HomeMy WebLinkAboutKING REVISED ENERGY CALCS 9.15.2020FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: KING
Builder Name.
Street: 217 SCHOONER LANE
Permit Office:
City, State, Zip'. DUCK KEY. FL,
Permit Number.
Owner.
Jurisdiction:
Design Location FL, Key West
County. Monroe (Florida Climate Zone 1 )
1. New construction or existing New (From Plans)
9 Wall Types (1580.0 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1580.00 ft2
b.N/A
R= ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
10. Ceiling Types (1548.0 soft.)
Insulation Area
5. Is this a worst case? No
a. Roof Deck (Unvented)
R=30.0 1548.00 ft2
6. Conditioned floor area above grade (ft2) 1548
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11-Ducts
R ft2
7. Windowe(220.0 sgft.) Description Area
a. Sup: Attic. Ret: Attic, AH. ZONE 1
6 309.6
a. U-Factor. S91, U=1.07 220,00 ft2
SHGC: SHGC=0.25
b. U-Factor N/A ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
36.0 SEER:18.00
c. U-Factor. N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Facto[ N/A ft2
a- Electnc Heat Pump
25.0 HSPF:9.60
SHGC:
Area Weighted Average Overhang Depth. 3.036 ft.
Area Weighted Average SHGC. 0.250
14. Hot water systems
a. Electric
Cap: 50 gallons
8 Floor Types (1548.0 soft.) Insulation Area
EF-. 0.970
a. Raised Floor R=19.0 1548,00 ft2
.
bConservation features
b. N/A R= W
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.142 Total Proposed Modified Loads: 60.27
PASS
Total Baseline Loads. 90.23
I hereby certify that the plans and specifications covere by
this calculation are in compliance with the Florida Ene
Review of the plans and
specifications covered by this
0 1Hr SrgT�
1 -_
Code -
calculation indicates compliance
`ao
with the Florida Energy Code.
•. - - -... O
PREPARED BY: l Cc
Before construction is completed
DATE. IS s��f'_p'ZOj_'o
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code
C��O tvCT�O
OWNER/AGENT:
BUILDING OFFICIAL: -_
DATE
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 4.65 ACH50 (R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house.
9/15/2020 1 04 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX' = 67
The lower the Energy Performance Index,
the more efficient the home.
1 New home or, addition
1. New (From Plans)
12. Ducts, location R insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location ZONE
1
3. No. of units (if multiple -family)
3. 1
4. Number of bedrooms
4. 3
13. Cooling system: Capacity
36.0
a) Split system SEER
5. Is this a worst case? (yes/no)
5. No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6. 1548
d) Room unit/PTAC EER
e) Other
18.0
7. Windows, type and area
a) U-factor:(weighted average)
7a. 1.070
b) Solar Heat Gain Coefficient (SHGC)
7b. 0.250
14. Heating system: Capacity
25.0
c) Area
7c. 220.0
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a- NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b. NA
e) Gas furnace, LPG AFUE
f) Other
9.60
9, Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
b) Wood, raised (R-value)
9b. 19.0
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.97
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with lank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF_
2. Masonry (Insulation R-value)
10A2. 4.1
0 Heat recovery unit HealRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
1081.
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a. 30.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11 d. No
e) Multizone heating credit
f) Programmable thermostat
Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise. a new EPL
display card will be completed based on installed code compliant features.
Builder Signature.
Date:
Address of New Home: 217 SCHOONER LANE City/FL Zip: DUCK KEY FL
9/15/2020 1-.04.32 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
• : � : • � � . � ail d�17/7_�:i'��l.Ix�:A6'�r:7� 1�]a1
HOT WATER SYSTEM
V # System Type
SubType
Location
EF
Cap
Use
SetPnt
Conservation
1 Electric
None
ZONE 1
0.97
50 gal
60 gal
120 deg
None
SOLAR HOT WATER SYSTEM
V FSEC
Collector
Storage
Cert #
Company Name
System
Model # Collector Model
# Area
Volume
FEF
None
None
ft2
DUCTS
—Supply—
—Return—
Air
CFM 25
CFM25
HVAC#
V # Location R-Value Area
Location
At"
Leakage Type
Handler
TOT
OUT ON
RLF
Heat Cool
1
Attic
6 309.6 It
Attic
77.4 W
Prop. Leak Free
ZONE 1
— ctInn
46.4 elm 0.03
0.50
1 1
TEMPERATURES
ProgramableHeat)(Coollng')Thermostat:
Ceiling Fans.
]]Y Feb[�(]]
Ir
�Xi
[[ ]] A�gl[X
Oct ([X
Nov
((%l] Dee
Venting [ ] Jan
[ ] Feb
MarpC] Mar
Apr
May
[Xj Jun Jul
[x] Aug
[ Sep
[XjNo
[ J Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5 6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78 78
78
78
80
80
80
80
PM
80
80
80
80
78 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78 78
78
78
80
80
80
80
PM
80
80
80
80
78 78
78
78
78
78
78
78
Heating (WD)
AM
65
65
65
65
65 65
65
68
68
68
68
68
PM
68
68
68
68
68 68
68
68
68
68
68
68
Heating (WEH)
AM
65
65
65
65
65 65
65
68
68
68
68
68
PM
68
68
68
68
68 68
68
68
68
68
68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Detou 8 IWSQ.fL
0 ft°
0 it
0.3
ZONE 1
9/15/2020 1 04 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4