Loading...
HomeMy WebLinkAboutLetter; Additional Information NarrativeOW July 31, 2018. To: Saint Lucie County Building Dept Re: ADDITIONAL IMFORMATION NARRATIVE Scope of Work: mow � ,2G,. 1510 E. Colonial Drive, Ste: 230, Orlando, F132803. Ph: (203)514-4221 • Fax (407)895-9061 Project: EVON 9 ADMIRAL ST RECEIVED FO T PIERCE, FL. 34982 AUG 0 2 2018 ST. Lucie County, Permitting 1.) Comment: PLEASE SUBMIT THE ELEVATIONS OF THE FINISHED GRADES FOR ANY OCCUPIED / NON-OCUPPIED ADJACENT STRUCTURES. THIS IS REQUIRED FOR THE DETERMINATION OF THE ELEVATION AND REQUIRERMENTS FOR THE STORM WATER SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE 6TH EDITION, AND. SECTION 7.04.01 (D) OF THE LAND DEVELOPMENT CODE. 6/25/2018 ---- SEE SURVEY 2.) Comment: PLEASE FURNISH ENEGRY CALULATIONS AND MANUAL J IN ACCORDANCE WITH SECTIONS 402 AND 403 OF THE 2017 FLORIDA ENEGRY CODE SIXFTH EDITION. NOTE ONLY; ENERGIES MUST HAVE ORIGINAL SIGNATURE OF PREPARER 6/25/2018-------------------------- SEE ENERY FORMS 3.) Comment: PLEASE SHOW FLAME SPREAD INDEX AND SMOKE DEVELOPED JINDEX FOR WALL AND CEILING FINISHES IN ACCORDANCE WITH SECTION 302.9 OF THE 2017 FLORIDA RESIDENTIAL CODE 6/25/2018-------- SEE DUM # 1 SHEET A-1 1> 1 4.) Comment: PLEASE SHOW THE FLAME SPREAD AND SMOKE DEVELOPED INDEX FOR THE INSULATION AS REQUIRED IN SECTION 302.10 OF THE 2014 FLORIDA RESIDENTIAL CODE 6/25/2018 5. Comment: PLEASE SHOW GYPSUM BOARD MATERIALS ARE IN ACCORDANCE WITH 702.3.1 OF THE 2?1'7 FLORIDA RESIDENTIAL CODE 6/25/2018 SEE ADDUM#1 SHEET A-1 ` 6.) Comment: PLEASE SHOW FIREBLOCKING IN ACCORDANCE WITH 702.3.1 OF THE 2017 FLORIDA RESIDENTIAL CODE 6/25/2018 SEE ADDUM#1 SHEET A -I I 7.) Comment: A REGISTERED BATING REQUIREMENT - A SIGNED CONTRACT ASSURING THE INSTALLATION, MAINTENANCE AND MONITORING OF THE BAITING SYSTEM THAT IS IN COMPLIANCE WITH THE REQUIREMENTS OF c�K CHAPTER 482, FLORIDA STATUTES SHALL BE PROVIDED TO THE BUILDING I OFFICIAL PRIOR TO THE POURING OF THE SLAB, AND THE SYSTEM MUST IV BE INSTALLED PRIOR TO FINAL BUILDING APPROVAL. 6/25/2018--=-- BUILDER NOTED ON SITE **FINE ARCHITECTURAL • ENGINEERING DESIGN ** **CONSTRUCTION MANAGEMENT** 8.) Comment: PLEASE SHOW THE BEDROOM WINDOWS AS EGRESS PER R310.2.1 OF THE 2017 FLORIDA BUILDING CODE SIXTH EDITION 6/25/2018 SEE ADDUM# 1 A-1 9.) Comment: PLEASE PROVIDE A WINDOW AND DOOR SCHEDULE 6/25/2018 1 .)Comment: ACCORDING TO OUR CALCULATIONS THE ELEVATION OF THE HOME IS HIGH IN RELATION TO THE NEIGHBORING PROPERTY. THE HOME MUST BE CONSTRUCTED ON A STEM WALL OR SUBMIT AN ENGINEER STORM WATER PLAN SHOWING THE RETENTION OF STORM WATER ON THIS PROPERTY. PER SECTION 7.04.01 (D) OF THE LAND DEVELOPMENT CODE 6/25/2018-------------------=--SEE SITE EL. SURVEY I1.)Comment: PLEASE ADD THE CUBIC VOLUME OF THE CONDITIONED SPACE TO INFORMATION BLOCK CONTAINING THE SQUARE FOOT INFORMATION. SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE SIXTH EDTITION. 6/25/2018-----------------------------------SEE ADUM#I A-1 12.)Comment: SUBMITTED DOCUMENTS MUST BE IN DUPLICATE. ONLY ONE SET OF FLORIDA PRODUCT APPROVAL OR N.O.A. NUMBER WITH INSTULATION INSTRUCTIONS AND SIGNED SEALED AND DATED BY THE DESIGN PERSON OF RECORD FOR ALL COMPONETS AND CLADING IN ACCORDANCE WITHSEE SECTION 107.1 OF THE 2017 FLORIDA BUILDING 2C DE. 6/25/2018---------------------SEE BUILDER PACKAGE 13.) omment: SHOW FLASHING DETAIL ON PLANS FOR ALL EXTERIOR WINDOWS AND DOORS. SEE SECTION R612.10 FLASHING, SEALANTS, AND WEATHER STRIPPING AND R703.8 FLASHING OF THE 2017 FLORIDA RESIDENTAL BUILDING CODE SIXTH EDITION. 6/25/2018----------------- SEE ADDUM# 1 A-12 14.) omment: PLEASE FURNISH 2 SETS OF ENGINEERED TRUSS DRAWINGS WITH THE (ENEGINEER OF RECORDS APPOVAL STAMP WITH ORIGNAL SIGNITURE) 107.2.1 OF THE 2017 FLORIDA BUILDING CODE SIXTH EDTITION. 6/25/2018 15.) omment: ACCORDING TO OUR CALCULATIONS THE ELEVATION OF THE OME IS HIGH IN RELATION TO THE NEIGHBORING PROPERTY. THE HOME MUST BE CONSTRUCTED ON A STEM WALL OR SUBMIT AN ENGINEER STORM WATER PLAN SHOWING THE RETENTION OF STORM WATER ON THIS PROPERTY. PER SECTION 7.04.01 (D) OF THE LAND DEVELOPMENT CODE. 6/25/2018----------------------------------SEE SURVEY 6.) Comment: PLEASE PROVIDE A ROOF FRAMING PLAN 107.2.1 OF THE 2017 FLORIDA BUILDING CODE SIXTH EDITION 6/25/2018------------------------ SEE BUILDER PACKAGE �= 17.)Comment: PLEASE PROVIDE A DETAIL FOR THE VEHICAL BARRIER FOR -- APPLIANCE IMPACT PROTECTION IN ACCORDANCE WITH M1307.3.1 OF THE 2017 FLORIDA BUILDING CODE SITH EDITION ZONING REVIEW INCOMPLETE Lydia Galbraith 6/13/2018 6/13/2018 1 .)Comment: THE SUBMITTED SITE PLAN IS INCOMPLETE: - SITE PLAN IS NOT TO SCALE - INDICATE ALL DIMENSIONS OF THE PROPOSED STRUCTURE ON THE SITE PLAN. - BASED ON ST LUCIE COUNTY LAND DEVELOPMENT CODE CHAPTER 7.06.02 (A) AND ITE PARKING MANUAL, THE PROPERTY IS REQUIRED TO PROVIDE TWO PAVED PARKING SPACES OF 10 X18 EACH. THE PARKING SPACES MAY BE AT THE PAVED DRIVEWAY. DRIVEWAY WILL NEED TO BE 20' WIDE TO ACCOMODATE 2 PARKING SPACES - PLEASE **FINE ARCHITECTURAL • ENGINEERING DESIGN ** **CONSTRUCTION MANAGEMENT** REMOVE SITE PLAN NOTE ZONE Rl AND SETBACK DETAIL. THIS IS INCORRECT. PROPERTY IS LOCATED IN ZONING DISTRICT RS-4 WITH SETBACK FRONT 25', SIDE 7.5', CORNER SIDE 20' AND REAR 15' - INDICATE SEPTIC AND DRAIN FIELD ON THE SITE PLAN. REVIEW COMMENTS Page 2 6/13/2018 SEE ADDUM A-1 19.) Comment: IS THE PROPERTY ON WELL WATER OR ON CITY WATER? IF ON WELL WATER PLEASE PROVIDE WELL PERMIT FROM THE HEALTH DEP. AND INDICATE THE LOCATION OF THE WELL ON THE SITE PLAN. IF ON CITY WATER, PLEASE PROVIDE A COPY OF THE RECEIPT FOR PAID UTILITY. 6/15/2018---------------------------------- CITY WATER 20.)Comment: PLEASE BE AWARE THAT ABOVE COMMENTS ONLY REFLECTS THE ZONING REVIEW. COMMENTS. THE PLANS EXAMINER MIGHT HAVE ADDITIONAL **FINE ARCHITECTURAL • ENGINEERING DESIGN ** **CONSTRUCTION MANAGEMENT**