Loading...
HomeMy WebLinkAboutReview Commentsii l var Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue FortPlerce,'FL- •34982 Phone:(772)4624172 Fax:(772)462-6443 PROPERTY INFORMATION Address: 2969 Admiral Street City / State / Zip: Fort Pierce, FI 34982 Parcel#: 2421-802-0074-000/0 Zoning: APPLICATION INFORMATION Permit Number: 1806-0153 REVIEW COMMENTS Owner(s): . Evon Thoa Ha / Vang Thi Phan Jurisdiction: SAINT LUCIE COUNTY Lot#: 22 Stories: Permit Type: BUILDING RESIDENTIAL (SFR UP TO 2 FLOORS) CONTRACTOR INFORMATION Contractor Name: John L George Business Name: George & Associates Contractors Inc s Addr: 610 1 St St �p Business tg �H City / State / Zip: Vero Beach , FI 32962 �`' REVIEWS AND COMMENTS Review Type Status ADDRESSING ASSIGNMENT COMPLETE m Comment: DOCUMENTS MISSING 6/7/2018 Comment: 6/7/2018 Comment: 6/7/2018 Comment: 6/13/2018 Comment: 6/18/2018 Comment: ENVIRONMENTAL REVIEW Comment: FRONT COUNTER REVIEW Comment: PLANS EXAMINER REVIEW 6/25/2018 Comment: Comment: 6/25/2018 Block: 6 Automatic Sprinkler System? No Fax Number: Email: C)rexfurd@Gmail.Com Reviewed By Date Started Date Completed Date Released Lori Bender 6/15/2018 6/15/2018 PENDING L)FI!5 �� CL NEEDS NOC C',oJ �� n,"' /, f"e' � NEEDS SUBS FOR ALL TRADES CONTRACTOR INFORMED THAT HE NEEDS TO SUBMIT VEG PERMIT ASAP. VEG PERMIT IN DRAWER UNDER "T" THOA HA. FEE LOADED. FILLED LANDS AFFIDAVIT PLEASE SUBMIT A DRIVEWAY APPLICATION. COMPLETE Lynn Swartzel 6113/2018 6/15/2018 COMPLETE Lashahna Ingram 617/2018 6/712018' 6/15/2018 617/2018 PENDING Joseph Fersch PLEASE NOTE THAT THE COMMENTS ARE FOR THE CLARIFICATION OR CORRECTION OF THE SUBMITTED DOCUMENTS. ADDITIONAL REVIEW MAY BE REQUIRED AFTER SUBMITTING CORRECTED DOCUMENTS. PLEASE SUBMIT THE ELEVATION OF THE INVERT FOR THE SEPTIC SYSTEM. THIS IS REQUIRED FOR DETERMINATION OF THE ELEVATION AND REQUIREMENTS FOR STORM WATER. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE, AND SECTION 7.04.01 (D) OF THE LAND DEVELOPMENT CODE. �t�tfiGG �Ot Planning & Development Services Building & Code Regulation Division. 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462.2172 Fax:(772)462-6443 REVIEW COMMENTS Page 2 Comment: PLEASE SUBMIT THE ELEVATIONS OF THE FINISHED GRADES FOR ANY OCCUPIED / NON-OCUPPIED 6/25/2018 ADJACENT STRUCTURES. THIS IS REQUIRED FOR THE DETERMINATION OF THE ELEVATION AND REQUIRERMENTS FOR THE STORM WATER SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE 6TH EDITION, AND SECTION 7.04.01 (D) OF THE LAND DEVELOPMENT CODE. Comment: PLEASE FURNISH ENEGRY CALULATIONS AND MANUAL J IN ACCORDANCE WITH SECTIONS 402 AND 403 6/25/2018 OF THE 2017 FLORIDA ENEGRY CODE SIXFTH EDITION. NOTE ONLY; ENERGIES MUST HAVE ORIGINAL SIGNATURE OF PREPARER Comment: PLEASE SHOW FLAME SPREAD INDEX AND SMOKE DEVELOPED INDEX FOR WALL AND CEILING FINISHES 6/25/2018 IN ACCORDANCE WITH SECTION 302.9 OF THE 2017 FLORIDA RESIDENTIAL CODE 6/25/2018 Comment: PLEASE SHOW THE FLAME SPREAD AND SMOKE DEVELOPED INDEX FOR THE INSULATION AS REQUIRED IN SECTION 302.10 OF THE 2014 FLORIDA RESIDENTIAL CODE 6/25/2018 Comment: PLEASE SHOW GYPSUM BOARD MATERIALS ARE IN ACCORDANCE WITH 702.3.1 OF THE 2017 FLORIDA RESIDENTIAL CODE 6/25/2018 Comment: PLEASE SHOW FIREBLOCKING IN ACCORDANCE WITH 702.3.1 OF THE 2017 FLORIDA RESIDENTIAL CODE Comment: A REGISTERED BATING REQUIREMENT - A SIGNED. CONTRACT ASSURING THE INSTALLATION, MAINTENANCE AND MONITORING OF THE BAITING SYSTEM THAT IS IN COMPLIANCE WITH THE 6/25/2018 REQUIREMENTS OF CHAPTER 482, FLORIDA STATUTES SHALL BE PROVIDED TO THE BUILDING OFFICIAL PRIOR TO THE POURING OF THE SLAB, AND THE SYSTEM MUST BE INSTALLED PRIOR TO FINAL BUILDING APPROVAL. Comment: PLEASE SHOW THE BEDROOM WINDOWS AS EGRESS PER R310.2.1 OF THE 2017 FLORIDA BUILDING 6/25/2018 CODE SIXTH EDITION 6/25/2018 Comment: PLEASE PROVIDE A WINDOW AND DOOR SCHEDULE Comment: ACCORDING TO OUR CALCULATIONS THE ELEVATION OF THE HOME IS HIGH IN RELATION TO THE NEIGHBORING PROPERTY. THE HOME MUST BE CONSTRUCTED ON A STEM WALL OR SUBMIT AN 6/25/2018 ENGINEER STORM WATER PLAN SHOWING THE RETENTION OF STORM WATER ON THIS PROPERTY. PER SECTION 7.04.01 (D) OF THE LAND DEVELOPMENT CODE Comment: PLEASE ADD THE CUBIC VOLUME OF THE CONDITIONED SPACE TO INFORMATION BLOCK CONTAINING 6/25/2018 THE SQUARE FOOT INFORMATION. SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE SIXTH EDTITION. Comment: SUBMITTED DOCUMENTS MUST BE IN DUPLICATE. ONLY ONE SET OF FLORIDA PRODUCT APPROVAL OR N.O.A. NUMBER WITH INSTULATION INSTRUCTIONS AND SIGNED SEALED AND DATED BY THE DESIGN 6/25/2018 PERSON OF RECORD FOR ALL COMPONETS AND CLADING IN ACCORDANCE WITHSEE SECTION 107.1 OF THE 2017 FLORIDA BUILDING CODE. Comment: SHOW FLASHING DETAIL ON PLANS FOR ALL EXTERIOR WINDOWS AND DOORS. SEE SECTION R612.10 6/25/2018 FLASHING, SEALANTS, AND WEATHER STRIPPING AND R703.8 FLASHING OF THE 2017 FLORIDA RESIDENTAL BUILDING CODE SIXTH EDITION. Comment: PLEASE FURNISH 2 SETS OF ENGINEERED TRUSS DRAWINGS WITH THE (ENEGINEER OF RECORDS 6/25/2018 APPOVAL STAMP WITH ORIGNAL SIGNITURE) 107.2.1 OF THE 2017 FLORIDA BUILDING CODE SIXTH EDTITION. Comment: ACCORDING TO OUR CALCULATIONS THE ELEVATION OF THE HOME IS HIGH IN RELATION TO THE NEIGHBORING PROPERTY. THE HOME MUST BE CONSTRUCTED ON A STEM WALL OR SUBMIT AN 6/25/2018 ENGINEER STORM WATER PLAN SHOWING THE RETENTION OF STORM WATER ON THIS PROPERTY. PER SECTION 7.04.01 (D) OF THE LAND DEVELOPMENT CODE. 6/25/2018 Comment: PLEASE PROVIDE A ROOF FRAMING PLAN 107.2.1 OF THE 2017 FLORIDA BUILDING CODE SIXTH EDITION Comment: PLEASE PROVIDE A DETAIL FOR THE VEHICAL BARRIER FOR APPLIANCE IMPACT PROTECTION IN 6/25/2018 ACCORDANCE WITH M1307.3.1 OF THE 2017 FLORIDA BUILDING CODE SITH EDITION ZONING REVIEW �C"�NrDI � EfALL DINT ISIC NHS OFT 4�E RIt(— ED STRUCTURE ON THE SITE PLAN. - SED ON !S �LG�GIE-000NNT�Y I AND EUELOPMENT CODE CHAPTER 7.06:02 (A) AND ITE PARKING ANUAL THE PROP R'Ty IS Ro IRED�TO PROVIDE TWO PAVED PARKING SPACES OF 10'X18' EACH. THE 6113/20 8 PART If G�SPAC S MAY BE-AT�`TH-E-,P VED DRIVE1NdY. DRIVEWAY WILL NEED TO BE 20' WIDE TO YAGC�©M QD,AT 2 PARKINC'sSFACES'' t°� P E BM' MOVE SITE RLANjNOTE-ONE R1 AND SETBACK DETAIL. THIS IS INCORRECT. PROPERTY IS LOC�A ED I ONING DISTRICT RS 4 WITH SETBACK FRONT 25', SIDE 7.5; CORNER SIDE 20' AND REAR 15' - IN51.0-WTt .SEPTIC AND DRAIN FIELD ON THE SITE PLAN. Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)4624172 Fax:(772)462-6443 REVIEW COMMENTS Comment. THEPRO�PERT«Y ON WELL WATER OR ON CITY WATER? IF�Of �tjN1�UATE-RLE SE PROVIDE WELL PERMIT FROM THE HEALTH DEP. AND INDICATE THE 6/13/2018 OC° T7U'E�INELL ON THE SITE PLAN. IFiON CI�TsYiWAT R. PLEASE PROVIDE A COPY OF THE RECEIPT FOR PAID UTILITY. 6/15/2018 Comment: PLEASE BE AWARE THAT ABOVE COMMENTS ONLY REFLECTS THE ZONING REVIEW. THE PLANS EXAMINER MIGHT HAVE ADDITIONAL COMMENTS.