HomeMy WebLinkAboutEnergy CodeJ
4 .
FORM R405-2017 .
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation. -.Residential Performance Method
Project Name: Evon Residence
Builder Name:
Street: 2969 Admiral
Permit Office:
City, State, Zip: Fort Pierce, FL , 34982
Permit Number:
Owner: Evon Haha
Jurisdiction:
Design Location: FL; Fort Pierce
County:: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1586.7 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block . Int Insul, Exterior
R=4.1 1390.70 ft2 -
b. Frame,- Wood, Adjacent
R=13.0 196.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedroom's 3
d. N/A
R= ft2
10. Ceiling Types (1523.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)..
R=30.0 1523.00 ft z
6. Conditioned floor area above grade (ft2) 1523
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c.
11. Ducts
R= ft2
R ft2
7. Windows(175.1 sqft.), = Description Area
a. Sup: Attic, Ret: Attic, AH: Garage.
6 623
a. U-Factor: Dbl, U=0.34: 175.10 ft2
SHGC: SHGC=0.32
b. U-Factor: N/A ft2
12. Cooling systems:
kBtu/hr Efficiency
SHGC:
a. Central Unit
34.4 SEER:15.00
c. U-Factor: - N/A ft2.
SHGC:
13. Heating systems.
kBtu/hr Efficiency
d.. U-Factor:, N/A ft2
a. Electric Heat Pump
34.4 HSPF:8.50
- SHGC:
Area Weighted Average Overhang Depth: 3.241 ft.
Area Weighted Average SHGC: 0.320
14. Hot water systems
a. Electric
Cap: 50 gallons
8. FloorTypes (1523.0 sgft.) Insulation Area
EF: 0.950
a. Slab -On -Grade Edge Insulation R=0.0 1523.00 ft2
b.-Conservation features
b. N/A R= ft2
None
c. N/A R= ft2.
15. Credits
Pstat
Glass/Floor Area: 0.112 .Total Proposed Modified Loads: 48.41
� A �+L+
Total Baseline Loads: 49.18
/'1�7�7
hereby certify that the plans and specifications covered by
Review of the plans and
�T ST,g?�•
this calculation are in compliance with the Florida Energy
Code.
specifications covered by this
calculation indicates compliance
��
with the Florida Energy Code.
PREPARED BY: j°�"'�`-�
Before construction is completed
d
DATE: ® a - 2 D 1i
this building will be inspected for
compliance with Section 553.908
;' a
hereby certify that this building, as designed, is in compliance
Florida Statutes.
G+Ob
with the Florida Ener od .
'WE
OWNER/AG N
BUILDING, OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires, an Air�Barrier and Insulation Inspection Checklist in accordance with R402.44.1 and this project requires an
envelope leakage test report with envelope. leakage: no greater.than 7.00 ACH50 (R402.4.1:2).
FILE.Copy
3/26/2018 1:20 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 6
FORM R405-2017
PROJECT
Title: Evon Residence
Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 1523
Lot #
Owner Name:
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: 'No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
Permit Office:
Cross Ventilation: No
County:
St Lucie
Jurisdiction:
Whole House Fan: No
City, State,
Zip:
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
j
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer Degree
Days Moisture
Range
FL, Fort Pierce FL —FORT PIERCE
41
91
70
75
526
44
Medium
BLOCKS
Number Name
Area
Volume
1 Entire House "
1523
14517.3
SPACES
Number Name
Area
Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1 WIC 2
42
390.6 No
0
1
Yes
Yes
Yes
2 WC
18
167.4 No
0
1
No
Yes
Yes
3 MASTER BATH
140
1302 No
0
1
Yes
Yes
Yes
4 MASTER BEDROO
199
1850.7 No
2
1
1
Yes
Yes
Yes
5 BREAKFAST
61
567.3 No
0
1
Yes
Yes
Yes
6 KITCHEN
145
1348.5 Yes
0
1
No
Yes
Yes
7 LAUNDRY
51
474.3 No
0
1
Yes
Yes
Yes
8 DINING ROOM
203
1887.9 No
4
1
Yes
Yes
Yes
9 LIVING ROOM
314
2920.2 No
4
1
Yes
Yes
Yes
10 BEDROOM 3
160
1488 No
1
1
1
Yes
Yes
Yes
11 BATH 2
46
427.8 No
0
1
Yes
Yes
Yes
12 BEDROOM 2
155
1441.5 No
1
1
1
Yes
Yes
Yes
13 PWDR
27
251.1 No
0
1
No
Yes
Yes
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
WIC 2 6.3 ft 0
42.2 ft'
0 0
1
2 Slab -On -Grade Edge Insulatio
WC 1 ft 0
17.8 ftz
0 0
1
3 Slab -On -Grade Edge Insulatio
MASTER BATH 23.3 ft 0
139.6 ftZ
0 0
1
4 Slab -On -Grade Edge Insulatio
MASTER
BEDRO 13 ft 0
199.3 ftZ
___-
0 0
1
3/26/2018 1:20 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 6
F(1RM RAn.c;-gn17
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
5 Slab -On -Grade Edge Insulatio
BREAKFAST 7.3 ft
0
61.1 ft2
0
0
1
6 Slab -On -Grade Edge Insulatio
KITCHEN 1 ft
0
145 ft2.
0
0.
.1
7 Slab -On -Grade Edge Insulatio
LAUNDRY 7.3 ft
0
51.3 ft2
0
0
1
8 Slab -On -Grade Edge Insulatio
DINING ROOM 14.3 ft
0
203.2 ft2
0
0
1
9 Slab -On -Grade Edge Insulatio
LIVING ROOM 16.7 ft
0
314.3 ft2
____
0
0
1
10SIab-On-Grade Edge Insulatio
BEDROOM 3 29.3 ft
0
160.2 ft2'
0
0
1
11Slab-On-Grade Edge Insulatio
BATH 2 5.3 ft
0
46.2 ft2
0
0
1
12SIab-On-Grade Edge Insulatio
BEDROOM 2 26 ft
0
154.8 ft2
0
0
1
13SIab-On-Grade Edge Insulatio
'PWDR 1 ft
0
26.9 ft2
___
0
0
1
ROOF
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
V
# Type Materials Area
Area
Color
Absor. Tested
Tested
Insul.
(deg)-
1 Gable or Shed Composition shingles 1692 f12
326 ft2
Medium
0.9
No
0.9
No
0
22.6
ATTIC
V
# Type
Ventilation Vent
Ratio (1
in)
Area
RBS
IRCC
1 Full attic
Vented
300
1523-ft2•
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1 Under Attic (Vented)
WIC 2
30
Blown
42 ft2
0.1
Wood
2 Under Attic (Vented)
WC
30
Blown
18 ft2
0.1
Wood
3 Under Attic (Vented)
MASTER BATH
30
Blown
140 ft2
0.1
Wood
4 Under Attic (Vented)
MASTER BEDRO
30
Blown
199 ft2
0.1
Wood
5 Under Attic (Vented)
BREAKFAST
30
Blown
61 ft2
0.1
Wood
6 Under Attic (Vented)
KITCHEN
30
Blown
145 ft2
0.1
Wood
7 Under Attic (Vented)
LAUNDRY
30
Blown
51 ft2
0.1
Wood
8 Under Attic (Vented)
DINING ROOM
30
Blown.
203 ft2
0.1
Wood
9 Under Attic (Vented)
LIVING ROOM
30
Blown
314 ft2
0.1
Wood
10 Under Attic (Vented)
BEDROOM 3
30
Blown
160 ft2
0.1
Wood
11 Under Attic.(Vented)
BATH 2
30
Blown
46 ft2
0.1
Wood
12 Under Attic (Vented)
BEDROOM 2
30
Blown
155 ft2
0.1
Wood
13 Under Attic (Vented)
PWDR
30
Blown
27 ft2
0.1
Wood
3/26/2018 1:20 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software .
Page 3 of 6
FORM R405-2017
WALLS
Adjacent
C11 avity
Width
Height
Sheathing
Framing Solar
Below
Space
INAI Type
1 .
W
Exterior
Concrete Block - Int Insul WIC 2
4.1
6
4
9, 4
59.1 ft2
0
0 0.8
0
_ 2
S
Exterior
Concrete Block - Int InsWASTER BA
4.1
12
0
91 4
112.0 ft2
0
0 0.8
0
_ 3
W,
Exterior
Concrete Block - Int InsiNASTER BA
4.1
11•
4
9 4
105.8 ft2
0
0 0.8
0
4
S
Exterior
. Concrete Block" Int InsiMASTER BE;
4.1
13
0
9. 4
121.3 ft2
0
0 0.8
0
5
W
Exterior
Concrete Block - Int InsEIREAKFAST
4.1
7
4 . '
9' 4
68A ft2
-0
0 0.8
0
_ 6
S
Exterior
. Concrete Block :Int InsuLAUNDRY
4.1
7
4
9 4
68.4 ft2
0
0 0.8
0
7
E
Garage
Frame - Wood LAUNDRY
13
7
0
9 4
65.3 ft2
0
0.25 0.8
0
N
Exterior
Concrete Block - Int InsUINING ROO
4.1
4
0
9 4
37.3 ft2
0
0 0.8
0
_8
_ 9.
E
Exterior
Concrete Block - Int Ins9INING ROO
4.1
10
,4
9 4
96A ft2
0
0 0.8
0
_ 10
E
Garage
Frame - Wood DINING ROO
. 13
6
8
9 4.
62.2 ft2
0 ' .
0.25 0.8
0
11
E
Exterior
Concrete Block - Int InSWVING ROO
4.1
4
0
9 4
37.3 ft2
0
0 0.8
0
_12
W
Exterior_
Concrete Block- Int InsU1VING ROO
4.1
12
8 .
9, 4
118.2 ft2
0
0 0.8
0
13
N'
Exterior
Concrete Block- Int Ins8IEDROOM 3
4.1
12
0
9 4
112.0 ft2
0
0 0.8
0
_ 14
E
Exterior
. Concrete Block - Int InsBIEDROOM 3
4.1
14
0
9 4
130.7 ft2
0
0 0.8
0
15
S
Exterior
Concrete Block - Int InsBIEDROOM 3
4.1
3
4 .
9 4
31.1 ft2
0
0 0.8
0
_
_ 16
N
Exterior
Concrete Block - Int Insul BATH 2
4.1
5
4
9 4
49:8 ft2
0
0 0.8
0.
17
N
Exterior
Concrete Block - Int InsBEDROOM 2
4.1
14
4
9 4
133.8 ft2
0
0 0.8
0.
18
W
Exterior
Concrete Block- Int InsBIEDROOM 2
4.1
11
8 :-
9 4
108.9 ft2
- 0
0 0.8
0
19
E
Garage
Frame - Wood PWDR
13
7
,4
9 4 -
68.4 ft2
0
0.25 0.8
0
DOORS
#
Omt
Door Type Space
Storms
U-Value
Width_
Height
Area
Ft
In
Ft In
1
E
Insulated LIVING ROO
None
.6
3
6 8
20 ft?
2
E
Wood DINING ROO
None,
.46
3
6 8
20 ft2
WINDOWS-
Orientation shown is the entered, Proposed orientation.
Wall.'
Overhang .
V
#
Omt ID
Frame. Panes NFRC U-Factor
SHGC
Imp.
Area.
Depth
Separation
.IntShade
Screening
1
W 3
Vinyl Low-E Double Yes
0.34.
0.32
N
16.0 ft2
1 ft 4 in
1 ft 6 in
Drapes/blinds
None
2
S 4
Vinyl Low-E Double Yes .
0.34
0.32
N
30.0 ft2
1 ft 4 in
0 ft 0 in
Drapes/blinds
None
3
W 5
Vinyl Low=E Double Yes
0.34
0.32
N
20.1 ft2
8 ft 0 in
0 ft 4 in
Drapes/blinds
None
4
E 9'
Vinyl Low-E Double Yes
0.34
0.32
N
30.0 ft2
1 ft 4 in
. 5 ft 0 in
Drapes/blinds
None
5
W 12
Vinyl Low-E Double Yes
0.34
0.32
N
.30.0.ft2
8 ft 0 in
0 ft 4 in
Drapes/blinds
None
6
E 14
Vinyl Low-E Double. Yes
0.34
0.32
N
20.0 ft2
1 ft 4 in
5 ft 0 in
Drapes/blinds
None
7
N 16
Vinyl . 'Low-E Double Yes
0.34
0.32
N
9.0 ft2
1-ft 4 in
1 ft 6 in
Drapes/blinds
None
8
W 18
Vinyl Low-E Double Yes
0.34
0.32
N
20.0 ft2
1 ft 4 in
0 ft 4 in
Drapes/blinds
None
Page 4 of 6
F:oRm.R4f15-gf117
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
497 ft2
497 ft2
66.34 ft 9.33 ft 0
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse
Proposed ACH(50)
.000414
1693.7 9Z98 174.86 .302 7
HEATING SYSTEM
#
System.Type
Subtype
Efficiency Capacity Block
Ducts
1
Electric Heat Pump/
Split
HSPF:8.5 34.4 kBtu/hr 1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit/
Split
SEER: 15 34.4 kBtu/hr cfm 0.7 1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Electric None
Garage
0.95 50 gal 60.9 gal. 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None
None
ft2
DUCTS
v #
-- Supply ---
Location R-Value Area
--- Return ---- Air CFM 25 CFM25
Location Area Leakage Type Handler 'TOT OUT QN RLF
HVAC #
Heat Cool
1
Attic 6 623 ft2
Attic
623 ft2 Default Leakage Garage (Default) (Default)
1 1
3/26/2018 1:20 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 6
Gnr�nn r��nG_�n��
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Coolin [ ]Jan
[ ]
[j ]]Feb
[[ ]]Mar
A r
May
[X] Jun.
[X] Jul
Au
[X]
Se
Oct
Nov
Dec
Heating Janl
Feb
[X] Mar
Apr
May
J Jun.
[ ] JUI
Aug
IXI
]
Sep
Oct
Xi Nov
Venting [ ]Jan
[ ]Feb
l
[X Mar
L 1 Jun
[ ]Jul
Aug
j
Sep
Oct
Dec
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
-66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
3/26/2018 1:20 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 6 of 6
FORM R405-2017
ENERGY
PERFORMANCE LEVEL (EPL)
'
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPerformance Index, the more efficient the home.
FL,
1. New construction or existing
New (From Plans) 9. Wall Types Insulation
Area
2. Single family or multiple family
Single-family a. Concrete Block - Int Insul, Exterior R=4.1
1390.70 ft2
b. Frame - Wood, Adjacent R=13.0
196.00 ft'
3. Number of units, if multiple family
1 c. N/A R=
ft'
4. Number of Bedrooms
3 d. N/A R=
ft'
10. Ceiling Types Insulation
Area
5. Is this a worst case?
No a. Under Attic (Vented) R=30.0
1523.00 ft'
6. Conditioned floor area (ft')
1523 b. N/A R=
ft'
c. N/A R=
ft'
7. Windows- Description
Area
11. Ducts
R ft'
a. U=Factor: Dbl, U=0.34
175.10 ft' a. Sup: Attic, Ret: Attic, AH: Garage
6 - 623
SHGC: SHGC=0.32
b. U-Factor: N/A
ft'
SHGC:
12. Cooling systems kBtu/hr
Efficiency
c. U-Factor: N/A
ft' a. Central Unit 34.4 ' SEER:15.00
SHGC:
d. U-Factor: N/A
ft' 13. Heating systems kBtu/hr
Efficiency
SHGC:
a. Electric Heat Pump 34.4
HSPF:8.50
Area Weighted Average Overhang Depth:
3.241 ft.
Area Weighted Average SHGC:
0.320
8. Floor Types Insulation Area 14. Hot water systems
Cap:
50 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1523.00 ft 2 a. Electric
EF: 0.95
b. N/A R=
ft'
b. Conservation features
c. N/A R=
ft=
None
15. Credits
Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code; Energy Conservation, if not DEFAULT.
3/26/2018 1:21 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1
4.
• Load Short Form Job: : 1523 Sq. Ft.
Date: Mar 01; 2018
Entire House By: Steven Ferrell
Project Inf• •
For: Evon Residende, Design West Associates
Design Information
Htg
Clg
Infiltration
Outside db .(°F)
42
93
Method
Simplified
Inside db (°F)
70
.75
Construction quality
Average
Design TD (°F)
28
18
Fireplaces ..
0
Daily range.
-
M
Inside humidity (%)
50
50
Moisture difference (gr/lb)
. 23.:
44
HEATING EQUIPMENT
COOLING EQUIPMENT
Make Carrier
Make Carrier
Trade CARRIER AIR CONDITIONING
Trade CARRIER AIR CONDITIONING
Model CH14NB0360000130
Cond CH14NBO360000BO
AHRI ref 9162516.
Coil FX4DNB037L
AHRI ref 9162516
Efficiency 8.5 HSPF
Efficiency, 12.5 EER, 15 SEER
Heating input
Sensible cooling
24080 Btuh
Heating output
33800
Btuh @ 4.7°F
Latent cooling
10320 Btuh
Temperature rise,
29
°F
Total cooling
34400 Btuh
Actual air flow
1050
cfm
Actual air flow
1050 . cfm
Air flow factor
0.065
cfm/Btuh
Air flow factor
0.043 cfm/Btuh
Static pressure
0.50
in H2O
Static pressure
-0.50 in H2O
Space thermostat
Load sensible heat ratio
0.84
Capacity balance point = 28 °F
Backup:
Input = 6 kW Output = 20052 Btuh.
100
AFUE
ROOM NAME Area Htg load Clg load, Htg AVF Clg AVF
(ft2) (Btuh) I (Btuh) (cfm) (cfm)
WIC 2 42 706 349 39 15
WC 18 21 38 1 2
MASTER BATH 140 2717 2253 149 96
MASTER BEDROOM 199 1829 1902 101 81
BREAKFAST 61 999 .. 1228 : 55 53
KITCHEN 145 167 1783 9 76
LAUNDRY 51, 821 1141 45 49
DINING ROOM 203 1972 3902 108 167
LIVING ROOM 314 2697 5536 148 237
BEDROOM 3 160 3397 2915 187 125
BATH 2 46 682 408 38' 17
BEDROOM 2 155 30.44 2897 168 124
PWDR 27 31 1 2 8
Calculations approved b AC�A t LEe u en s mo Manual J 8th Ed.
PP Y q
J. 2018-Mar-26 13:06:15
T!r WirightSoftW Comfort Builder by Wri htsoft 18.0.04 RSU18350 Page 1
...\Evon Residence\4-Wrightsoft\Evon Residence.rup Calc = MJ8 Front Door faces: E
Entire House d
1523
19081
24533
1050
1050
Other equip loads
0
0
Equip. @ 0.98 RSM
24042
Latent cooling
4815
TP1TA1 c
4
4nFn
inGn
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
`wrightsoft- . 2018-Mar-26 1306:15
,„ ;A' Comfort Builder by Wrightsoft 18.0.04 RSU18350 Page 2
-CK ...\Evon Residence\4-Wrightsoft\Evon Residence.rup Calc = MJ8 Front Door faces: E