Loading...
HomeMy WebLinkAboutDesign Certification for Wind Load ComplianceI ST. LUCIE COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT • - 2300 VIRGINIA AVENUE, ROOM 201 .<` FT. PIERCE, FL. 34982-5652 407-462-1553 DESIGN CERTIFICATION FOR WIND LOAD COMPLIANCE This Certification is to be completed by the project design architect or engineer. This Certification must be submitted with all applications for building permit involving the construction of new residence (single or multi -family), residential addition, any accessory structure requiring a building permit, and any nonresidential structure. This Certification shall not apply to interior renovations (provided that no structural walls, columns or other similar component is being effected) and certain other minor building permits... For further assistance, please contact the Building: Inspection Office at 462-1553 or 462-2172. ` CERTIFICATION STATEMENT: 1 CERTIFY THAT, :TO THE BEST OF MY KNOWLEDGE AND BELIEF, THESE PLANS AND SPECIFICATIONS HAVE BEEN DESIGNED TO COMPLY WITH THE APPLICABLE STRUCTURAL PORTION OF THE BUILDING CODES CURRENTLY ADOPTED AND ENFORCED. BY ST. LUCIE `COUNTY. I ALSO CERTIFY THAT STRUCTURAL ELEMENTS DEPICTED .ON THESE PLANS PROVIDE ADEQUATE RESISTANCE TO. THE WIND LOADS AND FORCES SPECIFIED BY CURRENT CODE PROVISIONS. DESIGN PARAMETERS AND ASSUMPTIONS USED: (please check,or complete the appropriate box) 1. BUILDING CODE EDITION USED- (YEAR) 19 9 7 SBCCI ASCE 7-88 OTHER (SPECIFY) 2. BUILDING DESIGN IS (CHECK ONE) ENCLOSED X PARTIALLY ENCLOSED OPEN BUILDING 3. BUILDING HEIGHT: 1 7 FT 4.. WIND SPEED USED IN BUILDING DESIGN: 10 0 MPH 5. WIND EXPOSURE CLASSIFICATION (REFER TO EXPOSURE TABLES IN BUILDING CODE IDENTIFIED IN LINE 01): N/A .6. AVERAGE WIND VELOCITY PRESSURE ON EXTERIOR FACES OF STRUCTURE: 31.3. PSF 7. PEAK WIND VELOCITY PRESSURE ON EXTERIOR FACES OF STRUCTURE: 3 S PSF 8. IMPORTANCE/USE FACTOR (OBTAIN FROM BUILDING CODE): 1 .0 9. LOADS: FLOOR 100 PSF ROOFIDt AD: 8 PSF ROOFA.IVE: 20 PSF 10. WERE SHEAR WALLS CONSIDERED FOR STRUCTURE (CHECK Off YES NO X If NO, why? (attach explanation) Moment:,.ri.gsd frames & diagonal bracing .provided in metal building. 11. IS A CONTINUOUS LOAD PATH PROVIDED (CHECK ONE) YES X NO If NO, why? (attach explanation) jr 12. ARE COMPONENT AND CLADDING DETAILS PROVIDED (CHECK oNE) YES X NO If NO, why? (attach explanation) 13. MINIMUM SOIL BEARING PRESSURE: 2000 PSF AS WITNESSED BY MY SEAL, I HEREBY. CERTIFY THAT THE INFORMATION INCLUDED WITH THIS CERTFFVTIO I RUE D C RECT, TO THE BEST OF MY KNOWLEDGE AND BELIEF: NAME: CERTIFICATION NO: 47520 lichael Lue [SEAL HERE] DESIGN FIRM: Mosby & Assoc. , Inc DATE: 6/1.7/98 CDO2a o0