Loading...
HomeMy WebLinkAboutEngineering (2) 1: SM N ( E E R I N Rt=CE=IVI=D C;VIL • SFRUCTURAL,- PAAkItJE April 2,2020 MAY 08 2020 Contractor: ST. Lucie County, permitting Ferreira 13000 SE Flora Ave., Hobe Sound,FL 33455 Site Address: Nettles Island Inc. 9801 S. Ocean Dr. Jensen Beach,FL 34957 Permit#: SLC-1007-0330 Re: Renovation to Existing Perimeter Seawall,Boat Ramp, and Bridge System St.Lucie County Building Department Dear Building Official: CSM engineering was hired to produce construction renovation drawings for the perimeter seawall system, batter pile system, and bridge system. Construction drawings were produced on 7-12-18. CSM also performed ongoing inspections during the renovation of the seawall system from commencement to completion: The Passed Inspections include the following,but not limited to: 1. Bridge progress Inspections 2. Bridge Final Inspection 3. Boat Ramp Progress and Final Inspections 4. Seawall Concrete Cap Progress and Final Inspections 5. Seawall Batter Pile Progress and Final Inspections 6. Seawall Final Inspection 7. Steel Sheet Pile Cleaning and Coating Progress and Final Inspections 8. Concrete Spall Progress Inspections 9. Concrete Spall Final Inspection 10. Concrete Cap Crack Injection and Sealer Application Progress and Final Inspections I hereby certify that the seawall, bridge, and batter pile system restorations were constructed in conformance with the FBC 2017 6th Edition and CSM drawings dated 7-12-18. I hereby certify that the seawall, bridge, and batter pile systems listed above were restored/constructed in conformance with the FBC 2017 6th Edition,Existing FBC 2017,ACI Concrete Code,NDS Timber Code,ASD,AISC, and CSM drawings with latest revision date of 7-12-2018. To the best of my knowledge, all work performed by the contractor meets or exceeds the above technical codes and CSM drawings. I Certify that the permit drawings with a latest revision of 7-12-2018, meet or exceed the requirements of the above technical listed codes in relation to strength, stress, strain, stability, loads, and load combinations. I Certify that the CSM drawings as stated above conform to the applicable laws as to egress,type of construction, and general arrangement.No electrical,mechanical, or plumbing work was performed under this permit. i 2 of 2 Passed Inspections from commencement to completion: August 17,24, and 30 - 2018 September 7, 10, 14, 17, 20, 24,25, and 27 -2018 October 1,4, 5, 8, 10, 15, 18, 22,24,26, 29, and 30 -2018 November 2, 5, 9, 12, 14, 19,21, 23, 26, and 29-2018 December 3,4, 12, 14, 17, 19, 20, and 24-2018 January 7, 9, 14, 15, 17, 21, 23, 24, 28, 29, and 31 -2019 February 4, 5, 7, 12, 13, 18,23,24,26, and 30-2019 March 4, 6, 11, 12, 13, 18,20, 22,26, and 28-2019 April 1, 3, 5, 8, 9, 11, 16, 18, 23,24, 26, and 30-2019 May 2, 6, 8, 10, 14, 16,21, 23, 24, 27,and 29-2019 June 3, 5, 7, 12, 14, 20,25, and 28 July 1,2019 was the final passed inspection Best Regards, Jj\IIIIII/I II ®m® �� Q��:•'••`GEIVS � �� �: No.76910 _ STATE OF ..J4 •:•��/ e � Le --a-a oat aO �' 111111 Charles A. Darden Jr. CSM Engineering,LLC Florida Registered Professional Engineer,#76910