HomeMy WebLinkAboutMatthews PA LetterSeptember 11th, 2020
Steve Nutt
1559 SE South Niemeyer Circle
Port Saint Lucie, Florida 34952-3507
RE: FLORIDA COASTAL ROOFING
6505 Lakeland Blvd
Fort Pierce, FL 34951
RE: Polyglass Elastoflex SA-V and Polyflex G HP over
Dear Mr. Steve Nutt
Tri-Built Ply Base
This letter is in reply to a request from Mr. David Johnson, Chief Building Inspector for the St. Lucie
Building Department. With the approval of your local building department, or Authority Having
Jurisdiction, Polyglass takes no exception to the following installation of Polyflex G HP (4.5mm)
over a previously installed membrane on the aforementioned project:
• Ensure the existing membrane, in this case Tri-Built SA Ply Base, is clean, dry, and free of debris. -
Once existing membrane is prepared, a new ply of Elastoflex SA V is to be installed directly over the
existing base ply, and mechanically attached per local code. • Follow the Elastoflex SA V by a new
layer of Polyflex G HP (4.5mm) torch applied.
Should you have any further comments or concerns, please feel free to contact our Technical
Services Department.
Thank you for supporting Polyglass U.S.A., Inc
Sincerely,
Paul O'Connell
South Florida Technical Representative
Polyglass U.S.A. Inc.