HomeMy WebLinkAbout4003 AVENUE R PERMIT NUM 2009-0297 007 REVISED 9/18/20#2009-0294 WOOD DECK SYSTEM LIMITA 1. A slip sheet is required with Ply 4 GENERAL LIMITATIONS: 2. 4. 6. 10. Fire classification is not part of this ratings of this product. Insulation may be installed in multip Approval guidelines. All other layer EVT range and at a rate of 20-40 lbs. All standard panel sizes are acceptal shall be 4' x 4' maximum. An overlay and/or recovery board in when the base sheet is fully mopp, mopping with approved asphalt, 12' each sidelap and one down the center is not acceptable. A 6" break she application of either system shall be Note: Spot attached systems shall Fastener spacing for insulation attach. tested in compliance with Testing AF 275 lbf. insulation attachment shall n Fastener spacing for mechanical attac fastener resistance value in conjuncti fastener resistance be less than that r( prepared, signed and sealed by a Floi Consultant may be submitted. Said r Testing Application Standards TAS 1 117. Perimeter and corner areas shall cor densities shall be increased for both i Standard RAS 117. Calculations p Registered Architect, or Registered NOA, General Limitation #9 will n All attachment and sizing of perimeti Roofing Application Standard RAS 1 The maximum designed pressure lim perimeters, and corners). Neither rati enhanced pressure zones (i.e. perime- referred within this NOA, General All products listed herein shall have Rule 61 G20-3 of the Florida Admini S: Ply 6 when used as a mechanically fastened base or anchor sheet. refer to a current Approved Roofing Materials Directory for fire layers. The first layer shall be attached in compliance with Product Control shall be adhered in a full mopping of approved asphalt applied within the ,q., or mechanically attached using the fastening pattern of the top layer e for mechanical attachment. When applied in approved asphalt, panel size alation panel is required on all applications over closed cell foam insulations 1. If no recovery board is used the base sheet shall be applied using spot diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at of the sheet allowing a continuous area of ventilation. Encircling of the strips l be placed every 12' in each ribbon to allow cross ventilation. Asphalt t a minimum rate of 12 lbs./sq. e limited to a maximum design pressure of -45 psf. nent is based on a Minimum Characteristic Force (F') value of 275 lbf., as dication Standard TAS 105. If the fastener value, as field-tested, are below t be acceptable. anent of anchor/base sheet or membrane attachment is based on a minimum n with the maximum design value listed within a specific system. Should the luired, as determined by the Building Official, a revised fastener spacing, 3a registered Professional Engineer, Registered Architect, or Registered Roof vised fastener spacing shall utilize the withdrawal resistance value taken from )5 and calculations in compliance with Roofing Application Standard RAS ply with the enhanced uplift pressure requirements of these areas. Fastener sulation and base sheet as calculated in compliance with Roofing Application -pared, signed and sealed by a Florida registered Professional Engineer, :oof Consultant (When this limitation is specifically referred within this t be applicable.) nailers, metal profile, and/or flashing termination designs shall conform with 1 and applicable wind load requirements. ration listed shall be applicable to all roof pressure zones (i.e. field, nal analysis, nor extrapolation shall be permitted for enhanced fastening at ;rs, extended corners and corners). (When this limitation is specifically imitation #7 will not be applicable.) quality assurance audit in accordance with the Florida Building Code and rative Code. ENIJ OF THIS ACCEPTANCE NOA No.: 15-0108.03 Expiration Date: 04/13/20 Approval Date: 04/09/15 Page 13 of 13