MAY 08 2020
Contractor: ST. Lucie County, permitting
Ferreira
13000 SE Flora Ave.,
Hobe Sound,FL 33455
Site Address:
Nettles Island Inc.
9801 S. Ocean Dr.
Jensen Beach,FL 34957
Permit#: SLC-1007-0330
Re: Renovation to Existing Perimeter Seawall,Boat Ramp, and Bridge System
St.Lucie County Building Department
Dear Building Official:
CSM engineering was hired to produce construction renovation drawings for the perimeter seawall
system, batter pile system, and bridge system. Construction drawings were produced on 7-12-18. CSM
also performed ongoing inspections during the renovation of the seawall system from commencement to
completion:
The Passed Inspections include the following,but not limited to:
1. Bridge progress Inspections
2. Bridge Final Inspection
3. Boat Ramp Progress and Final Inspections
4. Seawall Concrete Cap Progress and Final Inspections
5. Seawall Batter Pile Progress and Final Inspections
6. Seawall Final Inspection
7. Steel Sheet Pile Cleaning and Coating Progress and Final Inspections
8. Concrete Spall Progress Inspections
9. Concrete Spall Final Inspection
10. Concrete Cap Crack Injection and Sealer Application Progress and Final Inspections
I hereby certify that the seawall, bridge, and batter pile system restorations were constructed in
conformance with the FBC 2017 6th Edition and CSM drawings dated 7-12-18.
I hereby certify that the seawall, bridge, and batter pile systems listed above were restored/constructed in
conformance with the FBC 2017 6th Edition,Existing FBC 2017,ACI Concrete Code,NDS Timber
Code,ASD,AISC, and CSM drawings with latest revision date of 7-12-2018. To the best of my
knowledge, all work performed by the contractor meets or exceeds the above technical codes and CSM
drawings. I Certify that the permit drawings with a latest revision of 7-12-2018, meet or exceed the
requirements of the above technical listed codes in relation to strength, stress, strain, stability, loads, and
load combinations. I Certify that the CSM drawings as stated above conform to the applicable laws as to
egress,type of construction, and general arrangement.No electrical,mechanical, or plumbing work was
performed under this permit.
i
2 of 2
Passed Inspections from commencement to completion:
August 17,24, and 30 - 2018
September 7, 10, 14, 17, 20, 24,25, and 27 -2018
October 1,4, 5, 8, 10, 15, 18, 22,24,26, 29, and 30 -2018
November 2, 5, 9, 12, 14, 19,21, 23, 26, and 29-2018
December 3,4, 12, 14, 17, 19, 20, and 24-2018
January 7, 9, 14, 15, 17, 21, 23, 24, 28, 29, and 31 -2019
February 4, 5, 7, 12, 13, 18,23,24,26, and 30-2019
March 4, 6, 11, 12, 13, 18,20, 22,26, and 28-2019
April 1, 3, 5, 8, 9, 11, 16, 18, 23,24, 26, and 30-2019
May 2, 6, 8, 10, 14, 16,21, 23, 24, 27,and 29-2019
June 3, 5, 7, 12, 14, 20,25, and 28
July 1,2019 was the final passed inspection
Best Regards,
Jj\IIIIII/I
II
®m®
�� Q��:•'••`GEIVS � ��
�:
No.76910 _
STATE OF ..J4
•:•��/
e
�
Le --a-a oat
aO �' 111111
Charles A. Darden Jr.
CSM Engineering,LLC
Florida Registered Professional Engineer,#76910