Mini split information for review
Project Summary Date: +� wrightsoft' Entire House By. QUICK CALCS, INC. 317 ST. LUCIE LANE, Fr. PIERCE, FIL 34946 Prom: 772-46&6799 Erroll: QUICKCALCS@AOL.COM .1 "Project Information'' For: EDWARDWEST 7905 LINKS WAY, ST. LUCIE WEST, FL34986 Notes: Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF DesignTD 28 OF DesignTD 15 OF Daily range M Relative humidity 50 Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 8990 Btuh Structure 10458 Btuh Ducts 1695 Btuh Ducts 2400 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 10685 Btuh Use manufacture's data n Rate/swingq multiplier 0,95 Infiltration Equipmentsenslbleload 12215 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1811 Btuh Ducts 620 Btuh Central vent (0 cfin) 0 Btuh Heatingg Coolingg (none) Area (ft) 504 504 Equipment latent load 2431 Btuh Volume (ft) 4536 4536 Airchanges/hour 0,61 0,32 Equipment Total Load (Sen+Lat) 14646 Btuh Equiv. AVF (cfm) 46 24 Req. total capacity at 0.70 SHR 1.5 ton Heating Equipment Summary Cooling Equipment Summary Make Daikin Make Daikin Trade Trade Model RXB18AXVJU Cond RXB18AXVJU AHRI ref 10574896 Coil FTXB18AXVJU AHRI ref 10574896 Efficiency 9 HSPF Efficiency 17.0 EER,17 SEER Heafing input Sensible cooling 12600 Btuh Heating output 17000 Bluth @470F Latentcooling 5400 Btuh Temperature rise 27 OF Total cooling 18000 Btuh Actual airflow 567 cfm Actual airflow 567 cfm Airflowfactor 0.053 cfm/Btuh Airflowfactor 0,044 cfrn/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.84 Capacity balance point = 31 OF Backup: Input= 3 kW, Output=10312 Bluth, 100 AFUE Calculations approved byACCAto meet all requirements of Manual J Sth Ed wright_softa 2026Sep-1414:27:36 ��-- Rigk-SuleO Wtiversa1201919.0.07 RSU08101 page 1 IR..VI'1 ...UICK\Donnteris\Wngllmg HVAC\WEST, EDWARD.rW Coo =MJB Frort Door faros: E +� wrightsort° RighW@ Worksheet Date: Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Phow: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name Entire House GARAGE 2 Exposed Nell 69.0 It 69.0 It 3 Room height 9.0 It 9.0 ft heat/cool 4 Room dimenuons 21.0 x 24.0 It 5 Room area 504.0 ft' SO4.0 n' Ty ConstivrL'on U-value Or HTM Area (fF) Load Area (ff) Load number (Btuhlt'°F) (Blulvd0 or perimeter (ft) (Stub) or perimeter (fi) (BWh) Heat I Cool Grass NIPS Heat Cool Gros NPS Heat Cool 6 W 13AAc s 0.143 In 4.00 2.19 216 104 416 228 216 104 416 228 L—D 11J0 0.600 n 16.80 16,90 112 112 1882 1781 112 112 1882 1781 W 13A-4ocs 0.143 a 4.00 2.19 189 169 677 370 189 169 677 370 1A- tom 1.270 e 35.56 87.06 20 1 711 1741 20 1 711 1741 11 W 13AAcos 0.143 s 4A0 2.19 216 216 865 473 216 216 865 473 12"w 0,091 - 2.55 0.00 189 168 428 0 189 168 428 0 L--D 11D0 0,390 n 10.92 10.34 21 21 229 217 21 21 229 217 C 166-30ad 0.032 '0.90 1.60 504 504 ':452 806 504 504 452 806 F 22A-tpl 0.989 - 27.69 0.00 504 69 1911 0 504 69 1911 0 6 0) AED ex urdon 124 124 EnvelopeloWgain 7570 5739 7570 5739 12 a) Infiltration 1419 399 1419 399 b) Roorawnfilation 0 0 0 0 13 Internal gains Oovpanls@ 230 4 920 4 920 Appliances/other 3400 3400 Subtotal(lines6 to 13) 8990 10458 8990 10458 Less external load 0 0 0 0 Lestransfer 0 0 6 0 Redistribution 0 0 0 0 14 Subtotal 8990 10458 8990 10458 15 Ductloads 19% 230% 1695 2400 19% 23% 1695 2400 Total room load 10685 12858 1065857 12858 Air required (urinal 567 567 567 567 Calculations approved bvACCA to meet all requirements of Manual. J Sth Ed -r{+- w�osncsor:� zezo-sep-1414z7as ^"""'"'^'"""""-'^^""" RI91d-Sute®Urversa12019790.07 RSU08101 �A...UICK\DoamerislWrigYdsotti-NAC\WEST,EDWAR0.np CaIc=MJe Fror*Door faces E Pagei FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method ProjectName: EDWARD WEST BuilderName: Street: 7905 LINKS WAY Permit Office: City, State, Zip: ST. LUCIE WEST, FL, PermitNumber: Owner: EDWARD WEST Jurisdiction: DesignLocation: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2) 1. New construction or existing New (From Plans) 9. Wall Types (552.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block- Ext lnsul, Exterior R=0.0 552.00 112 b. N/A R= ft2 3. Number of units, if multiple family 1 G. N/A R= ft2 4. Numberof Bedrooms 0 d.N/A R= ft2 10. Ceiling Types (504.0 sgft.) Insulation Area 5. Is this a worst case? No a. UnderAttic (Vented) R=19.0 504,00 ft2 6. Conditioned floorarea above grade(ft') 504 b. N/A R= ft2 c. N/A R=, ft2 Conditioned floor area below grade(ft2) 0 11, Ducts R ft2 7. Windows(20.0 sgft.) Description Area a. U-Factor: SgI, U=0.65 20.00 112 SHGC: SHGC=0,30 b. U-Factor: N/A fP 12. Cooling systems kBtu/hr Efficiency a. Central Unit 18.0 SEER:17.00 SHGC: c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtuihr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 18.0 HSPF:9.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC; 0,300 14. Hot water systems a. 8. Floor Types (504.0 sgft.) Insulation Area EF:9.6369E036 a.Slab-On-Grade Edge Insulation R=0.0 504.00 112 b. Conservation features b. N/A R= ft2 c. N/A R= n2 15. Credits Pstat Total Proposed Modified Loads: 20.76 PASS Glass/Floor Area: 0.040 Total Baseline Loads: 21.71 F9J I hereby certify that the plans and specifications covered by Review of the plans and QT$ srgT6 this calculation are in compliance with the Florida Energy specifications covered by this � ©,� Code. calculation indicates compliance q arn' with the Florida Energy Code. PREPARED 1: Before construction is completed b DATE: 9-14-202 this building well be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. 64 Wla with the Florida Energy Code. C�b� OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5,00 ACH50 (R402.4.1.2). 9f14/20202:19 PM EnergyGaugeOO USA6.0,02 (Rev.1)-FlaRes2017 FBC 6th Edition (2017)Complianl Software Pagelof4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: EDWARD WEST Bedrooms: 0 Address Type: Street Address Building Type: User ConditionedArea: 504 Lot# Owner Name: EDWARD WEST Total Stories: 1 Block/Subdivision: #of Units: i Worst Case: No PlatBook: BuilderName: RotateAngle: 0 Street: 7905 LINKS WAY PermitOffice: CrossVenlilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: ST. LUCIE WEST, FamilyType: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design DailyTemp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_ VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 504 4032 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfI ID Finished Cooled Heated 1 GAR 504 4032 No 0 1 Yes Yes Yes FLOORS # FloorType Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulation GAR 69It 0 504 ft' 0 1 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Flatfile/slate 531 ft' 0 ft' Light N 0.6 No 0.7 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 504 ff' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) GAR 19 Blown 504W 0.1 Wood 9114/20202:19 PM 'EnergyGauge®USA6.0.02 (Rev.1)-FlaRes2017 FBC6th Edition (2017)Complianl Software Pagetof4 FQRNA R4n.-gn17 INPUT SUMMARY CHECKLIST REPORT Ornt DoorType Height In Ft In WINDOWSFt Orientation Wall • , Ornt ID Depth 0.65 0.3 N 20.0 W 2 It i in I It 4 in None None INFILTRATION Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Single HSPF:9 18 kBtuihr 1 Ductless COOLINGSysternType :. FSEC Collector Storage Carl CompanyName System Model# CollectorModel# Area Volume FEF 9/14/20202:19 PM EnergyGauge®USA G.0.02 (Rev.1)-FlaRes2017 FBC 6th Edition (2017)Compliant Software Page3of4 9/14l20202:19 PM EnergyGauge®USA6.0.02 (Rev.1)-FlaRes2017 FBC6th Edition (2017)Complianl5oftware Page4of4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 2. Single-family or multiple -family 2. Single-family b) Return ducts R c) AHU location 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 0 13. Cooling system: Capacity 18.0 a) Split system SEER 17.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 504 d) Room uniUPTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.650 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.300 c) Area 7c. 20.0 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 14. Heating system: Capacity 18.0 a) Split system heat pump HSPF 9.0 b) Single package heat pump HSPF c) Electric resistance COP d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 9a. 0.0 9b. 15. Water heating system 9c. a) Electric resistance EF b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF 10A1. e) Dedicated heat pump with tank EF 10A2. 0.0 f) Heat recovery unit HeatRec g) Other 10B1. 10B2. 16. HVAC credits claimed (Performance Method) a) Ceiling fans 11a. 19.0 b) Cross ventilation No 11b. c) Whole house fan No C. d) Multizone cooling credit 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. BuilderSignatu Address of New Home: 7905 LINKS WAY City/FL Zip: ST. LUCIE WEST. FL 9/14I20202:24:42 PM EnergyGauge®USA 6.0.04 (Rev.1)-FlaRes2017 FBC 6th Edition (2017)Corn pliant Software Pagel oft 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: EDWARD WEST Builder Name: Street: 7905 LINKS WAY Permit Office: City, State, Zip: ST. LUCIE WEST, FL , Permit Number: Y Owner: EDWARD WEST Jurisdiction: w Design Location: FL, Fort Pierce x� COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealingmaterial. Breaks orjoinls in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed, with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spas Ns. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids bQ&Q�o fiM apda�IQE cover plates and walls or ne i0ati _U _.... _....._.,645 ..... r...,,..,P I ... I..y ...,.PIJ .,, I.,I I .,., ,,, awo,UanUo vvmi uic pi wisious w wi.-vuu. 9/14/2020 2:19 PM EnergyGauge© USA 6.0.02 (Rev. 1) - FlaRes2017 FBC fith Edition (2017) Compliant Software Page 1 of 1