CALCS, INC., 317 ST. LUCIE LN., Phone: 772466 6799 Job: Date: Apr 28, 2005 By: 1 Room name SITTING ROOM TOILET 2 Exposed wall 37.4 It 5.0 It 3 Ceiling height 8.0 It heaticool 8.0 ft heal/cool 4 Room dimensions 1.0 x 188.0 ft 6.0 x 5.0 ft 5 Room area 186.0 ftz 30.0 112 Ty Construction U-value Or HTM Area (ft) Load Area Load number (Btuh/ft-°F) (BtUh/ft2 or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat Cool 6 13A-4ocs 0.143 n 4.00 2.55 72 42 168 107 40 32 128 81 1A-clom 1.270 n 35.56 34.77 0 0 0 0 8 0 284 278 1A-clom 1.270 n 35.56 25.71 30 0 1067 771 0 0 0 0 1� 13A4ocs 0.143 ne 4.00 2.55 34 19 78 49 0 0 0 0 11 �--G 1A-clom 1.270 ne 35.56 48.57 15 0 519 708 0 0 0 0 IA-c1om 1.270 ne 35.56 70.43 0 0 0 0 0 0 0 0 13A-4ocs 0.143 a 4.00 2:55 80 65 260 165 0 0 0 0 1A-clom 1.270 a 35.56 62.25 15 0 533 934 0 0 0 0 1A-clom 1.270 a 35.56 91.12 0 0 0 0 0 0 0 0 1A-clom 1.270 a 35.56 91.12 0 0 0 0 0 0 0 0 1OA-m 1.670 a 46.76 53.19 0 0 0 0 0 0 0 0 Y-G 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 1A-clom 1.270 se 35.56 70.95 0 0 0 0 0 0 0 0 V�J 13A-4ocs 0.143 s 4.60 2.65 0 0 0 0 0 0 0 0 IA -clam 1.270 s 35.56 37.88 0 0 0 0 0 0 0 0 1A-clom 1.270 s 35.56 37.88 0 0 0 0 0 0 0 0 WI _ 13A-4ocs 0.143 sw 4.00 2.55 0 0 0 0 0 0 0 0 7A-lgsnn 0.600 sw 16.80 33.58 0 0 0 0 0 0 0 0 G 13A-4ocs 0.143 w 4.00 2.55 80 80 320 204 0 0 0 0 IA-clom 1.270 w 35.56 62.25 0 0 0 0 0 0 0 0 1A-clom 1.270 w 35.56 69.17 0 0 0 0 0 0 0 0 10A-m 1.670 w 46.76 42.33 0 0 0 0 0 0 0 0 10A-m 1.670 w 46.76 53.19 0 0 0 0 0 0 0 0 113-c2om 0.870 w 24.36 77.43 0 0 0 0 0 0 0 0 1A-clom 1.270 w 35.56 91.12 0 0 0 0 0 0 0 0 13A-4ocs 0.143 nw 4.00 2.55 34 19 78 49 0 0 0 0 7A-lgsnn 0.600 nw 16.80 32.93 0 0 0 0 0 0 0 0 IA-clom 1.270 nw 35.56 48.57 15 0 519 708 0 0 0 0 P 12C-Osw 0.091 - 2.55 1.28 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 - 0.90 1.68 186 186 167 312 30 30 27 50 C 17B-6al 0.105 - 2.94 4.57 0 0 0 0 0 0 0 0 F 22A-tph 1.358 - 38.02 0.00 186 37 1423 0 30 5 190 0 6 c) AED excursion -383 -40 Envelope loss/gain 5131 3625 630 370 12 a) Infiltration 717 182 96 24 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 1200 0 0 0 0 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 5848 3807 725 395 15 Duct loads 6% 13T. 360 507 6% 13% 45 53 Total room load 6208 4314 770 447 Air required (cfm) 329 231 1 41 24 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wrrrghtsoFC Right -Suite Residential 5.9.56 RSR31845 2005-May-0310A7.41 ACCfa C:1My Documents%Wrightsoft HVACIDRAWDY RESIDENE.rrp Calc = MJ8 Orientation = E Page 2 Right-J Worksheet Job: ZONE 2 Date: Apr 28, 2005 DRAWDY RESIDENCE By. QUICK CALCS, INC., 317 ST. LUCIE LN., Phone: 772-466-6799 1 Room name DRESSING ROOM MASTER BATH 2 Exposed wall 10.0 ft 40.4 It 3 Ceiling height 8.0 It heat/cool 8.0 It healfcool 4 Room dimensions 1.0 x 209.5 ft 1.0 x 291.5 It 5 Room area 209.5 W 291.5 ft2 Ty Construction U-value Or HTM Area (W) Load Area (ftj Load number (BtuMt-L.-F) (Btuh/fN) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool ss Grow W Heat Cool Gross W P/S Heat Cool 6 13A-4ocs 0.143 n 4.00 2.65 80 80 320 204 96 96 384 244 1A-c1om 1.270 n 35.56 34.77 0 0 0 6 0 D 0 0 1A-clom 1.270 n 35.56 25.71 0 0 0 0 0 0 0 0 W 13A4ccs 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 11 1A-ciom 1.270 ne 35.56 48.57 0 0 0 0 0 0 0 0 I��G 1Aclom 1.270 ne 35.56 70.43 0 0 0 0 0 0 0 0 13A-40cs 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 1Aclom 1.270 a 35.56 62.25 0 0 0 0 0 0 0 0 1A-clom 1.270 a 35.56 91.12 0 0 0 0 0 0 0 0 1A-clom 1.270 a 35.56 91.12 0 0 0 0 0 0 0 0 1OA-m 1.670 er 46.76 53.19 0 0 0 0 0 0 0 0 W, 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 �--G IA-clom 1.270 se 35.56 70.95 0 0 0 0 0 0 0 0 VjJ 13A-4ocs 0.143 s 4.00 2.55 0 0 0 0 64 64 256 163 1A-clom 1.270 s 35.56 37.88 0 0 0 0 0 0 0 0 1A-clom 1.270 s 35.56 37.88 0 0 0 0 0 0 0 0 W 13A-4ocs 0.143 sw 4.00 2.55 0 0 0 0 34 25 101 64 Ili 7A-1gsnn 0.600 sw 16.80 33.58 0 0 0 0 9 0 148 296 13A4ocs 0.143 w 4.00 2.55 0 0 0 0 96 68 274 174 1Aclom 1.270 w 35.56 62.25 0 0 0 0 28 0 981 1718 1Aclom 1.270 w 35.56 69.17 0 0 0 0 0 0 0 0 10A-m 1.670 w 46.76 42.33 0 0 0 0 0 0 0 0 1OA-m 1.670 w 46.76 53.19 0 0 0 0 0 0 0 0 1D-c2om 0.870 w 24.36 77.43 0 0 0 0 0 0 0 0 1Aclom 1.270 w 35.56 91.12 0 0 0 0 0 0 0 0 13A-4ocs 0.143 nw 4.00 2.55 0 0 0 0 34 25 101 64 7A-igsnn 0.600 nw 16.80 32.93 0 0 0 0 9 0 148 290 IA-clom 1.270 nw 35.56 48.57 0 0 0 0 0 0 0 0 P 12C-Osw 0,091 - 2.55 1.28 0 0 0 0 0 0 0 0 C 1613-30ad 0.032 - 0.90 1.68 210 210 188 352 292 292 261 490 C 17B-6al 0'.105 - 2.94 , 4.57 0 0 0 0 0 0 0 0 F 22A-tph 1.358 - 38.02 0.00 210 10 380 0 292 40 1537 0 6 c) AED excursion -76 728 Envelope loss/gain 888 479 4191 4232 12 a) Infiltration 191 49 775 197 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances @ 1200 0 0 0 0 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1080 758 4966 4428 15 Duet loads 6% 131Y. 66 101 6% 13% 306 589 Total room load 1146 859 1 5272 5018 Air required (&n) 61 46 279 269 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. vVVIr C-J ZLE o- VC Right-Sufte Residential 5.9.56 RSR31845 2005-May-0310:47:41 ACCA C:Wy DocumentslWrightsoft HVACIDRAWDY RESIDENE.rrp Calc = MJ8 Orientation = E Page 3 Right-J Worksheet t ZONE #1 DRAWDY RESIDENCE QUICK CALCS, INC., 317 ST. LUCIE LN., Phone: 772-466-6799 Job: Date: Apr 28, 2005 By: 1 Room name ZONE #1 BEDROOM #3 2 Exposed wall 159.6 ft 35.0 ft 3 Ceiling height 9.4 ft 8.0 ft heat/000l 4 Room dimensions 16.0 x 15.0 ft 5 Room area 2561.0 1`12 240.0 ft' Ty Construction U-value Or HTM Area (ft2) Load Area Load number (Btuh/ft-F) (B or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat cool Gnus NIP/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 0.143 n 4.00 2.55 48 48 192 122 32 32 128 81 IA-c1om 1.270 n 35.56 34.77 0 '0 0 0 0 0 0 0 IA -clam 1.270 n 35.56 25.71 0 0 0 0 0 0 0 0 13A4ocs 0.143 ne 4.00 2.55 23 13 52 33 0 0 0 0 11 IA-clom 1.270 ne 35.56 48.57 0 0 0 0 0 0 0 0 IA-clom 1.270 ne 35.56 70.43 10 0 341 675 0 0 0 0 13A.4ocs 0.143 a 4.00 2.55 320 228 912 580 0 0 0 0 1A-clom 1.270 a 35.56 62.25 0 0 0 0 0 0 0 0 1A-clom 1.270 a 35.56 91.12 35 0 - 1245 3189 0 0 0 0 1A-clom 1.270 a 35.56 91.12 12 0 427 1093 0 0 0 0 10A-m 1.670 a 46.76 53.19 45 0 2120 2411 0 0` 0 0 t13A-40cs 0.143 se 4.00 2.55 23 13 52 33 0 0 0 0 1A-clom 1.270 se 35.56 70.95 10 10 341 333 0 0 0 0 -G 13A-4ocs 0.143 s 4.00 2.55 312 289 1157 736 120 120 480 305 1A-clom 1.270 s 35.55 37.88 15 15 533 522 0 0 0 0 1A-clom 1.270 s 35.56 37.88 8 a 284 278 0 0 0 0 V)/ L-G 13A-4ocs 0.143 sw 4.00 2.55 0 0 0 0 0 0 0 0 7A-lgsnn 0.600 sw 16.80 33.58 0 0 0 0 0 0 0 0 13A4ocs 0.143 w 4.00 2.55 552 429 1718 1092 128 113 452 288 IA-clom 1.270 w 35.56 62.25 0 0 0 0 0 0 0 0 IA-c1om 1.270 w 35.56 69.17 24 0 853 1660 0 0 0 0 10A-m 1.670 w 46.76 42.33 48 32 2244 1395 0 01 0 0 10A-m 1.670 w 46.76 53.19 24 16 1122 835 0 0 0 0 1 D-c2om 0.870 w 24.36 77.43 12 0 292 929 0 0 0 0 1A-clom 1.270 w 35.56 91.12 15 0 533 1367 15 0 533 1367 13A-4ocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 7A-1gsnn 0.600 nw 16.80 32.93 0 0 0 0 0 0 0 0 IA-clom 1.270 nw 35.56 48.57 0 0 0 0 0 0 0 0 P 12C-0sw 0.091 - 2.55 1.28 232 232 591 298 0 0 0 0 C 16B-30ad 0.032 - 0.90 1.68 1053 1053 943 1769 240 240 215 403 C 17B-6al 0.105 - 2.94 4.57 1716 1716 5044 7837 0 0 0 0 F 22A-tph 1.358 - 38.02 0.00 2561 160 6068 0 240 35 1331 0 6 c) AED excursion 0 164 Envelope loss/gain 27067 27187 3140 2608 12 a) Infiltration 3056 775 670 170 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances @ 1200 0 0 0 0 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 -0 7 11 14 Subtotal 30122 28193 3817 2789 15 Dud loads 9% 19% 2748 5460 9% 19% 348 540 Total room load 32870 33653 4165 3329 Air required (cfm) 1801 1801 228 178 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wrrg F7t50 Ft Right -Suite Residential 5.9.56 RSR31845 2005-May-0310:47:41 ,4=1, C:1My Documents\Wrightsoft HVACIDRAWDY RESIDENE.rrp Calc = MJ8 Orientation = E Page 4 Right-J Worksheet ZONE #1 DRAWDY RESIDENCE QUICK CALCS, INC., 317 ST. LUCIE LN., Phone: 772-466-6799 Job: . Date: Apr 28, 2005 By: 1 Room name BATH #1 BEDROOM #2 2 Exposed wall 7.0 ft 15.0 ft 3 Ceiling height 8.0 ft heat1cool 8.0 ft heat/cool 4 Room dimensions 12.0 x 7.0 ft 1.0 x 234.0 ft 5 Room area 84.0 W 234.0 ftz Ty Construction U-value Or HTM Area (ft) Load Area (fF) Load number (Btuh/ft2-°F) (Btuhfft2 or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/PIS Heat Cool 6 ll)I 13A-4ocs 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0 IIA-c1om 1A-clom 1270 1.270 n n 35.56 35.56 34.77 25.71 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I;-GG 11 13A.4ocs 1A-Glom 0.143 1.270 ne ne 4.00 35.56 2.55 48.57 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 LLL���-----���; 1A-clom 13A-4ocs 1.270 0.143 ne a 35.56 4.00 70.43 2.55 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 IA-c1om IA-clom 1.270 1.270 a a 35.56 35.56 62.25 91.12 0 6 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1A-clom 10A-m 1.270 1.670 a a 35.56 46.76 91.12 63.19 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 t-G 13A-4ocs 1A-c1om 0.143 1.270 se se 4.00 35.56 2.55 70.95 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13A-4ocs 1A-clom 0.143 1.270 s s 4.00 35.56 2.55 37.88 56 6 48 0 192 0 122 0' 120 15 105 15 420 533 267 522 1A-c1om 13A-4ocs 1.270 0.143 s sw 35.56 4.00 37.88 2.55 8 0 8 0 284 0 278 0 0 0 0 0 0 0 0 0 W 1-G 7A-1gsnn 13A-4ocs 0.600 0.143 sw w 16.80 4.00 33.68 2.55 0 0. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1A-clam 1A-clom 1.270 1.270 w w 35.56 35.56 62.25 .69.17, D 0 0 0 0 0 0 0 0 0 0 0. 0 0 0 0 10A-m 10A-m 1.670 1.670 w w 46.76 46.76 42.33 53.19 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 D-c2om IA-clom 0.870 1.270 w w 24.36 35.56 77.43 91.12 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 T:f213A-4ocs 7A-1gsnn 0.143 0.600 nw nw 4.00 16.80 2.55 32.93 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1A-clom 12C-Osw 1.270 0.091 nw - 35.56 2.55 48.57 1.28 0 0 0 0 0 0 0 0 0 128 0 128 0 326 0 164 P C 16B-30ad 0.032 - 0.90 1.68 84 84 75 141 234 234 210 393 C 17B-6al 0.106 - 2.94 4.57 0 0 0 0 0 - 0 0 0 F 22A-tph 1.358 - 38.02 0.00 84 7 266 0 234 15 570 0 6 c) AED excursion -82 -128 Envelope loss/gain 818 460 2060 1218 12 a) Infiltration 134 34 287 73 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 1200 0 0 0 0 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 12 19 8 14 14 Subtotal 964 513 2356 1305 15 Dud loads 9% 190/0 88 99 9% 190/0 215 253 Total room load 1052 612T 2570 1558 Air required (cfm) 58 33 141 83 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wrngl'ttsolrt Right -Suite Residential 5.9.56 RSR31845 2005•May-03 10:47:41 ACCA C:XMy DocumentslWrightsoft HVACIDRAWDY RESIDENE.rrp Calc = MJ8 Orientation = E Page 5 !fVF Right-J Worksheet Job: 0 ZONE #1 Date: Apr 28, zoos DRAWDY RESIDENCE QUICK CALCS, INC., 317 ST. LUCIE LN., Phone: 772-466-6799 1 Room name LAUNDRY KITCHEN 2 Exposed wall 0.0 ft 16.0 ft 3 Ceiling height 8.0 ft heat/cool 10.4 ft heat/cool 4 Room dimensions 9.0 x 12.0 ft 1.0 x 304.0 ft 5 Room area 108.0 ftz 304.0 ftz Ty Construction U-value Or HTM Area (ft2) Load Area (ft) Load number (Btuh/iiA-'IF) (B or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6> 13A-4ocs 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0 IA-c1om 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0 IA-c1om 1.270 n 35.56 25.71 0 0 0 0 0 0 0 0 13A4ocs 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 11 1A-c1om 1.270 ne 35.56 48.57 0 0 0 0 0 0 0 0 IA-clom 1.270 ne 35.56 70.43 0 0 0 0 0 0 0 0 13A-4ocs 0.143 a 4.00 Z65 0 0 0 0 0 0 0 0 IA-clom 1.270 a 35.56 62.25 0 0 0 0 0 0 0 0 IA-clom 1.270 a 35.56 91.12 0 0 0 0 0 0 0 0 IA-clom 1.270 a 35.56 91.12 0 0 0 0 0 0 0 0 10A-m 1.670 a 46.76 53.19 0 0 0 0 0 0 0 0 W 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 �--G IA-clom 1.270 se 35.56 70.95 0 0 0 0 0 0 0 0 V1J 13A-4ocs 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0 {L-_(� IA-clom 1.270 s 35.56 37.88 0 0 0 0 0 0 0 0 IA-clom 1.270 s 35.56 37.88 0 0 0 0 0 0 0 0 V�/ l-G 13A-4ocs 0.143 sw 4.00 2.55 0 0 0 0 0 0 0 0 7A-1gsnn 0.600 sw 16.80 33.58 0 0 0 0 0 0 0 0 W 13A-4ocs 0.143 w 4.00 2.55 0 0 0 0 128 116 464 295 IA-clom 1.270 w 35.56 62.25 0 0 0 6 0 0 0 0 IA-clom 1.270 w 35.56 69A7 0 0 0 0 0 0 0 0 10A-m 1.670 w 46.76 42.33 0 0 0 0 0 0 0 0 10A-m 1.670 w 46.76 53.19 0 0 0 0 0 0 0 0 113-c2om 0.870 w 24.36 77.43 0 0 0 0 12 0 292 929 IA-clom 1.270 w 35.56 91.12 0 0 0 0 0 0 0 0 V�! 13A-4ocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 7A-1gsnn 0.600 nw 16.80 32.93 0 0 0 0 0 0 0 0 1A-clom 1.270 nw 35.56 48.57 0 0 0 0 0 0 0 0 P 12C-Osw 0.091 - 2.55 1.28 72 72 183 92 0 0 0 0 C 16B-30ad 0.032 - 0.90 1.68 108 108 97 181 0 0 0 0 C 176-6al 0.105 - 2.94 4.57 0 0 0 0 346 346 1017 1580 F 22A-tph 1.358 - 38.02 0.00 108 0 0 0 304 16 608 0 6 c) AED excursion -39 -22 Envelope loss/gain 280 235 2382 2783 12 a) Infiltration 0 0 306 78 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 1200 0 0 0 0 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 15 25 8 14 14 Subtotal 295 260 2697 2874 15 Dud loads 9% 19% 27 50 9% 19% 246 557 Total room load 322 310 2943 3431 Air required (cfm) 181 17 161 184 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. Right -Suite Residential 5.9.56 RSR31845 2005-May-0310:47.41 ACCA C:1My DocumentslWrightsoft HVACIDRAWDY RESIDENE.rrp Calc = MJ8 Orientation = E Page 6 Right-J Worksheet - ZONE #1 DRAWDY RESIDENCE QUICK CALCS, INC., 317 ST. LUCIE LN., Phone:,772-46"799 Job: Date: Apr 28, 2005 By: 1 Room name HALL DINING ROOM 2 Exposed wall 0.0 ft 16.0 It 3 Ceiling height 8.0 ft heaticool 10.4 It heaUcool 4 Room dimensions 1.0 x 81.0 ft 1.0 x 232.0 ft 5 Room area 81.0 ft2 232.0 112 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuhlft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/PIS Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0 1A-clom 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0 IA-clom 1.270 n 35.56 25.71 0 0 0 0 0 0 0 0 V1J 13A4ocs 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 11 I-G 1A-clom 1.270 ne 35.56 48.57 0 0 0 0 0 0 0 0 I� 1A-clom 1.270 ne 35.56 70.43 0 0 0 0 0 0 0 0 13A-4ocs 0.143 a 4.00 2.55 0 0 0 0 128 102 408 260 IA-clom 1.270 a 35.56 02.25 0 0 0 0 0 0 0 0 IA-clom 1.270 a 35.56. 91.12 0 0 0 0 20 0 711 1822 IA-clom 1.270 a 35.56 91.12 0 0 0 0 6 0 213 547 10A-m 1.670 a 46.76 53.19 0 0 0 0 0 0 0 0 V)/ 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 IA-c1om 1.270 se 35.56 70.95 0 0 0 0 0 0 0 0 -G Vhl 13A4ocs 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0 G 1A-c1om 1.270 s 35.56 37.88 0 0 0 0 0 0 0 0 LE 1A-clom 1.270 s 35.56 37.88 0 0 0 0 0 0 0 0 tV�/ IG 13A-4ocs 0.143 sw 4.00 2.55 0 0 0 0 0 0 0 0 7A-lgsnn 0.600 sw 16.80 33.58 0 0 0 0 0 0 0 0 13A-4ocs 0.143 w 4.00 2i55 0 0 0 0 0 0 0 0 IA-clom 1.270 w 35.56 62.25 0 0 0 0 0 0 0 0 1A-clom 1.270 w 35.56 69.17 0 0 0 0 0 0 0 0 10A-m 1.670 w 46:76 42.33 01 0 0 0 0 0 0 0 10A-m 1.670 w 46.76 53.19 0 0 0 0 0 0 0 0 1 D-c2om 0.870 w 24.36 77.43 0 0 0 0 0 0 0 0 1A-clom 1.270 w 35.56 91.12 0 0 0 0 0 0 0 0 13A-4ocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 7A-1gsnn 0.600 nw 16.80 32.93 0 0 0 0 0 0 0 0 IA-clom 1.270 nw 35.56 48.57 0 0 0 0 0 0 0 0 P 12C-0sw 0.091 - 2.55 1.28 0 0 0 0 32 32 82 41 C 1613-30ad 0.032 - 0.90 1.68 81 81 73 136 0 0 0 0 C 17B-6al 0.105 - 2.94 4.57 0 0 0 0 264 264 776 1206 F 22A-tph 1.358 - 38.02 0.00 81 0 0 0 232 16 608 0 6 c) AED excursion -19 -314 Envelope loss/gain 73 117 2799 3561 12 a) Infiltration 0 0 306 78 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 1200 0 0 0 0 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -73 -117 0 0 14 Subtotal 0 0 3105 3639 15 Duct loads 90/0 19% 0 0 9% 19% 283 705 Total room load 0 0 3388 4344 Air required (cfm) 0 0 186 232 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wrotcl 'Lsoft Right -Suite Residential 5.9.56 RSR31845 2005•May-0310.47:41 ACCA C:kMy DocumentsWrightsoft HVACIDRAWDY RESIDENE.rrp Calc = MJ8 Orientation = E Page 7 . - Right-J Worksheet Job: ZONE #1 Date: Apr 28, 2005 DRAWDY RESIDENCE By QUICK CALCS, INC., 317 ST. LUCIE LN., Phone: 772-466-6799 1 Room name GREAT ROOM PANTRY 2 Exposed wall 28.0 ft 9.0 ft 3 Ceiling height 10.4 ft heaUCool 8.0 ft heat/cool 4 Room dimensions 1.0 x 771.5 ft 1.0 x 109.0 ft 5 Room area 771.5 ft2 109.0 ft2 Ty Construction number U-value (Btuhlft-F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross WP/S Heat Cool Gross NN/P/S Heat Cool 6 13A-4ocs 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0 1A-clom 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0 IA-clom 1.270 n 35.56 25.71 0 0 0 0 0 0 0 0 yJ 13A� 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 11 I-G 1A-c1om 1.270 ne 35.56 48.57 0 0 0 0 0 0 0 0 Imo; IA-clom 1.270 ne 35.56 70.43 0 0 0 0 0 0 0 0 13A-4ocs 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 IA-clwi 1.270 a 35.56. 62.25 0 0 0 0 0 0 0 0 1A-clom. 1.270 a 35.56 91.12 0 0 0 0 0 0 0 0 IA-clom 1.270 a 35.56 91.12 0 0 0 0 0 0 0 0 10A-m 1.670 a 46.76 $3.19 0 0 0 0' 0 0 0 0 t-G 13A-40cs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 IA-clom 1.270 se 35.56 70.95 0 0 0 0 0 0 0 0 13A-4ocs 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0 tV1J IA-clom 1.270 s 35.56 37.88 0 0 0 0 0 0 0 0 I;_{G; IA-clom 1.270 s 35.56 37.88 0 .0 0 0 0 0 0 0 Vrl 13A-4ocs 0.143 sw 4.00 2.55 0 0 0 0 0 0 0 0 7A-1 gsnn 0.600 sw 16.80 33.58 0 0 0 0 0 0 0 0 -G 13A-4ocs 0.143 w 4.00 2.55 224 128 513 326 72 72 288 183 IA-c1om 1.210 w 35.56 62.25 0 0 0 0 0 0 0 0 IA-clom 1.270 w 36.56 69.17 24 0 853 1660 0 0 0 0 10A-m 1.670 w 46.76 42.33 48 32 2244 1395 0 0 0 0 10A-m 1.670 w 46.76 53.19 24 16 1122 835 0 0 0 0 ID -Qom 0.870 w 24.36 77.43 0 0 0 0 0 0 0 0 IA-c1om 1.270 w 35.56 91.12 0 0 0 0 0 0 0 0 13A-40cs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 7A-lgsnn 0.600 nw 16.80 32.93 0 0 0 0 0 0 0 0 1A-c1om 1.270 nw 35.56 48.57 0 0 0 0 0 0 0 0 P 12C-0sw 0.091 - 2.65 1.20 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 - 0.90 1.68 0 0 0 0 109 109 98 183 C 17B-6al 0:105 - 2.94 4.57 878 878 2581 4009 0 0 0 0 F 22A tph 1.358 - 38.02 0.00 772 26 1065 0 109 9 342 0 6 c) AED excursion 1220 -58 Envelope loss/gain 8378 9446 728 308 12 a) Infiltration 536 136 172 44 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances @ 1200 0 0 0 0 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 7 11 14 Subtotal 8914 9812 907 363 15 Dud loads 9% 190/0 813 1900 90/0 19% 83 70 Total room load 9727 11712 990 433 Air required (cfm) 533 627 54 23 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wrrrghtsoi t Right-Sufte Residential 5.9.56 RSR31845 2005-May-0310:47:41 AC ak C:IMy Doc umentslWrightsoft HVACIDRAWDY RESIDENE.rrp Calc = MJ8 Orientation = E Page 8 Right-J Worksheet Job: ZONE #1 Date: Apr 28, 2005 �� DRAWDY RESIDENCE sy. QUICK CALCS, INC., 317 ST. LUCIE LN., Phone: 772-466-6799 1 Room name POWDER RECEPTION 2 Exposed wall 0.0 ft 17.6 ft 3 Ceiling height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 33.0 it 1.0 x 164.0 ft 5 Room area 33.0 ft' 164.0 ft2 Ty Construction U-value Or HTM Area (W) Load Area (ft2) Load number (Btuh/WF) (13tuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 0.143 n 4.00 2.55 0 0 0 0 16 16 64 41 1A-clom 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0 1A-clom 1.270 n 35.56 26.71 0 0 0 0 0 0 0 0 �d 13A-4ocs 0.143 ne 4.00 2.55 0 0 0 0 23 13 52 33 11 1A-clom 1.270 ne 35.56 48.57 0 0 0 0 0 0 0 0 I� 1A-clom 1.270 ne 35.56 70.43 0 0 0 0 10 0 341 675 13A-40gs 0.143 a 4.00 2.55 0 0 0 0 64 19 75 48 IA-clom 1.270 a 35.56 62.25 0 0 0 0 0 6 0 0 IA-clom 1.270 a 35.56 91.12 0 0 0 0 0 0 0 0 1A-clom 1.270 a 35.56 91.12 0 0 0 0 0 0 0 0 10A-m 1.670 a 46.76 53.19 0 0 0 0 45 0 2120 2411 V}J 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 23 13 52 33 L-G IA-ciom 1.270 se 35.56 70.95 0 0 0 0 10 10 341 333 Val 13A-4ocs 0.143 s 4.00 2.55 0 0 0 0 16 16 64 41 1A-clom 1.270 s 35.66 37.88 0 0 0 0 0 0 0 0 L~_{G; 1A-clom 1.270 s 35.56 37.88 0 0 0 0 0 0 0 0 IW 13A-4ocs 0.143 sw 4.00 2.55 0 0 0 0 0 0 0 0 - 7A-lgsnn 0.600 sw 16.80 33.58 0 0 0 0 0 0 0 0 13A-4ocs 0.143 w 4:00 2.55 0 0 0 0 0 0 0 0 1A-clom 1.270 w 35.56 62.25 0 0 0 0 0 0 0 0 lAclom 1.270 w 35.56 69.17 0 0 0 0 0 0 0 0 10A-m 1.670 w 46.76 42.33 0 0 0 0 0 0 0 0 10A-m 1.670 w 46.76 53.19 0 0 0 0 0 0 0 0 ID-c2om 0.870 w 24.36 77.43 0 0 0 0 0 0 0 0 1A-clom 1.270 w 35.56 91.12 0 0 0 0 0 0 0 0 �i 13A-4ocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 �--G 7A-1gsnn 0.600 nw 16.80 32.93 0 0 0 0 0 0 0 0 I-C IA-clom 1.270 nw 35.56 48.57 0 0 0 0 0 0 0 0 P 12C-Osw 0.091 - 2.55 1.28 0 0 0 0 0 0 0 0 C 1613-30ad 0.032 - 0.90 1.68 33 33 30 55 164 164 147 276 C 1713-6al 0.105 - 2.94 4.57 0 0 0 0 0 0 0 0 F 22A-tph 1.358 - 38.02 0.00 33 0 0 0 164 18 669 0 6 c) AED excursion -8 -445 Envelope loss/gain 30 48 3924 3445 12 a) Infiltration 0 0 338 86 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 1200 0 0 0 0 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 15 24 0 0 14 Subtotal 45 72 4262 3531 15 Duct loads 9% 19% 4 14 9% 19% 389 684 Total mom load 49 86 1 4651 4215 Air required (cfm) 3 5 255 226 Printout certified bV ACCA to meet all requirements of Manual J 8th Ed. wr�9 htsoft Right -Suite Residential 5.9.56 RSR31845 2005-May-03 10:47.41 ACCA C:WIy DocumentslWrightsoft HVACIDRAWDY RESIDENE.rrp Calc = MJ8 Orientation = E Page 9 :. :. Right-J Worksheet = ZONE #1 DRAWDY RESIDENCE QUICK CALCS, INC., 317 ST. LUCIE W., Phone: 772-466.6799 Job: Date: Apr 28, 2005 By: 1 Room name STUDY 2 Exposed wall 16.0 ft 3 Ceiling height 10.4 ft heaVcool 4 Room dimensions 1.0 x 200.5 ft 5 Room area 200.5 ft Ty Construction number U-value (Btuhlft-F) Or HTM (B Area (ft2) or perimeter (ft) Load (Btuh) Area or perimeter Load Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 0.143 n 4.00 2.55 0 0 0 0 1A-c1om 1.270 n 35.56 34.77 0 0 0 0 IA -clam 1.270 n 35.56 25.71 0 0 0 0 Wi 1ocs 3A-fl 0.143 ne 4.00 2.55 0 0 0 0 11 ;- G IA-clom 1.270 ne 35.56 48.57 0 0 0 0 l-G 1A-clom 13A-4ocs 1.270 0.143 ne a 35.56 4.00 70.43 2.55 0 128 0 107 0 428 0 272 1A-c1om 1.270 a 35.56 62.25 0 0 0 0 1A-clom 1.270 a 35.56 91.12 15 0 533 1367 1A-clom 1.270 a 35.56 91.12 6 0 213 547 10A-m 1.670 a 46.76 53.19 0 0 0 0 W, 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 G 1A-clom 1.270 se 35.56 70.95 0 0 0 0 Vrl 13A-4ocs 0.143 s 4.00 2.55 0 0 0 0 1A-clom 1.270 s 35.56 37.88 0 0 0 0 L{-�G 1A-c1om 1.270 s 35.56 37.88 0 0 0 0 13A-4ocs 0.143 sw 4.00 2.55 0 0 0 0 7A-1gsnn 0.600 sw 16.80 33.58 0 0 0 0 W 13A-4ocs 0.143 w 4:00 2.55 0 0 0 0 1A-c1om 1.270 w 35.56 62.25 0 0 0 0 1A-clom 1.270 w 35.56 69.17 0 0 0 0 10A-m 1.670 w 46:76 42.33 0 0 0 0 10A-m 1.670 w 46.76 53.19 0 0 0 0 1D c2om 0.870 w. 24.36 77.43 0 0 0 0 r. IA-clom 1.270 w 35.56 91.12 0 0 0 0 VrJ 13A-40cs 0.143 nw 4.00 2.55 0 0 0 0 7A-1gsnn 0.600 nw 16.80 32.93 0 0 0 0 I�_GG 1A-clom 1.270 nw 35.56 48.57 0 0 0 0 P 12C-0sw 0.091 - 2.55 1.28 0 0 0 D C 16B-30ad 0.032 - 0.90 1.68 0 0 0 0 C 1713-6al 0.105 - 2.94 4.57 228 228 671 1042 F 22A-tph 1.358 - 38.02 0.00 201 16 608 0 6 c) AED excursion -270 Envelope loss/gain 2454 2958 12 a) Infiltration 306 78 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances @ 1200 0 0 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 2761 3036 15 Duct loads 9% 19%1 252 588 Total room load 3012 3624 Air required (cfm) 165 194 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wrraghtsoFt Right-SuReResidential5.9.56RSR31845 2005•May-0310:47*41 ACCA C:WIy DocumenLs\Wrightsoft HVACIDRAWDY RESIDENE.rrp Calc = MJ8 Orientation = E Page 10