FL #
FL10758-R7
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
Archived
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo, OH 43659
(740)404-7829
grcg.keeler@owenscorning.com
Authorized Signature Greg Keeler
greg.keeler@owenscorn i ng-corn
Technical Representative Greg Keeler
Address/Phone/Email 2790 Columbus Road
Grenville, OH 43023
(740) 321-6345
greg.keeler@owenscorning.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Roofing Accessories that are an Integral Part of the Roornng system
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Zachary R. Priest
the Evaluation Report
Florida License PE-74021
Quality Assurance Entity UL LLC
Quallty Assurance Contract Expiration Date 10/13/2020
Validated By Locke Bowden P.E.
. Validation Checklist - Hardcopy Received
Certificate of Independence FL1075B R7 COT OCR14003.3 2017 F13C Evaluation Re ort Qwens
or in V nts final.pdf
Referenced Standard and Year (of Standard)
https:,ywww.floridabuilding.org/prjpr_app_dtl_aspx?param=wGEVXQwtDgvidAvlleOYO%2bC3zFtFydggNkhwZWZ.zJrLipAl5CIMPWIH{d%3d%3d Page 1 of 3
Equivalence of Product Standards
Certified By
Sections from the Code
1708.2
Product Approval Method Method 2 Option B
Date Submitted
09/30I2017
Date Validated
10/04/2017
Date Pending FBC Approval
10/08/2017
Date Approved
12/12/2017
Summary of Products
F _ ;
FL V Model, Number or Name
Description
10758.1 1 VentSure 4-Foot Strip Heat and
Moisture Ridge Vents
i
Copolymer plastic low profile attic ridge vents for installation
in shingle roof systems
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
LJQ75$_R7_II OCR14003.3 2017 FBC Evaluation Rep r1
Qwg is Corning_Vents final.pd
Approved for use outside HVHZ: Yes
Impact Resistant: NIA
Verified By: Zachary R. Priest 74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: Refer to evaluation report
Evaluation Reports
FL10758-_F,7 AE OCR14003.3 2017 FSC Evaluation Reg.Qrj
gwen� QpiniLc Vents final.pdf
Created by Independent Third Party: Yes
10758.2
VentSure Low Profile Slant Back
Galvanized metal roof vent �� w
Roof Vent With Exterior Louver
Limits of Use
Installation Instructiions
Approved for use in HVHZ: No
FL10758 R7 II GCR14003.3 2417 FBC 1 valuation Report
Approved for use outside HVHZ: Yes
Owens Corningyent� finaEgdf
Impact Resistant: N/A
Verified By: Zachary R. Priest 74021
Design Pressure: NIA
Created by Independent Third Party: Yes
I Other: Refer to evaluation report.
Evaluation Reports
FL10758 R7 AE OCR14003.3 2017 FBC Evaluation Report
Owens Corning Vents final.odf
Created by Independent Third Party: Yes
10758.3 VentSure Rigid Roll Ridge Vent
Ridge Ventilation System
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL10758 R7 II OCR14003.3 2017 FBC Evaluation P&p=l
Qwens Corning Vents final.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: NIA
Verified By: Zachary R. Priest 74021
Design Pressure: NIA
Created by Independent Third Party: Yes
Other: Refer to evaluation report.
Evaluation Reports
FL10758 PZ_6E_QCR14003,3 2017 FBC Evaluation Repr
Owens Corning Vents final.pdf
Created by Independent Third Party: Yes
Back tdext
Cc ntact Us:: 2601 Me I Stone Road, Tallahassee FL 32399 Phone: 851).487-1824
The State of Florida is an A)VFFO employer. Coovriaht 2007-2013 State of Florida. :: Lv ment :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. if you do not want your e-mail address released in response to a publlc-records request, do not send electronic
mail to ihls entity. Instead, contact the office by phone or by traditional mail. It you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, E5, must provide the Department with an email addre55 if they have
one. The @mails provided may be used for ofFidal tomrnunication with the licensee. however email addresses are public record. If you do not wish to supply a
personal address, please pravide the Department with an emall address which can be made available to the public. To determine if you are a licensee under Chapter
455, F.S., please dii:k here .
https://www.flcridabuilding.org/pr/pr_Lipp_dtl.aspx?param=wGEVXQwtDgvldAvlteOYp%2bC3zrtrydggNkhwZWZzJrupAl5clMPWHQ%3d%3d Page 2 of 3
P rod o ct A pp rova l Accepts:
R&OU ll�P ;E
Greii Gard
Safe
https:/Jwww.floridabuilding.org/pr/pr_app_dtt.aspx?pararn=wGEVXQwtDgvlclAvIteCYO%2bC3zFtrydgONkhwZVVZzJrupAl5C]MPWHQ%3d%3d Page 3 of 3
No.
Certificate of Authorization Edinburgh
2gh Dr
CREEK17520 Edinburgh Dr
Tampa, FL 33647
TECHNICAL SERVICES, LLC (813) 480-3421
EVALUATION REPORT FLORIDA BUILDING CODE, 6T" EDITION (2017)
Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued September30, 2017
1 Owens Corning Parkway
Toledo, OH 43857
(800) 438-7465
www. owe n s co rni n q. com
Quality Assurance: UL LLC (QUA9625)
SCOPE
Category: Roofing
Subcategory: Roofing Accessories that are an Integral Part of the Roofing System
Code Sections: 1708.2
Properties: Roof Ventilation
REFERENCES
E. ntity
Report No.
Standard
Year
Architectural Testing, Inc (TST1558)
01-38660.04
TAS 100(A)
1995
Architectural Testing, Inc (TST1558)
01-38660.05
TAS 10D(A)
1995
Architectural Testing, Inc (TST1558)
C1774.01-109-18
TAS 100(A)
1995
ASTM D 635
2010
ASTM D 1929
2012
ASTM D 2843
2010
PRI Construction Materials Technologies (TST5878)
AVIG-00--02-01
ASTM D 635
2010
ASTM D 1929
2012
ASTM D 2843
2010
PRI Construction Materials Technologies (TST5878)
AVIG-006-02-01
ASTM G 155
2005a
PRI Construction Materials Technologies (TST5878)
OCr-111-02-01
ASTM D 635
2010
ASTM D 1929
2012
ASTM D 2843
2010
PRI Construction Materials Technologies (TST5878)
OCF-112-02-m
ASTM G 155
2005a
PRI Construction Materials Technologies (TST5878)
OCF-116-02-01
TAS 100(A)
1995
PRI Construction Materials Technologies (TST5878)
OCF-223-02-01
TAS 100(A)
1995
PRI Construction Materials Technologies (TST5878)
OHI-007-02-01
TAS 100(A)
1995
OCR14003.3 FL10758-R7 Page 1 of 5
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assuranoe changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
c.wrifirellu erlrirac 4 h--m
CREEK
TecHNICALSERV10ES, LLC
PRODUCT DESCRIPTION AND APPLICATION
OWENS CORNING ROOFING AND ASPHALT LLC
VentSure® Roof Ventilation
VentSure�'4-Foot Strip 1-114" x 14-718" x 48" low -profile attic ridge vent consisting of a two -layer nylon -
Heat and Moisture Ridge polyester composite_ Available with or without a polyester fabric moisture barrier for
Vents: installation in shingle roof systems.
48"
I S
14-71 8"
Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing
construction. Roof deck shall be designed and installed in accordarice with FBC
requirements.
Roof slope: Minimum 3:12 to maximum 16112
Installation Height: Maximum 66-ft
Attachment Method: Cut a 2-inch opening (1-inch an each side of the ridge) centered in the deck at the
ridge for ventilation. The slot shall terminate approximately 6-inches from the rake
edges. Apply a 'i4-inch wide bead of ASTM D 4586 roofing cement along the entire
length of the outside edges of the vent to seal the vent to the field shingles, taking
care to not completely cover the weep slots in the vent. Center the vent over the
opening and fasten to the deck using the 11 ga. 2'/z-inch galvanized ring shank nails
(shall comply with FBC Section 1506.5) provided with the vent. Fasteners are to be
installed on both sides of the vent 1, 12, 24, 36, and 47-inches from the start of each
vent piece.
Prepare the adjacent vent section by applying the roofing cement along the edges,
snap together with fixed vent, and fasten to the deck in the same manner as the first
section. Fasten the ridge shingles over the vent to the deck on the marked "shingle
nail line" with two (2) minimum 11 ga. 2'J-inch galvanized ring shank roofing nails
(shall comply with FBC Section 1506 5) provided with the vent or as directed by the
shingle manufacturer's installation instructions.
Allowable Roof Coverings: Asphalt shingles
OCR14003.3 FL10758-R7 Page 2 of 5
This evaluation report Is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
cnnr;�..�I[., �.J`I.nccar! harcin
RE�j OWENS CORNING ROOFING AND ASPHALT LLC
11 VentSureb Roof Ventilation
TECHNICAL SERVICES, LLC
Veil Low Profile 18" x 24' x 2-3116" (32" x 23" flange base) static off -ridge vent composed of ASTM
Slant Back Roof Vent A653 galvanized steel (available with painted finish). Material shall conform with
with Exterior Louver: FBC Section 1507.4.3_
..T
s
-ire
r M.•
T'_3_
?'u
Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing
construction. Roof deck shall be designed and installed in accordance with FBC
requirements.
Roof slope: Minimum 3:12
Installation Height: Maximum 33-ft
Attachment Method: Cut an 11 x 11-inch hole through wood sheathing only approximately 18-inches from
the ridge. Apply 114-inch thick by 3-inch wide bed of ASTM D 4586 roofing cement
around inner and outer flange. Place vent directly over the hole, ensuring the vent
sits flat on the roof. Fasten vent 4-inches o.c. and 1-inch from outside edge of flange
with minimum 12 ga. ring shank roofing nails (shall comply with FBC Section
1506.5), ensuring '/,inch penetration through woad deck (Minimum 18 nails per
vent).
Install baffle in t/.-inch bed of ASTM D 4586 roofing cement and secure with
minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5)
spaced 8-inches o.c. (total of (3) nails) while ensuring %-inch penetration through
wood deck. Seal all nails and vent flange with ASTM ❑ 4586 roofing cement.
Allowable Roof Coverings: Asphalt shingles
OCR14003.3 FL10758-R7 Paae 3 of 5
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
enerifirell..—.ad— A 1 e ;e
REOWENS CORNING ROOFING AND ASPHALT LLC
a;CEKVentSure® Roof Ventilation
s.
TECHNICAL SERVICES, LLC
VentSure Rigid Roll 518" x 11-114" x 20' attic ridge vent composed of high density polypropylene with a
Ridge Vent: spun -bond polypropylene fabric.
Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing
construction. Roof deck shall be designed and installed in accordance with FBC
requirements.
Roof slope: Minimum 2:12 to maximum 20:12
Installation Height: Maximum 60-ft
Attachment Method: Cut a 2-inch opening (1-inch on each side of the ridge) centered in the deck at the
ridge for ventilation_ The slot shall terminate approximately 12-inches from the rake
edges. Apply a continuous bead of polyurethane adhesive sealant along the entire
length of the outside edges of the vent to seal the vent to the field shingles. Center
the vent over the opening and fasten the vent 24-inches o.c. to the deck using
minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5),
ensuring %-inch penetration through wood deck.
Fasten the ridge shingles over the vent to the deck on the marked "shingle nail line"
with two (2) minimum 12 ga. ring shank roofing nails (shall comply with FBC Section
1506.5) or as directed by the shingle manufacturer's installation instructions,
ensuring %-inch penetration through wood deck. Outside edges of the shingles shall
be sealed with flashing cement.
Allowable Roof Coverings: Asphalt shingles
LIMITATIONS
1) Fire Classification is outside the scope of this evaluation.
2) This report is not for use in the HVHZ.
3) The root deck and deck attachment shall be designed by others in accordance with the FBC.
4) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
5) Owens Corning vents shall be installed in strict compliance with this evaluation report and the
manufacturer's published installation instructions. In the event of conflict, the more restrictive installation
shall be enforced.
6) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion prior to installation.
7) Installation of the roof assembly is outside the scope of this evaluation.
8) Owens Corning vents are intended to provide passive ventilation for an enclosed attic in residential
construction applications.
OCR14003.3 FL10758-R7 Page 4 cf 5
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3_ The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
enn�ifi-�Ii�� erJrlrecmmr! herein
''•r+,A CREEK OWENS CORNING ROOFINGANDASPHALT LLC
VentSure® Roof Ventilation
I`rh
TECHNICAL SERVICES, LLC
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 60 Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
4`tG�P�Y R. p�4fff
No 74021
Q; STATE OF :U
�11 N A� "t�t��.
CERTIFICATION OF INDEPENDENCE
2017.09.30
15:16:17
-04'00'
Zachary R. Priest, P.E.
Florida Registration No. 74C21
Organization No. ANE9641
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated: or oontrolled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest; P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT