Loading...
HomeMy WebLinkAboutRevision; Product Approval for Windows & DoorsOFFICE USE ONLY: DATE FILED: REVISION FEE: i LOCATION/SITE ADDRESS: PERMIT # / U 6 0 r 6-�? RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATIONDIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982.5652 (772) 462.1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION DETAILED DESCRIPTION OF PROJECT REVISIONS: CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: CG-GJr I 3,Yo ST. LUCIE CO CERT. #: BUSINESS NAME: eD _ QUALIFIERS NAME: .9 - ADDRESS: 36 S. di � k4ve- Scr; CITY: . i e STATE: C'L ZIP: PHONE (DAYTIME): 93 Do FAX: OWNER/BUILDER INFORMATION: NAME: ADDRESS: CITY: STATE: PHONE (DAYTIME: ARCHITECT/ENGINEER INFORMATION: NAME: a2a, _ ADDRESS: FAX: CITY: STATE: PHONE (DAYTIME): FAX: _ SLCCC: 9123109 Revised 06130/17 ZIP: ZIP: Florida Building Code Online .. Page 1 of 2 FL # FL19715-R4 CODE bOMPLIANCE y Application Type Revision ST■ LUCIE COUNTY Code Version 2017 Application Status Approved ®OCC Comments Archived C) Product Manufacturer Silver Line Building Products Corp. Address/Phone/Email One Silverline Drive North Brunswick, NJ 08902 (732) 435-1000 jonberrian@slbp.com Authorized Signature Jon Berrian jonberrian@slbp.com Technical Representative Jon Berrian Address/Phone/Email One Silverline Drive North Brunswick, NJ 08902 (732) 435-1000 jonberrian@slbp.com Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Single Hung Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer © Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Hermes F. Norero, P.E. the Evaluation Report Florida License PE-73778 Quality Assurance Entity Window and Door Manufacturers Association-QA Quality Assurance Contract Expiration Date 12/31/2019 Validated By Locke Bowden P.E. W Validation Checklist - Hardcopy Received Certificate of Independence FL19715 R4 COI COI Silverline SS 2017-06-14.odf Referenced Standard and Year (of Standard) Standard Year AAMA/WDMA/CSA 101/I.S.2/A440 2011 AAMA/WDMA/CSA 101/I.S.2/A440 2008 ASTM E1886 2005 ASTM E1996 2012 ASTM E330 2002 TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By https://floridabuilding.org/prlpr_app_dtl. aspx?param=wGEVXQwtDgtvA%2bxmzkl hGufB... 5/8/2019 • Florida Building Code Online i Page 2 of 2 0 Sections from the Code Product Approval Method Method 1 Option D Date Submitted 12/18/2017 Date Validated 12/18/2017 Date Pending FBC Approval 12/29/2017 Date Approved 02/13/2018 Summary of Products FL # Model, Number or Name Description 19715.1 Series 2900/4900 Single Hung Extruded Vinyl Single Hung Window Limits of Use Installation Instructions Approved for use in HVHZ: No FL19715 R4 II SWD002 SS 2017-12-15.odf Approved for use outside HVHZ: Yes Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See Installations Instructions and Product Evaluation FL19715 R4 AE PER5375 SS 2017-12-15.pdf Report for design pressure tables and limitations of use. Created by Independent Third Party: Yes 19715.2 Series 2900/4900 Single Hung Extruded Vinyl Single Hung Window Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL19715 R4 II SWD012 SS 2017-12-15.odf Approved for use outside HVHZ: Yes Verified By: Hermes F. Norero Florida P.E. 73778 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See Installations Instructions and Product Evaluation FL19715 R4 AE PER5376 SS 2017-12-15.Ddf Report for design pressure tables and limitations of use. Created by Independent Third Party: Yes 19715.3 Series 70 Model 2127 Single Hung Extruded Vinyl Single Hung Window Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL19715 R4 II SWD010 SS 2017-12-18.Ddf Approved for use outside HVHZ: Yes Verified By: Hermes F. Norero Florida P.E. 73778 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See Installations Instructions and Product Evaluation FL19715 R4 AE PER4805 SS 2017-12-18.Ddf Report for design pressure tables and limitations of use. Created by Independent Third Party: Yes 19715.4 Series 70 Model 2127 Single Hung Extruded Vinyl Single Hung Window Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL19715 R4 II SWD011 SS 2017-12-18.Ddf Approved for use outside HVHZ: Yes Verified By: Hermes F. Norero Florida P.E. 73778 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See Installations Instructions and Product Evaluation FL19715 R4 AE PER4806 SS 2017-12-18.odf Report for design pressure tables and limitations of use. Created by Independent Third Party: Yes Back Nezt Contact Us :; 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:; Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275 (1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter.455, F.S., please click hem . Product Approval Accepts: MMUMME hGufB... 5/8/2019 SILVER LINE BUILDING PRODUCTS V1 SERIES170 SERIES SINGLE HUNG WINDOW (2127) (IMPACT RATED) GENERAL NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE 6TH EDITION FLORIDA BUILDING CODE (FBC), INCLUDING HVHZ AND HAS BEEN EVALUATED ACCORDING TO THE FOLLOWING: • TAS 201-94 • TAS 202-94 • TAS 203-94 _ • ASTM E33D-02 • ASTM E1886-05 • ASTM E1996-06/09/12 • AAMA/WDMA/CSA 101/1.5.2/A440-08 2. ADEQUACY OF THE EXISTING STRUCTURAL CONCRETE/MASONRY, 2X FRAMING, AND METAL FRAMING AS A MAIN WIND FORCE RESISTING SYSTEM CAPABLE OF WITHSTANDING AND TRANSFERRING APPLIED PRODUCT LOADS TO THE FOUNDATION IS THE RESPONSIBILITY OFTHE ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF INSTALLATION. 3. 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED AND ANCHORED AS SPECIFIED HEREIN. REFER TO SHEETS FOR FURTHER DETAILS OF BUCK INSTALLATION. 4. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED ENGINEER OR ARCHITECTSHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT IN NON-HVHZ AREAS. IN HVHZ AREAS, ONE TIME PRODUCT APPROVALTO BE OBTAINED FROM MIAMI-DADE RER OR AHJ. S. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED ON THIS PRODUCT IN AREAS REQUIRING IMPACT RESISTANCE. 6. WINDOW FRAME MATERIAL: PVC 7. IN ACCORDANCE WITH THE 6TH EDITION FBC, WOOD COMPONENTS SHALL HAVE BEEN PRESERVATIVE TREATED OR SHALL BE OF A DURABLE SPECIES AS DEFINED IN CHAPTER 23. 8. GLASS MEETS THE REQUIREMENTS OF ASTM E 1300 GLASS CHARTS. SEE SHEET 5 FOR GLAZING DETAILS. MAX OVERALL SIZE CONFIG. DESIGN MISSILE WIDTH HEIGHT PRESSURE IMPACTRATING 52" 73" 0/X +55/-60 PSF LMI/SMI TABLE OF CONTENTS SHEET REVISION SHEET DESCRIPTION 1 GENERAL NOTES & GLAZING DETAIL 2 - ELEVATION&ANCHOR LAYOUTS 3 - VERTICALSECTIONS 4 - HORIZONTAL SECTIONS 5 _ HORIZONTAL & VERTICAL SECTIONS, INSTALLATION NOTES & REINFORCEMENT DETAILS 43/64" O.A. I.G. LAMINATED GLASS CONSISTING OF: 1/8" ANNEALED GLASS 7/32"STEEL SPACER 0 ANNEALED GLASS F-3/32" 0.09 0.090"SAFLEX PVBINTERIAYER BY EASTMAN CHEMICAL COMPANY ANNEALED GLASS EXTERIOR / INTERIOR I I STEELSPACER � MIN. GLASS 1/8" OR 3/32" BITE 7/16" SETTW G BLOCK DOW 995 SEALANT GLAZING DETAIL 1 NOTE: ALL GLAZING CONFIGURATIONS SHALL COMPLY WITH SAFETY GLAZING REQUIREMENTS OUTLINED IN CURRENT FBC AND ASTM E 1300 GLASS LOAD RESISTANCE. ojlLL w O wa Fz �3�5IS� oZ aQd 2p Z l7 $ w m m �x � w F n a a 1 6TH FBC EDMON I LM 106/14/171 Digitally signed by yjrl qls F. Norero, Reason: I �Q�Spd�oLIn-g If)is/Jp�ymer Date:2 2.d8R8r35 G Q507 D T T r :moo •.r L OP:' �40 NAL 328 E DANA BEAOI 8Qf 335 DANA BEACH,FL FBPE CERT. OFAN7HOATIDN Nu 20575 FL 11: FL19715 DATE: 12.11.17 DWG. BY: CHK. BY: LMS HFN SCALE: NTS DWG.N: SWD011 SHEET: MIN, SUBSTRATE 2/4" MAX. EDGE DISTANCE BY OTHERS SHIM SPACE � � INTERIOR AIY// MIN, EMBEDMENT ---j" PERIMETER SEALANT _r 1/0MAX. ) PERIMETER BY OTHERS SHIM SPACE EXTERIOR U INTERIOR VERTICAL SECTION ©—THROUGH FRAME (HEAD) 1/4" MAX. SHIM SPACE MIN. EDGE DISTANCE /1� HORIZONTAL SECTION 6 NAIL FIN (JAMB) EXTERIOR BY OTHERS SCREW IN THE INTERIOR 'CHANNEL MIN. EDGE DISTANCE w SCREW IN THE EXTERIOR CHANNEL 2 55 EXTERIOR MIN, EMBEDMENT OB HORIZONTAL SECTION 6 THROUGH FRAME (JAMB) VERTICAL SECTION 6 MEETING STILE INSTALLATION NOTES: 1. ONE (1) INSTALLATION ANCHOR IS REQUIRED AT EACH ANCHOR LOCATION SHOWN. 2, THE NUMBER OF INSTALLATION ANCHORS DEPICTED IS THE MINIMUM NUMBER OFANCHORS TO BE USED FOR PRODUCT INSTALLATION OF THE MAXIMUM SIZE LISTED. 3. INSTALL INDIVIDUAL INSTALLATION ANCHORS WITHIN ATOLERANCE OF al/2INCH THE DEPICTED LOCATION & SPACING IN THE ANCHOR LAYOUT DETAILS (I,E., WITHOUT CONSIDERATION OF TOLERANCES). TOLERANCES ARE NOT CUMULATIVE PROM ONE INSTALLATION ANCHOR TO THE NEXT, 4. SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM(S). MAXIMUM ALLOWABLE SHIM STACK TO BE 3/81NCH, SHIM WHERE SPACE OF 1/161NCH OR GREATER OCCURS. SHIM(S) SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER, S. MINIMUM EMSEDMENTAND EDGE DISTANCE EXCLUDE WALL FINISHES, INCLUDING BUT NOT LIMITEDTO STUCCO, FOAM, BRICK VENEER, AND SIDING. 6, INSTALLATION ANCHORS AND ASSOCIATED HARDWARE MUST BE MADE OF CORROSION RESISTANT MATERIAL OR HAVE A CORROSION RESISTANT COATING, 7. FOR HOLLOW BLOCK AND GROUT FILLED BLOCK, DO NOT INSTALL INSTALLATION ANCHORS INTO MORTAR JOINTS, EDGE DISTANCE IS MEASURED FROM FREE EDGE OF BLOCK OR EDGE OF MORTAR JOINT INTO FACE SHELL OF BLOCK. S. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BY THE ANCHOR MANUFACTURER, 9. FOR INSTALLATION ANCHORS ABOVE THE MEETING RAIL IN THE INTERIOR JAMB TRACK, USE FLAT HEAD ANCHORS. MIN, EMBEDMENT I BY OTHERS SHIM SPACE EXTERIOR in INTERIOR HORIZONTAL SECTION 6 NAIL FIN (HEAD) REINFORCEMENT DETAILS 0 83" 0.87" �� 1-0.34" —� " --�I -- 0.13 INTERIOR J7" 0 106" 0 8 I — 0.46" 0.45" O PO MEETING ING RAIL OU N LFT RAIL &SASHALUMNUM AUMIMALIM ANCHOR SCHEDULE METHOD SUBSTRATE ANC14098CHEDULS MIN EMBEDMENT MIN. EDGE olarANCE WOOD: MIN. YB WOOD SCREW PAN HEAD 1.6• 0.76' NAILING FIN METAL: 160 W, IY6 TEKBCREW 3 THREADS MIN MIN. Fy-33KSI 33KS1 PENETRATION BEYOND DSO' METAL 010 PAN HEAD IN 16. 0.75' EXTERIOR CHANNEL WOOD: MIN, 80"DS0 010 FLATHEAD INTHE 1,6' 0.76' INTERIOR CHANNEL 010 PAN HEAD IN 3 THREADS MIN EXTERIOR CHANNEL PENETRATION BEYOND 0.00' THROUGH FRAME METAL.Is , METAL Nt EAO IN 3 THREADS MIN Fy-33KBIAUGE MIN. Fy e33K61 EL INTERIORCHANNEL PENETRATION BEYOND DSO' METAL CONCRETE: fea30WP81 3116'IFWTAPCON FIAT HEAD 126' 1.75' AASONRV:CMUP$IASTM3n6'rrWTAPCON 126' t.7b• COO MIN. 20M PSI FLATHEAD L NOR 1 6TH F6C 0 FI 330 E. FBPC coy FLa: F DATE: SCALE: DWG. H: SECTION FOR BLOCK & TACKLE _ BALANCERS � IR74 SEE GLAZING DETAIL SHEET 1 INTERIOR EXTERIOR D.L.O. MAX. FRAME WIDTH HORIZONTAL SECTION 4 FIXED JAMB SEE GLAZING - DETAIL SHEET 1 INTERIOR SECTION FOR SEE GLAZING CONSTANT FORCE DETAILSHEETI /o` BALANCERS SEE GLAZING DETAIL SHEET I EXTERIOR D.L.O. MAX. FRAME WIDTH rQ-� HORIZONTAL SECTION 4 FIXED JAMB Sliver Line JnAndersen EO' ONE 511VERLINE DRNE NORTH BRUNSWICK, NJ 08902 PH: 800 2334228 Z Z ry z E $ 8 w� O� 4 a � p No �mm��agg oz a Zss=$S > �3 0 00 Z v 1 :3 K m � S > • m W z 0. F' F 2 a REMARKS BY DATE 6TH FBC EDOION LM 06/Id/2'. 39✓t r DR" DANIA SO W. FBfAOI LW BW. SSB FBPE OW. Or AUIHO IION N. M78 FL #: FL19715 DATE: 12.11.17 DWG. BY: K. BY: LMS I HFN SCALE: NTS DWG.#: SWD011 SHEET: /[�I� 4 MAX. O.A FRAME WIDTH 52" MAX. D.L.O. WIDTH 47.69" A B 3 3 MAX. D.LO. "0" HEIGHT 33.50" C MAX. 0.A FRAME HEIGHT 73" MAX. D.L.O. HEIGHT 33.50" t- .X., ELEVATION SINGLE HUNG WINDOW 3" MAX. 6" MAX. 6.25" MAX. FROM O.C. FROM CORNERS I� r CORNERS I 6" MAX._ O.C. 3" MAX. FROM CORNERS T I ANCHOR LAYOUT NAIL FIN - SINGLE HUNG WINDOW NOTE: ALLFASTENERS ABOVE THE MEETING RAIL IN THE INTERIOR JAMB TRACK MUST BE FLAT HEAD 12.50" MAX. O.C. 6.25" MAX. FROM CORNERS L I ANCHOR LAYOUT THROUGH FRAME -SINGLE HUNG WINDOW Silver Line >nAndeisen m, ONE 91LVERUNE DRIVE NORTH BRUNSNICK, NJ OB902 ' PH: 8011234-4228 ZN E E 0 $¢a Q w 0 � x z D'59 � 2L C3 oz �3 a 0° 0m zsgs o w z Z � _ O I 7 a Do >x m w � a a � a REMARKS BY DATE MFBCEDmON I LM D6114/1 JDB 01 SEWFL 31mi & RIPE CERT. OF JOJ3Ha TIOJ Na n5M FL #: FL19715 DATE: 12.11.17 DWG. BY: CHK. BY: LMS HFN SCALE: ' NTS DWG.#: SWD011 SHEET: 2 riuriun nullulilg uciuc Vllll,r-, 1-1 rage i of D / cc Yo Product Approval .USER: Public User Product Approval Menu > Product or ADDlication Search > ApDlIcatlon List > Application Detail FL # FL23507 REVIEWED Application Type Code Version New 2017 FOR CODE COMPLIANCE Application Status Approved STa LUCIE COUNTY Comments EOCC Archived I �✓ �s Product Manufacturer Therma-Tru Corporation Address/Phone/Email 118 Industrial Drive Edgerton, OH 43517 (419) 298-1740 rickw@rwbldgconsultants.com Authorized Signature Vivian Wright rickw@rwbldgconsultants.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Evaluation Report from 'a Florida Registered Architect or a Licensed Florida Professional Engineer j M Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F. Schmidt, P.E. the Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2019 Validated By Ryan ]. King, P.E. 2 Validation Checklist - Hardcopy Received Certificate of Independence FL23507 RO COl (a) Certificate of Indeoendence.odf Referenced Standard and Year (of Standard) Standard Year ASTM D1929 1996 -ASTM E1300 2004 ASTM E1886 2005 ASTM E1996 2006 ASTM E84 2000 TAS 201, 202, 203 1994 Equivalence of Product Standards Certified By Sections from the Code https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtnDFS1nZKXOhotL8... 5/8/2019 rlonaa nunuing uoue tom_ i rage z Oi Z) Product Approval Method Method 1 Option D Date Submitted 10/08/2017 Date Validated 10/16/2017 Date Pending FBC Approval 10/19/2017 Date Approved 12/12/2017 Summary of Products FL # Model, Number or Name Description 23507.1 a. Therma-Tru@ Traditions and Nominal 6'8 "Impact" Opaque Wood Edge Steel Single Door Profiles'" Steel Doors (Inswing/Outswing; X configuration) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL23507 RO II Inst 23507.1,odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent.Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 23507.1 for Design Pressure Ratings by FL23507 RO AE (a) Eval 23507.1.odf specific Model and for any other additional use limitations and FL23507 RO AE (b) TT Plastics.odf installation instructions. Created by Independent Third Party: Yes 23507.2 b. Therma-Tru@ Traditions and Nominal 6'8 "Impact" Opaque Wood Edge Steel Single Door Profiles'" Steel Doors with Sidelite(s) (Inswing/Outswing; XO, OX or OXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL23507 RO II Inst 23507.2.Ddf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 23507.2 for Design Pressure Ratings by FL23507 RO AE (b) TT Plastics.odf specific Model and for any other additional use limitations and FL23507 RO AE Eval 23507.2.pd installation Instructions. Created by Independent Third Party: Yes 23507.3 c. Therma-Tru® Traditions and ProfllesT" Steel Doors Nominal 6'8 "Impact" Opaque Wood Edge Steel Single Door with "Non -Impact" Sidelite(s) (Inswing/Outswing; XO, OX or OXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL23507 RO II Inst 23507.3.pdf Approved for use outside HVHZ: Yes Verifled By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 23507.3 for Design Pressure Ratings by FL23507 RO AE (b) TT Plastics.odf specific Model and for any other additional use limitations and FL23507 RO AE Eval 23507.3.Ddf 1 Installation Instructions. Created by Independent Third Party: Yes 23507.4 d. Therma-Tru® Traditions and Profiles- Steel Doors Nominal 6'8 "Impact" Opaque Wood Edge Steel Double Door with or without Sidelites (Inswing/Outswing; XX or OXXO configurations) Limits of Use Installation Instructions Approved for use In HVHZ: Yes FL23507 RO 11 Inst 23507.4.Ddf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 23507.4 for Design Pressure Ratings by FL23507 RO AE (b) TT Plastics.odf specific Model and for any other additional use limitations and FL23507 RO AE Eval 23507.4.Ddf Installation Instructions. Created by Independent Third Party: Yes 23507.5 e. Therma-Tru® Traditions and ProfllesT" Steel Doors Nominal 6'8 "Impact" Opaque Wood Edge Steel Double Door with "Non -Impact" Sidelites (Inswing/Outswing; XX or OXXO configurations) Limits of Use Installation Instructions Approved for use In HVHZ: Yes FL23507 RO II Inst 23507.5.odf Approved for use outside HVHZ: Yes Verlfled By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 23507.5 for Design Pressure Ratings by FL23507 RO AE (b) TT Plastics.odf speclflc Model and for any other additional use limitations and FL23507 RO AE Eval 23507.5,Ddf Installation instructions. Created by Independent Third Party: Yes 123507.6 I f. Therma-Tru® Traditions Steel ors IInswing8'0 "Impact" Opaquera Wood Edge Steel Single Door ion Limits of Use Approved for use In HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Installation Instructions FL23507 RO i1 Inst 23507.6.ndf Verified By: Lyndon F.. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports https:Hfloridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtnDFS1nZKXOhotL8... 5/8/2019 rionaa ijunaing uoae �nr�� � rage i of Other: See INST 23507.6 for Design Pressure Ratings by FL23507 RO AE (b) TT Plastics.Ddf specific Model and for any other additional use limitations and FL23507 RO AE Eval 23507.6.odf installation Instructions. Created by Independent Third Party: Yes 23507.7 g. Therma-Tru@ Traditions Steel Nominal 8'0 "Impact" Opaque Wood Edge Steal Single Door Doors with "Non -Impact" Sidelite(s) (Inswing/Outswi ng; XO, OX or OXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL23507 RO 11 Inst 23507.7.pd Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 23507.7 for Design Pressure Ratings by FL23507 RO AE (b) TT Plastics.odf specific Model and for any other additional use limitations and FL23507 RO AE Eval 23507.7.1)df installation instructions. Created by Independent Third Party: Yes 23507.8 h. Therma-Tru@ Traditions Steel Nominal 8'0 "Impact" Opaque Wood Edge Steal Double Door Doors with "Non -Impact" Sidelites (Inswing/Outswing; XX or OXXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL23507 RO 11 Inst 23507.8.Ddf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 23507.8 for Design Pressure Ratings by FL23507 RO AE (b) TT Plastics.adf specific Model and for any other additional use limitations and FL23507 RO AE Eval-23507.8.Ddf installation instructions. Created by Independent Third Party: Yes 23507.9 i. Therma-Tru@ Traditions and Profiles'" Steel Doors Nominal 6'8 "Impact" Glazed Wood Edge Steel Single Door (Inswing/Outswing; X configuration) Limits of Use Installation Instructions Approved for use In HVHZ: Yes FL23507 RO Ii Inst 23507.9.Ddf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 23507.9 for Design Pressure Ratings by FL23507 RO AE (b) TT Plastics.pdf specific Model and for any other additional use limitations and FL23507 RO AE Eval 23507.9.g_df installation instructions. Created by Independent Third Party: Yes 23507.10 J. Therma,,-Tru@ Traditions and Profiles'" Steel Doors Nominal 6'8 "Impact" Glazed Wood Edge Steel Single Door with Sidelite(s) (Inswing/Outswing; XO, OX or OXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL23507 RO II Inst 23507.10.odf Approved for use outside HVHZ: Yes Verifled By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 23507.10 for Design Pressure Ratings by FL23507 RO AE (b) TT Plastics.Ddf speclflc Model and for any other additional use limitations and FL23507 RO AE Eval 23507.10.Ddf Installation instructions. Created by Independent Third Party: Yes 23507.11 k. Therma-Tru® Traditions and Profiles'" Steel Doors Nominal 6'8 "Impact" Glazed Wood Edge Steel Double Door with Sidelites (Inswing/Outswing; XX or OXXO conflgurations) Limits of Use Installation Instructions Approved for use In HVHZ: Yes FL23507 RO II Inst 23507.11.odf Approved for use outside HVHZ: Yes Verifled By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 23507.11 for Design Pressure Ratings by FL23507 RO AE (b) TT Plastics.odf specific Model and for any other additional use limitations and .FL23507 RO AE Eval 23507.11.Ddf Installation Instructions. Created by Independent Third Party: Yes 23507.12 I. Therma-Tru® Traditions Steel Doors Nominal 8'0 "Impact" Glazed Wood Edge Steel Single Door (Inswing/Outswing; X configuration) Limits of Use Installation Instructions Approved for use In HVHZ: Yes FL23507 RO 11 inst 23507.12.pdf Approved for use outside HVHZ: Yes Verifled By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 23507.12 for Design Pressure Ratings by FL23507 RO AE (b) TT Plastics.Ddf speclflc Model and for any other additional use limitations and FL23507 RO AE Eval 23507.12 odf Installation Instructions. Created by Independent Third Party: Yes 23507.13 m. Therma-Tru® Traditions Steel Nominal 8'0 "Impact" Glazed Wood Edge Steel Single Door Doors with Sidelite(s) (Inswing/Outswing; XO, OX or OXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL23507 RO II Inst 23507.13 odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 https:Hfloridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgtnDFS1nZKXOhotL8... 5/8/2019 riuliva Du11u111g wuc v1L I/ Page 4 OI J Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 23507.13 for Design Pressure Ratings by FL23507 RO AE (b) TT Plastics.pdf specific Model and for any other additional use limitations and FL23507 RO AE Eval 23507.13.odf Installation instructions. Created by Independent Third Party: Yes 23507.14 n. Therma-True Traditions Steel Doors Nominal 8'0 "Impact" Glazed Wood Edge Stee I Double Door with Sidelites (Inswing/Outswing; XX or OXXO configurations) Limits of Use Installation Instructions Approved for use In HVHZ: Yes FL23507 RO 11 Inst 23507.14.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 23507.14 for Design Pressure Ratings by FL23507 RO AE (b) TT Piastics.odf specific Model and for any other additional use limitations and FL23507 RO AE Eval 23507.14,12df Installation Instructions. Created by Independent Third Party: Yes 23507.15 [o.rsThrma-Tru@.Traditions Steel Nominal 8'0 "Non -Impact" Glazed Wood Edge Steel Single Door (Inswing/Outswing; X configuration) Limits of Use Installation Instructions Approved for use In HVHZ: Yes FL23507 RO Il Inst 23507.15.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created,by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 23507.15 for Design Pressure Ratings by FL23507 RO AE (b) TT Plastics.odf specific Model and for any other additional use limitations and FL23507 RO AE Eval 23507.15.odf installation instructions. I Created by Independent Third Party: Yes 23507.16 p. Therma-Trup Traditions Steel Doors Nominal 8'0 "Non -Impact" Glazed Wood Edge Steel Single Door with "Non -Impact" Sidelite (Inswing/Outswing; OX or XO configurations) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL23507 RO I1 Inst 23507.16.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 23507.16 for Design Pressure Ratings by FL23507 RO AE (b) TT Plastics.odf specific Model and for any other additional use limitations and FL23507 RO AE Eval 23507.16.odf installation instructions. Created by Independent Third Party: Yes 23507.17 q. Therma-Trup Traditions Steel Doors Nominal 8'0 "Non -Impact" Glazed Wood Edge Steel Single Door with "Non -Impact" Sidelites (Outswing; OXO configuration) Limits of Use Installation Instructions Approved for use In HVHZ: Yes FL23507 RO II Inst 23507 17 odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 23507.17 for Design Pressure Ratings by FL23507 RO AE (b) TT Plastics.pdf specific Model and for any other additional use limitations and FL23507 RO AE Eval 23507 17 odf Installation instructions. Created by Independent Third Party: Yes 23507.18 r. Therma-Tru® Traditions and Profiles- Steel Doors Nominal 6'8 "Non -Impact" Glazed Wood Edge Steel Single Door with Sidelite Center Hinged with a Continuous Head and Sill (Outswing; XO or OX configurations) Limits of Use Installation Instructions Approved for use.in HVHZ: Yes FL23507 RO II Inst 23507.18.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 23507.18 for Design Pressure Ratings by FL23507 RO AE (b) TT Plastics Ddf specific Model and for any other additional use limitations and EL23507 RO AE Eval 23507.18 odf Installation Instructions. Created by Independent Third Party: Yes 23507.19 s. ThermaTru Steel Edge Door Nominal 6'8 "Impact" Opaque Steel Edge Steel Single Door Utilizing a Fixed Steel Door Frame (Inswing/Outswing; X configuration) . Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL23507 RO Il Inst 23507.19.ndr Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 23507.19 for Design Pressure Ratings by FL23507 RO AE Eva[ 23507 19.odf specific Model and for any other additional use limitations and Created by Independent Third Party: Yes Installation Instructions. 23507.20 t. ThermaTru Steel Edge Door Nominal 6'8 "Impact" Opaque Steel Edge Steel Single Door Utilizing an Adjusta-Fit 2 Steel Door Frame (inswing/Outswing; X configuration) https:Hfloridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtnDFS1nZKXOhotL8... 5/8/2019 xwiiva i-iuiiuuig %,vuL; vlii �"'-� Limits of Use Installation Instructions Approved for use in. HVHZ: Yes FL23507 RO 1I Inst 23507.20.Ddf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 23507.20 for Design Pressure Ratings by FL23507 RO AE Eval 23507.20.Ddf specific Model and for any other additional use limitations and Created by Independent Third Party: Yes installation instructions. Beck Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Rehr nd Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275 (1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which ran be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtnDFS1nZKXOhotL8... 5/8/2019 THERMA11RU• DOORS Profiles- & Traditions WOOD EDGE GLAZED STEEL SINGLE DOOR INSWING/OUTSWING "IMPACT' GENERAL NOTES 1. This product evaluation drawing has been developed in compliance with the 6th Edition (2017) Florida Building Code (FBC) including the "High Velocity Hurricane Zone" (HVHZ). 2 Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shag be beyond wall dressing or stucco. 3. When used in the "HVHZ" this product complies with Section 1626 of the FBC and does not require an impact resistant covering. 4. When used in areas outside of the "HVHZ" requiring wind bome debris protection, this product complies with FBC Sections 1609.1.2 & R30121.2 and does not require an impact resistant covering. This product meets missile level'V and includes Wind Zone 4 as defined in ASTM E 1996 and FBC Sections 1609.1.2.2 & R30121 91. 5. For 2x stud framing construction, anchoring of these units shall be the same as that shown foj 2X buck masonry construction. 6. Site conditions that deviate from the details of this drawing require further engineering analysis by a licensed engineer or registered architect. 7. Outswing configurations using Sig numbers 16,17,18 & 31 meet the water infiltration requirements for the TiVHP. Ali other configurations do not meet the water infiltration requirements for the "HVHZ" and shall be installed only in non -habitable areas or at habitable locations protected by an overhang or canopy such that the angle between the edge of canopy or overhang to sill is less than 45 degrees. TABLE OF CONTENTS SMTB DESCRIPTION SHEET# DESCRIPTION I Typkxg Elevations, Design Pressures & Gerard Notes 8 Vertical Cross Sections (ihreshdds) 2 Door Panel Detois Yrofies- 9 Buck & Rome Anchoring 3 Door Panel aetab-Tradliors- 10 HardwareDetaits 4 Elevations 1 I Glaring DetaSs 5 Hart'vnntal & Verfcd Cross Sections 12X Buck) 12 Components 6 Horizontal & Vertical Cross Sect!= IX BucYJ 13 BM of Materials o v ` N U 37.75" MAX O.A. FRAME WIDTH $E`oz° Mw �o z Z t o i J O ? (j x 5E ' = X A as C4 = Q o Lj KQ2 Q a ' DESIGN PRESSURE (PSF) DESIGN PRESSURE (PSF) CONFIGURATION DOOR PANEL INSWING OUTSWING POSITIVE NEGATIVE POSMVE NEGATIVE x "PROFILES" -47.0 -53.0 -50.0 -50.0 x -TRADITIONS" -47.0 -53.0 -50.0 -50.0 z Z a e 10112 17 2 am N.T.S. 7 er: JK m ar: LFS 3 ,WING NO.: 0: t FL-23507.9 0 ET 1 of 13 n GI EXTERIOR 2.625 N L a TOP RAIL =N: /i�j� •' /� ��I�?�� > >° ° m `� m M 36Z MAX. DOOR PANEL WIDTH INTERIOR LOCK BLOCK LATCH STILE (WOOD) /lll 1111 o p m i 10.,W LONG (WOOD) (WOOD) ^ 8 N oa Em Z o N \4,rK O m "U M 9 1 HOMONTAL CROSS SEMN d 'm d a 2 v o z E FOAM CORE c� O 'g chi o '1d 35.813- MAX. 35.813" MAX.DOOR (-- DOOR PANEL WIDTH I PANEL WIDTH 14 a 1 i 0 0 rr, O = w S ral z ' z X ®� 0 0 0 0� o i DOOR PANEL D BOOK "PROFILES" SERIES DOOR PANEL STEEL DOOR SKIN: 24 GA. (0.022' MIN. THICKNESS, Fy = 48,470 PSI MN.J FOAM CORE POLYURETHANE FOAM (1.9 PCF MN.) 41 DOOR PANEL Hybrid Door U Mu w 0 0 0 42 DOOR PANEL Ul or to INTERIOR EXTERIOR STEEL DOOR SKIN 0 BOTTOM RAIL (COMP.) 2 VEIMCAL CROSS SECTION 2 z x-.10112117 +M N.T.S. ` G• BY: JK i K. BY. LFS 3 \WING NO, O FL-23507.9 c xr 2 of 13 " a 9 too rl--'\ HORIZONTAL CROSS SECTION 36Z MAX. DOOR PANEL WIDTH 13 ED m du z z X ®1 0 0 0 0 clz @W PANEL MADMONS"SERIES DOOR PANEL STEEL DOOR SKIN: 25 GA. (0.01 Ir MIN. THICMESS, Fy = 27,830 PSI MN.) FOAM CORE: POLYURETHANE FOAM (13 PCF MN.) 35.813'MAX. 35.813"MAX. DOOR DOOR PANEL WIDTH PANEL WIDTH @=,PANEI gnR PANEL Ul ;r INTERIOR .......... Z, M., cs z o X ':9 If it x zo E. K .4 In v D. 5 A z EXTERIOR &Z N.T.S. JK sn LFS ,WWG NO.: FL-23507.9 V _j3 OF 73 m 0 e5 X SEE HARDWARE CHART Ln m � ��•,' 4f 0 xi ck �d M ay, o * z N'• �� m 6m cO ` u •• o aN (7 x Z, £ Em zm a e Ng So`oa mda� c�"� z° 3- o M ELEVATION X F L j", a c c DAIS 1011211 SCALE: N.T.S. DWG. BY: JK PROPi[ES�ITIONS Steel Door Panel OptlonsSteel Door Panel Options cwc BY: LFS Panel options shown are tot Illustration and are representative only DRAWING No.: (similar opaque panel configurations are allowed) FL-23507.9 SNEEr 4 of 13 l ', p ••� • /• m -TO too v> 01 p Dui v • . z tort 6; • '�. g� 6 m ..... B z /// P UII1 ``�C;`O z o m o o ro z d ills UN•• C �w e.EW X eEn 9o`oa 'md a- $s� o Q Fi ooz O u c „1 p.J 40 41 42 60 61 62 6 1 J� Um EXTERIOR INTERIOR �x �1� VERHCAL CROSS SECTION EMB. (n'P•) W _-En w ZW E 5 stwwnw/?XBuck E o'^ Outswing shown (Inswing similar) ~ �o B 8 o =z C o of U L C a a m O.1SC-SINK 0.1S'C-SINK (— (�) (n'PI L 1 , D eo D Ln a• 6 6 0 INTERIOR INTERIOR o: e n n 23 c � 0 i < W Q F • a IDMIOR EXTERIOR e _ 0 o c 40 41 42 40 41 42 27 z DATE 10 12/17 z 1-1/4'MIN L 29 60 61 62 1 MIN. M„r. N.T.S. `- - EMB-VW.) 60 61 62 EMB. EMB. (TYP.) nwc JK m 2 HORIZONTAL CROSS SECTION 3 HORIZONTAL CROSS SECTION ey: LFS 3 —DRAWM 5 w/ Bck u § Shown w/ 2X Buck NO.: 13 Ou9 mown (Inswing91 Outswing shown (Inswing sunlarj F1-23507.9 0 SHEET 5 OF 13 N 1-1/< EMB. E> o, A e >` I X Buck to be secured to masonry by others rP1 HORIZONTAL CROSS SECTION 65hown w/ I X sub -buck Out—g shown P--v SIrrYW d EXTERIOR ram/ INTERIOR 1 VERTICAL CROSS SECTION 6 Shown w/IXwb•buck Outswing shown (Inswing similar) r31 HORIZONTAL CROSS SECTION 6 Shownw/IXsub-buck Outswing shown (Inswing sIm➢ar) 'MIN. (iYP.) tj I I I ill ��V'' .. o;J=dM z F; O dm \� z U) '•... ' \\\\ Iq N 7IqW OMmZ N •• p a Z o Z U Em e N 9p`oIL v m�� maaf°t o cz � cw c 3d Y Um ti ao OX io ¢o 48(n r z W W � FQ- V F R N OtWi �I O =0 Imflti h t- 10/12 17 i N.T.S. ` 5 BY- JK m c W: LFS 3 �YANC NO.: 0 FL-23507.9 a er --L OF 13 N z I 0 E 1.S MAX. EXTERIOR W KrEWR 1 VERTICAL CROSS SEC77ON 7 Shown D'uect to Manor 6' Ouhwing only w/ 4-9/16 jamb 41� EXTERIOR INTERIOR r4 "\ VERTICAL CROSS SECTION 7 Shown Direct to Masonry Outswing only w/ 6-9/16' jamb is MAX. O O O cDCEFJOR O O I 1 _ r� �1 © ©� L'EMB. PYP.) EMB. (TYP.) ® ,• , . © QHORIZONTAL v'• ' v jambvg only w/ 6-9/16"jamb Direct Outswing• •.jamb INTERIOR 41 42 � N • a w o EXTERIOR E . O i z c M 1-1/4'MIN. onrE:10 12/17 e EMB.(TYP.) sr ic• N.T.S. HORIZONTAL CROSS ICTIONCROSS SECTION DIG, P dK o 7 Shown Direct to Masonry S o Outswing only w/ 6-9/16' jamb o YANG NO.: FL-23507.9 r c SHEET 7 of T 3 n — — 0 Notes 1. S8 Item #'a 17.18, 32. 34, 35, 36, 37, 38 3 39 are attached to Jambs w/ (3) #B X 2-1 /2" pfh screws at each end. S7 Rem ft's 16 & 33 are attached to jambs w/ (2) #8 X 2-1 /T pth screws at each end. Si Item # 15 b attached to jambs uhTmng (2) #10 X T pph screws at each end. INTERIOR —17710//l— EXTERIOR SEE NOTE 1 rl1 VERMAL CROSS SECTION 8 Ir..Q Sip SEE NOTE 1 EXTERIOR r31 VERUCAL CROSS SECHON 1; Outs ft Sil N,16 �0%: INTERIOR nr EXTERIOR SEE NOTE 1 • > C • C � n 4 VERTICAL CROSS SECTION $ High Dam Spl SUM N.T.S. DWO. BY. JK CHK BY.. LFS DPAWV4G ND.: FL-23507.9 SHEET _jL OF 13 j 4" )TYP.) r— 2X BUI O MASONRY (rYP.) 2X BUCK ANCHORING L 2X BUCK J 1XBUCK BUCK M DIRECT TO N MASONRY FRAME -4 HEAD & JAMBS PP.) FRAME ANCHORING )3) #8x2-1/2' PFH WS JAMB TO HEAD DETAIL (TYP.) v QU ^O i�Y � zo S_6J� 6 �mn co i� \\ N h �� Itil U N .. N c E m K Z V mO m dad d E 90 ? ' cw 1 12 DIVE: 10/12 17 i SCALE: N.T.S. ° owc. BY: JK m CHK. BY:. LFS 3 DRAWMO NO.: FL-23507.9 a sHEET 9 OF 13 N EXTERIOR CELLULAR GLAZING TAPE I/T' GLASS BITE I"THK. GLASS 1/8"TEMPERED GLASS I I IT AIR SPACE 0 5/32" ANNEALED GLASS I DOW 995 0.090" PVB INTERLAYER INTERNAL GRID (GBG) WROUGHT IROb OR (SAFLEX OR KURARAY BUTACITE) SIKA 552 1/B"ANNEALED GLASS # 10 X 1-1 /7' PPH SMS 3A SWIGGLE GLAZING SPACER INTERIOR I — I G GLAZING DETAIL �1 Aluminum Impact Lite Frame Door Panels & SideGtes - PRIVACY INSERT j I i i i 20.W' D.L.O. WIDTH I" LAMINATED INSULATED IMPACT GLASS INSERT OPTIONS i O I O O � ' o i j � i -#IOXI-1/7'PPHSMS � ( cTYPa 1� ALUMINUM FRAME 3A Aluminum Impact Lite Frame �P') r!C - d I Door Panels & Siderites "' � ALUMINUM UTE FRAME i I i 1 ISERT fit .�............. ;�v , =UP d z dm 0 z 11*•It V) U N •• o z a Em Z m MO Ne W M S pta a m aa� 8 4 E oz E.-10/12 17 z L N.T.S. ° BY.- N to sr: LFS WING NO, r FL-23507.9 0 Er 11 OF 13 N Z I 0 E Y Z j 1 7.57' 7 5' o X. In m ry iW .0 2�ro 2.36"fill * s, o n a0 z° INSWING THRESHOLD 37 INSWING THRESHOLD 0 a °2 Inswing Basic Composite Adjustable Sill 7-1/7' Inswing Basic i aei 7-1 /7' Sill WOOD JAMB N o E m Z m o o 9cw 6Ln_ mda 4.56" 4.56" 5.83" LL 0 E oZ O c of 33 INSWING THRESHOLD 38 INSWING THRESHOLD 16 OUTSWING THRESHOLD c Insw ng Basic Fixed Sil Inswing Composite Adjustable Sill Composite Sill I o z w O JIL — — 5.75' in w o 5.77' ass" I 0 ' o y � o o O a a INSWING THRESHOLD ' m �•e Inswing Modeate Climate Sill 1-3/(T' INSWING THRESHOLD 39 lnswmg Basic Composite Adjustable SO] 17 OUTSWING THRESHOLD I !, Composite/AluminumS61 5.75' in 0I I m 4 " Illj 5.75' N � INSWING THRESHOLD �— —=; 4.56" —I 35 Inswing Moderate Climate S11 i OUTSWING L C!�� 311 Threshold coastal OUTSWING THRESHOLD US' � I 18 Composite/ kuminumSll 6 a, {fheanal Break) o 2V O h p 1 Z —J_ DAh:10112117 scaiF: N.T.S. 4 u U U U DWG. BY: ,JK' INSWING THRESHOLD i ! t� 1.9T' _ 36 Insw ng Basic Paed 53/a° 51I �i� —1.79" —• I P 2.06" cm ar: LFS PUBLIiACCESSTNRESH0ID 8 SWEEP 9 SWEEP c" �O SWEEP o DRAFL 3 FL-23507.9 1 .MEET 12 av 13 I BILL OF MATERIALS ITEM # DESCRIPTION A 1 X BUCK (SG >= 0.42) B 2X BUCK (SG >= 0.42) C 1/4" MAX. SHIM SPACE D 1 /4" X 2-3/4" PFH ELCO OR ITW CONCRETE SCREW E MASONRY - 3,000 PSI.MIN. CONCRETE CONFORMING TO ACI 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 G 3/16" X 3-1 /4" ITW CONCRETE SCREW J 1 /4" X 3-3/4" PFH ELCO OR ITW CONCRETE SCREW L #10 X 2-1/2" PFH WOOD SCREW (1.15" MIN. EMBEDMENT) M 3/16" X 2-1 /4" ITW CONCRETE SCREW N 3/16" X 2-3/4" ITW CONCRETE SCREW 1 JAMB (FINGER JOINT PINE) 6 WEATHERSTRIP (MEDIUM REACH) 7 WEATHERSTRIP (LONG REACH) 8 SWEEP 9 SWEEP (USE W/ MODERATE CLIMATE THRESHOLD) 10 SWEEP (USE W/ PUBLIC. ACCESS THRESHOLD) 15 PUBLIC ACCESS THRESHOLD 16 OUTSWING THRESHOLD 17 OUTSWING THRESHOLD 18 OUTSWING THRESHOLD 22 #8 x 3/4" PFH WOOD SCREW 23 # 10 x 3/4" PFH WOOD SCREW 24 # 10 x 1" PFH WOOD SCREW G+ BILL OF MATERIALS MATENALI I ITEM # DESCRIPTION WOOD I 1 25 #8 x 2-1/2" PFH WOOD SCREW WOOD j T 26 #8 x 5/8" PFH WOOD SCREW - 1 1 27 LATCH STRIKE PLATE STEEL 28 DEADBOLT STRIKE PLATE (STANDARD) 28A DEADBOLT SUB STRIKE PLATE STEEL ( 1 31 OUTSWING THRESHOLD STEEL j 32 INSWING THRESHOLD . STEEL ! 33 INSWING THRESHOLD STEEL 34 INSWING THRESHOLD WOOD, 1 35 INSWING THRESHOLD 'FOAM j I 36 INSWING THRESHOLD FOAM I I 37 INSWING THRESHOLD VINYL f 38 INSWING THRESHOLD VINYL i 39 INSWING THRESHOLD VINYL i ; 40 DOOR PANEL (BOOK) -" ALUM! 41 DOOR PANEL (HYBRID) - JM/COMPi 42 DOOR PANEL (Ul) -"PRC JM/COMPi 60 DOOR PANEL (BOOK) -" JM/COMPi 61 DOOR PANEL (HYBRID) - STEEL 's 1 62 DOOR PANEL (U1) -'TRA 11 11 ; • o •� MATERIAL n n STEELQ=z s Col, d �'.,7 '' •.-... ����rRrr� i �N n N; n p g.� % o 0 M 0 ° a o E ? m a STEEL STEEL STEEL STEEL STEEL STEEL m o m >3 U: v \ a o R: - UM/COMP UM/COMP UM/COMP UM/COMP CONCRETE ANCHOR NOTES: 1. Concrete anchor locations at the comers may be adjusted to maintain the min. edge distance to morfarjoints. 2. Concrete anchor locations noted as "MAX. ON CENTER" must be adjusted to maintain the min. edge distance to mortarjolnts, additional concrete anchors may be required to ensure the "MAX. ON CENTER" dimension are not exceeded. 3. Concrete anchor table: ANCHOR ANCHOR MIN. MIN .CLEARANCE MIN:CLEA'RANCE TYPE SIZE EMBEDMENT iO MASONRY TOADJA'CENT' EDGE .... ANCHOR' ITW 1/4' 1.1/4" 2" 4" . TAPCON® ELCO 1/4" 1.1/4" i" 4" ULTRACON® ITW ® 3/16" 1.1/4" AS SHOWN 1-1/2" TAPCON WOOD SCREW INSTALLATION NOTES: 1. Maintain a minimum 518" edge distance, I"end distance, & I" o.c. spacing of wood screws to prevent the splitting of wood. DATE: 10/12/17 SCALE: N.T.S. owc. er: X CHK.6r: LFS DNAWING No.: ' i `FL-23507.9 � sHEET 13 or 13