Loading...
HomeMy WebLinkAboutAPPROVED, Titanium PSU #30 Underlayment FL11602-R10$CIS Home Log Ln User Registra-0,0n HDtTOPiCS submit Surcharge Sta'S & Facts d0orProduct Approval IMER' Public User Product uppEn rat P ca on Detail > icatimn Search > ga A - 11 ti W > A pli ft FL FL11602-Rill # Application Type Revision Code Version 2017 Application Status Approved Comments Archived Publitatinns Contact US SCIS Site MZP Unks Search Product Manufacturer Owens Corning Roofing and Asphalt, LLC Address/Phone/Email One Owens Corning Parkway Toledo, OH 43645 (740) 321-6345 Greg. Keeler@owenscoming, corn Authorized Signature Keeler Greg Greg, KeelerCc0owenscoming.com Technical Representative Greg Keeler Address/Phone/Email 2790 Columbus Road Granville, OH 43023 (740) 321-634$ greg.keeter@owenscorning.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Undarlayment-t Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name Who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity Quality Assurance Contract Expiration Date 12/3112020 Validated By John W. Knezevich, PE -' Validation Checklist - Hardcopy Received Certificate ofIndependence fiz �'-R �OCQT �211 Referenced Standard and Year (of Standard) Standard Year ASTM D1970 2015 ASTM D226 (physicals) 2009 ASTM D4798 2011 FRSAITRI April 2012 2012 TAS 117(B) 1995 UL1897 2012 I Equivalence of Product Standards Certified By Sections from the Code Product Approval method Method I Option D Date Submitted 10117/2019 Date Validated 10/17/2019 Date Pending FBC Approval 10/20/2019 Date Approved 12/10/2019 Summary,, of Products FL # Model, Number, or Name 11602 1 Titanium Roof Underlayments Limits of Use Approved for use in HVHZ. No Approved for use outside "VHZ: Yes Impact Resistant. N/A Design Pressure; +N/Af-45 Other. 1.) The design pressure noted herein pertains to use of a specific underlayment system beneath foam -on the sytsems. Refer to ER Section 5.6.3 for details. 2.) Refer to ER Sections S and 6 for other Umits of Use. Description Synthetic sheet -type roof underlayments Installation Instructions F I3-502 RIO 11 201E7 9 19 - , Verified By: Robert Nieminen PE-59166 Created by Independent Third Party: Yes Evaluation Reports FL11602 RIQ_AE 2019_jQ_jjLAL Created by Independent Third Party, Yes Contact US *, 26GI 3fair Stone Road, Tallahassee FL 32399 Phone: P50-487-1824. The State of Florida is an AAJEEO employer. _QpXn :qbt 2gQZ-2013 State of ejqrda. ; Flft4g, statement Accgsslbill tatemgZnt z: BgW_ZjLtsM= Unde, Florida law, email addresses are public records, if you do not want your e-mail address released in response, to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail, If you have any questions, please contact 850,487_1395.. 'Pursuant to Section 455.275(l), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emalls Provided may be used for offidat communicarfon with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public, To determine if you are a licensee under Chapter 455, F.S., please click tgq_. Product Approval Accepts* = = =VZ5 EEI = -Credv,_ iUard safe N E M 0 1 e',.'C Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 uf4 (203) 262-9245_ ENGINEER EVALUATE TEST CONSULT CERTIFY Owens Coming Roofing and Asphalt, LLC Evaluation Report 111980.11.08-Rll One Owens Corning Parkway FI-11602-1110 Toledo, OH 43659 Date of Issuance: 11103/2008 (740) 321-6345 Revision 11: 10/17/2019 SCOPE: This Evaluation Report is issued under Rule 61620-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume, The products described herein have been evaluated for compliance with the 61h Edition (2017) Florida Building Code sections noted herein. DESCRIPTiON: TitanjumT° Roof Underlayments LAMM: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE- This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEIVIO ETC, LLC requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOletc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPEMON: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages I through 8, Prepared by; Robert J.M. Nieminen, P.E. The facsimile sea[ appearing was autharized by Robert Florida Registration No. 59166, Florida VG4 ANEl983 A Nieminen, P.E. on 10/1712019. This does notserve as an Liectronicallysigned document. CERWICATION OF INDEPENDENCE' L NEW ETC, LLC does not have, nor does it Intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2, NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates, 3. Robert Nleminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product, 5, This is a building code evaluation, Neither MEMO ETC, LLC nor Robert Nieminen, P.E, are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for That , purpose, (02018 NEW ETC, LLC ROOFING COMPONENT EVALUATION: Product Category: Roofing Sub -Category. Underlayment Compliance Statement: Titanlurnrm Roof Underlayments, as produced by Owens Corning Roofing and Asphalt, LJC, have demonstrated compliance with the intent of the following sections of the 6' Edition (2017) Florida Building Code through testing in accordance with applicable sections the following Standards. Compliance is subject to the installation Requirements and Limitations / Conditions of Use set forth herein. Section ProStandard Xemar 1504.3.1 Wind Uplift UL 1897 2012 1507.1.1, R905.1.1 Exception 1507,1.1, R905.1.1 Exception 1507.11, T1507.1.1,1507.2.92 1507.3.3 TAS 110 TAS 110 Unrolling; Breaking Strength, Pliability Tear Strength Physical Properties Physical Properties Accelerated Weathering Pull -through resistance ASTM D226 2009 ASTM D1970 2015 ASTM 01970 2015 FRSA/TRI April 2012 (04-12) 2012 ASTM D4798 2011 TAS 217(B) 1995 Reference Date Enti Examination ERD (TST6049) Physical Properties 115010.04,09 04/29/2009 ERD (TST6049) Physical Properties 115010.05,10 05/14/2010 ERD (TST6049) Physical Properties Q55Z0.06.11 06/15/2011 ERD (TST6049) ASTM D276 138010.08AI 08/11/2011 ERD (TST6049) Wind Uplift 135520.08JI-1 08/12/2011 ITS(TST1509) ASTIVI D226 311801000Q-003 04/26/2007 ITS(TST1509) ASTM D226 3130639COQ-002A 08/21/2007 ITS(TST1509) Physical Properties 3126617COQ-005 10/3112007 ITS (TST1509) ASTM D226 101823107COQ-011 01/23/2015 ERD (TST6049) Physical Properties (NH) 4j-QC­19-SSUI)L-01.A 06/14/2019 Owens Coming PRI (TST58781 PRI (TST5878) PRI (T5T5670) PRI (TSTS878) PRI (TST5878) PRI (TST S878) PRI (TSTS978) PRI (TST5978) PRI (TST5878) RRI (TST5878) PRI (T5TS9781 PRI (TST5878) PRI (TSTS878) ITS (QUA1673) ITS (QUA1673) NIEMO ETc, iLc Cert&vte afAurhor;zatfon #32455 Product equivalency Declaration 06/1$/2018 ASTM 01970 OCF-341-02-01 09/20/2017 ASTM D1470; Tear strength GCF-331-02-02 10/03/2017 ASTM V11270; T001 VtNrlaMh 10,'038/2017 ASTM D1970, Tear strength OCF-334-02-02 10/03f2017 FRSA/TRI April 2012 (04-12), partial QCF-343-02-01 11/09/7017 ASTM D4798 OCF-341-02-01 11/27/2017 TAS 117(6); Puli-through OCF-422-02-02 04103/2018 FRSAJTRl April 2012 (04-12), partial OCF-425-02-01 08/13/2018 ASTM D226 I ASTM D4798 OCF-331-02-01 RI 05107/2019 ASTM 0226 ASTM D4798 OCF-332-02-01 RI 05f07/2019 ASTM D226 ASTM D4798 OCF-334-02-01 RI 05/07/2019 UL1897 1379T002 07/10/2019 Tensile adhesion OCF-507-02-01 08/13/2019 Quality Control ITS Listings Current Quality Control Service Confirmation 09/30/2017 Evaluation Repast 11198G.11.08-Ril 6rm EDITION (2017) FSC NOVA WK VALUATION FLI-2692-RIO Tdanium Roof Underisyments RevWon 11: 10/17/2019 Page 2 of a "FNEryioletc. Produ Specification Plan ) Pmfieum 4.1 Titanium' PSU-30 ASTM D1970 Dubai, UAE & unreinforced polymer modified bitumen material adhered and FRSA/TRI Brentwood, NH to the underside of a polymer -coated, synthetic woven April 2012 sheet. The underside is backed with a release film. Unit weight 24 lbs/square 4.2 TItaniUMT11 UDL-25 FBC 1507-1.1 Qingdao, China synthetic sheet -type underlayment comprised of a woven & R90511.2 core coated on one side With a polymer coating, Unit (Exception) weight 2.5 tbs./square 43 Titanium'"' UDL-30 FBC 1507.1.1 Mission, BC, synthetic sheet -type underlayment comprised of a woven & 8905.1.1 Canada & core coated on both sides with a polymer coating. Unit (Exception) Qingdao, China weight 4.0 lbs./square 4.4 Titanium"" UDL-50 FBC 3.507.1.1 Mission, BC, synthetic sheet -type underlayment comprised of a woven & R905.1.1 Canada & core coated on both sides with a polymer coating. Unit )Exception} Qingdao, China weight 4.7 ibs./square 5.1 This is a building code evaluation. Neither MEMO ETC, LLC nor Robert Merninen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5,2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Titanium"' Roof Underlayments may be used with any prepared roof cover where the product Is specifically referenced within FBC approval documents. if not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: TABLE 1; ROOF COVER OPTIONS Asphalt i Wood Shakes asnderiaymenc Shingles Nall -On Tile Foam -On Tile Metal & Shingles Slate Titanium PSU-30 Yes yes Yes (See 5.5J) Yes Yes Yes Titanium UDL-25 Yes No No Yes Yes Yes Yes Yes Titanium UDL-30 Yes (Oawshc .8012-Ply (sase sheet in 2-Ply Yes Yes Yes system) I Titanium UDL-50 Yes No No Yes L Yeses yes Ncmo gr C, *-LC Evaluation Report 112990-11-08-RII certificate afAwho62ation #32455 401 EDMON (20171 F8C NON-MVNZ EVAWATION R.11602-=, Titanium Roof Underlay-ents Revision 11: 10/17/2019 Page 3 of 8 ONEmojetc. 6.3.3 Slopes of 4:12 or greater. End (vertical) laps shall be minimum 6-inches and side (horizontal) laps shall be minimum 4-inches. End (vertical) laps shall be offset from course to course not less than 6 feet. Minimum attachment shall be in accordance with F8C Table 15071.1 or R905,1.1. When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily attached pending attachment of the battens, 6,14 Slopes of 2:12 to less than 4:12: End (vertical) laps shall be minimum 12-inches and side (horizontal) laps shall be minimum 25-inches. End (vertical) laps shall be offset from course to course not less than 6 feet. Begin by fastening a 25-inch wide strip along the eaves. Place a full -width sheet over the starter, completely overlapping the starter course. Continue upslope, rnaintaining minimum 25-Inch side (horizontal) laps, resulting in a double -layer application. Minimum attachment shall be In accordance with F8C Table 1507.1.1 or R905.1.1. Secure end laps 4-inch o.c, When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily attached pending attachment of the battens. 6.4 Titanium' PSI!-30: 6A.1 N Dns: Shall be installed in compliance with the codified requirements for ASTM 01970 underlayment in FBC Table 1507,1,1 for the type of prepared roof covering to be installed, and Owens Corning published requirements. Titanium"' PSU-30 shall be back -nailed in accordance with Owens Coming published installation requirements. 6.4.2 Nail -On- Tile Applications: Shall be installed in compliance with the requirements for Self -Adhered Membrane underlayment set forth in FRSA/TR1 April 2012 (04-12), and Owens Corning published requirements. Titanlum'4 PSU-30 shall be back -nailed max. ' o.c. with 12 ga. galvanized annular rink shank nails through 32 ga., 1-5/8-inch diameter tin caps in accordance with Owens Corning published installation requirements. Refer to Section 5.8 for the staging limitations. 6.4.3 Foam -On Tile Applications: Shall be installed in compliance with the requirements for Self Adhered Membrane underlayment set forth in FRSA/TRl April 2012 (04-12), and Owens Corning published requirements. Titanium"" PSU-30 shall be back -nailed max- 6" o_c_ with 12 ca- oalvaninmcl annular rink shank nails through 2� ga-, I-SJR-Inch diameter tin cans in accordance with Owens Corning published installation requirements. Refer to Table 1A for allowable tile adhesives, Refer to Section 5.6.1 for wind uplift limitations. Refer to Section 5,8 for the staging limitations, f 6.5 nitaril-um 2-Ply system: 6.5.1 The Titanium 2-Ply System consists of a base layer of Titanium UDL-30 (top -surface --primed or sheet inverted) mechanically attached to the wood roof deck followed by Titanium PSU-30, self -adhered. 6-5.2 Non Tile Applications, Install Titanium UDL-30 (top surface primed or sheetinverted) in accordance with Section 6.3 followed by Titanium PSU-30 in accordance with Section 6,4. �ICN70 E-.,C, i.Lc Evaluation Report 111980.11,08-R3.1 Cert;ffmta ofAurharization #32455 e EDMON (2017) IrliC N10N-FVhZ EVALUKrION Titaniertn Roof Underlayments Revision 11., 10117/2019 Page 7 of 8 IFAVIIE Mo 1, etc. 6.53 Nail -On Tile Applications, For nail -on the Installations, install Titanium UM-3D (top surface primed or sheet inverted) in accordance with FRSA/TRI April 2012 (04-12), using Section 6.3 as a guide, and considering the wider sheet width relative to ASTM D226 felt. Then apply Titanium PSU-30 in accordance with Section 6.4, Refer to Section 5.8 for the staging limitations. 6.5.4 Foam -On Tile Applications: For foam-vn the installations, install Titanium UAL 30 (top surface primed or she -at inverted) in accordance with Section 5.6.1 herein. Then apply Titanium PSU-30 in accordance with Section 6.4 Refer to Table 1A for allowable the adhesives. Refer to Section 5.61 for wind uplift limitations. Refer to Section 5.8 for the staging limitations. dim As required by the Building Official or Authority Having Jurisdiction in order to property evaluate the installation of this product 8. MANUfACTURING PtANTS: Contact the manufacturer or the named QA entity for plants covered under Rule 5IG20-3 QA requirements. Refer to Section 4 herein for product & production locations having met codified physical properties specifications. Intertek Testing Services NA Inc. — QUA1673; (604) 520-3321 - END OF EVALUATION REPORT - NEW ETC, tic Evaluation Report 111990.1LOO-R11 C1?rV)7Mt,-ofAvthanzafton 032455 0 EWTION (2017) FBC EVALUATION Titanium Roof Underlayments Revision 21- 10/1712019 1 Page 8 of 8