Loading...
HomeMy WebLinkAboutPA FL10758-R7'. N Business & Professional Regulation BUS Home Log In user Registration � HotToples Submit Surcharge Star & FaCs Publications Contact Us � BCIS Site Map Unks Search b' Product Approval '. -USER: Public User re NC4ALa-&Qlis• i�LlseaNh > Application List > Application Detail rmeyrnNGlhl� il'�h:. �,°m•$&•;4;�,,,r��d�,r' ,rrji �� FL # FL10758-117 Application Type Revision Code Version 2017 Appiicatior Status Approved Comments Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo, OH 43659 (740)404-7829 g re g. kee ler@ow e ns co rn i ng . com Authorized Signature Greg Keeler greg. keeier@owenscorn ing.com Technical Representative Greg Keeler Address/Phone/Email 2790 Columbus Road Granville, OH 43023 (740)321-5345 greg.keeler@owenscarnfng.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Roofing Accessorles that are an Integral Part of the Roofing System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Zachary R. Priest the Evaluation Report Florida License PE-74021 Quality Assurance Entity uL LLC Quality Assurance Contract Expiration Hate 10/13/2020 Validated By Locke Bowden RE. Validation Checklist - Hardcopy Received Certificate of Independence FL1a758 R7-1.,-,QI_QCR14003.3 2Q 17 FBC Evaluation Roort Owens Cornin Ven fin i.pijf Referenced Standard and Year (of Standard) https://www,ficridabullding.org/or/pr-app_dtl.aspx?param=wGEVXQwtDgvldAvlte0Y0%2bC3zFtrydg9NkhwZwZzJrupAl5CIMPINHQ%3d/2d Page I of 3 Equivalence of Product Standards Certified By Sections from the Code 1708.2 Product Approval Method Method 2 Option B Date Submitted 09/30/2017 Date Validated 10/04/2017 Date Pending FBC Approval 10/08/2017 Date Approved 12/12/2017 Summary of Products FL # Model. Number or Name Description 10758.1 VentSure 4-Foot Strip Heat and Copolymer plastic low profile attic ridge vents for installation Moisture Ridge Vents in shingle roof systems Limits of Use Installation Instructions Approved for use in HVHZ: No FL10758 R7 II 4 R14 0 .3 Z 7 FB Evaluation Rep)rt Approved for use outside HVHZ: Yes Owens Corning Vents fins—da,f Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party; Yes Other: Refer to evaluation report Evaluation Reports FL10758 F�A�_(�CR_l�}{�Q'�.3_ 47 7 FBC Evaluation Rep_Q Owens Corning V n n 1,= Created by Independent Third Party: Yes 10758.2 VentSure Low Profile Slant Back Galvanized metal roof vent Roof Vent With Exterior Louver Limits of Use Installation Instructions Approved for use in HVHZ: No FL10758_117 I[ _pCR14003,3 2017 FBC Evalua. ion R gar Owens Corninq ygjgts final.ndf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party; Yes Other: Refer to evaluation report, Evaluation Reports FL_ 17 —R7 AE OCR14003.3 2017 FBC Evaluation Re or Owens Corning Vents final.pdf Created by Independent Third Party: Yes 10758.3 VentSure Rigid Roll Ridge Vent Ridge Ventilation System Limits of Use Installation Instructions Approved for use in HVHZ: No EL�7U_aZ_ II OCR140n3.3 2017 FBG-Evaivaieion_Report Owens Corning Vents_final,pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to evaluation report. Evaluation Reports FL1075$ R7 A7ORi4003,3 2017 FBC Evaloatian &EQr Owens Corning Vents firial.pdf Created by Independent Third Party: Yes ;pack NeuC Contact Us :: 2601 Slair Stone Road. Ta labassee FL 32399 Phone: 650-487-1824 The State of Florida is an AA/EEO employer. CopVrialht 2007-201.3 State of Florida. :: Privacy Statement :: Accessibility Statement :: R nent Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -retards request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. 'Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The email$ provided may be used for official communication with the licensee However email addresses due public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a ficensee under Chapter 455, F.S., please click here . https://www-floridabuilding.org/pr/pr_app_dtl-aspx?param=wGEVXQwtDgvrldAvlleOYO%2bC3zFtrydg9NkhwZWZzJrupAl5CIMPWHg/3d%3d Page 2 of 3 Product AppM"l Accepts: ®® e. Credit Card ,safe https://www_flor! dabuiIdin g.org)prfpr_app_citI.aspx?pa ramkhwZWZzJrupAY5ClMPWHQ/3d13d Page 3 of 3 Certificate of Authorization No. 29824 CREEK ' 17520 Edinburgh Dr G Tampa, FL 33647 :.;•_;ry TECHNICAL SERVICES, LLC ($13) 4$0 3421 ,Y EVALUATION REPORT FLORIDA BUILDING CODE, 63T" EDITION (2017) Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued September30, 2017 1 Owers Corning Parkway Toledo, OH 43657 (800) 439-7465 www,owe n s co ruing. com Quality Assurance: LIL LLC (QLIA9625) SCOPE Category: Roofing Subcategory; Roofing Accessories that are an Integral Part of the Roofing System Code Sections: 1708.2 Properties: Roof Ventilation REFERENCES En it Report No. Standard Year Architectural Testing, Inc (TST1558) 01-38660.04 TAS 100(A) 1995 Architectural Testing, Inc (TST1558) 01-38560.05 TAS 100(A) 1995 Architectural Testing, Inc (TST1558) C1774.01-109-18 TAS tOO(A) 1995 ASTM D 635 2010 ASTM D 1929 2012 ASTM D 2843 2010 PRI Construction Materials Technologies (TST5878) AVIG-005-02-01 ASTM D 635 2010 ASTM ❑ 1929 2012 ASTM D 2843 2010 PRE Construction Materials Technologies (TST5878) AVIG-006-02-01 ASTM G 155 2005a PRI Construction Materials Technologies (TST5878) 0CF-111-02-01 ASTM D 635 2010 ASTM D 1929 2012 ASTM D 2843 2010 PRE Construction Materials Technologies (TST5878) ❑CF-112-02-01 ASTM G 155 2005a PRI Construction Materials Technologies (TST5878) OCF-116-02-01 TAS 1 DO(A) 1995 PRI Construction Materials Technologies (TST5878) OCF-223-02-01 TAS 1 DO(A) 1995 PRI Construction Materials Technologies (TST5878) OHI-007-D2-01 TAS 100(A) 1995 0CR14003.3 FL10758-R7 Page 1 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3_ The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not c- . AA --A haro.n CREEKtill TECHNICAL SERVICES. L.LC PRODUCT DESCRIPTION AND APPLICATION OWENS CORNING ROOFING AND ASPHALT LLC VentSure@ Roof Ventilation VentSure� 4-Foot Strip 1-114' x 14-718" x 48" low -profile attic ridge vent consisting of a two -layer nylon - Heat and Moisture Ridge polyester composite. Available with or without a polyester fabric moisture barrier for Vents; installation in shingle roof systems_ 48" �i#Fi>If�"flo, 411 141:100 4 Ift i `1110 41111111.1 IX39IAi .0IFIII W111I.M.11IfIIIl;ll[''IHI;' 1Wno1111111 i:11: M I� I i 1�1 n11e€;ii�3 i'1 +:111 ]'SS1.l 11i111•I I�J:I:'1i111� 1! 11 11 �i ■1 i.n 1 11 IJ !'11 1' l H 1l■ 1�1114 11 !. �!.l�I.I*..i 1. Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing construction. Roof deck shall be designed and installed in accordance with FBC. requirements. Roof slope: Minimum 3:12 to maximum 16/12 Installation Height: Maximum 60-ft Attachment Method: Cut a 2-inch opening (11-inchon each side of the ridge) centered in the deck at the ridge for ventilation_ The slot shall terminate approximately 6-inches from the rake edges. Apply a Y,-inch wide bead of ASTM o 4586 roofing cement along the entire length of the outside edges of the vent to seal the vent to the field shingles, taking care to not completely cover the weep slots in the vent. Center the vent over the opening and fasten to the deck using the 11 ga. 2'/-inch galvanized ring shank nails (shall comply with FBC Section 1506.5) provided with the vent. Fasteners are to be installed on both sides of the vent 1, 12, 24, 36, and 47-inches from the start of each vent piece. Prepare the adjacent vent section by applying the roofing cement along the edges, snap together with fixed vent, and fasten to the deck in the same manner as the first section_ Fasten the ridge shingles over the vent to the deck on the marked "shingle nail line" with two (2) minimum 11 ga. 2/z-inch galvanized ring shank roofing nails (shall comply with FBC Section 1506.5) provided with the vent or as directed by the shingle manufacturer's installation instructions. Allowable Roof Coverings: Asphalt shingles OCRI4003.3 FL10758-R7 Page 2 of 5 This evaluation report is provided for State of Fbrida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not ---- PF..--III.. d 4 1 o—i- CREEK�7 C� K OWENS CORNING ROOFING AND ASPHALT LLC VentSure® Roof Ventilation TECHNICAL SERVICES. LLC VentSure' Low Profile 18" x 24" x 2-3I16' (32" x 23" flange base) static off -ridge vent composed of ASTM Slant Back Roof Vent A653 galvanized steel (available with painted finish). Material shall conform with with Exterior Louver: FBC Section 1507.4.3. _...__,.._..— _, .. -.f• W 4� I OCrT Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing construction_ Roof deck shall be designed and installed in accordance with FBC requirements. Roof slope: Minimum 3:12 Installation Height: Maximum 33-ft Attachment Method: Cut an 11 x 11-inch hole through wood sheathing only approximately 18-inches from the ridge. Apply 1/4-inch thick by 3-inch wide bed of ASTM D 4586 roofing cement around inner and outer flange. Place vent directly over the hole, ensuring the vent sits flat on the roof. Fasten vent flinches o.c. and 1-inch from outside edge of flange with minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5), ensuring Y inch penetration through wood deck (Minimum 18 nails per vent). Install baffle in '/.-inch bed of ASTM D 4586 roofing cement and secure with minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5) spaced 8-inches o.c. (total of (3) nails) while ensuring %-inch penetration through wood deck. Seal all nails and vent flange with ASTM D 4586 roofing cement_ Allowable Roof Coverings: Asphalt shingles OCR14003.3 FL1 d758-R7 Paoe 3 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shalt notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not ' ^> CREEK E �h j OWENS CORNING ROORNG AND ASPHALT LLC VentSure@ Roof Ventilation TECHNICAL SERvicEs, LLC VentSure'' Rigid Roil 519" x 11-114' x 20' attic ridge vent composed of high density polypropylene with a Ridge Vent: spun -bond polypropylene fabric. 2# Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing construction. Roof deck shall be designed and installed in accordance with FBC requirements. Roof slope: Minimum 2:12 to maximum 20:12 Installation Height: Maximum 60-ft Attachment Method: Cut a 2-inch opening (1-inch on each side of the ridge) centered in the deck at the ridge for ventilation. The slot shall terminate approximately 12-inches from the rake edges_ Apply a continuous bead of polyurethane adhesive sealant along the entire length of the outside edges of the vent to seal the vent to the field shingles. Center the vent over the opening and fasten the vent 24-inches o.c. to the deck using minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5), ensuring %-inch penetration through wood deck. Fasten the ridge shingles over the vent to the deck on the marked 'shingle nail line" with two (2) minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5) or as directed by the shingle manufacturer's installation instructions, ensuring %-inch penetration through wood deck. Outside edges of the shingles shall be sealed with flashing cement. Allowable Roof Coverings: Asphalt shingles LIMITATioNs 1) Fire Classification is outside the scope of this evaluation. 2) This report is not for use in the HVHZ. 3) The roof deck and deck attachment shall be designed by others in accordance with the FBC. 4) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. 5) Owens Corning vents shall be installed in strict compliance with this evaluation report and the manufacturer's published installation instructions. In the event of conflict, the more restrictive installation shall be enforced. 5) Deck substrates shall be clean, dry, and free from any irregularities and debris_ All fasteners in the deck shall be checked for protrusion prior to installation. 7) Installation of the roof assembly is outside the scope of this evaluation. 8) Owens Corning vents are intended to provide passive ventilation for an enclosed attic in residential construction applications. OCR14003.3 FL10758-R7 Paae 4 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not �..o..IF­II" h-m CREEK TECHNICAL SEFZVICES, LLC COMPLIANCE STATEMENT OWENS CORNING ROOFING AND ASPHALT LLC VentSure® Roof Ventilation The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 6th Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. R. No 74021 STATE OF CERTIFICATION OF INDEPENDENCE 2 017.09.3 0 15:16:17 -041001 Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation_ CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire. a financial interest in any other entity involved in the approval process of the product. END OF REPORT OCRI4003.3 FL10758-R7 Paoe 5 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not .n rF 11M .,4,4 oc 4 Ko in