Loading...
HomeMy WebLinkAboutCertification for Design Load CompliancePlanning & Development Services Department ® Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-155 ~{ FRECEIVED 1 2019 Certification for Design Load Compliance Wade Jurne Homes - 1202 y, Permitting project Name: Y Project Address: 022LWP001 - 7103 Brookline ave Ft. Pierce, FL 34951 Permit #: Occupancy Type: Construction Type: INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2017 Code Sixth Edition with 20 N/A Supplements using ASCE 7-10 2. -Structure Designed as (check one): X Enclosed Partially Enclosed Open 3. Risk Category: I X II III IV Exposure Category: B X C D 4. Design Wind Velocity 160 mph ASD X LRFD End Zone Width: 3.33 ft 5. Mean Roof Height 11 ft Roof Pitch: `i' :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: +19.3,-30.6 Zone 2: +19.3,-53.3 Zone 3: +19.3,-78.9 Zone 4: +33.5,-36.3 Zone 5: +33.5, 44.8 Garage: +31.7/-38.6 7. Design Loads: Floor: 40 PSF Roof/Dead: 17 PSF Roof/Live: 20 Balcony: N/A PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: 50 PSF 8. Were Shear Walls Considered For Structure? Y Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? Y Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the a` plifale structural portions of the building codes currently adopted �c�r` s I-LEP County. I als�����ti 1c1 thll ��t+F,(ycu ral elements depicted on these plans provide adequate rest r� KS, OO forces sp J /®®LUCI®UN ®Y `� y'�t;.''��C $ ' • �� James G. Friling G Print Name Cert # & CO.ELQP Y S E OF •' = PE #77824 COA #27228 Signatul Ce�9f � I Mulhern + Kulp Structural Engineering - 300 Brookside Ave, Ambler, PA 19002 ® A � •\`� Company Name &'Address ���e�o�s's►��t�oe. Revised 12/07/2018 MAR 19 2019