�,°m•$&•;4;�,,,r��d�,r' ,rrji �� FL # FL10758-117
Application Type Revision
Code Version 2017
Appiicatior Status Approved
Comments
Archived
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo, OH 43659
(740)404-7829
g re g. kee ler@ow e ns co rn i ng . com
Authorized Signature Greg Keeler
greg. keeier@owenscorn ing.com
Technical Representative Greg Keeler
Address/Phone/Email 2790 Columbus Road
Granville, OH 43023
(740)321-5345
greg.keeler@owenscarnfng.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Roofing Accessorles that are an Integral Part of the Roofing System
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Zachary R. Priest
the Evaluation Report
Florida License PE-74021
Quality Assurance Entity uL LLC
Quality Assurance Contract Expiration Hate 10/13/2020
Validated By Locke Bowden RE.
Validation Checklist - Hardcopy Received
Certificate of Independence FL1a758 R7-1.,-,QI_QCR14003.3 2Q 17 FBC Evaluation Roort Owens
Cornin Ven fin i.pijf
Referenced Standard and Year (of Standard)
https://www,ficridabullding.org/or/pr-app_dtl.aspx?param=wGEVXQwtDgvldAvlte0Y0%2bC3zFtrydg9NkhwZwZzJrupAl5CIMPINHQ%3d/2d Page I of 3
Equivalence of Product Standards
Certified By
Sections from the Code
1708.2
Product Approval Method Method 2 Option B
Date Submitted 09/30/2017
Date Validated 10/04/2017
Date Pending FBC Approval 10/08/2017
Date Approved 12/12/2017
Summary of Products
FL #
Model. Number or Name
Description
10758.1
VentSure 4-Foot Strip Heat and
Copolymer plastic low profile attic ridge vents for installation
Moisture Ridge Vents
in shingle roof systems
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL10758 R7 II 4 R14 0 .3 Z 7 FB Evaluation Rep)rt
Approved for use outside HVHZ: Yes
Owens Corning Vents fins—da,f
Impact Resistant: N/A
Verified By: Zachary R. Priest 74021
Design Pressure: N/A
Created by Independent Third Party; Yes
Other: Refer to evaluation report
Evaluation Reports
FL10758 F�A�_(�CR_l�}{�Q'�.3_ 47 7 FBC Evaluation Rep_Q
Owens Corning V n n 1,=
Created by Independent Third Party: Yes
10758.2 VentSure Low Profile Slant Back
Galvanized metal roof vent
Roof Vent With Exterior Louver
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL10758_117 I[ _pCR14003,3 2017 FBC Evalua. ion R gar
Owens Corninq ygjgts final.ndf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest 74021
Design Pressure: N/A
Created by Independent Third Party; Yes
Other: Refer to evaluation report,
Evaluation Reports
FL_ 17 —R7 AE OCR14003.3 2017 FBC Evaluation Re or
Owens Corning Vents final.pdf
Created by Independent Third Party: Yes
10758.3 VentSure Rigid Roll Ridge Vent
Ridge Ventilation System
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
EL�7U_aZ_ II OCR140n3.3 2017 FBG-Evaivaieion_Report
Owens Corning Vents_final,pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest 74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: Refer to evaluation report.
Evaluation Reports
FL1075$ R7 A7ORi4003,3 2017 FBC Evaloatian &EQr
Owens Corning Vents firial.pdf
Created by Independent Third Party: Yes
;pack NeuC
Contact Us :: 2601 Slair Stone Road. Ta labassee FL 32399 Phone: 650-487-1824
The State of Florida is an AA/EEO employer. CopVrialht 2007-201.3 State of Florida. :: Privacy Statement :: Accessibility Statement :: R nent
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -retards request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. 'Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The email$ provided may be used for official communication with the licensee However email addresses due public record. If you do not wish to supply a
personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a ficensee under Chapter
455, F.S., please click here .
https://www-floridabuilding.org/pr/pr_app_dtl-aspx?param=wGEVXQwtDgvrldAvlleOYO%2bC3zFtrydg9NkhwZWZzJrupAl5CIMPWHg/3d%3d Page 2 of 3
Product AppM"l Accepts:
®® e.
Credit Card
,safe
https://www_flor! dabuiIdin g.org)prfpr_app_citI.aspx?pa ramkhwZWZzJrupAY5ClMPWHQ/3d13d Page 3 of 3
Certificate of Authorization No. 29824
CREEK
' 17520 Edinburgh Dr
G Tampa, FL 33647
:.;•_;ry TECHNICAL SERVICES, LLC ($13) 4$0 3421
,Y
EVALUATION REPORT FLORIDA BUILDING CODE, 63T" EDITION (2017)
Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued September30, 2017
1 Owers Corning Parkway
Toledo, OH 43657
(800) 439-7465
www,owe n s co ruing. com
Quality Assurance: LIL LLC (QLIA9625)
SCOPE
Category: Roofing
Subcategory; Roofing Accessories that are an Integral Part of the Roofing System
Code Sections: 1708.2
Properties: Roof Ventilation
REFERENCES
En it
Report No.
Standard
Year
Architectural Testing, Inc (TST1558)
01-38660.04
TAS 100(A)
1995
Architectural Testing, Inc (TST1558)
01-38560.05
TAS 100(A)
1995
Architectural Testing, Inc (TST1558)
C1774.01-109-18
TAS tOO(A)
1995
ASTM D 635
2010
ASTM D 1929
2012
ASTM D 2843
2010
PRI Construction Materials Technologies (TST5878)
AVIG-005-02-01
ASTM D 635
2010
ASTM ❑ 1929
2012
ASTM D 2843
2010
PRE Construction Materials Technologies (TST5878)
AVIG-006-02-01
ASTM G 155
2005a
PRI Construction Materials Technologies (TST5878)
0CF-111-02-01
ASTM D 635
2010
ASTM D 1929
2012
ASTM D 2843
2010
PRE Construction Materials Technologies (TST5878)
❑CF-112-02-01
ASTM G 155
2005a
PRI Construction Materials Technologies (TST5878)
OCF-116-02-01
TAS 1 DO(A)
1995
PRI Construction Materials Technologies (TST5878)
OCF-223-02-01
TAS 1 DO(A)
1995
PRI Construction Materials Technologies (TST5878)
OHI-007-D2-01
TAS 100(A)
1995
0CR14003.3 FL10758-R7 Page 1 of 5
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3_ The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
c- . AA --A haro.n
CREEKtill
TECHNICAL SERVICES. L.LC
PRODUCT DESCRIPTION AND APPLICATION
OWENS CORNING ROOFING AND ASPHALT LLC
VentSure@ Roof Ventilation
VentSure� 4-Foot Strip 1-114' x 14-718" x 48" low -profile attic ridge vent consisting of a two -layer nylon -
Heat and Moisture Ridge polyester composite. Available with or without a polyester fabric moisture barrier for
Vents; installation in shingle roof systems_
48"
�i#Fi>If�"flo, 411 141:100 4 Ift i `1110 41111111.1 IX39IAi .0IFIII W111I.M.11IfIIIl;ll[''IHI;' 1Wno1111111 i:11: M
I�
I
i 1�1 n11e€;ii�3 i'1 +:111 ]'SS1.l 11i111•I I�J:I:'1i111� 1! 11 11 �i ■1 i.n 1 11 IJ !'11 1' l H 1l■ 1�1114 11 !. �!.l�I.I*..i 1.
Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing
construction. Roof deck shall be designed and installed in accordance with FBC.
requirements.
Roof slope: Minimum 3:12 to maximum 16/12
Installation Height: Maximum 60-ft
Attachment Method: Cut a 2-inch opening (11-inchon each side of the ridge) centered in the deck at the
ridge for ventilation_ The slot shall terminate approximately 6-inches from the rake
edges. Apply a Y,-inch wide bead of ASTM o 4586 roofing cement along the entire
length of the outside edges of the vent to seal the vent to the field shingles, taking
care to not completely cover the weep slots in the vent. Center the vent over the
opening and fasten to the deck using the 11 ga. 2'/-inch galvanized ring shank nails
(shall comply with FBC Section 1506.5) provided with the vent. Fasteners are to be
installed on both sides of the vent 1, 12, 24, 36, and 47-inches from the start of each
vent piece.
Prepare the adjacent vent section by applying the roofing cement along the edges,
snap together with fixed vent, and fasten to the deck in the same manner as the first
section_ Fasten the ridge shingles over the vent to the deck on the marked "shingle
nail line" with two (2) minimum 11 ga. 2/z-inch galvanized ring shank roofing nails
(shall comply with FBC Section 1506.5) provided with the vent or as directed by the
shingle manufacturer's installation instructions.
Allowable Roof Coverings: Asphalt shingles
OCRI4003.3 FL10758-R7 Page 2 of 5
This evaluation report is provided for State of Fbrida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
---- PF..--III.. d 4 1 o—i-
CREEK�7 C� K OWENS CORNING ROOFING AND ASPHALT LLC
VentSure® Roof Ventilation
TECHNICAL SERVICES. LLC
VentSure' Low Profile 18" x 24" x 2-3I16' (32" x 23" flange base) static off -ridge vent composed of ASTM
Slant Back Roof Vent A653 galvanized steel (available with painted finish). Material shall conform with
with Exterior Louver: FBC Section 1507.4.3.
_...__,.._..— _, .. -.f•
W 4�
I
OCrT
Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing
construction_ Roof deck shall be designed and installed in accordance with FBC
requirements.
Roof slope: Minimum 3:12
Installation Height: Maximum 33-ft
Attachment Method: Cut an 11 x 11-inch hole through wood sheathing only approximately 18-inches from
the ridge. Apply 1/4-inch thick by 3-inch wide bed of ASTM D 4586 roofing cement
around inner and outer flange. Place vent directly over the hole, ensuring the vent
sits flat on the roof. Fasten vent flinches o.c. and 1-inch from outside edge of flange
with minimum 12 ga. ring shank roofing nails (shall comply with FBC Section
1506.5), ensuring Y inch penetration through wood deck (Minimum 18 nails per
vent).
Install baffle in '/.-inch bed of ASTM D 4586 roofing cement and secure with
minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5)
spaced 8-inches o.c. (total of (3) nails) while ensuring %-inch penetration through
wood deck. Seal all nails and vent flange with ASTM D 4586 roofing cement_
Allowable Roof Coverings: Asphalt shingles
OCR14003.3 FL1 d758-R7 Paoe 3 of 5
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shalt notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
' ^> CREEK
E �h j OWENS CORNING ROORNG AND ASPHALT LLC
VentSure@ Roof Ventilation
TECHNICAL SERvicEs, LLC
VentSure'' Rigid Roil 519" x 11-114' x 20' attic ridge vent composed of high density polypropylene with a
Ridge Vent: spun -bond polypropylene fabric.
2#
Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing
construction. Roof deck shall be designed and installed in accordance with FBC
requirements.
Roof slope: Minimum 2:12 to maximum 20:12
Installation Height: Maximum 60-ft
Attachment Method: Cut a 2-inch opening (1-inch on each side of the ridge) centered in the deck at the
ridge for ventilation. The slot shall terminate approximately 12-inches from the rake
edges_ Apply a continuous bead of polyurethane adhesive sealant along the entire
length of the outside edges of the vent to seal the vent to the field shingles. Center
the vent over the opening and fasten the vent 24-inches o.c. to the deck using
minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5),
ensuring %-inch penetration through wood deck.
Fasten the ridge shingles over the vent to the deck on the marked 'shingle nail line"
with two (2) minimum 12 ga. ring shank roofing nails (shall comply with FBC Section
1506.5) or as directed by the shingle manufacturer's installation instructions,
ensuring %-inch penetration through wood deck. Outside edges of the shingles shall
be sealed with flashing cement.
Allowable Roof Coverings: Asphalt shingles
LIMITATioNs
1) Fire Classification is outside the scope of this evaluation.
2) This report is not for use in the HVHZ.
3) The roof deck and deck attachment shall be designed by others in accordance with the FBC.
4) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
5) Owens Corning vents shall be installed in strict compliance with this evaluation report and the
manufacturer's published installation instructions. In the event of conflict, the more restrictive installation
shall be enforced.
5) Deck substrates shall be clean, dry, and free from any irregularities and debris_ All fasteners in the deck
shall be checked for protrusion prior to installation.
7) Installation of the roof assembly is outside the scope of this evaluation.
8) Owens Corning vents are intended to provide passive ventilation for an enclosed attic in residential
construction applications.
OCR14003.3 FL10758-R7 Paae 4 of 5
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
�..o..IFII" h-m
CREEK
TECHNICAL SEFZVICES, LLC
COMPLIANCE STATEMENT
OWENS CORNING ROOFING AND ASPHALT LLC
VentSure® Roof Ventilation
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 6th Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
R.
No 74021
STATE OF
CERTIFICATION OF INDEPENDENCE
2 017.09.3 0
15:16:17
-041001
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation_
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire. a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT