Loading...
HomeMy WebLinkAboutPA FL10758-R7BCIS Home Lag In User Registration Hot7epics Suhrnit Surcharge Srats & Facts Publications Contact US =S Site Map Links I Search Approval ( bProduct or USER; Public user Product AnprnvaI McMM > Prod uct Qr 8p licatio earth 7 Ajjlication Lit > Applicattoa Detail FL # FL10758-R7 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo, OH 43659 (740)404-7829 grcg.keeler@owenscorning.com Authorized Signature Greg Keeler greg.keeler@owenscorn i ng-corn Technical Representative Greg Keeler Address/Phone/Email 2790 Columbus Road Grenville, OH 43023 (740) 321-6345 greg.keeler@owenscorning.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Roofing Accessories that are an Integral Part of the Roornng system Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Zachary R. Priest the Evaluation Report Florida License PE-74021 Quality Assurance Entity UL LLC Quallty Assurance Contract Expiration Date 10/13/2020 Validated By Locke Bowden P.E. . Validation Checklist - Hardcopy Received Certificate of Independence FL1075B R7 COT OCR14003.3 2017 F13C Evaluation Re ort Qwens or in V nts final.pdf Referenced Standard and Year (of Standard) https:,ywww.floridabuilding.org/prjpr_app_dtl_aspx?param=wGEVXQwtDgvidAvlleOYO%2bC3zFtFydggNkhwZWZ.zJrLipAl5CIMPWIH{d%3d%3d Page 1 of 3 Equivalence of Product Standards Certified By Sections from the Code 1708.2 Product Approval Method Method 2 Option B Date Submitted 09/30I2017 Date Validated 10/04/2017 Date Pending FBC Approval 10/08/2017 Date Approved 12/12/2017 Summary of Products F _ ; FL V Model, Number or Name Description 10758.1 1 VentSure 4-Foot Strip Heat and Moisture Ridge Vents i Copolymer plastic low profile attic ridge vents for installation in shingle roof systems Limits of Use Installation Instructions Approved for use in HVHZ: No LJQ75$_R7_II OCR14003.3 2017 FBC Evaluation Rep r1 Qwg is Corning_Vents final.pd Approved for use outside HVHZ: Yes Impact Resistant: NIA Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to evaluation report Evaluation Reports FL10758-_F,7 AE OCR14003.3 2017 FSC Evaluation Reg.Qrj gwen� QpiniLc Vents final.pdf Created by Independent Third Party: Yes 10758.2 VentSure Low Profile Slant Back Galvanized metal roof vent �� w Roof Vent With Exterior Louver Limits of Use Installation Instructiions Approved for use in HVHZ: No FL10758 R7 II GCR14003.3 2417 FBC 1 valuation Report Approved for use outside HVHZ: Yes Owens Corningyent� finaEgdf Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: NIA Created by Independent Third Party: Yes I Other: Refer to evaluation report. Evaluation Reports FL10758 R7 AE OCR14003.3 2017 FBC Evaluation Report Owens Corning Vents final.odf Created by Independent Third Party: Yes 10758.3 VentSure Rigid Roll Ridge Vent Ridge Ventilation System Limits of Use Installation Instructions Approved for use in HVHZ: No FL10758 R7 II OCR14003.3 2017 FBC Evaluation P&p=l Qwens Corning Vents final.pdf Approved for use outside HVHZ: Yes Impact Resistant: NIA Verified By: Zachary R. Priest 74021 Design Pressure: NIA Created by Independent Third Party: Yes Other: Refer to evaluation report. Evaluation Reports FL10758 PZ_6E_QCR14003,3 2017 FBC Evaluation Repr Owens Corning Vents final.pdf Created by Independent Third Party: Yes Back tdext Cc ntact Us:: 2601 Me I Stone Road, Tallahassee FL 32399 Phone: 851).487-1824 The State of Florida is an A)VFFO employer. Coovriaht 2007-2013 State of Florida. :: Lv ment :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. if you do not want your e-mail address released in response to a publlc-records request, do not send electronic mail to ihls entity. Instead, contact the office by phone or by traditional mail. It you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, E5, must provide the Department with an email addre55 if they have one. The @mails provided may be used for ofFidal tomrnunication with the licensee. however email addresses are public record. If you do not wish to supply a personal address, please pravide the Department with an emall address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please dii:k here . https://www.flcridabuilding.org/pr/pr_Lipp_dtl.aspx?param=wGEVXQwtDgvldAvlteOYp%2bC3zrtrydggNkhwZWZzJrupAl5clMPWHQ%3d%3d Page 2 of 3 P rod o ct A pp rova l Accepts: R&OU ll�P ;E Greii Gard Safe https:/Jwww.floridabuilding.org/pr/pr_app_dtt.aspx?pararn=wGEVXQwtDgvlclAvIteCYO%2bC3zFtrydgONkhwZVVZzJrupAl5C]MPWHQ%3d%3d Page 3 of 3 No. Certificate of Authorization Edinburgh 2gh Dr CREEK17520 Edinburgh Dr Tampa, FL 33647 TECHNICAL SERVICES, LLC (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 6T" EDITION (2017) Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued September30, 2017 1 Owens Corning Parkway Toledo, OH 43857 (800) 438-7465 www. owe n s co rni n q. com Quality Assurance: UL LLC (QUA9625) SCOPE Category: Roofing Subcategory: Roofing Accessories that are an Integral Part of the Roofing System Code Sections: 1708.2 Properties: Roof Ventilation REFERENCES E. ntity Report No. Standard Year Architectural Testing, Inc (TST1558) 01-38660.04 TAS 100(A) 1995 Architectural Testing, Inc (TST1558) 01-38660.05 TAS 10D(A) 1995 Architectural Testing, Inc (TST1558) C1774.01-109-18 TAS 100(A) 1995 ASTM D 635 2010 ASTM D 1929 2012 ASTM D 2843 2010 PRI Construction Materials Technologies (TST5878) AVIG-00--02-01 ASTM D 635 2010 ASTM D 1929 2012 ASTM D 2843 2010 PRI Construction Materials Technologies (TST5878) AVIG-006-02-01 ASTM G 155 2005a PRI Construction Materials Technologies (TST5878) OCr-111-02-01 ASTM D 635 2010 ASTM D 1929 2012 ASTM D 2843 2010 PRI Construction Materials Technologies (TST5878) OCF-112-02-m ASTM G 155 2005a PRI Construction Materials Technologies (TST5878) OCF-116-02-01 TAS 100(A) 1995 PRI Construction Materials Technologies (TST5878) OCF-223-02-01 TAS 100(A) 1995 PRI Construction Materials Technologies (TST5878) OHI-007-02-01 TAS 100(A) 1995 OCR14003.3 FL10758-R7 Page 1 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assuranoe changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not c.wrifirellu erlrirac 4 h--m CREEK TecHNICALSERV10ES, LLC PRODUCT DESCRIPTION AND APPLICATION OWENS CORNING ROOFING AND ASPHALT LLC VentSure® Roof Ventilation VentSure�'4-Foot Strip 1-114" x 14-718" x 48" low -profile attic ridge vent consisting of a two -layer nylon - Heat and Moisture Ridge polyester composite_ Available with or without a polyester fabric moisture barrier for Vents: installation in shingle roof systems. 48" I S 14-71 8" Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing construction. Roof deck shall be designed and installed in accordarice with FBC requirements. Roof slope: Minimum 3:12 to maximum 16112 Installation Height: Maximum 66-ft Attachment Method: Cut a 2-inch opening (1-inch an each side of the ridge) centered in the deck at the ridge for ventilation. The slot shall terminate approximately 6-inches from the rake edges. Apply a 'i4-inch wide bead of ASTM D 4586 roofing cement along the entire length of the outside edges of the vent to seal the vent to the field shingles, taking care to not completely cover the weep slots in the vent. Center the vent over the opening and fasten to the deck using the 11 ga. 2'/z-inch galvanized ring shank nails (shall comply with FBC Section 1506.5) provided with the vent. Fasteners are to be installed on both sides of the vent 1, 12, 24, 36, and 47-inches from the start of each vent piece. Prepare the adjacent vent section by applying the roofing cement along the edges, snap together with fixed vent, and fasten to the deck in the same manner as the first section. Fasten the ridge shingles over the vent to the deck on the marked "shingle nail line" with two (2) minimum 11 ga. 2'J-inch galvanized ring shank roofing nails (shall comply with FBC Section 1506 5) provided with the vent or as directed by the shingle manufacturer's installation instructions. Allowable Roof Coverings: Asphalt shingles OCR14003.3 FL10758-R7 Page 2 of 5 This evaluation report Is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not cnnr;�..�I[., �.J`I.nccar! harcin RE�j OWENS CORNING ROOFING AND ASPHALT LLC 11 VentSureb Roof Ventilation TECHNICAL SERVICES, LLC Veil Low Profile 18" x 24' x 2-3116" (32" x 23" flange base) static off -ridge vent composed of ASTM Slant Back Roof Vent A653 galvanized steel (available with painted finish). Material shall conform with with Exterior Louver: FBC Section 1507.4.3_ ..T s -ire r M.• T'_3_ ?'u Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing construction. Roof deck shall be designed and installed in accordance with FBC requirements. Roof slope: Minimum 3:12 Installation Height: Maximum 33-ft Attachment Method: Cut an 11 x 11-inch hole through wood sheathing only approximately 18-inches from the ridge. Apply 114-inch thick by 3-inch wide bed of ASTM D 4586 roofing cement around inner and outer flange. Place vent directly over the hole, ensuring the vent sits flat on the roof. Fasten vent 4-inches o.c. and 1-inch from outside edge of flange with minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5), ensuring '/,inch penetration through woad deck (Minimum 18 nails per vent). Install baffle in t/.-inch bed of ASTM D 4586 roofing cement and secure with minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5) spaced 8-inches o.c. (total of (3) nails) while ensuring %-inch penetration through wood deck. Seal all nails and vent flange with ASTM ❑ 4586 roofing cement. Allowable Roof Coverings: Asphalt shingles OCR14003.3 FL10758-R7 Paae 3 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not enerifirell..—.ad— A 1 e ;e REOWENS CORNING ROOFING AND ASPHALT LLC a;CEKVentSure® Roof Ventilation s. TECHNICAL SERVICES, LLC VentSure Rigid Roll 518" x 11-114" x 20' attic ridge vent composed of high density polypropylene with a Ridge Vent: spun -bond polypropylene fabric. Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing construction. Roof deck shall be designed and installed in accordance with FBC requirements. Roof slope: Minimum 2:12 to maximum 20:12 Installation Height: Maximum 60-ft Attachment Method: Cut a 2-inch opening (1-inch on each side of the ridge) centered in the deck at the ridge for ventilation_ The slot shall terminate approximately 12-inches from the rake edges. Apply a continuous bead of polyurethane adhesive sealant along the entire length of the outside edges of the vent to seal the vent to the field shingles. Center the vent over the opening and fasten the vent 24-inches o.c. to the deck using minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5), ensuring %-inch penetration through wood deck. Fasten the ridge shingles over the vent to the deck on the marked "shingle nail line" with two (2) minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5) or as directed by the shingle manufacturer's installation instructions, ensuring %-inch penetration through wood deck. Outside edges of the shingles shall be sealed with flashing cement. Allowable Roof Coverings: Asphalt shingles LIMITATIONS 1) Fire Classification is outside the scope of this evaluation. 2) This report is not for use in the HVHZ. 3) The root deck and deck attachment shall be designed by others in accordance with the FBC. 4) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. 5) Owens Corning vents shall be installed in strict compliance with this evaluation report and the manufacturer's published installation instructions. In the event of conflict, the more restrictive installation shall be enforced. 6) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion prior to installation. 7) Installation of the roof assembly is outside the scope of this evaluation. 8) Owens Corning vents are intended to provide passive ventilation for an enclosed attic in residential construction applications. OCR14003.3 FL10758-R7 Page 4 cf 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3_ The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not enn�ifi-�Ii�� erJrlrecmmr! herein ''•r+,A CREEK OWENS CORNING ROOFINGANDASPHALT LLC VentSure® Roof Ventilation I`rh TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 60 Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. 4`tG�P�Y R. p�4fff No 74021 Q; STATE OF :U �11 N A� "t�t��. CERTIFICATION OF INDEPENDENCE 2017.09.30 15:16:17 -04'00' Zachary R. Priest, P.E. Florida Registration No. 74C21 Organization No. ANE9641 CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated: or oontrolled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest; P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT OCR14003.3 FL10758-R7 Page 5 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not