HomeMy WebLinkAboutEvaluation Report; Certain Teed Asphalt Roof Shingles\1 TRINITY FVALl1ATION REPORT EXTERIOR RESEARCH & DESIGN, I.I.C. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 ERD OXFORD, CT 06478 (203)262-9245 CertainTeed Corporation 20 Moores Road Malvern, PA 19355 (610)651-5847 Evaluation Report 353z.U9.U5-1(13 FL5444-R12 Date of Issuance:09/22/2005 Revision 13: 09/05/2027 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: CertainTeed Asphalt Roof Shingles. LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 2507.2.7.1 / R90S.2.6.1 CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity IERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its' distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 12. Prepared by: zxo'o �� Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 1111tlrznn. — :� •P qt The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 09/05/2017. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Trinity lERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. TrinitylERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. (Ti:�IINITYIERD 6.22 PATRIOT -: LOW AND STANDARD SLOPE STEEP SLOPE Use POUR nails for every full shingle located ac shown below. lanl i ������i'zrr G-118'� __ (25am) ` (`,.;l-► (155 mmj (333av) (1? =1 t333anj Use FOUR nails and four spas (A asphalt roofing cement for every full shingle as shown below: Asphalt roofing collenl meeling AtiRI D4586 'fy13e 11 Li suggested. Apply 1 ° (25 nuu) spots of asphalt roofing cenicni a:s shovvi3. CAUTION: Excessive use of roofing cement can curse shingles to blister. ttmm) I r_. Jaeotlnp Cement M134M 47mnn}'I 6.12.1 Hip & Ridge for Patriot—: Refer to instructions herein for Cedar Crest—, Cedar Crest— IR, Shadow Ridge—, NorthGate or Shangle Ridge*" hip and ridge shingles. 7. LABELING: 7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1. B. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3 CIA requirements. 10. QUALITY ASSURANCEENTITY: UL LLC—QUA9625; (414) 248-6409; karen.buchmann@us.ul.Com - END OF EVALUATION REPORT - Exterior Research and Design, I.I.C. Evaluation Report 3532.09.0S-R33 Certificate ofAuthori:ation #9503 CH EDITION (2017) FBC NON-HVHZ EVALUATION FL5444-R12 CertalnTeed Asphalt Roof shingles; (610) 651-5847 Revision 13: 09/05/2017 Page 12 of 12 6.10.1 Hip & Ridge for Hatteras—:, 6.10.1.1 Option 1: Accessory for Hatteras I t y I 2 3 Figure 13-14. 18 tbrae pMw snits -separate to make 54 Xa4erasAacessory shingles. 6.10.1.2 Option 2: Cut Hatteras Shingles .(230 min) I -- [�hlngle LSh�iangple 4Rmm)Cap CapapShingle Shingle`,Z�mm) Ms"X211erequvasnails SIX emir (Avo Instell9d oresMMY shia9nm). aMul as i. Figure I1-3: Use FIVE nails for every Higganit Slate sbino.. ERD Y—� 9'--`�—Y 9' R7omm) We.W Rb�) - InOvan) RSImm1 R9'mm) MiamiDale reQeuae t'p5nm1 R�el�+�+) 31%rw7a{Nrone3s � 1 �_ InMaAetl over tenor adoulestlawni �— R00%g Ceme . 'Figure 11.-3A: Use MT nails and eigbt spots ofaspbidt roofing came# under eacb tab comer. "CAUTION: Excessive use of tooling cement can cause shingles to blister. 6.11.1 Hip & Ridge for Highland Slate'"', Highland Slater"" IR: Refer to instructions herein for Cedar Crest•"', Cedar CreStTM IR or Shangle Ridge'"" hip and ridge shingles. Exterior Research and Design, U.C. Evaluation Report 3532.09.05-R13 Certificate of Authorization #9503 .6t" EDITION (2017) FBC NON,HVHZ EVALUATION FL5444-R12 CertainTeed Asphalt Roof Shingles; (610) 651-5847 Revision 13: 09/05/2017 Page 11 of 12 _D r,� TrtIMn 'J erg ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: CertainTeed Asphalt Roof Shingles, as produced by CertainTeed Corporation, have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code and 6th Edition (2027) Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1,'R905.2.6.1 Wind Resistance ASTM D7158 2011 3. REFERENCES: Knfitf Examination Reference Date UL (TST 1740) ASTM D3161 94NK9632 05/15/1998 UL (TST 1740) ASTM D3161 99NK26506 11/23/1999 UL (TST 1740) ASTM D3161 03CA12702 05/27/2003 UL (TST 1740) ASTIVID3161 03CA12702 06/16/2003 UL (TST 1740) ASTM D3161 03NK29847 10/03/2003 UL (TST 1740) ASTM D3161 04CA11329 05/24/2004 UL (TST 1740) ASTM D3161 04CA32986 12/03/2004 UL (TST 1740) ASTM D3161 05NK07049 04/15/2005 UL (TST 1740) ASTM D3161 05NK16778 05/12/2005 UL (TST 1740) ASTM D3161 OSCA16778 05/12/2005 UL (TST 1740) ASTM D3161 05NK14836 05/22/2005 UL (TST 1740) ASTM D3161 OSNK22800 06/22/2005 UL (TST 1740) ASTM D3462 R684 09/21/2005 UL (TST 1740) ASTM D7158 OSNK08037 06/28/2006 UL (TST 1740) ASTM D3161 & D3462 09CA28873 07/23/2009 UL (TST 1740) ASTM D3462 IOCA41303 10/07/2010 UL (TST 1740) ASTM D3161 10CA41303 10/08/2010 UL (TST 1740) ASTM D7158 • IOCA41303 10/27/2010 UL (TST 1740) ASTM D3161 & D3462 IOCA44960 11/11/2010 UL LLC (TST 9628) ASTM D3161, D3462 & D7158 13CA32897 11/21/2013. UL LLC (TST 9628) ASTM D3161, D3462 TFWZ.R684 04/22/2014 UL LLC (TST 9628) ASTM D7158 TGAH.R684 04/22/2014 UL LLC (TST 9628) ASTM D3161 & D3462 4786334434 09/16/2014 UL LLC (TST 9628) ASTM D3161 & D3462 4786570826 02/12/2015 UL LLC (TST 9628) ASTM D3161, D3462 & D7158 4786570717 12/16/2015 UL LLC (TST 9628) ASTM D3161 & D3462 4787195678 02/09/2016 UL LLC (TST 9628) ASTM D3161, D3462 & D7158 4787380356 10/26/2016 ULLLC (TST 9628) ASTM D3462 4787380357 10/13/2016 ULLLC (TST 9628) ASTM D7158 4787380357 11/08/2016 UL LLC (TST 9628) ASTM D3161 4787380357 11/09/2016 UL LLC (TST 9628) ASTM D3161, D3462 & D7158 4787586427 01/25/2017 UL LLC (QUA 9625) Quality Control Service Confirmation Exp. 03/09/2020 Exterior Research and Design, U.C. Evaluation Report 3532.09.05-1113 Certificate of Authorisation #9503 6Tn EDITION (2017) FBC NON-HVHZ EVALUATION F1.5444-1112 CertainTeed Asphalt Roof Shingles; (610) 651-S847 Revision 13: 09/05/2017 Page 2 of 12 QOTRI'NITYIERD 4. PRODUCT DESCRIPTION: 4.1 CT20TM, XI" 25, Xrm 30 and Xr30 IR are fiberglass reinforced, 3-tab asphalt roof shingles. 4.2 Arcadia'"', Belmont®, Belmont® IR, Carriage House Shangle°, Grand Manor Shangle°, Landmark', Landmark'"' IR, Landmark'" Pro, Landmark'"" Premium, Landmark"" TL, Landmark' Solaris and Landmark'"' Solaris IR are fiberglass reinforced, laminated asphalt roof shingles. 4.3 NorthGate" is a fiberglass reinforced, laminated, SBS modified bitumen roof shingle. 4.4 Presidential Shake"", Presidential Shakem IR, Presidential Shake TL'"' and Presidential Solarism are fiberglass reinforced, architectural asphalt roof shingles. 4.5 HatterasTM, Highland Slatem and Highland Slate'"" IR are fiberglass reinforced, 4-tab asphalt roof shingles. 4.6 Patriot'' is a fiberglass reinforced asphalt roof strip -shingle (with no cut-outs) providing a laminated appearance through an intermittent shadow line with contrasting blend drops for color definition. 4.7 Presidential Accessory, Accessory for Hatteras, Shangle Ridge'"', Shadow Ridge'", Cedar Crest'"", Cedar Crestm IR, NorthGate Ridge and NorthGate Accessory are fiberglass reinforced accessory shingles for hip and ridge installation. 4.8 Any of the above listed shingles may be produced in AR (algae resistant) versions. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use within FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Wind Classification: 5.4.1 All shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for us in all wind zones UP to VaSd = 150 mph (V it = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 Presidential Accessory, Accessory,for Hatteras, Shangle. Ridge, Shadow Ridge, Cedar Crest, NorthGate Ridge and NorthGate Accessory hip & ridge shingles have been evaluated in accordance with ASTM D3161, Class F. All except NorthGate Ridge and NorthGate Accessory require use of BASF Sonolastic NP 1 adhesive or Henkel PL® Polyurethane Roof & Flashing Sealant, applied as specified in manufacturer's application instructions, for use in wind zones up to VaSd =150 mph (V It =194 mph). 5.4.3 Classification by ASTM D7258 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.3.1 Analysis in accordance with ASTM D71SS indicates the measured uplift resistance (RT) for the CertainTeed asphalt Roof shingles listed in Section 4.1 through 4.6 (except Presidential Solaris') exceeds the calculated' uplift force (FT) at a maximum design wind speed Of VaSd = 150 mph (Vast = 194 mph) for residential buildings located in Exposure D conditions with no topographical variations (flat terrain) having a mean roof height less than or equal to 60 feet. The shingles are permissible under Code for installation in these conditions using the installation procedures detailed in this Evaluation Report and CertainTeed minimum requirements, subject to minimum codified fastening requirements established within any local jurisdiction, which shall take precedence. 5.5 All products in the roof assembly shall have quality assurance audits in accordance with F.A.C. Rule 614320- 3. Exterior Research and Design, I.I.C. Evaluation Report 3532.09.0S-R13 Certificate afAuthorization #9503 6t" EDITION (2017) FBC NON-HVHZ EVALUATION FL5444-R12 CertainTeed Asphalt Roof Shingles; (610) 651-5947 Revision 13: 09/05/2017 Page 3 of 12 6. INSTALLATION: 6.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle manufacturer's minimum requirements. 6.1.1 Underlayment shall be acceptable to CertainTeed Corporation and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.2 Installation of asphalt shingles shall comply with the CertainTeed Corporation current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or Section R905.2.6 and the minimum requirements herein. 6.2.1 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.2 Where the roof slope exceeds 21 units vertical in 12 units horizontal, use the "Steep Slope" directions. 6.3 CertainTeed asphalt shingles are acceptable for use in reroof (tear -off) or recover applications, subject to the limitations set forth in FBC Section 1511 or R908 and CertainTeed published installation instructions. 6.4 ENGLISH 12" 12" 12" (305 Imm 305 mm)(305 mm)- 1 "(2Selant 1"(25mmJ , 5 s/s" (145 mm) 5 r12 ­ for Norwood Pant METRIC 131/8" . 131/e" 131/e" 1" (25 mm) — Sealant lant 1"(25 mm) ►{ 6 t1C — — — — — — Figure 113: Usefournailsfor avvJidlshingle. STEEP SLOPE Use four nails and six spots of asphalt roofing cement* for every full shingle (Figure 11-4). Asphalt roofing cement meeting ASTM D4586 Type II is suggested. I " Roofing Cement Apply 1"(25 an) spots of asphalt roofing cement under each tab corner. Figure 11-4: csefoarnails and stz spots o, faspbaU coment on steep slopes. *cAUTION: Excessive use of roofing cement can cause shingles to blister. 6.4.1 Hip & Ridge for CT20'", XT'" 25, XT'"" 30, XT1" 30 IR: Cut Shingles 1" .II+2" (50 mm) Remove (25 mm)p� III l�l I 12" (305 mm) II II tl _ (12125mm) Cap Cap Cap 305Imm) �i�R�an Shingle Shingle Shingle I Figure 11-24 Cut tabs, then trim back to make cap sbingigless (Bnglisb dimensions shown). Figure II-25: installation ofcwps along the hips and ridges. 6.4.1.1 For ASTM D3161, Class F performance use BASF "Sonolastic° NP11""' adhesive or Henkel "PL® Polyurethane Roof & Flashing Sealant", in accordance with CertainTeed requirements. Exterior Research and Design,LtC. Evaluation Report 3532.09.05-R13 Certificate afAuthorization a9503 CH EDITION (2017) FBC NON-HVHZ EVALUATION F1.5444-1112 CertainTeed Asphalt Roof Shingles; (610) 651-5847 Revision 13: 09/05/2017 Page 4 of 12 T'TpuNITYIERD Use two (2), minimum 1%-inch long fasteners per shingle. For the starter shingle, place fastener 1-inch from each side edge and about 2-inch up from the starter shingle's exposed butt edge, ensuring minimum -inch embedment into the deck, or full penetration through the deck. For each full Cedar Crest shingle, place fasteners 8-5/8-inch up from its exposed butt edge and 1-inch from each side edge. For ASTM D3161, Class F performance use BASF "Sonolastic® NP1' " adhesive or Henkel "PL® Polyurethane Roof & Flashing Sealant", in accordance with CertainTeed requirements, to hand -seal Cedar Crest shingles. Apply NP 1 or PL adhesive from the middle of the shingle's raised overlay on the top piece and extending approximately 4-inch along the sides of the headlap along a line % to 1-inch from each side of the shingle's headlap. Immediately align and apply the overlying shingle, gently pressing tab sides into the adhesive, and install nails. To secure the other side, apply a 1-inch diameter spot of NP 1 or PL adhesive between the shingle layers. Hand -sealing adhesive 4" 1/4" LL2 1 314" --► I+- 1" Dab of asphalt cement between shingle layers Exterior Research and Design,LLC. Evaluation Report 3532.09.05-R13 Certificate ofAutharizat/on 09503 CH EDITION (2017) FBC NON-HVHZ EVALUATION FL5444-1112 CertainTeed,Asphalt Roof Shingles; (510) 651-5847 Revision 13: 09/05/2017 Page 5 of 12 6.6 Low and Standard Slope (2:12 to 21:12): Use FIVE nails for every full Belmont shingle, located as shown below. o Add tiowl was 6W t� t Ste Steep Slope (greater than 21:12): Use SEVEN nails and EIGHT spots of asphalt roofing cement" for every full Belmont shingle. Apply asphalt roofing cement 1" (25mm) from edge of shingle. See below. Asphalt roofing cement meeting ASTM D4586 Type 11 is suggested. P M rU,$ �—,F,aoGnq C17Mfd 6.6.1 Hip & Ridge for Belmont® or Belmont" IR: 6.6.1.1 Option 1: For Belmont®, refer to instructions herein for Cedar Crest— or Cedar Crest" IR hip and ridge shingles. For Belmont® IR, refer to instructions herein for Cedar Crest- IR hip and ridge shingles. 6.6.1.2 Option 2: For Belmont®: Shangle® Ridge 18 Exposure Remove tape 12"tfrom the right side and Casten " 8 SECOND Fasten the f Remove left side 85f8. RIGHT FIRST This rape FLEFT �:==A Figure 17-19:1nsfaHation ofSbangle® Ridge sbingles Figure 17-1& Sbanglea Ridge. on baps and ridges. 6.6.1.3 For ASTM D3161, Class F performance use BASF "Sonolastics NPi" adhesive or Henkel "PL® Polyurethane Roof & Flashing Sealant", in accordance with CertainTeed requirements. Exterior Research and Design,LLC. Evaluation Report 3532.09.05-1113 Certificate of Authorization #9503 67N EDITION (2017) FBC NON-HVHZ EVALUATION FL5444-R12 CertainTeed Asphalt Roof Shingles; (610) 651-5847 Revision 13: 09/05/2017 Page 6 of 12 0 6.7 6.7.1 6.8 Q0T1mNrrYjERD CARRIAGE HOUSE SHANGLE® AND GRAND MANOR SHANGLE®: . STEEP SLOPE LOW AND STANDARD SLOPE Use five nails for every full Shangle. '( fp 1—(25 mm) i (25 mm) 5 855, (16 mm) ( I m) Figure 17-4. Usef m na(lc jorereryjdl GrandM4—Sbmrgfe, Carriage muse Shangle, or C"Iennial Slale. Use seven nails and three spots of asphalt roofing cement for every full Grand Manor Shangle. Use five nails and three spots of asphalt roofing cement for every full Carriage Rouse Shangle and Centennial Sate. Apply asphalt roofing cement 1 (25 mm) from edge of shingle (Figure 17.5). Asphalt roofing cement meeting ASfM D4586 Type 11 Is suggested, 1 1/2" (38 aim) 1„ or less -�{ 1•• 1+-(25mm) I (25 mm) 5/81,` 8 5/8„ (16 aim); II 1220 L (25 nM) Rooting Gmurl Figure 17-5. when installing ('rand Manor Shangle; on sleep slopes, use saex nails and lbree spots ofaspball roofing cement. Hip & Ridge for Carriage House Shangle® and Grand Manor Shangle: Refer to instructions herein for Shangle® Ridge hip and ridge shingles 7 7. LANDMARK,',"", LANDMARKTe".IR, LANDMARK*"" PRO,'LANDMARK-" PREMIUM, LANDMARK'"' TL, LANDNiARKr"" SOLARIS,'UINDMARKru'SOLARIS IR,.NORTHGATE: LOW AND STANDARD SLOPE METRIC DIMENSIONS 12 14314" 12" �--(305 mm)-► —(375 mm)(305 mm)-►� Iw 1 ' (25 mm) Release Tape 1" (25 mm) wl 11/2„ NailahleT Area Et� utnrrnwnn M NorthGate: QW' 13" 1392" �—(343 mai)-► •-(330 mm)� �-(343 mm)� — 1 -1"(25 mm) 1" (25 mm)—I �- Figum 1.3-4. Usefour nailsfor ereq•jrll sbingle. AVE NAM it 14 Y4' 2' AREA f. (3e5 mm) -+ *--- (375 mail - ► . (305 mm) r 6arrg UrAs �1 Upper-1Ine V (25aim)- �- ¢ P (25 aim) .ewer rW Ire Raug arm torlow mM swdud dopes (tram 2:12 to 21:12) Nal W'Woen upper✓! 17 , lies as shown above. Exterior Research and Design, U.C. Evaluation Report 3532.09.05-R13 Certificate of Authorization n9503 67N EDITION (2017) FBC NON-HVHZ EVALUATION FL5444 R12 CertainTeed Asphalt Roof Shingles; (610) 651-5847 Revision 13: 09/05/2017 Page 7 of 12 QOTRINITYIERD STEEP SLOPE Ilse six nails and four spots of asphalt roofing cement for every full LANDMARK TL laminated shingle. See below. Asphalt roofing cement should meet ASTH D4586 7ypc li. Apply 1" spots of asphalt rooting cement uncle }.-13Vz^ 13rrim) --13112'L each corner and .n about 12 to 13 in from each edge. I (343 mm') (330 mm) I (343 mm) METRIC DIMENSIONS -• I61(25mm) I 1 1"(25mm) 12 143/4—12 I If VA 1, (305mm) (375mm) (305mm) (25mm)I -- 7(25mm) ROafing'Cert�M +1'(25Min) Relea Tape 1"(25mm) �- vi rocs )r Steep Figure 13 3: Use slx Halls andfour spots of , asphalt roofrngcomeat on steep slopae (25 mm) -- — — (25 mm; Rooting Cement. NorthGate: STEEP 12' 14.3W 12' SLOPE 1-.4305 mml- l•--t375 n,1+4305 mmY►j Mm) ( DeneT,,1 t � 11'(25 �.-_.- !� ill •:I I I' t - t L-H-1 Roofing Cernent Nailing areas for steep dopes (greater than 21:12) and "Stor ilAalling" Nail between lower 2 nal lines as shown above. 6.8.1 Hip & Ridge for Landmark'"' Landmark'" IR Landmark*" Pro Landmark'"" Premium, Landmark"" TL, Landmark- Solaris Landmark'"' Solaris IR, NorthGate: 6.8.1.1 Option 1: Shadow Ridge'" or NothGate Accessory 12' (305mm) 415/1(250mm) --�-415/tg 6" 0146" (125mm) I .(125mm) (150mm) (150mm) f Notch for Notch for Cantering Centering 131/4" I (305mm) NLCtapfor for Alignmant� (337mm);the Notches forAlignmird� 75/3° dge of the Previous p Edge of the Previous (195mm} (125mm)Exposure(11 80mm) L —i Capfor55A(141mm)Exposuie It— English Dimension Metric Dimension Shadow Ridge•" Shadow Ridge'" Exterior Research and Design, I.I.C. Evaluation Report 3532.09.05-R13 Certificate ofAuthorization N9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL5444-1112 CertainTeed Asphalt Roof Shingles; (610) 651-5847 Revision 13: 09/05/2017 Page 8 of 12 9 9 27= +--i1w,1161ill"71-20--z") 131/8" Geared Pj=b _ 168 mm)II 168 mm 1 13 i!A` ` ? Centedng sa (337 mm} alga th / Notch notches to top 7 W 331/4° R *4 01, (184 rM) (37 mm) \aign theseJe 7518 p>tr/ ous tout" notches to top ( mm) of edge of previous course. NorthGate Ridge NorthGate Accessory 12' (305mm) Laying Notch I I 5. (125mm) I I I Ir"Ifr Figure 13-20.- Use layingnotcbes to center sbipgles on hips and rktges, and to hicate the correct exposure. 6.8.1.2 For ASTM D3161, Class F performance use BASF "Sonolastic® N121 " adhesive or Henkel "121.11 Polyurethane Roof & Flashing Sealant", in accordance with CertainTeed requirements. 6.8.1.3 Option 2: Refer to instructions herein for Cedar Crest'", Cedar Crest— IR hip and ridge shingles. Exterior Research and Design, U.C. Evaluation Report 3532.09.05-R33 Certificate ofAuthorization a9503 6Te EDITION (2017) FBC NON-HVHZ EVALUATION FL5444-R12 CertainTeed Asphalt Roof Shingles; (510) 651-5947 Revision 13: 09/05/2017 Page 9 of 12 1. 6.9 PRESIDETdT1ALSHAKE`", PRESIDENTiAIJNAKE, LOW AND STANDARD SLOPE: For low and standard slopes, use five nails for each full Presidential shingle as shown ,below. Nailing 1.----- 40' Guide Lines (1016 mot) 51f4- —� (1331M)) 141/4" 1112` 3B mot), (362 mm) NOTE: Apply nails on painted guideline. Figure 16.6.. FasieningFresidmMal and Presidential TL $bake .sbi ng(es on loot and standard slopes QoTaINITYIERD STEEP SLOPE: For steep slopes, use nine nails for each full Presidential shingle and apply 1' diameter spots of asphalt rooting cement under each shingle tab. After applying S nails in between the nailing guide lines, apply: 4 nails 1' above tab cutouts malting certain tabs of overlying shingle cover nails } 1' diameter asphalt roofing cement Figure 16-7.FastenIngFresiderrud and hesiAmlial'T/L Sbake sbingles on steep slopes. 6.9.1 Hip & Ridge for Presidential Shake`', Presidential Shake"'' IR Presidential Shake TLT" Presidential SolarisT": 6.9.1.1 Option 1: Presidential Accessory PRESIDENTIAL ACCESSORY Presidential accessory shingles can be used for covering hips and ridges. Apply shingles up to the ridge (expose no more than'7' from the bottom edge of the "tooth." Fasten each accessory with two fas- teners. The fasteners must be 13/4' long or lodger, so they penetrate either 3/4' into the deck or completely through the deck. Presidential accessory comes in two different sizes: Accessory produced in Birmingham, AL is 12' x 12% Portland, OR produces 97/s' x 131/4' accessory. 6.9.1.2 For ASTM D3161, Class F performance use BASF "Sonolastic® NPlT°` adhesive or Henkel "PL® Polyurethane Roof & Flashing Sealant", in accordance with CertainTeed requirements. 6.9.1.3 Option 2: Refer to instructions herein for Cedar CreStTM, Cedar CrestTM IR hip and ridge shingles. 6.10 LOW, STANDARD AND STEEP SLOPE: Figure /5.3. rartenlag llallems sbing/ts on Lour and slandard slopes For low and standard slopes, use five nails for each fall nauem shingle as shown above, Exterior Research and Design, I.I.C. Certificate ofAutharisation #9503 flgtur IS (: fialenhtg nalhaarXblgrfrs mr strepsloprs For steep slopes, use fife nails and eight spots of asphalt roofing cement for each full Ilmtetas shingle as shown above. Apply I* (25mm) dimneter spots of roofing cement (AMt D 4586I1W It suggested) under each lab comer. Press shingle into place; do not expose cement. CAUTION: Too mach fooling Cement can cause shingles to blister. Evaluation Report 3532.09.05-R13 CH EDITION (2027) FBC NON-HVHZ EVALUATION FL5444-R12 CertainTeed Asphalt Roof Shingles; (610) 651-5847 Revision 23: 09/05/2017 Page 10 of 12