Loading...
HomeMy WebLinkAboutmetal building product approvalSTRUCTURAL DESIGN ENCLOSED BUILDING EXPOSURE B MAXIMUM 309-0" WIDE X 209-0" EAVE HEIGHT- BOX EAVE FRAME AND BOW FRAME 18 December 2017 Revision 4 M&A Project No. 16022S/17300S Prepared for: Tubular Building Systems, LLC 631 SE Industrial Circle Lake City, Florida 32025 Prepared by: Moore and Associates Engineering and Consulting, Inc. 1009 East Avenue North Augusta, SC 29841 ,```,�1E 1 S. �1O 401 S. Main Street, Suite 200 Mount Airy, `�.��P'�•.\ C'E N S ' 0 •'�, F •• NC 27030 No 57170 Digitally signed - * : •: * = by Wayne S Moore ;-33 STATE OF :�,: IIJ Date: :0. P.� 00 .104'00' MOOR O ASOOCIAT SENGIN S'ONAL��.,`,�� 10.01 ERIN ��111111111\♦ This item has been electronically signed and sealed by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. r S, A40,,,' 0 No 57170 �r� �� •• STATE OF ' I/ ` .O•• i�Sis,O N rriir,l This item has been electronically signed and sealed by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. MOORE AND ASSOCIATES DRAVN BYr LT TUBULAR BUILDING SYSTEMS 30'-0"x20'-0" ENCLOSED BUILDING EXP. B CHECKED BY- PDH ENGINEERING AND CONSULTING, INC. PE SEAL COVER SHEET PROJECT rlGltr VSM DATE, 12-18—,7 SCALES NTS AB ND S TFGS Ir,C1Ert]iT 1S TFE PRlpER1Y tF rtOiE Arlo ASStlCIATES E7lG4FERI1IG AKO CMCLLTM TW LRMUTTER= F9371MUCTION, 0011YM OR QTHUMSC JAE OF CLIENT, TBS ISHT. 1 VG. ND SK-3 ¢ 4 TMI DOMNDff ,S STRMY PlMURTTED NO ANY i IUNGEM111M TFERELrw MAY X SUNJOCT TO UEGAL ACTION. DRAWING INDEX SHEET 1 PE SEAL COVER SHEET SHEET 2 DRAWING INDEX SHEET 3 INSTALLATI❑N NOTES AND SPECIFICATI❑NS SHEET 4 TYPICAL SIDE AND END ELEVATI❑NS SHEET 5 TYPICAL RAFTER COLUMN END AND SIDE FRAMING SECTI❑NS (BOX EAVE RAFTER) SHEET SA TYPICAL RAFTER COLUMN C❑NNECTI❑N DETAILS (LACED COLUMN) SHEET eB TYPICAL RAFTER COLUMN C❑NNECTI❑N DETAILS (DOUBLE COLUMN) SHEET SC TYPICAL RAFTER COLUMN C❑NNECTI❑N DETAILS (SINGLE COLUMN) SHEET 7 TYPICAL RAFTER COLUMN END AND SIDE FRAMING SECTI❑NS (BOW RAFTER) SHEET 8A TYPICAL RAFTER COLUMN C❑NNECTI❑N DETAILS (DOUBLE COLUMN) SHEET 813 TYPICAL RAFTER COLUMN C❑NNECTI❑N DETAILS (SINGLE COLUMN) SHEET 9A BASE RAIL ANCHORAGE ❑PTI❑NS SHEET 9B ❑PTI❑NAL F❑UNDATI❑N ANCHORAGE SHEET 10 TYPICAL END WALL AND SIDE WALL ❑PENING FRAMING SECTI❑NS (B❑X EAVE RAFTER) SHEET 11 TYPICAL END WALL AND SIDE WALL ❑PENING FRAMING SECTI❑NS (BOW RAFTER) SHEET 12 WALL ❑PENING DETAILS SHEET 13 LEAN-TO ❑PTI❑NS (BOX EAVE RAFTER) SHEET 14 LEAN-T❑ ❑PTI❑NS (BOW RAFTER) SHEET 15 VERTICAL R❑❑F/SIDING ❑PTI❑N END AND SIDE ELEVATI❑N AND SECTI❑N SHEET I ❑PTI❑NAL DOOR HEADER .%�, . . S MHO ��4' %• No 57170 ' STATE OF JZ This item has been electronically signed and sealed by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. MOORE AND ASSOCIATES I MAVN Bn LT TUBULAR BUILDING SYSTEMS ENGINEERING AND CONSULTING, INC. 1cwcKa BY. PBH 30'-0"x20'-0° ENCLOSED BUILDING EXP. B JOB 10 Has nommiaff is THE PRwmTy IF Room va ASSOICIATES Inc AND tPROJE.CT NM WSN DATE, 12-18-17 SCALE, KTS 16022S/173005 Ml.SI1LTDa THE UNAU7? D REPRamc IQ , cIpywa aR OiIERVISE USE IIf nas L13CUIEHr IS STRICTLY PROMIFFEA AM AWY DFIMMENT T1EMrl3N IIAY IE SUBJWt TO LEGAL ACT]DL i T11S SHT. 2 VG. M SK-3 EV.= 4 INSTALLATION NOTES AND SPECIFICATIONS 1 DESIGN IS FOR A MAXIMUM 30-0" WIDE x 20-0' EAVE HEIGHT ENCLOSED STRUCTURES 2, DESIGN WAS DONE IN ACCORDANCE WITH THE 2017 FLORIDA BUILDING CODE (FBC) 6TH EDITION, 2612 INTERNATIONAL BUILDING CODE (IBC), AND 2015 IBC. 3 DESIGN LOADS ARE AS FOLLOWS: A) DEAD LOAD = 1.5 PSF B) LIVE LOAD = 12 PSF C) GROUND SNOW LOAD = 10 PSF 4 LOW ULTIMATE WIND SPEED 105 TO 140 MPH (NOMINAL WIND SPEED 81 TO 108 MPH) MAXIMUM RAFTER/POST AND END POST SPACING = 50 FEET 5. HIGH ULTIMATE WIND SPEED 141 TO 170 MPH (NOMINAL WIND SPEED 109 TO 132 MPH) MAXIMUM RAFTER/POST AND END POST SPACING = 40 FEET 6. LOW HAZARD RISK CATEGORY I (WIND) 7 WIND EXPOSURE CATEGORY B 8. SPECIFICATIONS APPLICABLE TO 29 GAUGE METAL PANELS FASTENED DIRECTLY TO 2 112' x 2 1/2" - 14 GAUGE TUBE STEEL (TS) FRAMING MEMBERS, FOR VERTICAL PANELS, 29 GAUGE METAL PANELS SHALL BE FASTENED TO 18 GAUGE HAT CHANNELS (UNLESS OTHERWISE NOTED), 9 AVERAGE FASTENER SPACING ON-CENTEP.S ALONG RAFTERS OR PURLINS, AND POSTS, INTERIOR = 9' OR END = 6', (MAX) 10 FASTENERS CONSIST OF #12-14x3/4' SELF -DRILLING FASTENER (SDF), USE CONTROL SEAL WASHER WITH EXTERIOR FASTENERS SPECIFICATI➢NS APPLICABLE ONLY FOR MEAN ROOF HEIGHT OF 20 FEET OR LESS, AND ROOF SLOPES OF 14' (312 PITCH) OR LESS SPACING REQUIREMENTS FOR EITHER ROOF HEIGHTS AND/OR SLOPES MAY VARY, 11 GROUND ANCHORS SHALL BE INSTALLED THROUGH BASE RAIL WITHIN 6" ❑F EACH RAFTER. COLUMN ALONG SIDES 12 GROUND ANCHORS (SOIL NAILS) CONSIST ❑F #4 REBAR W/WELDED NUT x 30' LONG IN SUITABLE SOIL CONDITIONS MAY BE USED FOR LOW ( 108 MPH NOMINAL) WIND SPEEDS ONLY, ❑PTIONAL ANCHORAGE MAY BE USED IN SUITABLE SOILS AND MUST BE USE IN UNSUITABLE SOILS AS NOTED 13 ❑PTIONAL BASE RAIL ANCHORAGE MAY BE USED FOP. LOW AND MUST BE USED FOP, HIGH WIND SPEEDS 14, WIND FORCES GOVERN OVER SEISMIC FORCES, SEISMIC PARAMETERS ANALYZED ARE SOIL SITE CLASS = D RISK CATEGORY I/II/III R- 3.25 IE= 10 SDS= 1.522 V= CSW Sol= 0 839 MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. CONSILTIM IfE UKVJnCr4= THIS LOCUMM IS S710mY P X StOLECT TG LEGAL ACTEX ff MAY S. 1 MOO GENS No 57170 rr �� •• STATE OF ' I/ ` ;Q rrIIr11 This item has been electronically signed and sealed by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. TUBULAR BUILDING SYSTEMS 30'-0"x2O'-O" ENCLOSED BUILDING EXP. B JOB NO -1817 SCALE, NTS 160 /17300 3 WC% NOr SK-3 EV.1 4 BOX EAVE FRAME RAFTER ENCLOSED BUILDING POLL -UP DOER (AS APPLICABLE) DEEP DESIGN PRESSURE CAS APPLICABLE LOW = 1185 PSF, -20.4 PSF, DES ION LOW = PRE8 PSF, -226 PSF)SUPE IC = (2795 PC,F, -30,7 PSF)(20 - F HIGH = (3135 PSF, -3415 PSF) MAXIMUM RAFTER SPAN (W) J TYPICAL END ELEVATI❑N-H❑RIZ❑NTAL ROOF BOW FRAME RAFTER ENCLOSED BUILDING ROLL -UP DOOR (AS APPLICABLE) — SWINGING DOOR DESIGN PRESSURE (AS APPLICABLE LOW = (185 PSF, -204 PSF) DESIGN PRESCOPE HIGH = (27.95 PSF, -307 PSF) . ` LOW = (208PSF, -226 PSF) HIGH = (31.35 PSF, -3415 PSF) —FiAV41k, MA'+]r'HK ?PFTEF ,PAN •.W TYPICAL END ELEVATION SCALE: NT, WINBCW (AS AFFLICABLE DESICN PRESSURE LOW = (218 PSF, -236 FSF) FIGH = 13285 PcF -356 P--F) TYPICAL SIDE ELEVATION SCALE NITS MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC DO =I. MY IS IFE PROPERTY OF MW NO MSOCL M Ek1Md3W G AMO WINDOW (AS APPLICABLE, DESIGN PRESSURE LOW = (218 PSF, -236 P-F) HIGH = Q285 P'F, -35.6 PSF, LENGTH VARIES DEPENDING ON NUMBER AND L.'.. ' -P TEP.S TYPICAL SIDE ELEVATI❑N-H❑RIZ❑NTAL ROOF SCALE NITS +S�,M11111 0 E v I No 571 70 Ste'. STATE OF OR This item has been electronically signed and sealed by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. DRAWN BY, LT TUBULAR BUILDING SYSTEMS 30'-0"x2O'-0" ENCLOSED BUILDING EXP. B CHECKED BYr PDH AB NO . 4 JDWQ NOr SK. 4 SK-3�EW,+ 44 29 GA GALVANIZED METAL ROOF AND WAL1. PANELS FASTENED TO RAFTERS AND POSTS �3 24- 18 GA U-CHANNEL BRACE FASTENED TO RAFTER WITH (4) Il #12-14 x3/4' SDF'S AT EACH END (8 PER BRACE) u I � v f Rr :'•0' , 1{NIyM RAFT` TYPICAL RAFTER/COLUMN END FRAME SECTION SCALE: Ni 29 GA GALVANIZED METAL P.00F AND :- PANELS FASTENED TO RAFTERS AND POSTS - 24' 18 GA U-CHANNEL BRACE FASTENED TO litl RAFTER WITH (4) 412-14x 3/4' SDF'S AT EACH END (8 PER BRACE) z I 0 i r 7 s 29 GA GALVANIZED METAL ROOF AND WALL PANELS FASTENED TO RAFTERS AND POSTS �24' 18 GA U-CHANNEL BRACE FASTENED TO RAFTER WITH (4) 612-14 x 3/4' SDF'S AT EACH END (8 PER BRACE) 30-0' MAXIMUM RAFTER SPAN TYPICAL RAFTER/COLUMN END FRAME SEECTION SCALE; NITS SEE NOTES (SHEET 3) FOR MAXIMUM LENGTH =a DEPENDING ON NUMBER AND 1 TYPICAL RAFTER/COLUMN END FRAME SECTION TYPICAL RAFTER/COLUMN SIDE FRAMING SECTION SCAB MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. 603WI UCTM, COPYM, Ot CM *U3= NO Mil' DFRU9339M No 571 70 Ste'. STATE OF This item has been electronically signed and sealed by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies- TUBULAR BUILDING SYSTEMS 30'-0"x20'-0" ENCLOSED BUILDING EXP. B JOB ND — 7 r NTS 5 WCti M SK-3 d 4 10 TS COLUMN - TS ROOF RAFTER. 3/16 'FP101E: TOO SLEEVE TO 3/16 RAFTER CTYPJ r� l _MINIMUM 6' LONG, MINIMUM 15 GATS NIPPLE. SECURE Y PO , ST TO NIPPLE WITH (4) qi #12-14:<3/4" SDF'S 3/16 ivp 3/16 I r, 43• SECURE WITH (4) 1112-14r3/4' SDF'S (EACH END) -)E GA U-CHANNEL BRACE TS COLUMN MINIMUM 6' MINIMUM IS GA,.T•5 NIPPLE SECURE WITH (4) #12-14s3/4' SDF'S .p i �'i 3/16 —TS CHORD I -'• SLEEVE TO RAIL TS CONTIT¢tn4 -.. I I BASE RAIL � R� w1 Ilf I I III RAFTER COLUMN/BASE RAIL 2 CONNECTION DETAIL BOX EAVE RAFTER COLUMN CONNECTION DETAIL 1 FOR HEIGHTS 16'-0- < TO ! 20'-0- 1 CA U-CHANNEL BRACE FASTENED TO THE COLUMN AND ROOF BEAM, WITH (4) #12-14x3/4' SDF'S AT EACH 2 1/2, _ END (B PER BRACE: BRACE SECTION SC MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. TFDS D0:1M f U 7W PROPERTY Or N M AND ASSOMM EPIaM M AND COrS1LT m 7w 1RIM naam REPROIU nX COPYM Ot QitEMK USE O' THU DOCUENT IS STRWTLY PROOIITED AND ANY DFRDIG MDif THEREtPM NAY E SIO= M LEGAL ACTmi No 57170 - STATE OF 111111111111100 This item has been electronically signed and sealed by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies - DRAWN BY, LT TUBULAR BUILDING SYSTEMS 30'-0"x2O'—O" ENCLOSED BUILDING EXP. B CHECKED We PDH AB NOr 6A `OWC, ND SK-3 PEV.1 4 SECURE WITH (4) #12-14x3/9" ' SDF'S (EACH END) TS RnnF RAFTFF'_ CONNECTOR 3/16 SLEEVE TO RAFTER 3/16 (TYP.) MINIMUM 6' LONG, — MINIMUM 15 GA TS NIPPLE. SECURE POST TO NIPPLE WITH (4) 012-14.x3/4' SDF'S 18 GA. U-CHANNEL BRACE 1. 3-12 3-12 TS DOUBLE COLUMN t,- BOX EAVE RAFTER COLUMN CONNECTION DETAIL FOR HEIGHTS 14'-0' < TO �, 16'-0- SCALE N GA U-CHANNEL BRACE ASTENED TO THE COLUMN AND REEF BEAM, WITH (4) #12-14-3/4' S➢F'S AT EACH 2 1/2" END (8 PER BRACE) BRACE SECTION SCALE NTS MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. NO tiS=rAMS 3-12 �i$ DOUBLE COLUMN 3-12 r•�. MINIMUM 6' LONG, CONNECTOR SLEEVE MINIMUM 15 GA, SLEEVE TO 3/16 SECURE WITH SDF'S BASE RAIL _ N12-19 x3/4" SDF'S TS CONTINUOUS BASE RAIL i— I- RAFTER COLUMN/BASE RAIL r 2 CONNECTION DETAIL j J Ns 1 S. UOO',', No 57170 e STATE OF &J A` E.�. This item has been electronically signed and sealed by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. TUBULAR BUILDING SYSTEMS 30'-0"x20'-0" ENCLOSED BUILDING EXP. B JOB 10 EI 12- 8-17 SCALD NTS 173MS 6H Cs ND SK-3 EW 4 SECURE WITH— (4) #12_LL'3/4' SDF'S (EACH END) TS ROOF PAFTEP CONNECTOR 3/16 SLEEVE _ TO RAFTER 3/16 3 _ 6' MINIMUM 6' LONG, y: MINIMUM 15 GA, TS NIPPLE SECURE POST TO NIPPLE WITH (4) #12-14x3/4' SDF'S t;o l 18 GA U-CHANNEL BRACE TS COLUMN 3 3 —I, 2 1/4'x2 1/4-14 GA in REINFURCING 6'-0' LONG (HW) AND 5-0' LONG (LW) SECURE WITH (10) H]2-14x3/4' SDF'S BOX EAVE RAFTER COLUMN --- C❑NNECTI❑N DETAIL A FOR HEIGHTS 10'-0' < TO S 14'-0' f_TS COLUMN I MINIMUM 6' LONG, SLEEVE TO 3/l6 CONNECTOR SLEEVE BASE RAIL "' MINIMUM ]5 GA, 3/i6 SECURE WITH (4) #12-14a3/4' S➢E'S —TS CONTINUOUS -� BASE RAIL RAFTER COLUMN/BASE RAIL 2 C❑NNECTI❑N DETAIL MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. THIS r=Mff IS TI£ PR FUM IF MW Alm LUTES EPM6 MM Alm COISILnm 7M lUtAIRTOtom RFPR10mcn 6 cIPYM Q QTIf wm USE IF THIS DOCUENT IS STRICTLY PRQ4urli Alm ANY DFnxill T TFERE M MY x SIA = M LEGAL &mx TS ROOF NATtEF CONNECTOR 3/16�� SLEEVE 12 4 70 RAFTER 3/16 3 �t 9 ts, — sEGuaE WITH 6, SDF'S (EACH END) 9 •: MINIMUM 6' MINIMUM 15 GA TS NIPPLE SECURE 18 GA U-CHANNEL BRACE POST TO NIPPLE WITH (4) 012-14x3/4' SDF'S 10 TS COLUMN— . B❑X EAVE RAFTER COLUMN C❑NNECTI❑N DETAIL 1 B FOR HEIGHTS i 10'-0' W 19 GA. U-CHANNEL BRACE FASTENED TO THE COLUMN AND ROOF BEAM. WITH (4) #12-14x3/4' S➢F'S AT EACH 2 1/21 END (8 PER BRACE) BRACE SECTI❑N D I.ALE: N I J No 57170 'n • e•l z STATE OF &J j O •�. A" ice, �s O R -"fSj0NA` E %% '11111This item has been electronically signed and sealed by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. TUBULAR BUILDING SYSTEMS 30'-0"x20'-0" ENCLOSED BUILDING EXP. B JOB ra . 6C 1 ND SK-3 ' 4 29 GA GALVANIZED METAL ROOF AND WALL - PANELS FASTENED TO RAFTERS AND POSTS 24' 18 GA U-CHANNEL BRACE FASTENED TO RAFTER WITH (4) 0 12-14r 3/4' SDF'S AT EACH END (8 PER BRACE) Li L:67-V PAL I TYPICAL RAFTER/COLUMN END FRAME SECTION SCALE NTS SEE NOTES SHEET 3) FOR MAXIMUM LENGTH VARIES DEPENDING ON NUMBER AND SPACING ❑F --. TYPICAL RAFTER/COLUMN SIDE FRAMING SECTION MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. nos aacu€ m is YFE PRi/'ERrY IF HIM& Alm AS=IAM EPIMIMME NO C13OWTIM M kXhJn0M= M7EW, LWMQ, [R arFE MSE USE aF TMS 1110 EN17 IS STRICTLY FRTIRMITED AND ANY i€"V✓WHENT TFEFOAM4 MAY BE SUBJECT ra LEGAL ACTKPL uI 29 GA GALVANIZED METAL RUDE AND WAIL1 PANELS FASTENED TO RAFTERS AND POSTS — 24' 18 GA U-CHANNEL BRACE FASTENED TO RAFTER WITH (4) N12-14x3/4' SDF'S AT EACH END (8 PER 13P.ACE) TYPICAL RAFTER/COLUMN END FRAME SECTION S„A4OO,,,, No 571 70 �e': � 51 STATE OF ' I/ ` 4 OR o �=% O N Ai W.�. This item has been electronically signed and sealed by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. TUBULAR BUILDING SYSTEMS 30'-0"x20'-0" ENCLOSED BUILDING EXP. B JOB Nlh E- 12-18-17 SCALE, NTS 16022S/17300S . 7 DWG6 NO SK-3 o 4 SECURE WITH - (4) K12-14,3/4' y SDF'S (EACH END) 1 TS BOW D Tt:R y 3� N❑ SCREWS — REOUIRED IN_ BOW END �y�fLl p ,F�_ R•.. 3-12 .—TS DOUBLE COLUMN t 3-12 je —MINIMUM 6' LONG, CONNECTOR SLEEVE MINIMUM 15 GA", 3/16 SECURE WITH "-18 GA U-CHANNEL BRACE SLEEVE TO q12-14x3/4' S➢F'S DF' BASE RAIL "3.16 •S _ s. MINIMUM 6' LONG, MNIMUM 15 GA, TS NIPPLE SECURE ¢ C IS CONTINUOUS BOW RAFTER AND POST TO NIPPLE ) BASE RAIL WITH (4) 412-14.3/4' SDF'S 3-12 BOX EAVE RAFTER COLUMN CONNECTION DETAIL 1 FOR HEIGHTS W-0' < TO S 16'-0' N IB GA U-CHANNEL BRACE FASTENED TO THE COLUMN AND RGOF BEAM, WITH (4) N12-14r3/4' C AT EACH 2 1/2' END (B PER BRACE) BRACE SECTION SCALE NTS MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. :TM1, UOPYBE, OR OTFERVM USE OF NO ANY i7i119KElEHT TiEREW1311 MAY RAFTER COLUMN/BASE RAIL 2 CONNECTION DETAIL SCALE: NTS No 57170 er z � 5a STATE OF • 1/ ` a P'�=% O N Ai W.�. This item has been electronically signed and sealed by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. TUBULAR BUILDING SYSTEMS 30'-0"x20'-0" ENCLOSED BUILDING EXP. B J1IBND Er 12-18-17 SCALE, NTS SA 11)wCs. ND SK-3 ,, 4 SECURE WITH (4) #12-14x3/4' '•. SDF'S (EACH END) J�ty TS BOW RA r-rEG—�� - ti 31 . NO SCREWS— L ED IN BOW E BOW N➢ I Js- H I• I18 GA U-CHANNEL BRACE - MINIMUM 6- LONG, MINIMUM 15 GA, J TS NIPPLE SECURE BOW RAFTER AND POST TO NIPPLE WITH (4) #12-14.3/4' SDF'S I — TS COLUMN 3 3 x � —TS 2 1/4',2 1/4-14 GA n in REINFORCING G'-O' LONG (HW) AND 5'-0' LONG (LW) SECURE WITH (10) #12-14,�3/4 SDF'S � JIII BOX EAVE RAFTER COLUMN CONNECTION DETAIL i IA FOR HEIGHTS 10'-0- < TO � 14'-0' SCALE �TS COLUMN MINIMUM 6' LONG, SLEEVE T❑ _ - f CONNECTOR SLEEVE EASE RAIL 3/16 MINIMUM 15 GA. SECURE WITH (4) #12-14.3/4' SDF'S ��TS CONTINUCUS EASE RAIL RAFTER COLUMN/BASE RAIL 2 CONNECTION DETAIL SCALE NTS MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. TS BOW PA qP-- NO SCREWS— REQUIRED IN BOW END .JS r =t1:L Ft WITH (4) R12-14.3/4' _ SDF'S (EACH END) 1 i Ir I —18 GA U-CHANNEL BRACE .I ' MINIMUM 6' LONG,— M N MUM 15 GA, TS NIPPLE SECURE BOW RAFTER AND POST TO NIPPLE WITH (4) #12-14x3/4' SDF'S �I BOX EAVE RAFTER COLUMN CONNECTION DETAIL B FOR HEIGHTS < 10'-0' l SCALE NTS — i F� '18 GA U-CHANNEL BRACE FASTENED T❑ THE COLUMNF' AND ROOF BEAM, WITH (4) #12-14x3/4' S D S AT EACH END (B PER BRACE) BRACE SECTION. SCALE NTS ````,-jNs 11S11 Un "t", No 57170 'n • e1 STATE OF j0 •. A" '0�1,5,,O N A'11111` 'la � This item has been electronically signed and sealed by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. TUBULAR BUILDING SYSTEMS 30'-0"x20'-0" ENCLOSED BUILDING EXP. B .AB M - 9-17 SCALE, NTS 160EE3/17a 9B DWa ND SK-3 EW 4 BASE RAIL ANCHORAGE OPTIONS FOR LOW AND HIGH WIND SPEED — VWF OR FIBERGLASS INSTALL I/2'x6 3/4' EXPANSION FIBERS ANCHOR THROUGH BASE RAIL 2' WASHERS - - WITHIN 6' OF EACH POST 5/8' DIAMETER HOLE VARIES TOP OF ASPHALT ..—DRILL THROUGH THE BASE RAIL AND PAVEMENT OR GROUND SURFACE SECUP.E TO ANCHOR EYE I/2' DIAMETER THROUGH WITH BOLT fr-T —1 j�I I, IE IT � I I I1 I, I = III -_ ., gRFFa I- III_ IS 1.1-_i - --1 III MINIMUM 3 Ifq-- r EMBP DMENT(TY=y. *' —j BASE RAIL Y MONOLITHIC CONCRETE FOOTING <3000 PSI MIN) REINFORCED HELIX EYE •+ -- — - WITH (2) #4's CONTINUOUS CONCRETE M❑NOLITHIC SLAB BASE RAIL ANCHORAGE 1 SCALE NTS (MINIMUM ANCHOR EDGE DISTANCE IS 4') � COORDINATE WITH LOCAL CODES/URD GENERAL NOTES CONCRETE, CONCRETE SHALL HAVE A MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF 3,000 PSI AT 28 DAYS. COVER OVER REINF❑RCING STEEL, FOR FOUNDATIONS, MINIMUM CONCRETE COVER OVER REINFORCING BARS SHALL BE PER ACI-318: 3 INCHES IN FOUNDATIONS WHERE THE CONCRETE IS CAST AGAINST AND PERMANENTLY IN CONTACT WITH THE EARTH OR EXPOSED TO THE EARTH OR WEATHER, AND 1 1/2 INCHES ELSEWHERE REINFORCING STEEL, THE TURNDOWN REINFORCING STEEL SHALL BE ASTM A615 GRADE G THE SLAB REINFORCEMENT SHALL BE WELDED WIRE FABRIC MEETING ASTM A185 OR FIBERGLASS FIBER REINFORCEMENT REINFORCEMENT MAY BE BENT IN THE SHOP OR THE FIELD PROVIDED, 1, REINFORCEMENT IS BENT COLD, 2 THE DIAMETER OF THE BEND, MEASURED ON THE INSIDE OF THE BAR, IS NOT LESS THAN SIX -BAR DIAMETERS 3 REINFORCEMENT PARTIALLY EMBEDDED IN CONCRETE SHALL NOT BE FIELD BENT, HELIX ANCHOR NOTES, 1 FOR VERY DENSE AND/UP. CEMENTED SANDS, COARSE GRAVEL AND COBBLES, CALICHE, PRELUADED SILTS AND CLAYS USE MINIMUM (2) 4' HELICES WITH MINIMUM 30 INCH EMBEDMENT 2 FOR CORAL USE MINIMUM (2; 4' HELICES WITH MINIMUM 3C INCH EMBEDMENT. 3 FUR MEDIUM DENSE COARSE SANDS, SANDY GRAVELS, VERY STIFF SILTS, AND CLAYS USE MINIMUM (2; 4' HELICES WITH MINIMUM 3C INCH EMBEDMENT 4 FUR LOOSE TO MEDIUM DENSE SANDS, FIRM TO STIFF CLAYS AND SILTS ALLUVIAL FILL USE MINIMUM (2; 6' HELICES WITH MINIMUM 5C INCH EMBEDMENT 55 FOR VERY LOSE TO MEDIUM EENSE SANDS, FIRM TO STIFFER CLAYS AND SILTS, ALLUVIAL FILL USE MINIMUM (2: 8' HELICES WITH MINIMUM 6C INCH EMBEDMENT MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. is TM 3 B GROUND BASE HELIX ANCHORAGE SCALE NTS (CAN BE USED FOR ASPHALT) '�NE S H MOO,,,, IV No 57170 • • tr ► ��•• STATE OF 'JJ: j 0 %OR A Q: •••��% This item has been electronically signed and sealed by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. TUBULAR BUILDING SYSTEMS 30'-0"x20'-0" ENCLOSED BUILDING EXP. B JOB ID El 12-1e- 17300S 9A VG. M SK-3 EW 4 OPTIONAL FOUNDATION ANCHORAGE FOR LOW & HIGH WIND SPEED —INSTALL IGH ANCHOR INSTALL 1/2'0 ASE RRI ROD THROUGH BASE RAIL WWF UR ROD THROUGH BASE RAIL WITHIN 6' D EACH FIBERGLASS WITHIN 6' D EACH WWF OP. FIBERGLASS POST (SEE DETAIL 'C') FIBERS POST (SEE DETAIL 'C') FIBERS (T'fP) � (TYP) 1 1/2' i IIII GRADE MINIMUM 0,'_- EMBEDMENT - (TYP) I — • I I I�- �. MONOLITHIC CONCRETE FOOTING (3000 PSI MIN) REINFORCED WITH (2) N4's CONTINUOUS - CONCRETE M❑NOLITHIC SLAB IA BASE RAIL ANCHORAGE SCALE NTS (MINIMUM ANCHOR EDGE DISTANCE IS 1 1/2') COORDINATE WITH LOCAL CODES/ORD GENERAL NOTES CONCRETEi CONCRETE SHALL HAVE A MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF 3,000 PSI AT 28 DAYS, COVER OVER REINFORCING STEELi FOR FOUNDATIONS, MINIMUM CONCRETE COVER OVER REINFORCING BARS SHALL BE PER ACI-318 3 INCHES IN FOUNDATIONS WHERE THE CONCRETE IS CAST AGAINST AND PERMANENTLY IN CONTACT WITH THE EARTH OR EXPOSED TO THE EARTH OR WEATHER, AND 1 112 INCHES ELSEWHERE REINFORCING STEEL, THE TURNDOWN REINFORCING STEEL SHALL BE ASTM A615 GRADE 60. THE SLAB REINFORCEMENT SHALL BE WELDED WIRE FABRIC MEETING ASTM A185 OR FIBERGLASS FIBER REINFORCEMENT REINFORCEMENT MAY BE BENT IN THE SHOP OR THE FIELD PROVIDEDi 1 REINFORCEMENT IS BENT COLD 2. THE DIAMETER OF THE BEND, MEASURED ON THE INSIDE OF THE BAR IS NOT LESS THAN SIX -BAR EIAMETERS 3 REINFORCEMENT PARTIALLY EMBE➢LED IN CONCRETE SHALL NOT BE FIELD BENT, 2'm 436 READED C T/CONCRETE HEX NUT ANCHOR ROD THROUGH BASE IC RAIL N DETAIL MOORS AND ASSOCIATES ENGINEERING AND CONSULTING, INC. om I —�I j � f MINIMUM • — .. EMBEDMENT a -I (TYP) i _ r MONOLITHIC CONCRETE FOOTING' J f (3000 PSI MIN) REINFORCED WITH (2) 04's CONTINUOUS y CONCRETE MON❑LITHIC SLAB �B BASE RAIL ANCHORAGE - SCALE, NTS (MINIMUM ANCHOR EDGE DISTANCE IS 1 1/2') w COORDINATE WITH LOCAL CODES/OR➢, No 57170 �t'z STATE OF ' 'JJ ` ;0% •�� R Op This item has been electronically signed and sealed by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. TUBULAR BUILDING SYSTEMS 30'-0"x20'-0" ENCLOSED BUILDING EXP. B J11B ND EI 12-18-17 SCALD NTS 160 9B DW& NOI SK-3 EVa 4 BOX EAVE RAFTER END WALL AND SIDE WALL OPENINGS SEE NOTES (SHEET 3) TYPICAL BOX EAVE RAFTER END WALL FRAMING SECTION SCALE NTS .H 1� SEE NOTES (SHEET 3) OR MAX IMUM TYPICAL BOX EAVE RAFTER END WALL OPENINGS FRAMING SECTI❑N SCALE NITS SEE NOTES (SHEET 3) BOX ` EAVE RAFTER/COLUMN FUR MAXIMUM ASSEMBLY SPACING . OPENING FOP ROLL -UP .. DOORWITH HEADER - OPENING SWINGING 'P DOORffWINDOW OPENING FOR WINDOW WITH HEADER AND RAIL (ALSO o- MAXIMUM l2 Ir_I2_ WITH"ER APPLICABLE TO CND WALLS) TYPICAL BOX EAVE RAFTER SIDE WALL ❑PENINGS FRAMING SECTION SCALE NTS MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. CINSULT1M nK U MffHD = 7M 110MO R IS S7R=MY PI 1E su3j T M LEGAL ACTIDi FOR DOOR Ae 1 S. rMOO,,,' No 57170 rr �� •• STATE OF ' IJ/ ` .O•• w. Si81 N AL rriirll This item has been electronically signed and sealed by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. TUBULAR BUILDING SYSTEMS 30'-0"x20'-0" ENCLOSED BUILDING EXP. B JOB M Er — B-17 SCALEs NTS 16022S/17 S . 10 DVQ M SK-3 EVr 4 BOW RAFTER END WALL AND SIDE WALL OPENINGS SEE NOTES i (SHEET 3) TYPICAL BOX EAVE RAFTER END WALL FRAMING SECTION SCALE NTS SEE NOTES (SHEET 3) FOR MAXIMUM EAVE RAFTER/COLUMN ASSEMBLY SPAt3HG 72 v ' Y e 1 'FN[NG FOR ROLL -UP ULL C�.LCR H1.FOR -0. MA?Itm N �-- OPENING !� WITHI HEADER AND WINDOW SWINGING DOOP. .- WINDOW RAIL (ALSO WITH APPLICDLE TO END 7 WALLS) TYPICAL BOX EAVE RAFTER SIDE WALL OPENINGS FRAMING SECTION SCALE NTS SEE NOTES (SHEET 3) FOR MAXIMU .Pnr,146 ram, 77 I +, tu. OPENING FOR i ROLL -UP 77 _ SWINGING DOOR. WITH - t _le TYPICAL BOX EAVE RAFTER END WALL OPENINGS FRAMING SECTION SCALE NTS MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC BYr PBH `�NE S MO `O',', No 57170 :xz -:53' STATE OF ' I/ ID AIN .ssA' This item has been electronically signed and sealed by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. TUBULAR BUILDING SYSTEMS 30'-0"x20'-0" ENCLOSED BUILDING EXP B AB ND THLS DOCl/ETR IS STRICTLY P K SULECT TO LEGAL ACTBri .. [IDYG ND SK-3�E V.I 4ND SK-3�E V., 4 BOW AND BOX EAVE RAFTER WALL OPENING DETAILS TS RAr`rCf?- 2',2'x2' 16 GA ANGLE CLIP SECURE TO COLUMN AND RAFTER WITH #12-14:<3/4' SDF'S 2 ON 70P AND 2 ON SIDE —TS EJD COLUMN END COLUMN/RAFTER CONNECTI❑N DETAIL NIPPLE TO 3/16 BASE RAIL 3/16 IS COLUMN (CORNER) MINIMUM 6' LONG, MINIMUM 15 GA, IS NIPPLE SECURE WITH (4) #12-14x3/4' SDF'S 2'x2'x2' 16 GA CLIP ANGLE SECURE TO RAFTER COLUMN AND BASE RAIL W/(4) 412-14,3/4. SDF'S - I IS CONTINUOUS BASE RAIL END COLUMN/BASE RAIL CONNECTION DETAIL . TRUSSED RAFTER CHORD, OR HEADER 3-12 3/16 NIPPLE TO 4— — 3/16 _ HEADER 3 -12 ' 16 GA ANGLE CLIP SECURE TO COLUMN _ OR DOOR WINDOW (EACH SIDE) AND RAFTER CHORD/RAIL FRAME POST WITH #]2-14r3/4' SDF'S 2 ON BOTTOM AND 2 ON SIDE kipa UM 6' LONG, TS HEADER, BASE NOTE AT ROLL -UP DOOR OPENINGS, POST SHOULD i _ MINIMUM l5 GA, TS NIPPLE SECURE EACH WITH (4) q12-14 x3/4' RAIL, 0R WINDOW BE FLUSH WITH RAIL _�'• SDF'S RAIL - END CLIP POST TO a �„7 RAIL ONLY ON SIDE TS COLUMN OPPOSITE THE OPENING ,.•. COLUMN TO HEADER, .-- DOUBLE HEADER/COLUMN BASE RAIL, OR CONNECTION DETAIL 8 WINDOW RAIL _I , NTS 7 CONNECTION DETAIL TS COLUMN 11'\ MINIMUM 6' LUNG, NIPPLE II, MINIMUM 15 GA TS BASE RAIL ,J�16 'r NIPPLE SECURE EACH • WITH 14; #12-14x3/4' SDF'S `"' CCNTINUOUS BASE FAIL r--r- — COLUMN/BASE RAIL CONNECTI❑N DETAIL 1Q MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. THIS MOMMU M TIE PRMPERTY IF HOOK Alm ASSIiC M EPMU t M MM =S&M& 7K UWJ111011 D REPRLmUC11i CPYM OR Oi1mmx un ♦F n= DOCU Dff M S RWMY PRIM NO MY VfMIMM TFfT1 M NAY X SIMJECT M LEGAL ACT= —IS COLUMN �T OR END COLUMN 16 GA ANGLE r CLIP SECURE TO COLUMN AND EITHER TOP OF HEADER, OR BOTTOM OF WINDOW RAIL WITH #12-14.3/4' SDF'S r �1 ' TS HEADER OR WINDOW RAIL HEADER OR WINDOW RAIL TO COLUMN CONNECTION DETAIL 6 —TS COLUMN NIPPLE i0 3/16 HEADER. .-- MINIMUM 6' LONG, I MINIMUM IS GA, TS NPPLE SECURE I WITH (4) #]2-14x3/4' SDF'S 1� i 3-12 DOUBLE HEADER COLUMN/DOUBLE HEADER 9 CONNECTION DETAIL ,�Ns 1 lSl . UOO',', I No 57170 :e': STATE OF ••. A" .�� FS • p R -'1Sj0NA'11111` E 0 This item has been electronically signed and sealed by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. TUBULAR BUILDING SYSTEMS 30'-0"x20'-0" ENCLOSED BUILDING EXP. B JOB ND Ea 18-18-17 SCALE, NTS IU&MI7300S 1E DVG6 NOI SK-3 V.I 4 BOX EAVE RAFTER LEAN-TO OPTIONS KUUh LXILNSIUN MAIN STRUCTURE STANDARD 0 PTD7N LEAN-TO OPTION TYPICAL BOX EAVE RAFTER LEAN—TO OPTIONS FRAMING SECTION <BOTH OPTIONS SHOWN) SCALE NTS MAXIMUM WIDTH OF SINGLE MEMBER RAFTER LEAN-TO IS 16'-0' TS BGX EAVE RAFTER—, 1 - NIPPLE Ili C'•2'-[' 16 GA ANGLE CLIP RAFTER 3/16 12' LONG TS 15 t3A — ,' =� ,%41li. WITH `.r - l '" SECURERAFTER TU COLUMN AND A/ RAFTER WITH #12-14x3/4' J SDF'S 2 ON TOP AND 2 ON NIPPLE SECURE COLUMN TH NIPPLE - (4) #12-14)3/4' SDF'S END) / BOTTOM I WITH (4) #12-14x3/4' SDF'S - .__ (EACH W —TS RAFTER GA U-CHANNEL BRACE - '-- 1 EXTENSION yJ - RAFTER MINIMUM 6' i--or[c,—' ,■ MINIMUM 15 6A, TS NIPPLE. SECURE LEAN—TO RAFTER TO RAFTER COLUMN TO NIPPLE WITH (4)a12-14.3/4• ,nF•s COLUMN CONNECTION DETAIL TS CULHMP.— . •'� SIDE EXTENSI❑N AS. RAFTER/COLUMN DETAIL M00 No 57170 :1 ' STATE OF ' 44/` '"�\ 4 0 N A` �� ;•�• This item has been electronically signed and sealed by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. MOORS AND ASSOCIATES BRAWN BYr LT TUBULAR BUILDING SYSTEMS ENGINEERING AND CONSULTING, INC. CHECKED BY, per{ 30'-0"x20'-0" ENCLOSED BUILDING EXP. B JOB NO T►I S DOCUH W IS THE STY OF ImE ATM ASSOCIATES ENGDORM AND PROJECT MM WSM DATE, 12-18-17 SCALE, NTS 1 COlSUI.TDNG THE IRMUTH OREM REPROlWrMK, COPYM OR OTHERWISE USE OF THIS 11111CIl1E)iT IS STRDCTLY PRUNIUM NO ANY DFRDKMENT THEREUPON MAY 1E SIA.ECT TO LEGAL ACTDx CLIENT• TBS SHT. 13 DVG, ND SK-3 4 BOW RAFTER LEAN-TO OPTIONS TYPICAL BOW RAFTER LEAN-TO OPTIONS FRAMING SECTION (BOTH ❑PTIONS SHOWN) SCALE NTS MAXIMUM WIDTH OF SINGLE MEMBER RAFTER LEAN—TO IS 16'-0" SECURE WITH (D) tt1\ SDF'S (EACH END) (EA H EN IS BOW-- 12 NO SCREWS---- 3 REQUIRED IN - BOW END , • �� 4. s YM? s r' I I •I 2'.2',2' lE GA A.!,;LZ--�. AND SECURE T❑ COLUMN AND RAFTER WITH �;8 GA, U-CHANNEL PRACE N12-14.3/4' SDF'S 2 ON TGP AND 2 ❑N BOTTOM TSB-E.F'IiF� - �. _ f —TS COLUMN 13 SIDE EXTENSION RAFTER/COLUMN DETAIL SCALE NTS MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. MS =Xl1E7iI IS TI£ PROMTY IF MW NO ASSOCIATES EN Cw;LLTDII•i TFE 11HAUT}<1 = RE7Rl'IDu6T>Q1, cOPymu oR OTN T1a$ DOCL"DrT IS STRICTLY FF0fIR TED APO WY DFRDIGDENT "111111111j1 .�',P4NAe S. MOO �a ••��ENs• •:4F•� .' • No 57170 r• •.ram S :1 ' STATE OF This item has been electronically signed and sealed by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. TUBULAR BUILDING SYSTEMS 30'-0"x20'-0" ENCLOSED BUILDING EXP. B 14 JDNG M SK-3 BOX EAVE RAFTER VERTICAL ROOF/SIDING OPTION TYPICAL SIDE ELEVATI❑N VERTICAL R❑❑F/SIDING ❑PTI❑N SCALE NITS —1 GAUGE FURRING CHANNEL ROOF PANEL ATTACHMENT MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. 0M 3MSE 113E ff TFEAEIFM MY 29 GA. GALVANIZED METAL FOOPj PANELS FASTENED TO PURLINS TYPICAL SECTI❑N VERTICAL R❑❑F/SIDING ❑PTI❑N SEE NOTES = d GAUGE FURRING CHANNEL SPACED (SHEET 3) NOT MORE THAN 4'-0' OC AND FASTENED FOR MAXIMUM TO EACH THAN WITH (2) H12-14x 3/4' TYPICAL FRAMING SECTI❑N VERTICAL R❑❑F/SIDING ❑PTI❑N SCALE; NTS S„Moo I oo No 57170 :t'- STATE OF ��i FS • O R 0 N A� This item has been electronically signed and sealed by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. TUBULAR BUILDING SYSTEMS 30'-0"x20'-0" ENCLOSED BUILDING EXP. B Jos NO 0 12— —17 WALD NTS 16022 / 7 15 DWS ND SK-3 V.1 4 OPTIONAL DOOR HEADER —2 1/2x2 112-14 GA. (TYP ) —2 1/2<2 112-14 1'-81 ❑.0 (TYP.) '/16 � - TYP l6 HEADER DETAIL FOR DOOR OPENINGS 12'-0' < LENGTH S 15'-0' MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. TM DOCU Off IS STRICTLY P X SUBJECT TO LEGAL ACTnL 2 1/2x2 1/2-14 G( (TYP) 3/16 - TYP 3/16 HEADER DETAIL FOR DOOR OPENINGS LENGTH S 12'-0' SCALE NTS NE 1 S„A40 No 57170 �13 STATE OF ' IJJ ` P'�=%% /lS,O N All � E�.�. This item has been electronically signed and sealed by Wayne S. Moore, PE. using a Digital Signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. TUBULAR BUILDING SYSTEMS 30'-0"x20'-0" ENCLOSED BUILDING EXP. B .AB NO Er 12-18-17 SCALE, NTS 16022S/17300S 16 VG. ND SK-3 EV.r 4