Loading...
HomeMy WebLinkAboutAPPROVED,Metal Sales 26GA Metal RoofingEVALUATION REPORT OF METAL SAFES MAN-UlFACTURING CORPORATION `26 GA. LMAGE II PA_NNEL' FLORIDA BUILDING CORE 6TII EDITION (2017) FLORIDA PRODUCT APPROVAL FL 14645.12-R3 ROOFING METAL ROOFING Prepared For: Metal Sales Manufacturing Corporation 545 South 3Fd Street, Suite 200 Louisville, IY 40202 Telephone., (502) 855-4300 Fay:: (502) 855-4200 Prepared By: Bala Sockalingam, Ph.D., P.E. Florida Professional Engineer #62.240 1216'ti Lansing Ave., Suite C Tulsa, OR 74106 Telephone: (918) 492-5992 FAX: (866) 366-1543 This report consists of Evaluation Report (3 Pages including cover) 1, a M M#fgt'. Installation Details (I Page) ����� S�C�i �f ���e, Load Span 'fable (1 Page) ,�'°� ��� •`� G E tV 3 � •��,.�� No 62240 .�y '' STATE OF Report No. C2182-12 Date: 9.9.17 FL 14645.12-R3 C2182-12 9.9.17 Page 2 of 3 Manufacturer: Metal. Sales Manufacturing Corporation Product Name: Image H Panel Description: Max. 16" wide coverage with 1" high ribs Materials: Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). Deck Description: Min. 7116" thick OSB or min. 15i32" thick Plywood or min. 1/4" thick wood plank (min SG of 0.42) for new and existing constructions. Designed by others and installed as per FBC 2017. Deck Attachment: 8d x 2.5" long ring shank nails or #8 x 2" long wood screws @ 6" o.c. (Minimum) in the plywood field and edges. Designed as per FBC 2017. New Underlayment: Minimum underlayment as per FBC 2017 Section 1507.4.5.1. Required for new construction and optional for reroofing construction. Existing Underlayment: One layer of asphalt shingles over one layer of #30 felt. For reroofing (Optional) construction only. slope: 112:12 or greater in accordance with FBC 2017 Section 1507.4.2. Requires applied lap sealant for roof slopes less than 3:12. Allowable Uplift Load: 20.8 psf @ fastener spacing of 24" o.c (Factor of Safety = 2) 63.5 psf @ fastener spacing of 6" o.c 86.55 psf @ fastener spacing of 6" o.c with 318" bead adhesive in panel sidelap Fastener Pattern: #10 pancake head screws along panel seam. Fastener shall be of sufficient length to penetrate through the deck a minimum. of %4". Sidelap Adhesive: Schnee -Morehead SM7108 Permathane adhesive Test Standards: Roof assembly tested in accordance with UL580-94 (Rev 98) `Uplift Resistance of Roof Assemblies' &. UL1897-98 'Uplift Tests for Roof Covering Systems'. Test Equivalency: The test procedures in UL 580-94 comply with test procedures prescribed in UL 580-06. The test procedures in UL 1897-98 comply with test procedures prescribed in UL 1897-12. Code Compliance: The product described herein has demonstrated compliance with FBC 2017 Section 1507.4 FL 14645.12-R3 C2182-12 9.9.17 Page 3 of 3 Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. The design pressure for reduced fastener spacing may be computed using rational analysis prepared by a Florida Professional Engineer or lased on Metal Sales load span table. This evaluation report is not applicable in High Velocity Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to FBC 2017 Section 1505 and current approved roofing materials directory or ASTM E 1081UL790 report from an accredited laboratory for fire ratings of this product. Supporting Documents: UL580AJL 1897 Test Reports Farabaugh Engineering and Testing Inc. Project No. T176-11, Reporting Date 4126/11 Project No. T260-11, Reporting Date 8/ 15/ 11 oyoO Ju°ns���r---LssanNuur£ unnooVsS fig* M J �z d�Ly"n _ �aw by U CV CL n Nn 40. p Y LL ][ J WCf m15 WtaJy N ry x p x ;4e � 6 Ld co 6 U L� a w o u � y :Ksz 2 2 _ 0 ell �¢ N F6 J N _ U2 It 4! W 2 O R 2-6 5MI''L )o Nslru "(1W 'Vft' r xA iliE15 M yyJg9 yy OntoS1y3�lIlG Q Ring N �y fA wm ON � 4a i 16 N � r m 16 o Cam] N Q C 4c Z METAL SALES -MANUFACTURING CORPORAT ON Image 11 Uplift Loads (IMin, 26 ga.) Description a Fastener Spacing along Panel Leng-th Allowable Uplift Load (Psf) Coverage width: 16" 6 63.5 -- - Panes Fastener: - - 10 - -- 49.8 - - #10-12 Pancake head screws � 1 � 41 5 - 14 35.6 16 - - 31.1 -- - _ 18 Z7.7 24.9 With Sidelap Sealant 6 96.55 Hates: I . The bold numbers indicate designs loads calculated from test data with aafett factor of I 2. Panels must be installed as per Evaluation Report FL 14645-12 and Metal Sales current installation procedure. I Three or more spans condition. 12 16 N Lansing Ave.. Suite C Tulsa. dk 74106 918 492 599= Ncl 62240 "• 0 :• S TAT E G F +� .pc) t-7 Bala Sockaling-am, Ph.D., P.E. FL 62240