HomeMy WebLinkAboutPA FL9777-R116Ci5 dome { Log In User Registratlor
Product Approval
db'pr (A USER: Public User
.. ............q ?I 1r
....
.�.
HaLTapics Submit Surcharge StAM & FaCCs PutrllCatior1S Contact Us 13CLS Site Map Links Search
QQyAs;.L.@,ra�ri�, > Product or Aonlicatlon Search > Application List � Application Detail
FL #
FL9777-R11
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
Archived
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo, OH 43659
(740) 404-7829
greg.keeler@owenscorning.com
Authorized Signature Greg Keeler
greg.keelc,r@ovvcnscorning.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
AddressJPhone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Zachary R. Priest
the Evaluation Report
Florida License PE-74021
Quality Assurance Entity JL LLC
Quality Assurance Contract Expiration Date 12/31/2020
Vatidated By Locke Bowden RE.
Val[datien Checklist - Hardcopy Received
Certificate of Independence Fl2Z7_PU C4I OCR 14002.8a 2017 FBC Eva[uAiQn Rep9rt_Weatherlock
N n-H�VHZ f_
Referenced Standard and Year (of Standard) Standard Year
ASTM D 1970 2015
ASTM D 226 2009
ASTM G 155 2005
https./jwww.fIoridabuiIding.org;prlpr-app-dt1,aspx?pararn=wCEVXQwtDgtgkcMGbIcW71%2fZr7gduclvKE1MFgEi3nc[V6018835636Kw%3d%3d Page 1 of 3
TAS 103
UL 1897
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
10/11/2017
Date Validated
10/11/2017
Date Pending FBC Approval
10/17/2017
Date Approved
12/12/2017
Summary of Products
1995
2017
FL # Model, Number or Name
Description
9777.1 Weatherlock G ���
Weatherproofing Underlayment
Limits of Use _
Installation instructions
Approved for use in HVHZ: No
FL9777 R11 11 R 4 2 7 F
Evaluati n Repor
Weathercock Non-HVHZ.p»d
Approved for use outside HVHZ: Yes
Impact Resistant: NJA
Verified By: Zachary R. Priest 74021
Design Pressure: N/A
Created by independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL9777 R11 A ❑ R14 Z. FBC Eva ua'ion r
Weatherlock Nan-HVHZ.gdf
Created by Independent Third Party: Yes
9777.2 WeatherLock G (High Tear)
Weatherproofing Underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL9777_RI 1110L 400.8a_2017 FBC
Evaluation Pe or
Weatherlock Non-HVHZ.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: NIA
Verified By: Zachary R. Priest PE-74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL977? R11 AE OCR14002.8a 2017 FBC
Evaluation Report
We th r n-H
Created by Independent Third Party: Yes
9777.3
Weatherlock MAT
Waterproofing Underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
F1,9777 R11 II OCR14002.86 Z017 FBC
£valuation lii
Approved for use outside HVHZ: Na
Weatherlock HVH7.pdf
Impact Resistant: NIA
Verified By: Zachary R. Priest 74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL2777_R11 AE OCR14002.8b 2017 FBC
Eval atQ-n Repp tr
Weatherlock HVHZ.pdf
Created by Independent Third Party: Yes
9777,4
Weatherlock MAT
Waterproofing Underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
F_L9777 R.11 11 OCR14-17 FBC-.-Evzluatior
Repo
Approved for use outside IiVHZ: Yes
Wcatherlock Nan-HVHZ.pd
Impact Resistant: N/A
Verified By: Zachary R. Priest 74021
Design Pressure: NJA
Created by Independent Th 1 rd Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
EL277_R11 AF OCR14002.8a 2 17 F
E lu 1 n R pod
Weatherlock Non-HVH7,12d
Created by Independent Third Party: Yes
https://www.floridabuilding.org/pripr_app_dtl.aspx2pararr=wGEVXQwtDgtgkcMGbJcW7[%2f7u7gduclvKEIMFg53ndVG01883S636Kw%3d%3ci Page 2 of 3
9777.5
WeatherLock Metal
Weatherproofing Underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL9777 R11 II OCR140 2. 2 7 v luation Re ort
Weatherloek Non-HVHZ.nf ,f
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest PE-74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL9777 R11 &E_9-CR14002,8a 2017 FBC Evaluation Report
Weal hQTioc Nan HVHZ.Ddf
Created by Independent Third Party: Yes
9777.6
WeatherLock Metal
Weatherproofing Underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: No
FL9777. 1111 II OCR14002.8b 2a17 FB F ialuation Dort
Weatherloek HVHZ. ]�df
Impact Resistant: N/A
Verified By: Zachary R. Priest PE-74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL9777 R11_ �E QCR14002,8b 2017 FBC Evaluation Rrl2Q
WpJljgtQck HVHZ.pdf
Created by Independent Third Party: Yes
9777.7
WeatherLock Specialty Tile & Metal
Weatherproofing underfayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL9777 R11 II_OCR14_pQ2.5d 2017 FBC Evaluation Report
Weatherlock Non-HVHZ.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest 74021
Design Pressure: +0/-142.5
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL9777 1111 AE OCR140 2,,8,a2017 FBC Evaluation Report
Weatherlock Non-HVHZ.pd
Created by Independent Third Party: Yes
t3aC1: h19><t
Contact Us :: 2601 Nair Stone Road, D[I&Qssee FL 3d393 Phone: 850-487-1824
The State of Florida is an AA)EEO employer. CoRynuht 2007-2013 State of Florida.:: PrivaCy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-renorde request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail, if you have any questions, please Contact 650.487.1395. "`Pursuant to Section
455.275(1), Florlda statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. most provide the Department with an email address if they have
one. The emails provided may be used for oericial communication wlth the licensee. However email addresses are public record. if you do not wish to supply a
personal address, please provide the Department with an email address which can be made available to the public. To determine if YOU are a licensee under Chapter
455, F.S., please click here .
Product Approval Accepts:
® Wfl R sCikr.
Credit Card
Safe
https_JJwww.floc[dabuilding.org/prlpr_app_dtl.aspx?pararil=wGEVXQwtDgtgkcVGbfcW71%2fZr7gdugvKF1MFg53ndV6018835636Kw%3d%3d Page 3 of 3
Certificate of Authorrzafion No. 29824
CREEK17520 Edinburgh Drive
Tampa, FL 33647
TECHNICAL SERVICES, LLC (813)480-3421
EVALUATION REPORT
FLORIDA BUILDING CODE, 6"H EDITION (2017)
Manufacturer:
OWENS CORNING ROOFING AND ASPHALT LLC Issued October 11, 2017
1 Owens Corning Parkway
Toledo, OH 43657
(800) 438-7465
www.owenscarnin .Com
Manufacturing Location:
Brentwood, NH
Houston, TX
Quality Assurance:
UL LLC (OUA9625)
SCOPE
Category:
Roofing
Subcategory:
Underlayments
Code Sections:
1504.3.1, 1507.1.1
Properties:
Physical properties
REFERENCES
Entity
Report No_
Standard
Year
PRI Construction Materials Technologies (TST5878)
NFI-039-02-01
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
NEI-042-02-01 REV2
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
NEI-045-02-01
TAS 103
1995
PRI Construction Materials Technologies (TST5878)
NEI-045-02-01
ASTM G 155
2005a
PRI Construction Materials Technologies (TST5878)
NEI-053-02-01
TAS 103
1995
PRI Construction Materials Technologies (TST5878)
NEI-053-02-01
ASTM G 155
2005a
PRI Construction Materials Technologies (TST5878)
NEI-093-02-02
ASTM ❑ 1970
2015
PRI Construction Materials Technologies (TST5878)
OCF-213-02-01
ASTM ❑ 1623
2009
PRI Construction Materials Technologies (TST5878)
OCF-237-02-01
UL 1897
2012
PRI Construction Materials Technologies (TST5878)
OGF-252-02-01
ASTM D 4798
2001
PRI Construction Materials Technologies (TST5878)
OGF-252-02-01
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
OCF-253-02-02
ASTM D 1970
2015
PRI Construction Materials Technologies {TST5878}
OCF-272-02-01
TAS 103
1995
PRI Construction Materials Technologies (TST5878)
OCF-296-02-02
fCC-ES AC 188'
2012
ICC-ES AC 48
2012
PRI Construct -ton Materials Technologies (TST5878)
OCF-297-02-01.1
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
OCF-318-02-01
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
OCF-320-02-01
TAS 103
1995
PRI Construction Materials Technologies (TST5878)
OGF-320-02-01
ASTM G 155
2005a
PRI Construction Materials Technologies (TST5878)
OCF-321-02-01
ASTM D 1623
2009
PRI Construction Materials Technologies (TST5878)
OCF-322-02-01
UL 1897
2012
PRI Construction Materials Technologies (TST5878)
OCF-355-02-01
UL 1897
2012
'Determined to be equivalent to ASTM D 226-09, Type I
and II
OCR14002.8a FL9777-R11 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or qualify assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
,. CREEK
TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION AND LimlTS OF USE
OWENS CORNING ROOFING AND ASPHALT LLC
Weatheril Self -Sealing Ice & Water Barriers
WeatherLock(9 G
WeatherLock® G is an ASTM D 1970 self-adhesive underlayment constructed from SBS
(Brentwood, NH)
modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The
product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.7-ft.
WeatherLockg G is permitted to be used as prescribed in FBC Section 1507.1.1 for
mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a
maximum 30 days.
WeatherLock® Mat
WeatherLock® Mat is an ASTM D 1970 self-adhesive underlayment constructed from
(Brentwood. NH or
SBS modified asphalt with a fiberglass mat reinforcement. The product is supplied in 1-
Houston, TX)
sq. rolls with nominal dimensions of 3-ft x 33.3-ft and 2 sq. rolls with nominal dimensions
of 3-ft x 66.7-ft.
WeatherLock® Mat is permitted to be used as prescribed in FBC Section 1507.1.1 for
mechanically attached roof coverings. Exposure on the roof deck shall be limited to a
maximum W days.
WeatherLock® Metal
WeatherLockG) Metal is an ASTM D 1970 self-adhesive underlayment constructed from
(Brentwood, NH)
SBS modified asphalt with a fiberglass mat reinforcement and plastic film surface. The
product is supplied in 2.0 sq. rolls with nominal dimensions of 3-ft x 66.7-ft.
WeatherLock® Metal is permitted to be used as prescribed in FBC Section 1507.1 .1 for
mechanically attached roof coverings_ Exposure on the roof deck shall be limited to a
maximum 90 days.
WeatherLock®
WeatherLock® Specialty Tile & Metal is an ASTM D 1970 self-adhesive underlayment
Specialty Tile & Metal
constructed from SBS modified asphalt and surfaced with a non -woven polyester fabric.
(Brentwood, NH or
The product is supplied in 2.14 sq. rolls with nominal dimensions of 3-ft x 71.3-ft.
Houston, TX)
WeatherLock® Specialty Tile & Metal is permitted to be used as prescribed in FBC
Section 1507.1.1. WeatherLock® Specialty Tile & Metal is permitted to be used with
adhered clay or concrete tile roofing using either ICP Adhesives Po€yset AH-160 (ICP
Adhesives and Sealants, Inc.) or TILE BONDTM Roof Tile Adhesive (The Dow Chemical
Company)_ Exposure or the roof deck shall be limited to a maximum 90 days.
The maximum roof slope shall be 6:12 when used with clay or concrete tile installations
without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles
shall not be stacked greater 10 tiles per stack.
WeatherLock0 G (High
WeatherLock® G (High Tear) is a self -adhered, underlayment used as an alternative to
Tear)
ASTM D 226, Type I or Type I I roofing felt and ASTM D 1970 self -adhering polymer
(Houston; TX)
modified bitumen underlayment. The underlayment is composed of SBS modified
asphalt with a fiberglass mat internal reinforcement and is surfaced with granules. The
product is supplied with a nominal thickness of 50 mils in 1.95-sq rolls with nominal
dimensions of 3-fl x 65-ft.
WeatherLock® G (High Tear) is permitted to be used as prescribed in FBC Section
1507.1.1 for mechanically attached roof coverings_ Exposure on the roof deck shall be
limited to a maximum 30 days.
0CR14002.8a FLU777-R11 Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
c noniFinnlhr n.1.-�rectreri iorcain
CREEK^Y,'S
TECHNICAL SERVICEs, LLC
PRODUCT APPLICATION
OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLock,& Self -Sealing Ice & Water Barriers
Min. Roof Slope: 2:12 in accordance with the FBC
Application_ All underlayments shall be installed in accordance with the FBC.
Deck substrates shall be clean, dry, and free from any irregularities and debris. All
fasteners in the deck shall be checked for protrusion and corrected prior to underlayment
application. Prior to beginning installation, the underlayment shall be unrolled and
allowed to relax for a minimum of 3-5 minutes.
The underlayment shall be installed with the release backer removed and pressed firmly
into place to ensure complete contact with the deck. The underlayment shall be installed
with the roll length parallel to the eave, starting at the eave, and with minimum 3" side
laps and minimum S" end laps staggered min. 6-ft.from preceding course. Additionally, if
applying WeatherLock® Specialty Tile & Metal, end laps shall be primed with ASTM D
41 primer or sealed with asphalt roof cement a minimum of 3-4 inches across the width
of the lap_
It is permissible to back nail the underlayment 12-inches on -center as needed (nails shall
be installed perpendicular to deck with the nail heads flush to the top surface of the
underlayment). Additionally, WeatherLockOR Specialty Tile & Metal shall be back nailed
when installed on roof slopes greater than 3:12.
Min. Application 44'F; Contact the manufacturer when installing at temperatures below the minimum
Temperature: application temperature.
WIND RESISTANCE
The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9.
Underla meni System hto.1 — WeatherLock Specialty Tile & Metal Only
Roof Deck: Min. 15132-inch CDX plywood attached to wood supports spaced a maximum 24" o.c.
Underlayment: WeatherLockb Specialty Tile & Metal shall be applied in accordance with
manufacturer's installation instructions to the fastened deck and backnailed along the
selvage with minimum 12ga., 1-1/4-inch galvanized ring shank roofing nails through
optionally primed, 32ga. x 1-5/8-inch 0 tin caps spaced 12" o_c The applied
underlayment shall be rolled with a minimum 751b steel roller immediately following
application.
Maximum Design -142.5 psf
Pressure:
OCR14002.8a FL9777-Ri 1 Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify GRFEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, reeammended use, or other product attributes that are not
r ` CREED
TECHNICAL SERVICE5. LLC
GENERAL LIMITATIONS
OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLocM Self -Sealing Ice & Water Barriers
1) This evaluation report is not use in the HVHZ.
2) Fire Classification is not within the scope of this evaluation.
3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published
application instructions- Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction.
5) The space under the deck area shall be properly ventilated in accordance with the FBC requirements.
6) All side lap seams shall be installed to shed water from the deck.
7) The underlayment may be used as described in other current FBC product approval documents.
8) Design wind load pressures shall be determined for components and cladding in accordance with FBC
1609.
9) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind
load pressures for components and cladding.
10) Maximum Design Pressures for a given underlayment shall meet or exceed the design wind loads
determined for the roof assembly.
11) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code 61h Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
1�j11Ill���
R.
IV
No 74021
:J�
�:. STATE OF : kr� •
A
S
,elf5
CERTIFICATION OF INDEPENDENCE
2017.10.11
� f 09:06:29
-04r001
Zachary R_ Priest, P.E.
Florida Registration No. 74021
Organization No. AN E9641
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products underthis evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
OCR14002.8a FL9777-R11 Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule fit G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evafuation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not