Loading...
HomeMy WebLinkAboutPA FL17420-R4, underlaymmentsai �lr�'ih , k rf i r4S �.h "ilk' 7 ii9.4 kn:d���� dNiaz 7d -� ry + w ';'i ✓< N mr ✓� IT '.�`r I �'..' r 7 Ilr iP M. N+ 1 r,J1 m.Wou .eilul.!•+11�R' llw $d'.VAe ,..Yw'p BCI5 Home Log In User Registration Hot Topics Submit Surcharge Scats & Facts Publications Contact us ! BCIs site Map � Links Search bO dr (A Product Approval USER: Pu61fc User Product Aoaroval Menu 7 Produrt or Aooli cation Search a AmNication List a ApPOCation Detalf FL # FL17420-R4 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo, OH 43559 (740)404-7629 greg.keeler@owenscorning,com Authorized Signature Greg Keeler greg.keeler@owensccrning.com Technical Representative Address/Phone/Email Quality Assurance Representative Add ress/Phone/Email category Roofing Subcategory underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a licensed Florida Professional Engineer Fvaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Zachary R. Priest the Evaluation Report Florida License PE-74021 Quality Assurance Entity Intertek Testing Services NA, Inc, - QA Entity Quality Assurance Contract Expiration Date 12/31/2020 Validated By Locke Bowden P.E. Validation Checklist - Hardeopy Received Certificate of Independence FL1742 —B4 _= OC I40 4.4 2Q17 FBC Eva[ Re ort P rm i al.pdf Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code 1507.1 A Date Submitted 09/30/2017 Date Validated 1010312017 Date Pending FBC Approval 10/04/2017 Date Approved 12/12/2017 Summary of Products r FL # Model, Number or Name Description 17420.1 Pr A mor Synthetic underlayment for use with asphalt shingles in steep slope roofing Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes FL174 0 RA II QCR140Q4,4 2017 FBC Ev pgrt_ProArmar final.gdf Impact Resistant: N/A Veribed By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports R17420 R4_A QCR14004.4 2Q17 FI3 Eval RePart ProArmor final.odf Created by Independent Third Party: Yes back r4ext Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone,a50-487-182 The State of Florida is an AAjFEO employer, Sgpy119ht 2007-2013 State of Florida, :: Privacy Statement :: AcCCSSiUflial Stateme :: Refund Statement Under Florida law, email addresses are puhllc records. if you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditl0nai mail. if you have any questions, please contact 850.487.1395. "Pursuant to Section 455.275(1), Florlda Statutes, effective Octnher 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for offfcial communication with the licensee. However email addresses are public record. if you do not wlsh to supply a personal address, please provide the Department with an email address which can be made available to the public 70 determine if you are a licensee under Chapter 455, FS-, please dick here Product Approval Accepts: ®® M Credit Card Safe Certificate ofAuthorizationion bur Drive l 17520 Edinburgh Drive i CREEK Tampa, FL 33647 TECHNICAL SERVICES, LLB (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE fir" EDITION (2017) Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued September30, 2017 1 Owens Corning Parkway Toledo, OH 43657 (800)438-7465 www.owenscarn rig.com Quality Assurance: Intertek Testing Services NA, Inc. (QUA1673) SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 1507.1.1 Properties: Physical properties REFERENCES Entrty RRe ert No. Standard Year Intertek Testing Services NA Ltd. (TST1509) 102389161 COQ-002A AC 188 2012 Intertek Testing Services NA Ltd. (TST1509) 10238916100Q-003b ASTM E 108 2011 Intertek Testing Services NA Ltd. (rST1509) 102389161 COQ-004 ASTM D 226 2009 PRI Construction Materials Technologies (TST5878) OCR-259-02-01 ASTM D 1970 2015a PRODUCT DESCRIPTION AND APPLICATION ProArmor'" A mechanically attached, synthetic underlayment consisting of a woven polypropylene base with a non -woven pofypropylene laminate on the topside of the underlayment, and a coating on the back side (nominal weight = 2-15 Ib1100f ). The underlayment shall be used an alternative to ASTM D 226, Type it roofing underlayments and has demonstrated a minimum tear strength of 20 pounds when tested in accordance with ASTM D 1970. The product is supplied in 9.2-sq rolls with nominal dimensions of 4-ft x 250.5-ft. Unless otherwise noted, the following application details shall be followed for New and Existing construction. See manufacturer's installation instructions for further detail. Roof Deck: The roof deck shall be constructed of closely fitted wood sheathing for new or existing construction. Plywood deck shall be installed in accordance with FBC requirements. Roof decks shall have no more than118" gap at abutting joints. Attachment method: Underlayment shall be attached in accordance with the FBC Table 1507.1.1 and manufacturer's installation instructions. Allowable roof coverings: Mechanically attached roof systems as prescribed in FBC Section 1507.1.1. OCR14004.4 FL17420-R4 Page 1 of 2 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services_ LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor Imply warranty, installation, recommended use, or other product attributes that are not „AA_o ,+ A.-m 'y CREEK TECHNICAL SERVICES, LLC LIMITATIONS OWENS CORNING ROCFING AND ASPHALT LLC ProArmor7N1 1) This evaluation report is not for use in the HVHZ. 2) Fire Classification is not within the scope of this evaluation. 3) Wind uplift resistance in not within scope of this evaluation. 4) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 6) Roof slope limitations shall be in accordance with FBC requirements. 7) The underlayment may be used as described in other current FBC product approval documents. 8) Roof coverings shall not be adhered directly to the underlayment. Roof coverings shall be mechanically fastened through the underlayment to the roof deck. 9) The underlayment shall not be installed over existing roof coverings. 10) All underlayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped in success courses installed up the deck in a manner that effectively sheds water from the deck. End laps shall be staggered between courses in accordance with the manufacturer's application instructions. 11) The underlayment shall not be exposed on the roof deck for longer than 30 days. 12) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 (320-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code 6 Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer_ R. r .`,�P ,•' �� G•E N Sly'''• No 74021 yk ) STAT E Q F � �ONAt fIIIIII111"k� CERTIFICATION OF INDEPENDENCE 2017.09.30 111h 15:21:14 -o41aal Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9541 CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEKTechnical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a fnancial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT OCR14CO4.4 FL17420-134 Page 2 of 2 This evaluation report is provided for State of Fiord. product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, Installation, recommended use, or other product attributes that are not c noniFirell. n.-f.-lre ccorJ herein