HomeMy WebLinkAboutLetter; Requested Design LoadsWHIRLWIND
May 13, 1996
Paul Jacquin & Son Const.
7348 Commercial Circle
Fort Pierce, FL 34951
RE: Whirlwind Job No. 960299
_Aer-ex Industries
BUILDING SYSTEMS
P.O. BOX 75280 • 8234 HANSEN ROAD .
HOUSTON, TEXAS 77234.5280 713-946-7140
Gentlemen:
This letter is to certify that the above referenced building has been designed
to sustain no less than the requested design loads, as listed on the order
documents, applied per the 1994 Standard Building Code, specifically as follows:
Collateral Load - 3 psf
Roof Live Load - 20 psf
Frame Live Load - 12 psf
Ground Snow Load - 0 psf Importance - N/A Exposure - N/A
Wind Load - 110 mph Importance - 1.0 Exposure - N/A
Wind design is based on a fully enclosed building. All accessories provided by
others must be designed to sustain no less than the same wind criteria as the
building.
Seismic Hazard Exposure Group— I
Peak Velocity - related Acceleration .05 Peak Acceleration - .05
Seismic Performance Category B Soil Profile -.2.0
Framing Direction Lateral longitudinal
Structural. System Ordinary Moment Braced Frame
Response Modification Factor 4.5 4.0
Deflection A'mplication Factor 4.0 4.5
Analysis Procedure Equivalent Lateral Force
Other Loads - One - 5 Ton Electric Underhung Crane with the following
data: Hoist Weight - 4,400 lbs.
Bridge Weight - 7,530 lbs.
Wheel Load 12,500 lbs (without impact)
Wheel Base - 6'-5
Design is in accordance with the AISI Specification for the Design of Cold -Formed
Steel Structural Members, August 19, 1986 with December 11, 1989 Addendum, the
AISC Specification for Structural Steel Buildings -Allowable Stress Design and
Plastic Design, June 1, 1989, the AWS D1.1-94 Structu.ral Welding Code - Steel,
the AWS 01.3-89 Structural Welding Code - Sheet Steel, and generally accepted
engineering practices.
U5/15/uu 14:42 OYIU U40 0440 1Yn11tLYY11VU bi=L
0
WJuuciuuc
R
ct-
Paul Jacqui.n & Son Const.
Page 2
May 13, 1996
All structural components supplied by Whirlwind for this project have been
fabricated in Whirlwind's facility in Houston, Texas. This facility has been
approved for Category MB Metal Building Systems as set forth in the AISC Quality
Certification Program.
This letter of certification .includes only the, steel building as furnished by
Whirlwind Steel Buildings, Inc., and specifically excludes all accessories,
anchor bolts, foundation,, masonry; or general contract work.
Sincerely,
John A. Nelson, P.E.
Whirlwind Steel Buildings, Inc.
JANIbh
I'1111� I��1/11�ir C!l Clti MCCI HI /n e+nlnn n�.a.....•�r.rr .1 • r1Yw