HomeMy WebLinkAboutProduct Approval, metal,
Business ► Professional Regulatio.n
SCIS Home j Log In I User Registration i Hot Topics Submit Surcharge stats & Facts I Publications i Contact Us BCIS Site Map Links Search j
Florida
Product Approval
r a USB.: public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
• FL # FL17022-R7
Application Type Revision
Code Version 2017
Application Status Approved
Comments 08/18/2017v. date reapply 08/21/17
Archived ❑
Product Manufacturer Extreme Metal Fabricators, LLC
Address/Phone/Email 2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
flvalidation@yahoo.com
Authorized Signature Richard McKuhen
flvalidation@yahoo.com
Technical Representative Richard McKuhen
Address/Phone/Email 2160 SW Poma Drive
Palm City, FL 34990
(772)872-8034
richard@emfab.net
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
❑ Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed LOCKE BOWDEN
the Evaluation Report
Florida License PE -49704
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By Zachary R. Priest, P.E.
0 Validation Checklist - Hardcopy Received
Certificate of Independence
FL17022 R7 COI FL 17022,1 S V CRIMP ssr.Ddf
Referenced Standard and Year (of Standard) Standard
TAS 125
UL 1897
UL 580
Equivalence of Product Standards
Certified By
Sections from the Code
Year
2003
2012
2006
Product Approval Method Method 1 Option D
Date Submitted
08/18/2017
Date Validated
08/25/2017
Date Pending FBC Approval
08/28/2017
Date Approved
10/10/2017
Summary of Prnduets
FL 00
Model, Number or Name
Description
17022.1
1- "SV Crimp" (R6)
26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel
mechanically attached to 15/32" plywood or Wood Deck with
fasteners
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
FL17022 R7 II FL 17022.1 5 V CRIMP ssr.odf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions. Install the.
Evaluation Reports
FL17022 R7 AE FL 17022.1 5 V CRIMP ssr.odf
assembly in compliance with the installation method listed in
Created by Independent Third Party: Yes
this report and applicable code sections of FBC. Refer to
manufacturer's installation instructions.
17022.2
2 - "5V Crimp" (116)
0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof
panel, mechanically attached to 15/32" plywood or Wood
Deck with exposed fasteners
Limits of Use
Approved for use In HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions.Install the
Installation Instructions
FL17022 R7 II FL 17022.2 5 V CRIMP 0.032 ALUM ssr odf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032 ALUM ssr.odf
Created by Independent Third Party: Yes
assembly in compliance with the installation method listed in
this report and applicable code sections of FBC. Refer to
manufacturer's Installation instructions.
17022.3
3 - "1.5" Mechanical Seam" (115)
1.5" rib height, 16" wide, 24 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
with clips and fasteners.
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and
limitations of use. Install the assembly in compliance with the
installation method listed in this report and applicable code
sections of FBC. Refer to manufacturer's installation
Installation Instructions
FL17022 R7 II FL 17022.3 1.5 MECHANICAL
seam 2 g ssr.odf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022.3 1,5 MECHANICAL
seam 24ga ssr odf
Created by Independent Third Party: Yes
instructions.
17022.4
4 - "1.5" Mechanical Seam" (115)
1.5" rib height, 16" wide, 0.032" aluminum, standing seam
roof panel mechanically attached to 15/32" plywood or Wood
Deck with clips and fasteners.
Limits of Use
Approved for use In HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and
limitations of use. Install the assembly in compliance with the
Installation Instructions
FL17022 R7 II FL 17022.4 MECHANCIAL SEAM
ALUMINUM ssr.odf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM
installation method listed in this report and applicable code
sections of FBC. Refer to manufacturer's installation
ALUMINUM ssr.odf
Created by Independent Third Party: Yes
instructions.
17022.5
5 - "1 in. Nail Strip" (115)
1" rib height, 16" wide, 26 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
with fasteners.
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and
limitations of use. Install the assembly in compliance with the
Installation Instructions
FL17022 R7 II FL 17022 5 1 0 NAILSTRIP ssr odf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 7022 R7 AE FL 17022.5 1,0 NAILSTRIP ssr odf
Created by Independent Third Party: Yes
installation method listed in this report and applicable code
sections of FBC. Refer to manufacturer's installation
instructions.
17022.6 16 - "1 in. Nail Strip" (115)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and
limitations of use. Install the assembly in compliance with the
Installation method listed in this report and applicable code
sections of FBC. Refer to manufacturer's installation
Instructions.
17022.7 17 - "1.5 in. Nail Strip" (115)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and
limitations of use. Install the assembly in compliance with the
installation method listed in this report and applicable code
sections of FBC. Refer to manufacturer's installation
Instructions.
17022.8 18 - "EMAX Rib" (115)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and
limitations of use. Install the assembly in compliance with the
installation method listed in this report and applicable code
sections of FBC. Refer to manufacturers installation
instructions.
17022.9 19 - " PBR MAX" (115)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and
limitations of use. Install the assembly in compliance with the
Installation method listed in this report and applicable code
sections of FBC. Refer to manufacturer's installation
instructions.
1" rib height, 16" wide, 0.032" aluminum, standing seam roof
panel mechanically attached to attached to 15/32" plywood or
Wood Deck with fasteners,
Installation Instructions
FL17022 R7 II FL 17022.6 1.0 NAIL STRIP 0.032
ALUM ssr.Ddf
Verified By: Locke Bowden, A.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022.6 1.0 NAIL STRIP 0.032
ALUM ssr.ndf
Created by Independent Third Party: Yes
1.5" rib height, 19" wide, 26 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
with fasteners.
Installation Instructions
FL17022 R7 II FL 17022.7 1.5 Nall Strip 26GA ssr.odf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022.7_ 1.5 Nai _SSrin 26GA ssr.pdf
Created by Independent Third Party: Yes
29 gauge steel, lapped roof panel mechanically attached to
15/32" plywood or wood deck with exposed fasteners.
Installation Instructions
EL17022 R7 II FL 177022.8 EMAX Rib ssr.Ddf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 177022.8 EMAX_Rib._ssr.Ddf
Created by Independent Third Parry: Yes
26 gauge steel, lapped roof panel mechanically attached to
15/32" plywood or wood deck with exposed fasteners.
Installation Instructions
FL17022 R7 II FL 17022.9 PBR RIB ssr.odf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL_17022.9 PBR RIB ssaodf
Created by Independent Third Party: Yes
Beck Next
Contact Us • • 2601 Blair stone Road. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your a -mall address released In response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click hem.
Product Approval Accepts:
®®® N
Credit Card
Safe
Palm•City, FL 34990
Compliant with Florida Building Code 2017 (6th ed.)
Compliant with Florida Product Approval Rule # 61G20-3
Compliant: Keystone Certifications
Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec. 1507.4.2
Yield strength: 50 ksi min.; Attached to min. 15/32" plywood or Wood
Deck w/ min. 0.42 specific gravity with screws. 24" Coverage
Rib Height 3/8"
Corrosion Resistant Compliant: FBC Sec. 1507.4.3
Fastener 1(Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate
3/16" min. thru deck or 5/S" embedment into wood plank. (*or sufficient length to meet
requirements)
Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to .
penetrate 3/16" min. thru deck or 5/S" embedment into wood plank. (*or sufficient length
to meet requirements)
Underlayment: To be compliant with FBC Sec. Chart 1507.1.1
Slope: Shall be in compliance with FBC Sec. 1507.
See ,Fastener attachment specifications above
Install Details: Table A Allowable Loads METHOD 1 METHOD 2 METHOD 3
METHOD 4
DESIGN PRESSURE* -86 PSF -93.5 PSF -101 PSF
-228 PSF
ROW SPACING 16" O.C. 16" O.C. 8" O.C.
6" O.C.
FASTENER SPACING (ALONG Pane[ width) 12" o.c. 12" o.c. 12" o.C.
12" O.C.
FASTENER SIZE 1 #9 #10 #10
#10
Reference Data: ARCHITECTURAL TESTING, INC. TST ID#:1527
UL 580-06 & 1897-041 Test Report =893.01-456-18 05/02/14
Test Report F3366.01-450-18 12/18/15
TAS 125-03 Test Report . D05893.02-450-18 07/22/14
*EQUIVALENCY -UL 1897-04 is egniva/entto•testStan darnf UL 1897-a �rfrr: *��np�sure margin ofsafety2:2
Locke Bowden, P.E. does not have, not will acquire a financial in cgpD?rp�faor distributing products
under this evaluation.
Locke Bowden, P.E. is not owned, operated, or controlled by any coniparh}pmlbilffb&tureM, or distributing products under this
• � o
report. • -•
;- ,46
71
r..�lO1VAL. � • tip.
''°�:tttt:atsl���%•
FL17O22.1 5V Crimp (26GA Steel), M' Wide Roof Panel - Details
Limitations:
1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6t' ed.
2. Minimum slope to be compliant with Florida Building Code 2017 6t' ed., and per with Manufacturer's installation reference.
3. Products are compliant for State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D
4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
5. Fre classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support: framing in compliance w/FBC 2017 6t' ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for
Structural Loading.
7. This report does not imply warranty, installation, recommended product use outside of this report.
— Fasteners-
#9x1-1/7'Mk. or
#10 x 1-117' Min. par7aft 141 for Row 5 V crimp Roof Panel
Spacing and Daska Pressures
Hex Washer Head Wood Screws
Deck
151W, orgreater Plywood, or
- Mod plank
14•" '
1�
3J8"
�[1P"1'IAIi1Gr _SYR11'ai'r3lNS�
Pagel Profile
{Nominal 12" Alominal 12"
O.C. o.c.
' Fasten
x 1-112" Min. or #1d X 1-1/2" Min. per
able "A" Hex Washer Head Screw
Spaced 12" o.c. across the Panel Wdth
Panel Refer to Table "A" for Spacing Along Panel
Overlap Length
Deck 15132" or greater
Plywood, or
- Wood plank