Prouct Approval
r USEdR: Public user
�'ratmrr'a� a-
protlnn AnpmvaMe > product
or Aool dtion Search > Application Ust> Application Detail
FL #
FL2569-R19
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
Archived
❑
Product Manufacturer Soprema, Inc. (Canada)
Address/Phone/Email 1640 rue Haggerty
Drummondville, NON -US 00000
(819) 478-2400
m e mathieu @soprema.ca
Authorized Signature Marc -Etienne Mathieu
memath ieu @so pre ma.ca
Technical Representative Marc -Etienne Mathieu
Address/Phone/Email 1688 Jean-Berchmans-Michaud
Drummondville, NON -US 00000
(819) 478-2400 Ext 3327
memathieu@sopremada
Quality Assurance Representative Jean -Francois Cote, Ph.D.
Address/Phone/Email 1640 rue Haggarty
Drummondville
(888) 811-3145
jfcote@soprema.ca
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
F3 Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed RobertJ. M. Nleminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 04/10/2023
Validated By John W. Knezevich, PE
IZ Validation Checklist- Hardcopy Received
Certificate of Independence FL2569 R19 COI R920 01 COI NIEMINEN df
Referenced Standard and Year (of Standard) Standard V
ASTM D1970 2015
ASTM D4798 2011
ASTM D6163 2008
FM 4474 2011
FRSA/TRI April 2012 (04-12) 2012
UL1897 2012
Equivalence of Product Standards
Certified By
https://www.tloridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsKQFEnckB 1... 7/29/2020
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 04/09/2020
Date Validated 04/09/2020
Date Pending FBC Approval 04/14/2020
Date Approved 06/02/2020
Summary of Products
FL #
Model, Number or Name
Description
2569.1
Soprema Roof Underlayments
Self adhering roof underlayments
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-150
Other: 1.) Refer to ER Section 5 for Limits of Use. 2.) The
design pressure noted herein pertains to underlayment
systems used beneath adhesive -set the systems. Refer to ER
FL2569 R19 II 2020 04 06 FINAL ER FL2569-RI9 odf
Verified By: Robert Nieminen, P.E. PE-59166
Created by Independent Third Party; Yes
Evaluation Reports
FL2569 R19 AE 2020 04 06 FINAL ER FL2569-RI9 odf
Created by Independent Third Party: Yes
Section 5.6.4 for details.
onta t Us;: 26n1 Blair Some Road, Tallahassee FL 32399 phone: 850-487-1824
The State of Florida Is an AA/EEO employer. Cooyrlaht 2002-2013 state of Florida :: Privacy Statement :; Accesalbllity Statement ;: Refund Statement
Under Florida law, emall addresses are public records, If you do not want your e-mail address released In response to a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact$50,487.1395. *Pursuant to Section 455.275
(1), Florida Statutes, effective Octaher 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The
ema Its provided may be used for of icial communication with the licensee. However emall addresses are public record. If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please
dickfl_ere .
Product Appraav�val Accepts:
tl7
Credit Card s
Safe
https://www.floridabuilding.org/pripr_app_dtl.aspx?param=wGEVXQwtDgsKQFEnckB 1... 7/29/2020
NEMO ( etc.
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT
4LUATION REPOF
Soprema, Inc. Evaluation Report S18010.06.09-1117
1640 rue Haggerty FL2569-1119
Drummondville, Quebec J2C 5P8 Canada Date of Issuance: 06/15/2009
(819) 478-2400 Revision 17: 04/06/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 61h Edition (2017) Florida Building Code sections noted
herein.
DESCRIPTION: Soprema Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s), the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO Ietc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the jab site at the request of the Building Official.
This Evaluation Report consists of pages 1 through S.
Prepared by:
Roob'ertJ.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
SW 9h r'tr
The facsimile seal appearing was authorized by Hobert
Nieminen, P.E.on 04/06/2020. This does not serve as an
1=y�".•,.n��"'
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC Is not owned, operated or controlled by any company manufacturing or distributing products It evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMOI etc. nor Robert Nieminen, P.E. are, in anyway, the Designer of Record for any project
on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically
for that purpose.
02019 NEMO ETC, LLC
NEMO I etc.
Sub -Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the
following sections of the 611 Edition (2017) Florida Building Code through testing in accordance with the following
Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth
herein.
jecawn: ;;
..rroaerw
::xanaarm,
Year,
1504.3.1
Wind Resistance
FM 4474
2011
1504.3.1
Wind Uplift
UL 1897
2012
1507.1.1, 1507.2.9.2, R905.1.1,
Physical Properties
ASTM D1970
2015
R905.2.8.2
1507.3.3, R905.3.3
Physical Properties
FRSA/TRI April 2012
2012
FRSA/TRI April 2012 (04-12)
Physical Properties
ASTM D6163
2008
TAS 110
Accelerated Weathering
ASTM D4798
2011
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TSTG049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
M-D (CER1592)
ICC-ES (EVL2396)
NEMO (TST6049)
NEMO (TST6049)
NEMO (TST6049)
NEMO (TST6049)
NEMO (TST6049)
PRI(TST5878)
Soprema, Inc. (PDM3511)
UL, LLC(QUA9625)
UL, LLC(QUA9625)
:Examination: ;'
Reference;
Date
Wind Resistance
2778,07.05
07/15/2005
ASTM D1970/TAS 110 (QC)
S31370.03.10-1-R1
04/07/2010
FRSA/TR1 04-12 (OH)
S11150.05.09-R2
10/05/2010
ASTM D1970 (OH)
S37210.11.11
11/09/2011
ASTM D1970 (MS)
S37210.12.11
12/01/2011
ASTM D1970 (MS)
S40540.02.13-1
02/19/2013
FRSA/TRI 04-12 (MS)
S43530.02.14-1-R1
02/21/2014
ASTM D1970(13C)
S44870.04.14-2
04/02/2014
ASTM D1970 (QC)
544870.04.14-3
04/02/2014
ASTM D1970 (OH)
544870.04.14-1
04/10/2014
ASTM D1970 (MS)
S44870.04.14-4
04/10/2014
ASTM D1970 (OH)
S40540.10.14
10/31/2014
Tensile Adhesion / Long Term Aging
SOPC-SC7645.02.15
02/13/2015
Accelerated Weathering
SOPC-SC8520.04.14
04/27/2015
Wind Resistance
SOPC-SC14045.05.17-R1
06/07/2017
HVHZ Compliance
18-0329.03
06/28/2018
20151BC Compliance
ESR-1524
03/01/2017
ASTM D1970 /TAS 110 (QC)
SOPC-SC8970.08.15-RI
04/25/2018
Wind Resistance
4-SOPC-18-003.08.18
08/27/2018
ASTM D4798/1)1970 (OH & MS)
4S-SOPC-18-002.05.19.A
05/31/2019
Tensile Adhesion/Long Term Aging _
4p-DOW-I9-SSLAP-01.A.R2
02/10/2020
Peel adhesion (existing underlayments)
4j-SOPC-I9-SSUDL-04.A
03/12/2020
ASTM D1970 (MS)
SOP-064-02-01
12/03/2013
Equivalency Declaration
SA SMOOTH PLY 40
06/29/2015
Quality Control
MLA File No. R27605
05/08/2019
Quality Control
Service Confirmation
07/18/2017
NEMO ETC, LLC Evaluation Report $18010.06.09-R17
Certificate of Authorization #32455 6Te EDITION (2017) FBC NON-HVHZ EVALUATION FL2569-1119
Soprema Roof Underlayments Revision 17: 04/06/2020
Page 2 of 8
NEmo I etc.
4::PRC�DUC7 DESRIhT[ON
Rraducit , :". ..
": Spciircatton
description ;.
4.1
Lastobond TU HT
ASTM D1970 and
Gulfport, MS
self -adhering, non -woven polyester fabric surfaced,
FRSA/TRI April 2012
SBS modified bitumen roof underlayment
4.2
Lastobond Shield
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, SBS
modified bitumen roof underlayment available in
two widths; 36 and 45 inch
4.3
RESISTO SA SMOOTH PLY
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, SBS
40
modified bitumen roof underlayment
4.4
Lastobond Shield HT
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof
underlayment
4.5
Lastobond Pro HT-N
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, SBS
modified bitumen roof underlayment available in
two widths; 36 and 45 inch
4.6
Lastobond Pro HT-S
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof
underlayment
4,7
EnviroShield
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof
underlayment
4,8
Lastobond 195
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, sand -surfaced,
Wadsworth, OH
SBS modified bitumen roof underlayment
4.9
Lastobond Eaves
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, sand -surfaced,
Protection Sheet
Wadsworth, OH
SBS modified bitumen roof underlayment
4.10
Lastobond Eco
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -surfaced,
Gulfport, MS
SBS modified bitumen roof underlayment
Wadsworth, OH
4,11
Lastobond Smooth Seal
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, film -surfaced,
HT
Wadsworth, OH
SBS modified bitumen roof underlayment
4.12
PrimeSource Grip -Rite
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, film -surfaced,
Smooth Seal HT
Wadsworth, OH
SBS modified bitumen roof underlayment
4.13
RESISTO LB1236
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -surfaced,
Gulfport, MS
SBS modified bitumen roof underlayment
Wadsworth, OH
4.14
PrimeSource Grip -Rite
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -surfaced,
Eave & Valley Protector
Gulfport, MS
SBS modified bitumen roof underlayment
Wadsworth, OH
4.15
SRS TopShield ICE &
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -surfaced,
WATER DEFENDER
Gulfport, MS
SBS modified bitumen roof underlayment
Wadsworth, OH
4.16
RESISTO LB1244
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -surfaced,
Gulfport, MS
SBS modified bitumen roof underlayment
Wadsworth, OH
4.17
Colphene FR GR
ASTM D1970 and
Gulfport, MS
self -adhering, fiberglass reinforced, granule-
FRSA/TRI April 2012
Wadsworth, OH
surfaced, SIBS modified bitumen roof underlayment
MEMO ETC, I.LC
Certificate of Authorization #32455 6m EDITION 12017) FBC NON-HVHZ EVALUATION
soprema Roof Underlayments
Evaluation Report S18010,06.09-R17
FL2569-R19
Revision 17: 04/06/Z020
Page 3of8
NEMO I etc.
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of
this product.
5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request maybe made to the Authority Having Jurisdiction for approval
based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable Roof Covers:
f _ TABL£
1' ROOFOVERPY1ONS
Wood pr :
Slate or
Underiayment
Asphalt
Nail On '
Foam On
Metal
Composite
Composite,
ffi
Tile
Shakes&'
`
Shmgle5-
$Iate
Lastobond TU HT
Yes
Yes
Yes
Yes
Yes
Yes
See 55A
Lastobond Shield / Pro HT-N /
RESISTO SA SMOOTH PLY 40
Yes
No
No
No
Yes
Yes
Lastobond Shield HT / Pro HT-S
Yes
No
No
Yes
Yes
Yes
EnviroShield
Yes
No
No
Yes
Yes
Yes
Lastobond Eaves Protection Sheet/
Lastobond 195
Yes
No
No
No
Yes
Yes
Lastobond ECO / RESISTO LB1236,
Grip -Rite Eave & Valley Protector/
TopShield ICE & WATER DEFENDER /
Yes
No
No
No
Yes
Yes
RESISTO L61244
Lastobond Smooth Seal HT / Grip-
Rite Smooth Seal HT
Yes
No
No
Yes
Yes
Yes
Colphene FR GR
Yes
Yes
No I
No
Yes
Yes
5.5.1 "Foam -On Tile" is limited to use of following Approved tile adhesives /underlayment combinations.
TAi3LE 1A''ALLDWEI6LE T[LE'QOESIIIE UNDERLAYMeNL COMBINATION51 ,;;
Underiayment ..,
Adhesive
Florida Product -Approval
Lastobond TU HT
Dupont TILE BOND'""
FL22525
ICP Adhesives Polyset® AH-160
FL6332
i Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC, LLC Evaluation Report S18010.06.09-R17
Certificate of Authorization #32455 6rH EDITION (20171 FBC NON-HVHZ EVALUATION FL2569-1119
Soprema Roof Underlayments Revision 17: 04/06/2020
Page 4 of 8
NEMO j etc.
5.6 Allowable Substrates:
= SIJBSTRATEOPTfpKS� '
.-: M. __�PBLE2
.; underayment,
Primer
Substrates
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA
(Optional) ASTM D41,
SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S,
Elastocol Stick, Elastocol Stick
plywood, D$B, Southern Yellow
EnviroShleld, Lastobond TU HT, Lastobond Eaves Protection
Zero
pine (SYP)
Sheet, Lastobond 195, Lastobond ECO, RESISTO LB1236,
Grip -Rite Eave & Valley Protector, TopShield ICE & WATER
-
DEFENDER, RESISTO LB1244, Lastobond Smooth Seal HT or
ASTM D41
structural concrete
Grip -Rite Smooth Seal HT
Colphene FIR GR
(Optional) ASTM D41
Plywood
ASTM D41
structural concrete
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA
SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S,
EnviroShield, Lastobond TU HT, Lastobond Eaves Protection
Dens Deck Prime; SECUROCK
Sheet, Lastobond 195, Lastobond ECO, RESISTO LB1236,
(Optional) Elastocol Stick Zero
B
Gypsum -Fiber Roof Board;
Gypsum-Fiber
Grip -Rite Eave & Valley Protector, TopShield ICE & WATER
ASTM
ASTM D226, Type II felt;
DEFENDER, RESISTO LB1244, Lastobond Smooth Seal HT,
G; Modified Sopra-1
Grip -Rite Smooth Seal HT or Colphene FR GR
Existing sand -surfaced, glass-
RESISTO LB1236, Grip -Rite Eave & Valley Protector or
fiber surfaced, mineral -surfaced
TopShield ICE & WATER DEFENDER
RESISTO EXTERIOR PRIMER
or film -surfaced roof
underlayment*
* Final acceptance of any existing substrate in a reroof (tear -off) installation isat the discretion of the installer and the Authorlty
Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive RESISTO LB1236, Grip -Rite
Eave & Valley Protector or TopShield ICE & WATER DEFENDER self -adhering underloyments, contact RESISTO technical support.
5.6.1 Soprema recommends priming with Elastocol Stick; Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof
cover is not slated for installation within 24 hours.
5.6.2 Soprema requires tongue -and -groove board decking be covered with plywood or OSB prior to installation of the
self -adhering underlayment
5.6.3 For installation under mechanically attached prepared roof coverings, insulation or coverboard shall be attached
per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam -on tile systems (Lastobond TU HT only), insulation attachment shall be designed by a qualified design
professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474,
Appendix D, Testing Application Standard TAS 114, Appendix J or UL1897.
5.6.4 For installations under mechanically attached prepared roof coverings, base sheet shall be attached per minimum
codified requirements. For installations under foam -on tile systems (Lastobond TU HT only), base sheet shall be
attached in accordance with FRSA/TRI April 2012 (04-12) or Section 5.6.5 herein.
5.6.5 Wind Resistance for Underlavment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not
address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment
forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not
addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is
the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing
pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI
April 2012 (04-12) or FBC 1609 for determination of design wind pressures.
NEMO ETC, LLC Evaluation Report 516010.06.09-1117
Certificate ofAuthoriration #32455 6Te EDITION (2017) FBC NON-HVHZ EVALUATION FL2569-R19
Soprema Roof Underlayments Revision 17: 04/06/2020
Page 5 of 8
NEMO l etc.
#1 Maximum Design Pressure = -45.0 osf:
Deck:
Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer:
(Optional) Elastocol Stick, Elastocol Stick Zero or RESISTO EXTERIOR PRIMER
Underlayment:
Lastobond TU HT, self -adhered; thoroughly rolled using hand roller and/or weighted roller in
accordance with Soprema requirements to ensure no voids no bridging at side and end -laps.
#2 Maximum Design Pressure =-67.5 osf:
Deck:
Structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer:
Elastocol Stick Zero
Underlayment:
Lastobond TU HT, self -adhered; thoroughly rolled using hand roller and/or weighted roller in
accordance with Soprema requirements to ensure no voids no bridging at side and end -laps.
#3 Maximum Design Pressure=-120.0 Dsf:
Deck:
Min. 15/32-inch APA-rated CDX plywood to meet project requirements to satisfaction of
Authority Having Jurisdiction.
Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All
sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood
projections shall be removed/sanded.
Primer:
(Optional) RESISTO EXTERIOR PRIMER
Base Ply:
RESISTO SA SMOOTH PLY 40, self -adhered; thoroughly rolled using hand roller and/or weighted
roller in accordance with Soprema requirements to ensure no voids no bridging at side and end -
laps.
Underlayment:
Lastobond TU HT, self -adhered; thoroughly rolled using hand roller and/or weighted roller in
accordance with Soprema requirements to ensure no voids no bridging at side and end -laps.
#4 Maximum Design Pressure=-150.0 DO
Deck: Min, 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project
requirements to satisfaction of Authority Having Jurisdiction.
Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All
sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood
projections shall be removed/sanded.
Primer: (Optional) RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT, self -adhered; thoroughly rolled using hand roller and/or weighted roller in
accordance with Soprema requirements to ensure no voids no bridging at side and end -laps.
#5 Maximum Design Pressure=-60.0 Ds :
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (FBC
1517.5.2) spaced 6-inch o.c. at the 4-inch laps and 6-inch o.c. in three (3), equally spaced rows
in the center of the sheet.
Underlayment: Lastobond TU HT, self -adhered; thoroughly rolled using hand roller and/or weighted roller in
accordance with Soprema requirements to ensure no voids no bridging at side and end -laps
5.6.5.1 All other direct -deck, adhered Soprema underlayment systems beneath foam -on tile systems carry a Maximum
Design Pressure of -45 psf.
NEIVO ETC, LLC Evaluation Report 518030.06.09-1137
Certificate ofAuthorization #32455 0 EDITION (2017) FBC NON-HVHZ EVALUATION FL2569-R19
Soprema Roof Underlayments Revision 17: 04/06/2020
Page 6 of 8
'k.. NEMOIetc.
5.6.5.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or
exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table IA.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design
pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density
designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are
ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies
marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29
(January 2016) for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco, RESISTO LB1236, Grip -Rite Eave & Valley
Protector, TopShield ICE & WATER DEFENDER or RESISTO LB1244 shall not be left exposed for longer than 30-days
after installation.
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S,
EnviroShield, Lastobond Smooth Seal HT or Grip -Rite Smooth Seal HT shall not be left exposed for longer than 90-
days after installation.
Lastobond TU HT or Colphene FR GR shall not be left exposed for longer than 180-days after installation.
5.8 Tile Slippage Limitations (TAS 103 Per FRSA/TRI April 2012 (04-12))•
When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
-
I— LIPPAGE LINIf1;A410NS f)�ItE
,�.' ,TRQR O sr'g-TILE:INSTALLATIbN4;?
Upderlayment,' _
' Tile Profile
;Staging Method i" Maximum '
Slope
Flat
Max. 10-tile stack 6:12
Lugged
Max. 10-tile stack 5:12
Max. 10-tile stack (bottom 2-tile stack shall be inverted,
followed by 8 tiles high on slope, as shown below)
6:12
Lastobond TU HT
Lugged
�t
Colphene FR GR
Flat
Max. 30-tile stack 5:12
Lugged
Max. 10-tile stack 111 :12
NEMO ETC, LLC Evaluation Report S18010.06.09-1117
Certificate of Authorixotion#32455 0 EDITION (2017) FBC NON-HVHZ EVALUATION FL2569-R39
Soprema Roof Underlayments Revision 17; 04/06/2020
Page 7 of 8
NEMO I etc.
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application, and prime the substrate with Elastocol Stick, Elastocol Stick Zero or RESISTO
EXTERIOR PRIMER (if applicable).
6.2.1 Installation of RESISTO LB1236, Grip -Rite Eave & Valley Protector or TopShield ICE & WATER DEFENDER self -adhering
underlayment in a reroof (tear -off) application atop an existing underlayment (per Table 2) requires priming of the
existing substrate with RESISTO EXTERIOR PRIMER. Final acceptance of any existing substrate in a reroof (tear -off)
installation is at the discretion of the installer and the Authority Having Jurisdiction. Should a question arise as to
the suitability of an existing substrate to receive RESISTO LB1236, Grip -Rite Eave & Valley Protector or TopShield ICE
& WATER DEFENDER self -adhering underlayments, contact RESISTO technical support.
6.3
Lastobond TU HT, Lait6b6nd=ShIeId, Lastobond Pm;HT-N, RESISTO SA SMOOTH PLY 40 Lastobpnd.Shield HT,
Lastiibood Is, HT-S, EnuiroSi"jeld, Lastobond Eaves Protection S- eet, Lastobond 195, Lastobond Eco, Lastobond'
Smooth Seal HT; Grip-Rite.Smaoth Seal H7, RESIST0-LB1236; Gt p-Rite Eave & Valley Protector, TopShield ICE &
EFEND WATER DER,, RESISTO L'B1244 or Colphene FIRGR:
6.3.1 Non -Tile Applications:
Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507,1.1 or FBC
Residential Table R905.1.1 for the type of prepared roof covering to be installed, and Soprema published
requirements.
6.3.2 Tile Applications (Lastobond TU HT or Colphene FR GR only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual for Self -Adhered Membrane, and Soprema
published requirements.
For mechanically fastened the roofing over a 2-ply system, consisting of Base Sheet and Self -Adhered Membrane,
fastening of the ASTM D226, Type II base sheet shall be in accordancewith Soprema requirements, but not less than
that the densities set forth in FRSA/TRI April 2012 (04-12), Table 1.
For foam -on tile applications (Lastobond TU HT only), reference is made to Section 5.6.5 herein for wind resistance
limitations that fall outside the scope of FRSA/TRI April 2012 (04-12).
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. See
Table 3 herein, and Soprema published requirements for tile staging.
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
Contact the noted CIA agency for information on product locations covered for F.A.C. 61G20.3 CIA requirements.
Refer to Section 4 herein for product & production locations having met codified physical properties specifications.
UL, LLC—QUA9625; (314) 578-3406; k.chancellor@us.ul.com
- END OF EVALUATION REPORT -
NEMO ETC, LLC Evaluation Report S18010.06.09-1117
Certificate of Authorization H32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL2569-1119
Soprema Roof Underlayments Revision 17: 04/06/2020
Page 8 of 8