Loading...
HomeMy WebLinkAboutProduct Approval, metal, Business ► Professional Regulatio.n SCIS Home j Log In I User Registration i Hot Topics Submit Surcharge stats & Facts I Publications i Contact Us BCIS Site Map Links Search j Florida Product Approval r a USB.: public User Product Approval Menu > Product or Application Search > Application List > Application Detail • FL # FL17022-R7 Application Type Revision Code Version 2017 Application Status Approved Comments 08/18/2017v. date reapply 08/21/17 Archived ❑ Product Manufacturer Extreme Metal Fabricators, LLC Address/Phone/Email 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 flvalidation@yahoo.com Authorized Signature Richard McKuhen flvalidation@yahoo.com Technical Representative Richard McKuhen Address/Phone/Email 2160 SW Poma Drive Palm City, FL 34990 (772)872-8034 richard@emfab.net Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed LOCKE BOWDEN the Evaluation Report Florida License PE -49704 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 04/22/2024 Validated By Zachary R. Priest, P.E. 0 Validation Checklist - Hardcopy Received Certificate of Independence FL17022 R7 COI FL 17022,1 S V CRIMP ssr.Ddf Referenced Standard and Year (of Standard) Standard TAS 125 UL 1897 UL 580 Equivalence of Product Standards Certified By Sections from the Code Year 2003 2012 2006 Product Approval Method Method 1 Option D Date Submitted 08/18/2017 Date Validated 08/25/2017 Date Pending FBC Approval 08/28/2017 Date Approved 10/10/2017 Summary of Prnduets FL 00 Model, Number or Name Description 17022.1 1- "SV Crimp" (R6) 26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel mechanically attached to 15/32" plywood or Wood Deck with fasteners Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No FL17022 R7 II FL 17022.1 5 V CRIMP ssr.odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions. Install the. Evaluation Reports FL17022 R7 AE FL 17022.1 5 V CRIMP ssr.odf assembly in compliance with the installation method listed in Created by Independent Third Party: Yes this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.2 2 - "5V Crimp" (116) 0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof panel, mechanically attached to 15/32" plywood or Wood Deck with exposed fasteners Limits of Use Approved for use In HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions.Install the Installation Instructions FL17022 R7 II FL 17022.2 5 V CRIMP 0.032 ALUM ssr odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032 ALUM ssr.odf Created by Independent Third Party: Yes assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's Installation instructions. 17022.3 3 - "1.5" Mechanical Seam" (115) 1.5" rib height, 16" wide, 24 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with clips and fasteners. Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation Installation Instructions FL17022 R7 II FL 17022.3 1.5 MECHANICAL seam 2 g ssr.odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.3 1,5 MECHANICAL seam 24ga ssr odf Created by Independent Third Party: Yes instructions. 17022.4 4 - "1.5" Mechanical Seam" (115) 1.5" rib height, 16" wide, 0.032" aluminum, standing seam roof panel mechanically attached to 15/32" plywood or Wood Deck with clips and fasteners. Limits of Use Approved for use In HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the Installation Instructions FL17022 R7 II FL 17022.4 MECHANCIAL SEAM ALUMINUM ssr.odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation ALUMINUM ssr.odf Created by Independent Third Party: Yes instructions. 17022.5 5 - "1 in. Nail Strip" (115) 1" rib height, 16" wide, 26 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with fasteners. Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the Installation Instructions FL17022 R7 II FL 17022 5 1 0 NAILSTRIP ssr odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 7022 R7 AE FL 17022.5 1,0 NAILSTRIP ssr odf Created by Independent Third Party: Yes installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.6 16 - "1 in. Nail Strip" (115) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the Installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation Instructions. 17022.7 17 - "1.5 in. Nail Strip" (115) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation Instructions. 17022.8 18 - "EMAX Rib" (115) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturers installation instructions. 17022.9 19 - " PBR MAX" (115) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the Installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 1" rib height, 16" wide, 0.032" aluminum, standing seam roof panel mechanically attached to attached to 15/32" plywood or Wood Deck with fasteners, Installation Instructions FL17022 R7 II FL 17022.6 1.0 NAIL STRIP 0.032 ALUM ssr.Ddf Verified By: Locke Bowden, A.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.6 1.0 NAIL STRIP 0.032 ALUM ssr.ndf Created by Independent Third Party: Yes 1.5" rib height, 19" wide, 26 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with fasteners. Installation Instructions FL17022 R7 II FL 17022.7 1.5 Nall Strip 26GA ssr.odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.7_ 1.5 Nai _SSrin 26GA ssr.pdf Created by Independent Third Party: Yes 29 gauge steel, lapped roof panel mechanically attached to 15/32" plywood or wood deck with exposed fasteners. Installation Instructions EL17022 R7 II FL 177022.8 EMAX Rib ssr.Ddf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 177022.8 EMAX_Rib._ssr.Ddf Created by Independent Third Parry: Yes 26 gauge steel, lapped roof panel mechanically attached to 15/32" plywood or wood deck with exposed fasteners. Installation Instructions FL17022 R7 II FL 17022.9 PBR RIB ssr.odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL_17022.9 PBR RIB ssaodf Created by Independent Third Party: Yes Beck Next Contact Us • • 2601 Blair stone Road. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your a -mall address released In response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click hem. Product Approval Accepts: ®®® N Credit Card Safe Palm•City, FL 34990 Compliant with Florida Building Code 2017 (6th ed.) Compliant with Florida Product Approval Rule # 61G20-3 Compliant: Keystone Certifications Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec. 1507.4.2 Yield strength: 50 ksi min.; Attached to min. 15/32" plywood or Wood Deck w/ min. 0.42 specific gravity with screws. 24" Coverage Rib Height 3/8" Corrosion Resistant Compliant: FBC Sec. 1507.4.3 Fastener 1(Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/S" embedment into wood plank. (*or sufficient length to meet requirements) Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to . penetrate 3/16" min. thru deck or 5/S" embedment into wood plank. (*or sufficient length to meet requirements) Underlayment: To be compliant with FBC Sec. Chart 1507.1.1 Slope: Shall be in compliance with FBC Sec. 1507. See ,Fastener attachment specifications above Install Details: Table A Allowable Loads METHOD 1 METHOD 2 METHOD 3 METHOD 4 DESIGN PRESSURE* -86 PSF -93.5 PSF -101 PSF -228 PSF ROW SPACING 16" O.C. 16" O.C. 8" O.C. 6" O.C. FASTENER SPACING (ALONG Pane[ width) 12" o.c. 12" o.c. 12" o.C. 12" O.C. FASTENER SIZE 1 #9 #10 #10 #10 Reference Data: ARCHITECTURAL TESTING, INC. TST ID#:1527 UL 580-06 & 1897-041 Test Report =893.01-456-18 05/02/14 Test Report F3366.01-450-18 12/18/15 TAS 125-03 Test Report . D05893.02-450-18 07/22/14 *EQUIVALENCY -UL 1897-04 is egniva/entto•testStan darnf UL 1897-a �rfrr: *��np�sure margin ofsafety2:2 Locke Bowden, P.E. does not have, not will acquire a financial in cgpD?rp�faor distributing products under this evaluation. Locke Bowden, P.E. is not owned, operated, or controlled by any coniparh}pmlbilffb&tureM, or distributing products under this • � o report. • -• ;- ,46 71 r..�lO1VAL. � • tip. ''°�:tttt:atsl���%• FL17O22.1 5V Crimp (26GA Steel), M' Wide Roof Panel - Details Limitations: 1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6t' ed. 2. Minimum slope to be compliant with Florida Building Code 2017 6t' ed., and per with Manufacturer's installation reference. 3. Products are compliant for State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D 4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers. 5. Fre classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Support: framing in compliance w/FBC 2017 6t' ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7. This report does not imply warranty, installation, recommended product use outside of this report. — Fasteners- #9x1-1/7'Mk. or #10 x 1-117' Min. par7aft 141 for Row 5 V crimp Roof Panel Spacing and Daska Pressures Hex Washer Head Wood Screws Deck 151W, orgreater Plywood, or - Mod plank 14•" ' 1� 3J8" �[1P"1'IAIi1Gr _SYR11'ai'r3lNS� Pagel Profile {Nominal 12" Alominal 12" O.C. o.c. ' Fasten x 1-112" Min. or #1d X 1-1/2" Min. per able "A" Hex Washer Head Screw Spaced 12" o.c. across the Panel Wdth Panel Refer to Table "A" for Spacing Along Panel Overlap Length Deck 15132" or greater Plywood, or - Wood plank