HomeMy WebLinkAboutCertification for Design Load CompliancePlanning & Development Services Department
® Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-155
~{ FRECEIVED
1 2019
Certification for Design Load Compliance
Wade Jurne Homes - 1202 y, Permitting
project Name: Y
Project Address: 022LWP001 - 7103 Brookline ave Ft. Pierce, FL 34951
Permit #: Occupancy Type: Construction Type:
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida 2017 Code Sixth Edition with 20 N/A Supplements using ASCE 7-10
2. -Structure Designed as (check one): X Enclosed Partially Enclosed Open
3. Risk Category: I X II III IV Exposure Category: B X C D
4. Design Wind Velocity 160 mph ASD X LRFD End Zone Width: 3.33 ft
5. Mean Roof Height 11 ft Roof Pitch: `i' :12 Parapet: N/A ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: +19.3,-30.6 Zone 2: +19.3,-53.3 Zone 3: +19.3,-78.9 Zone 4: +33.5,-36.3 Zone 5: +33.5, 44.8 Garage: +31.7/-38.6
7. Design Loads: Floor: 40 PSF Roof/Dead: 17 PSF Roof/Live: 20 Balcony: N/A PSF
Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: 50 PSF
8. Were Shear Walls Considered For Structure? Y Yes Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? Y Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the a` plifale structural portions of the building codes currently adopted �c�r` s I-LEP
County. I als�����ti 1c1 thll ��t+F,(ycu ral elements depicted on these plans provide adequate rest r� KS,
OO
forces sp J /®®LUCI®UN ®Y
`� y'�t;.''��C $ ' • �� James G. Friling
G Print Name Cert # & CO.ELQP
Y S E OF •' = PE #77824 COA #27228
Signatul Ce�9f �
I Mulhern + Kulp Structural Engineering - 300 Brookside Ave, Ambler, PA 19002
® A � •\`� Company Name &'Address
���e�o�s's►��t�oe.
Revised 12/07/2018 MAR 19 2019