Loading...
HomeMy WebLinkAboutWind load, architect Advanced Architecture & Planning LLC Architect & Planning 4929 S. Indian River Drive Ft. Pierce, FL 34982 (772)631-5709 Applied Wind Pressures Certification: September 15, 2020 Bill Laprade Glass Professionals, Stuart, Florida Cell: 772-745-3459 Project: Goldman Residence 9900 S. Ocean Dr #1107 Jensen Beach, FL 34957 Dear Mr. Laprade: For the above address, the (3) replaced PGT Industries single hung windows, Series SH-5500, the minimum required wind pressures below are based on FBC 2017 wind load calculations. The applied wind pressures are as follows per the proposed replacement glazed unit for Exposure D, 110 feet in height: (NOA: 20-0401.03): Series: Door or Window: Wind Zone: Applied Wind Pressure: SH-5500 30.9”x49.5” 4 +67.5 / -88.6psf; SH-5500 35.9”x62.0” 4 +64.9 / -86.4 psf; The mullion joining the two SH-5500, by PGT Industries, NOA 20-0406.03 tributary loading meets above applied presuures tranfered from those windows. In reviewing respective NOA for the above windows, the calculated respective design pressures are less than the respective allowable pressures of +70/-110psf, and as such is acceptable to this office. If you have any questions, please contact me at any time. Thank you, Raymond Chladny, B.arch.Sc., M.arch, AIA, NCARB, Lic.#: AR-0017475