MIAMI-DADE COUNTY
® �' PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) . iv.mi.imid.ide.gov/econonry
GAF
1 Campus Drive
Parsipanny, NJ 07054
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Leak Barriers and Roof Deck Protection
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA 18-0119.15 and consists of pages 1 through 8.
The submitted documentation was reviewed by Jorge L. Acebo.
NOA No.: 18-1023.10
Expiration Date: 02/22/23
Approval Date: 05/09/19
Page 1 of 8
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub -Category: Underlayment
Material: SBS/Polypropylene/Asphalt
SCOPE:
This approves GAF Leak Barriers and Roof Deck Protection underlayments, to be used on existing roof assemblies as
described in this Notice of Acceptance, designed to comply with the Florida Building Code and the High Velocity
Hurricane Zone of the Florida Building Code.
PRODUCTS DESCRIPTION:
Product Dimensions
WeatherWatch° 36" x 50' rolls
Mineral Surfaced Leak 36" x 66.7' rolls
Barrier
Manufacturing
Location # 1, 8
Test Product
Specification Description
ASTM D1970 Granular surfaced modified, fiberglass reinforced,
bituminous sheet material for use as a leak barrier
underlayment in sloped roof assemblies.
Designed as an ice & rain shield.
StormGuardo Film 36" x 66.7' rolls ASTM D1970 Modified, fiberglass reinforced, bituminous sheet
Surfaced Leak Barrier material for use as a high temperature leak barrier
Manufacturing underlayment in sloped roof assemblies.
Location # 1, 8 Designed as an ice & rain shield.
Liberty' SBS Self -
Adhering Base/Ply
Sheet
Manufacturing
Location # 1, 8
Deck -Armor"' Premium
Breathable Roof Deck
Protection
Manufacturing
Location # 7
Tiger Pawl"' Roof Deck
Protection
Manufacturing
Location # 2, 4, 5, 7
39 3/s" x 66' rolls ASTM D1970 Self -adhering SBS roof membrane.
ASTM D4601
Type II
54" x 222' rolls
ASTM D226
A UV -stabilized polypropylene breathable
48" x 250' rolls
Type II
underlayment. To be used for roof deck
48" x 100' rolls
protection as an underlayment in sloped roof
assemblies.
48" x 250' rolls
ASTM D226
A UV -stabilized polypropylene non -breathable
48" x 100' rolls
Type 11
underlayment. To be used for roof deck protection
as an underlayment in sloped roof assemblies.
NOA No.: 18-1023.10
MIAMI•DADE COUNTY Expiration Date: 02/22/23
Approval Date: 05/09/19
Page 2 of 8
PRODUCTS DESCRIPTION:
Test Product
Product Dimensions Specification Description
FeltBuster° High- 48" x 250' rolls ASTM D226 A UV -stabilized polypropylene non -breathable
Traction Synthetic Type II underlayment. To be used for roof deck protection
Roofing Felt as an underlayment in sloped roof assemblies.
Manufacturing
Location # 6, 7
Shingle -Mate' Roof
36" x 144' rolls
ASTM D226
Fibergass-reinforced asphalt felt underlayment. To
Deck Protection
Type I
be used for roof deck protection as an
Manufacturing
underlayment in sloped roof assemblies.
Location # 3
Liberty'" SA Glass Cap
39 3/8" x 34' rolls
ASTM D1970
Granular surfaced modified, fiberglass reinforced,
Sheet
ASTM D6163
self -adhering SBS roof membrane.
Manufacturing
ASTM D7530
Location # 8
GAFGLAS° Ply 4
39.37"
ASTM D2178
Asphalt impregnated glass felt with asphalt
Manufacturing
(1 meter) Wide
Type IV
coating.
Location # 8, 9, 10
GAFGLAS® F1exPly'°' 6
39.37"
ASTM D2178
Asphalt impregnated glass felt with asphalt
Manufacturing
(1 meter) Wide
Type VI
coating.
Location # 8, 9, 10
Tri-Ply° Ply 4
39.37"
ASTM D2178
Asphalt impregnated glass felt with asphalt
Manufacturing
(1 meter) Wide
Type IV
coating.
Location # 8, 9, 10
MANUFACTURING LOCATION:
1. Mt. Vernon, IN
2. Mission, British Columbia
3. Pryor, OK
4. Qingdao, China
5. Charleston, SC
6. Spartanburg, SC
7. Dadra, India
8. Savannah, GA
9. Mobile, AL
10. Fontana, CA
NOA No.: 18-1023.10
MIAMI•DADE COUNTY Expiration Date: 02/22/23
Approval Date: 05/09/19
Page 3 of 8
EVIDENCE SUBMITTED:
Test Agency
Test Identifier
Test Name/Report
Date
Intertek Testing Services NA Ltd.
3077464-01
ASTM D1970
08/23/06
3090131
Wind Uplift and Self Sealability
08/23/06
100258583COQ-OIOA
ASTM D226 Type II
01/11/11
100673818COQ-003
ASTM D226 Type II
06/13/13
10157289000Q-005
ASTM D226 Type II
04/17/14
F8549.02-106-18-RO
ASTM D226 Type II
11/08/16
PRI Construction Materials
RGM-023-02-01
ASTM D4798
05/16/07
Technologies, LLC.
GAF-112-02-01
ASTM D226 Type II
03/15/06
GAF-238-02-01
ASTM D1970
03/03/10
GAF-323-02-01
ASTM D1970
11/30/11
GAF-324-02-01
ASTM D1970
11/30/11
GAF-325-02-01
ASTM D1970
11/30/11
GAF-326-02-01
ASTM D1970
11/30/11
GAF-275-02-01
ASTM D1970
11/11/10
GAF-344-02-01
ASTM D1970
04/23/12
GAF-339-02-01
ASTM D226 Type 1
03/14/12
ELK-311-02-01
ASTM D1970
09/11/07
GAF-446-02-01
ASTM D226 Type I
09/26/13
GAF-518-02-01
ASTM D226 Type II
06/04/14
GAF-818-02-01
ASTM D4533
12/06/17
GAF-829-02-01
ASTM D226 Type II
01/15/18
GAF-314-02-01
ASTM D2178
07/21/11
GAF-315-02-01
ASTM D2178
07/21/11
GAF-826-02-01
ASTM D226 Type II
07/12/18
ASTM D4533
GAF-847-02-01
ASTM D226 Type II
06/05/18
ASTM D4533
GAF-914-02-01
ASTM D226 Type II
04/11/19
ASTM D4533
Trinity-ERD
GAF-SC13285.17-1
ASTM D1970
03/08/17
GAF-SC13285.17-3
ASTM D1970
03/08/17
GAF-SC13285.17-4
ASTM D1970
03/08/17
GAF-SC13285.17-2
ASTM D4601 Type II
03/08/17
GAF-SC9700.08.15-R1
ASTM D2178
02/08/17
GAF-SC12915.09.17
ASTM D1970
12/11/17
GAF-SC12915.09.17
ASTM D6163
12/11/17
GAF-SC12915.09.17
ASTM D7530
12/11/17
NEMOjetc.
4S-GAF-18-001.01.19-1
ASTM D2178 Type IV
1/2/2019
4S-GAF-18-001.01.19-1
ASTM D2178 Type VI
1/2/2019
NOA No.: 18-1023.10
MIAMI•DADE COUNTY Expiration Date: 02/22/23
Approval Date: 05/09/19
Page 4 of 8
APPROVED ASSEMBLIES:
Deck Type 1: Wood, non -insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(1): Anchor sheet mechanically fastened to deck, membrane adhered.
Base Sheet: Two plies of ASTM D 226 Type I or Shingle -Mate' Roof Deck Protection OR one or more plies
of ASTM D 226 Type II, Deck -Armor" Premium Breathable Roof Deck Protection, FeltBuster°
High -Traction Synthetic Roofing Felt, or Tiger Pawl" Roof Deck Protection with a minimum 4"
side lap and a 6" end lap mechanically fastened to the deck with approved nails and tin caps 6"
o.c. at the laps and four staggered rows 12" o.c. in the field of the roll.
If roof is exposed to rain/snow, tape all end and side laps with approved butyl adhesive based
seam/cover tape or an approved waterproof cloth duct tape (follow the tape's manufacturer's
installation instructions). Always apply tape over all fasteners at the center of the roll or the end
laps to help prevent rain or snow from entering at the fastneners.
Membrane: One or more plies of WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film
Surfaced Leak Barrier, Liberty-' SA Glass Cap Sheet, or LibertyT"' SBS Self -Adhering Base/Ply
Sheet membrane with a minimum 3" side lap and 6" end lap. Place the first course of membrane
parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release
membrane as the membrane is applied. Vertical strapping of the roof with WeatherWatch®
Mineral Surfaced Leak Barrier, or StormGuard® Film Surfaced Leak Barrier is acceptable.
Surfacing: Approved Roofing Assembly.
Deck Type 1: Wood, non -insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(2): Membrane mechanically fastened to deck.
Separator Sheet: One or more plies of GAF GAFGLAS° Ply 4, GAFGLAS° F1exPlyT"' 6, Rosin Paper, ASTM D
226 Type I or Type 11, Shingle -Mate' Roof Deck Protection, Deck -Armor" Premium Breathable
Roof Deck Protection, FeltBuster° High -Traction Synthetic Roofing Felt, or Tiger PawT" Roof
Deck Protection loose laid.
Membrane: One or more plies of WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film
Surfaced Leak Barrier, Liberty" SA Glass Cap Sheet, or Liberty"' SBS Self -Adhering Base/Ply
Sheet membrane mechanically fastened with a minimum 3" side lap and a 6" end lap to deck
through the separator sheet with approved nails and tin caps 6" o.c. at the laps and two staggered
rows 12" o.c. in the field of the roll.
Surfacing: Approved Roofing Assembly.
NOA No.: 18-1023.10
Expiration Date: 02/22/23
Approval Date: 05/09/19
Page 5 of 8
Deck Type 1: Wood, non -insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(3): Anchor sheet mechanically fastened to deck, membrane adhered.
Secondary Water Install a minimum 4" wide WeatherWatch® Mineral Surfaced Leak Barrier, Liberty"SBS Self -
Barrier: Adhering Base/Ply Sheet, Liberty'.SA Glass Cap Sheet, or StormGuard® Film Surfaced Leak
(Optional) Barrier membrane over the joints of the plywood roof deck prior to installation of the base sheet.
Do not overlap end or side joints. All side and end laps should be butted firmly side by side,
flush with each other but not overlapped. Do not leave the WeatherWatch® Mineral Surfaced
Leak Barrier, or StormGuard® Film Surfaced Leak Barrier membrane exposed for more than 30
days without a roof deck protection underlayment protecting the secondary water barrier.
Base Sheet: Two plies of ASTM D 226 Type I or Shingle -Mate® Roof Deck Protection OR one or more plies
of ASTM D 226 Type II, Deck -Armor'°' Premium Breathable Roof Deck Protection, FeltBuster°
High -Traction Synthetic Roofing Felt, or Tiger Paw" Roof Deck Protection with a minimum 4"
side lap and a 6" end lap mechanically fastened to the deck with approved nails and tin caps 6"
o.c. at the laps and four staggered rows 12" o.c. in the field of the roll.
If roof is exposed to rain/snow, tape all end and side laps with approved butyl adhesive based
seam/cover tape or an approved waterproof cloth duct tape (follow the tape manufacturer's
installation instructions). Always apply tape over all fasteners at the center of the roll or the end
laps to help prevent rain or snow from entering at the fasteners.
Surfacing: Approved Roofing Assembly.
Deck Type 1: Wood, non -insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(4): Anchor sheet mechanically fastened to deck, membrane adhered.
Base Sheet: Two plies of ASTM D 226 Type I or Shingle -Mate' Roof Deck Protection OR one or more plies
of ASTM D 226 Type II, Deck -Armor" Premium Breathable Roof Deck Protection, FeltBuster°
High -Traction Synthetic Roofing Felt, or Tiger Paw"' Roof Deck Protection with a minimum 4"
side lap and a 6" end lap mechanically fastened to the deck with approved nails and tin caps 6"
o.c. at the laps and four staggered rows 12" o.c. in the field of the roll.
If roof is exposed to rain/snow, tape all end and side laps with approved butyl adhesive based
seam/cover tape or an approved waterproof cloth duct tape (follow the tape's manufacturer's
installation instructions). Always apply tape over all fasteners at the center of the roll or the end
laps to help prevent rain or snow from entering at the fastneners.
Membrane: One or more plies of StormGuard® Film Surfaced Leak Barrier membrane with a minimum 4"
side lap and 6" end lap. Place the first course of membrane parallel to the eave, rolling the
membrane to obtain maximum contact. Remove the release membrane as the membrane is
applied.
Surfacing: Approved for Metal roofing, Slate, and Asphalt Shingle assemblies.
NOA No.: 18-1023.10
M1AM1•oADE couNnr Expiration Date: 02/22/23
• Approval Date: 05/09/19
Page 6 of 8
LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyT" SBS Self -
Adhering Base/Ply Sheet, Liberty"' SA Glass Cap Sheet, Shingle -Mate' Roof Deck Protection, Deck -Armor"'
Premium Breathable Roof Deck Protection, FeltBuster° High -Traction Synthetic Roofing Felt, and Tiger Pawl"
Roof Deck Protection shall not be used as roof tile underlayment.
3. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code. WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak
Barrier, LibertyT"' SBS Self -Adhering Base/Ply Sheet, Liberty-' SA Glass Cap Sheet, Shingle -Mate® Roof Deck
Protection, Deck -Armors" Premium Breathable Roof Deck Protection, FeltBuster° High -Traction Synthetic
Roofing Felt, and Tiger Paw` Roof Deck Protection shall be installed in strict compliance with applicable
Building Code.
4. WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, Liberty-, SBS Self -
Adhering Base/Ply Sheet, LibertyT' SA Glass Cap Sheet, Shingle -Mate' Roof Deck Protection, Deck -Armor"'
Premium Breathable Roof Deck Protection, FeltBuster° High -Traction Synthetic Roofing Felt, and Tiger Pawl"
Roof Deck Protection membranes shall be applied to a smooth, clean and dry surface with deck free of
irregularities.
5. WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyT"' SBS Self -
Adhering Base/Ply Sheet, LibertyT"' SA Glass Cap Sheet, Shingle -Mate' Roof Deck Protection, Deck -Armor"'
Premium Breathable Roof Deck Protection, FeltBuster° High -Traction Synthetic Roofing Felt, and Tiger Pawl"
Roof Deck Protection membranes shall not be applied over an existing roof membrane.
6. WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyT" SBS Self -
Adhering Base/Ply Sheet, Liberty"' SA Glass Cap Sheet, Shingle -Mate® Roof Deck Protection, Deck-ArmorT"'
Premium Breathable Roof Deck Protection, FeltBuster° High -Traction Synthetic Roofing Felt, and Tiger Pawl"
Roof Deck Protection shall not be left exposed as a temporary roof for longer than 30 days of application.
7. WeatherWatch® Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, Liberty'" SBS Self -
Adhering Base/Ply Sheet, Liberty"' SA Glass Cap Sheet, Shingle -Mate' Roof Deck Protection, Deck -Armor"
Premium Breathable Roof Deck Protection, FeltBuster° High -Traction Synthetic Roofing Felt, and Tiger Paws"
Roof Deck Protection may be used with any approved roof covering Notice of Acceptance listing WeatherWatch®
Mineral Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, Liberty"' SBS Self -Adhering Base/Ply
Sheet, Liberty"' SA Glass Cap Sheet, Shingle -Mate' Roof Deck Protection, Deck -Armor"' Premium Breathable
Roof Deck Protection, FeltBuster° High -Traction Synthetic Roofing Felt, and Tiger Paw" Roof Deck Protection as
a component part of an assembly in the Notice of Acceptance. If WeatherWatch® Mineral Surfaced Leak Barrier,
StormGuard® Film Surfaced Leak Barrier, LibertyT"' SBS Self -Adhering Base/Ply Sheet, LibertyT" SA Glass Cap
Sheet, Shingle -Mate' Roof Deck Protection, Deck -Armor'" Premium Breathable Roof Deck Protection,
FeltBuster° High -Traction Synthetic Roofing Felt and Tiger Pawl"' Roof Deck Protection are not listed; a request
may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department
for approval provided that appropriate documentation is provided to detail compatibility of the products, wind
uplift resistance, and fire testing results.
8. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels. Sweep
the deck thoroughly to remove any dust and debris prior to application. Install when temperatures are 45' F and
rising.
9. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane
from the center outward in both directions.
NOA No.: 18-1023.10
Expiration Date: 02/22/23
Approval Date: 05/09/19
Page 7 of 8
LIMITATIONS:
10. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention to
overlap areas.
11. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control
Notice of Acceptance and applicable Building Code.
12. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
13. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city
and state of manufacturing facility, and the following statement: "Miami -Dade County Product Control Approved"
or the Miami -Dade County Product Control Seal as shown below.
QMlI•DADE COUNTY
END OF THIS ACCEPTANCE
NOA No.: 18-1023.10
Expiration Date: 02/22/23
Approval Date: 05/09/19