HomeMy WebLinkAboutSign informationINDIVIDUAL INTERNALLY LED ILLU MINATED CHANNEL LETTERS ON RACEWAY 15.75 S.F. ALLOWABLE SIGN AREA 25' X 13' = 325 S.F. X 20% = 65 S.F. SIGN = 18" X 126" = 15.75 S.F. 25' STOREFRONT JOB TITLE erw m W addle ADDRESS 1`31. 0APPROVED a' 4444 S.E. COMMENCE AVE. Thls=lg wd 11nptkepea i en the exdu�be prop�rb oT R�mingo NOTE: ALL ARTWORK &COLORS MUST BE SIGNED OFF BEFORE ANY WORK IS TO BEGIN APPROVED W/CHANGES STUART, PL. 34997 81pne AM mg not beeh.wntoayp.non IF EXACT COLORS ARE REQUIRED OR MORE DETAILS PLEASE NOTE. CUSTOMER IS O NOT APPROVED 772.22o.77sf1 or ra theeyy to be.ketI mp�y.shap. RESPONSIBLE FOR ANY CHANGES ONCE WORK BEGINS. RESUBMIT W/ CHANGES fiamingosigns@aol.com o° r rain withouttthreproduced sed�w:.no meM I- or (ND1V[DUAL INTE(Z NaLLY LED ILLUMINATED CHANNEL LETTER5.0N (RACEWAY Letters to be fabricated of .063 aluminum backs with .040 black returns. Interior of letters to be gloss white. Faces to be 3/16" 7328 white acrylic with 1" black Gemini 2025 trimcaps. Lighting to be bright white Hanley led modules attached with 3M VHB tape. Power supples to be Hanley 120 / 12 v. 1.1a premium power supplies. Letters mounted to EMS aluminum extruded raceway minimum 4 per letter #8 tech screws. Raceway fabricated of .125 aluminum to meet UL standards. Backs have inset track to accept 2" mounting clips. Clips to be spaced no more than 48" max. 1 top & 1 bottom with minimum 2 pair per raceway. 3 TOTAL Raceway painted to match wall section. UL Rated disconnect mounted to end of raceway Primary electrical feed in UL conduit connected to existing power supply to be provided. Wall section: Concrete Block Sign mounted to wall section with 3/8" hardware to be determined by wall type with minumum 2" embedment. expansion anchors (1) 20 amp 120V Circuit Req. This sign is to be installed in accordance with the requirements of Article 600 of the National Electrical Code. 1) Grounded and bonded per NEC 600.7/NEC 250 2) Existing branch circuit in compliance with NEC 600.5, not to exceed 20 amps 3) Sign is to be UL listed per NEC 600.3 4) UL disconnect switch per NEC 600.6- required per sign component before leaving manufacturer* *For multiple signs, a disconnect is permitted but not required for each section U` LISTED \`I jell UL TO2014NECN(N.TF/�A�lm 1600.3`ING ULTIMATE WIND VELOCITY = 170 MPH R15K CATEGORY it EXP05UKE "C" 6th EDITION "2017 FBC" JOB TITLE SALON VIVACIOUS ADDRESS PORT 5T LUCIE PO 4444 S.E. COMMERCE "I- JAME5 E. FAIT, P.E. REG#25497 NOTE: ALL ARTWORK & COLOR5 MUST BE 51GNED OFF BEFORE ANY WORK IS TO BEGIN fL 5TUART, FL. 34997 1963 5E PALM CITY RD 5TUART FL 34994 IF EXACT COLORS ARE REQUIRED OR MORE DETAILS PLEASE NOTE. CUSTOMER L5 7722207377 FAX 772 22 0 7768 PHONE 263-2677 RE5PON516LE FOR ANY CHANGES ONCE WORK BEGINS.