HomeMy WebLinkAboutSign informationINDIVIDUAL INTERNALLY LED ILLU MINATED CHANNEL LETTERS ON RACEWAY
15.75 S.F.
ALLOWABLE SIGN AREA
25' X 13' = 325 S.F. X 20% = 65 S.F.
SIGN = 18" X 126" = 15.75 S.F.
25' STOREFRONT
JOB TITLE erw m W addle ADDRESS 1`31. 0APPROVED a' 4444 S.E. COMMENCE AVE. Thls=lg wd 11nptkepea
i en the exdu�be prop�rb oT R�mingo
NOTE: ALL ARTWORK &COLORS MUST BE SIGNED OFF BEFORE ANY WORK IS TO BEGIN APPROVED W/CHANGES STUART, PL. 34997 81pne AM mg not beeh.wntoayp.non
IF EXACT COLORS ARE REQUIRED OR MORE DETAILS PLEASE NOTE. CUSTOMER IS O NOT APPROVED 772.22o.77sf1 or
ra theeyy to be.ketI mp�y.shap.
RESPONSIBLE FOR ANY CHANGES ONCE WORK BEGINS. RESUBMIT W/ CHANGES
fiamingosigns@aol.com o° r rain withouttthreproduced sed�w:.no meM
I- or
(ND1V[DUAL INTE(Z NaLLY LED ILLUMINATED CHANNEL LETTER5.0N (RACEWAY
Letters to be fabricated of .063 aluminum backs
with .040 black returns. Interior of letters to be
gloss white.
Faces to be 3/16" 7328 white acrylic with 1"
black Gemini 2025 trimcaps.
Lighting to be bright white Hanley led modules
attached with 3M VHB tape. Power supples to be
Hanley 120 / 12 v. 1.1a premium power supplies.
Letters mounted to EMS aluminum extruded
raceway minimum 4 per letter #8 tech screws.
Raceway fabricated of .125 aluminum to meet
UL standards. Backs have inset track to accept
2" mounting clips. Clips to be spaced no more
than 48" max. 1 top & 1 bottom with minimum 2
pair per raceway. 3 TOTAL
Raceway painted to match wall section.
UL Rated disconnect mounted to end of raceway
Primary electrical feed in UL conduit connected to
existing power supply to be provided.
Wall section: Concrete Block
Sign mounted to wall section with 3/8" hardware
to be determined by wall type with minumum 2"
embedment. expansion anchors
(1) 20 amp 120V Circuit Req.
This sign is to be installed in accordance with
the requirements of Article 600 of the National
Electrical Code.
1) Grounded and bonded per NEC 600.7/NEC 250
2) Existing branch circuit in compliance with
NEC 600.5, not to exceed 20 amps
3) Sign is to be UL listed per NEC 600.3
4) UL disconnect switch per NEC 600.6- required per
sign component before leaving manufacturer*
*For multiple signs, a disconnect is permitted but
not required for each section
U` LISTED
\`I jell
UL TO2014NECN(N.TF/�A�lm 1600.3`ING
ULTIMATE WIND VELOCITY = 170 MPH
R15K CATEGORY it EXP05UKE "C"
6th EDITION "2017 FBC"
JOB TITLE SALON VIVACIOUS ADDRESS PORT 5T LUCIE
PO
4444 S.E. COMMERCE "I-
JAME5 E. FAIT, P.E. REG#25497
NOTE: ALL ARTWORK & COLOR5 MUST BE 51GNED OFF BEFORE ANY WORK IS TO BEGIN
fL
5TUART, FL. 34997
1963 5E PALM CITY RD 5TUART FL 34994
IF EXACT COLORS ARE REQUIRED OR MORE DETAILS PLEASE NOTE. CUSTOMER L5
7722207377
FAX 772 22 0 7768
PHONE 263-2677
RE5PON516LE FOR ANY CHANGES ONCE WORK BEGINS.