HomeMy WebLinkAboutBuilding PlansSCOPE OF WORE{ - CONSTRUCT BALCONY AND STAIRS TO REPLACE EXISTING PER PLAN. - ENCLOSE PORTION OF EXISTING FIRST FLOOR FOR STORAGE TO REPLACE EXISTING. THIS IS AN ALTERATION LEVEL 2 AND MUST COMPLY WITH THE FBC 2017 FOR EXISTING BUILDINGS CHAPTER 7 AND 8. NOTES: 1) THE CONTRACTOR, SUBCONTRACTOR, SUPPLIER, ECT. SHALL VERIFY ALL DIMENSIONS, CONDITIONS AT 308 SITE, PLANS, SPECIFICATIONS, ECT. 2) STRUCTURAL FEATURES NOT DETAILED ON THESE PLANS WILL BE ADDRESSED BY THE ENGINEER AS CONSTRUCTION PROGRESSES. 3) ALL WRITTEN DIMENSIONS ON THESE DRAWINGS TAKE PRECEDENCE OVER SCALED DIMENSIONS. 4) ALL CONSTRUCTION MUST COMPLY WITH THE FLORIDA BUILDING CODE (FBC) 2017, FBC 2017 RESIDENTIAL. 5) RESIDENCE LOCATED IN NEGLIGIBLE WEATHERING AREA, AND 1N VERY HEAVY TERMITE INFESTATION AREA PER FRC 301. 6) ALL ADDITIONS, REPAIRS, AND ALTERATIONS MUST COMPLY WITH THE F.B.0 2017 FOR EXISTING BUILDINGS. STRUCTURAL NOTES 1) DESIGN LOADS IN ACCORDANCE WITH ASCE7-10. 2) SOIL BEARING CAPACITY: 2500 PSF (MIN.). 3) SLAB / FOOTINGS TO BE CONCRETE WITH A MINIMUM 2500 PSI COMPRESSIVE STRENGTH AT 28 DAYS. SEE PLAN FOR SIZES & STEEL REQUIREMENTS. 4) MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS: FOOTINGS: 3" BEAMS: 1 %i' SUSPENDED SLABS: I 'fz" 5) ALL LUMBER IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE TREATED. 6) SPLITING OR CRACKING OF STRUCTURAL COMPONENTS DUE TO INSTALATION OF HARDWARE IS NOT PERMITED. 7) UNLESS OTHERWISE NOTED, THE INSTALLATION OF SPECIFIED HARDWARE SHALL CONFORM TO THE MANUFACTURES INSTRUCTIONS AND STANDARD PRACTICI ES. 8) EXTERIOR FRAME WALLS TO BE HARDIEPLANK. HARDIEPLANK SIDING TO BE ATTACHED OVER TYVAK BUILDING WRAP OR 15# FELT OVER NEW PLYWOOD. HARDIPLANK TO BE APPLIED HORIZONTALLY WITH I %" LAPS AT TOP OF PLANK. HARDIPLANK TO BE ATTACHED WITH FASTENERS 2'/:" LONG, 0.223" HEAD DIAMETER, 0.092" SHANK DIAMETER - CORROSION -RESISTANT SIDING NAIL. FASTENERS SHALL BE PLACED IN THE OVER -LAPPED AREA AT <8.1/4""ON CENTER VERTICALLY AND 16" ON CENTER HORIZONTALLY INTO STUDS THROUGH 5/8"PLYWOOD SHEATHING. 518" PLYWOOD SHEATHING TO BE NAILED TO STUDS WITH IOD NAILS @ 4" O.C. PERIMETER AND FIELD. 0 .. Ito" = Planning & Development Services Department ® p Building & Regulations Division i Product Review Affidavit 34i1a in e er a:i Owners Name "i,f5 Applicant: Product Opening Design Pressures Product Rated Design Pressure Manufacturer Model Number Product Approval Number ( Glass T e Method of Attachment { Windows 1"J I L" Mullions Fixed Glass Block Glass y Skylights Sliding Glass Doom J Swing Type D ors �2 ,(p �.3 {(+ Q ✓ Up L. we-oT, 12n 'F'L 20335, i ~ p, iL French Doors I'" Garage Doors Hurricane Protection'F2+6�'� */"'�'Z Gou7R�'7 0.05"ALA Fldl)?A$,1 NiG t4"xi � pAntt1 2br.�.4T+sS 4T 3d" o,c. Roof Ventilation Roofing Material -/05,!co2vrc,J ItFliDwe2 cawtP 'L°J �� y.V FLU 9565.1 NIA as of-15 x 1'l2"L.Ora ce nv oOb SGewv- AT s2"o.c. I have reviewed the above components or cladding and I have approved their use in this structure. These products provide adequate resistance to The wind loads and forces specified by current code provisions. Name: yGW t+a 69- 4unr,4A%L So^, Signature- or.. T"t.AN p Seal Design Prof:. �'" r +1nitLtiw $o"'. Cert. No. TO Date: 6 n.r r �' EJ4'.T bLj— !`ryC1'TaT %old GLAet-r-rs 3�! [a" - I : O" yiG¢LG FOUNDATION SCHEDULE F 1 24" X 24" X 18" DEEP (3000 PSI) CONCRETE PAD FOOTING WITH (3)-#5 BARS EACH WAY - Planning & Development Services Department Building i& Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 - (772) 462-1553 Certification for Design Load Compliance Project Name: DAVIS Project Address: 8795 JAY GARDENS LN FORT PIERCE, FL Permit #: Occupancy Type: R Construction Type: V INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: Icomplete all that apply) 1. DESIGN CODE: Florida Building Code 2017 Edition with 20 _Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category: _ I X II_ Ill iV Exposure Category: X B C D 4. Design Wind Velocity 160 mph 124 ASD N/A LRFD End Zone Width: 3 ft S. Mean Roof Height: 20 fr Roof Pitch: 2 :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): 16.0 16.0 16.0 27.6 27.6 N/A Zone 1: _25.3 Zane 2: -44.0 Zone 3: -65.1 Zone 4: -30.0 Zone 5: -37.0 Garage: N/A 7. Design Loads: Floor: 40 PSF Roof/Dead: 5 PSF Roof/Live: 20 Balcony:. 40 PSF Dock: N/A PSF Deck: 40 PSF Stairs: 40 PSF Fence: N/A PSF Railings: 50/200 PLF / CONCENTRATED 8. Were Shear Walls Considered For Structure? _X_Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted? —Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: i certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: BOWDOIN G. HUTCHINSON 70878 Print Name Cert # & Co. Cert Auth. BENCHMARK ENGINEERING ON PLAN Signature, Date, and Seal 1, rt ,- (P" I.t:tJ('JIUL' � 20o4 -028 f' REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC �T P�. C " CAA e 806 DELAWARE AVE. FORT PIERCE, FL Company Name & Address r;�rri tic¢ tvl� r I:-r Iw�L alp a�� ID I �X15T �EGi'r'� I.1GL ,A, moo = j FQJ kJ E-� 'OSLJ rc = v�J t EIENCMMAIRK a o ua z x cza rz^ i a Z Q 1 rti O 7 z d FLOOR / ROOF FRAMING SCHEDULE J-1 2X6 WOOD JOIST (SYP #2) AT 24" O.C. J-2 2X8 P.T. WOOD JOIST (SYP#2) AT 24" O.C. B-1 DBL 2X8 (SYP #2) WOOD BEAM 9-2 2X6 (SYP #2) WOOD LEDGER B-3 2X8 (SYP #2) WOOD BEAM B-4 DBL 2X8 (SYP #2) WOOD BEAM &5 12X8 (SYP #2) WOOD LEDGER I f4"-2" m WOOD HANDRAIL CONTINUOUS AT STAIRS ONE SIDE MINIMUM WITH HANDRAIL Y r dip d4"=G�'o gGb6C RAILING PER DETAIL _ "SIMPSON" LUS28 WITH (10)- 10d NAILS EACH STRINGER 2X6 P.T. WOOD TOP RAIL 2X4 P.T. WOOD TOP.RUNNER 2X8 P.T. WOOD BEAM WITH (2)-'A" X 3 ''4" LAGS EACH POST 4X4 WOOD POST 4X4 P.T. WOOD POST EACH SIDE — 2X2 P.T. WOOD PICKETS SPACED SO LESS THAN 4" CLEAR BETWEEN "SIMPSON" ABU44 WITH (12)-16d AND 2X4 P.T. WOOD BOTTOM RUNNER (I)- A" X 3 ''A" ANCHOR BOLT EACH POST TYPICAL RAILING DETAIL pts... 2X P.T.W ID TREAD (TYPICAL) — 1X P.T, W D RISER 2 X 12 P.T. *000 STRINGER AT EACH END AND 24" O.C. MAX "SIMPSON" HGAM10 EACH STRINGER WITH (4)- SDS'/.X I W' TO STRINGER AND (4)-' X 1 '/T TITEN TO FLOOR TYPICAL STAIR DETAIL ots... 2X4 P.T. LANDING WITH 2XDECKING SEE FLOOR PLAN FOR DIMENSIONS y rr. A ZL ir�li+s'I11 .^. EXISTING WOOD HEADER 2 X 4 WOOD TOP PLATE WITH /I' X 3" LAG SCREWS AT 12" U.C. STRAP EACH STUD TO TOP PLATE WITH "SIMPSON" SP4 WITH (6)- IOD NAILS OR "SIMPSON- H 2.5A WITH (10)- 8D NAILS (EVERY STUD) HARDIE PLANK SIDING PER STRUCTURAL NOTE 48 2 X 4 WOOD STUDS AT 12" O.C. STRAP EACH STUD TO BOTTOM WITH "SIMPSON" --- SP4 WITH (6) -- IOD NAILS OR "SIMPSON" H 2 5A WITH (10)- 8D NAILS (EVERY STUD) P.T. 2 X 4 WOOD BOTTOM PLATE. WITH !:2" X 5 %a" EXP. BOLT AT 24" O.C. 1 FINISHED GRADE ltaµ EXISTING CONCRETE ("''FOUNDATION TYPICAL FILL—IN WALL SECTION Fits... u PROVIDE FLASHING AT ROOF PITCH CHANGE rf `SIMPSON- LUS26 WITH (4)- IOd TO LEDGER AND (4)- 10d f TO JOIST EACH JOIST / 2X6 WOOD LEDGER WITH 'A" X 3'/z" LAG BOLTS AT24" O.C. _ 2X6 P.T. WOOD DECKING WITH (2)- 41 OX3- SCREWS EACH JOIST y 2X8 WOOD JOIST AT 24" WITH "SIMPSON" LUS28 WITH (10)- 10d EACH END TO BEAM y�. 2X8 WOOD BEAM ATTACH TO POST WITH (2)-'A" DIA. THRU BOLTS AND TO LEDGER WITH HUS28 WITH (30)-16d 2X8 WOOD LEDGER WITH'/z" X3 h" LAG SCREWS AT24" O.C. STAGGERED I METAL ROOFING PER ROOF ATTACHMENT ON PRODUCT APPROVAL OVER IX4 WOOD /J PURLINS AT 12" O.C. WITH (2)- #12X3" SCRESIEACH JOIST 2X61 WOOD JOIST AT 24" O.C. "�. %` SIMPSON STRAP H8 WITH (10)-I0dX1'R'jEACH JOIST — -1X4 P.T. WD. FASCIA a �- ---- OPEN CEILING/SOFFIT \ DB1.2X8 wooly BEAM ON POST CAP AC4 (***) *** NOTE: USE "SIMPSON" j - \N (28)-16d AND (2)- LSTA ACE4 WITH (20)-16D FOR END 18 W/(14)- IOd EACH POST TO POSTS REAM i 4X4 P.T. WOOD POST I; RAILING PER DETAIL Iry r: DOUBLE 2X8 P.T. WOOD BEAM WITH (2)- V" X 6" LAGS EACH POST 4X4 P.T. WOOD POST SIMPSON ABU44 WITH (12)- 16d AND 0)- 5/8"m X 12" ANCHOR BOLT (3000 PSI) CONC. FOUNDATION (PER SCH) -tttr to ttt IIflf TYPICAI. 4X4, POST DETAIL "t,... \�\\��>�IUTC&/N//, 30 g7a ; E=i {', w pO FL iZ\0 4��\\� SPE C A�� Ems' `� R_I $slora } 7' NGz. �U va Z C HANk z� oze ¢°a 110-2 r zd v a� x