HomeMy WebLinkAboutKING REVISED ENERGY CALCS 9.15.2020FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: KING Builder Name. Street: 217 SCHOONER LANE Permit Office: City, State, Zip'. DUCK KEY. FL, Permit Number. Owner. Jurisdiction: Design Location FL, Key West County. Monroe (Florida Climate Zone 1 ) 1. New construction or existing New (From Plans) 9 Wall Types (1580.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1580.00 ft2 b.N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (1548.0 soft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=30.0 1548.00 ft2 6. Conditioned floor area above grade (ft2) 1548 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11-Ducts R ft2 7. Windowe(220.0 sgft.) Description Area a. Sup: Attic. Ret: Attic, AH. ZONE 1 6 309.6 a. U-Factor. S91, U=1.07 220,00 ft2 SHGC: SHGC=0.25 b. U-Factor N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 36.0 SEER:18.00 c. U-Factor. N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Facto[ N/A ft2 a- Electnc Heat Pump 25.0 HSPF:9.60 SHGC: Area Weighted Average Overhang Depth. 3.036 ft. Area Weighted Average SHGC. 0.250 14. Hot water systems a. Electric Cap: 50 gallons 8 Floor Types (1548.0 soft.) Insulation Area EF-. 0.970 a. Raised Floor R=19.0 1548,00 ft2 . bConservation features b. N/A R= W None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.142 Total Proposed Modified Loads: 60.27 PASS Total Baseline Loads. 90.23 I hereby certify that the plans and specifications covere by this calculation are in compliance with the Florida Ene Review of the plans and specifications covered by this 0 1Hr SrgT� 1 -_ Code - calculation indicates compliance `ao with the Florida Energy Code. •. - - -... O PREPARED BY: l Cc Before construction is completed DATE. IS s��f'_p'ZOj_'o this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code C��O tvCT�O OWNER/AGENT: BUILDING OFFICIAL: -_ DATE DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 4.65 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. 9/15/2020 1 04 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX' = 67 The lower the Energy Performance Index, the more efficient the home. 1 New home or, addition 1. New (From Plans) 12. Ducts, location R insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location ZONE 1 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 36.0 a) Split system SEER 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1548 d) Room unit/PTAC EER e) Other 18.0 7. Windows, type and area a) U-factor:(weighted average) 7a. 1.070 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 14. Heating system: Capacity 25.0 c) Area 7c. 220.0 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a- NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9.60 9, Floor type, insulation level: a) Slab -on -grade (R-value) 9a. b) Wood, raised (R-value) 9b. 19.0 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.97 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with lank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.1 0 Heat recovery unit HealRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 1081. 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise. a new EPL display card will be completed based on installed code compliant features. Builder Signature. Date: Address of New Home: 217 SCHOONER LANE City/FL Zip: DUCK KEY FL 9/15/2020 1-.04.32 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 • : � : • � � . � ail d�17/7_�:i'��l.Ix�:A6'�r:7� 1�]a1 HOT WATER SYSTEM V # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None ZONE 1 0.97 50 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM V FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location At" Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 309.6 It Attic 77.4 W Prop. Leak Free ZONE 1 — ctInn 46.4 elm 0.03 0.50 1 1 TEMPERATURES ProgramableHeat)(Coollng')Thermostat: Ceiling Fans. ]]Y Feb[�(]] Ir �Xi [[ ]] A�gl[X Oct ([X Nov ((%l] Dee Venting [ ] Jan [ ] Feb MarpC] Mar Apr May [Xj Jun Jul [x] Aug [ Sep [XjNo [ J Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Detou 8 IWSQ.fL 0 ft° 0 it 0.3 ZONE 1 9/15/2020 1 04 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4