Loading...
HomeMy WebLinkAboutSewage; Septic Tank ElevationsPERMIT #:56-SF-I842183 APPLICATION #:AP1341182 STATE OF FLORIDA DATE PAID: DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL FEE PAID: SYSTEM � l= / �,�/� S RECEIPT #: DOCUMENT #: PR1119801 RECEIVED CONSTRUCTION PERMIT FOR: APPLICANT: John PROPERTY ADDRESS: OSTDS New AUG ®2 2018 TSD Admiral St Fort Pierce, FL 34981 l ST Lucie County, Permittin LOT: 22 BLOCK•. 6 SUBDIVISION: Maraviila Gardens [SECTION, TOWNSHIP, RANGE, PARCEL NUMBER] PROPERTY ID #: 2421-802-0074-000-0 [OR TAX ID NUMBER] SYSTEM MUST BE CONSTRUCTED IN ACCORDANCE WITH SPECIFICATIONS AND STANDARDS OF SECTION 381.0065, F.S., AND CHAPTER 64E-6, F.A.C. DEPARTMENT APPROVAL OF SYSTEM DOES NOT GUARANTEE SATISFACTORY 'PERFORMANCE FOR ANY SPECIFIC PERIOD OF TIME. . ANY CHANGE IN MATERIAL FACTS, WHICH SERVED AS A BASIS FOR ISSUANCE OF THIS PERMIT, REQUIRE THE APPLICANT TO MODIFY THE PERMIT APPLICATION. SUCH MODIFICATIONS MAY RESULT IN THIS PERMIT BEING MADE NULL AND VOID. ISSUANCE OF THIS PERMIT DOES NOT EXEMPT THE APPLICANT FROM COMPLIANCE WITH OTHER FEDERAL, STATE, OR LOCAL PERMITTING REQUIRED FOR DEVELOPMENT OF THIS PROPERTY, SYSTEM DESIGN AND SPECIFICATIONS T [ 900 j GALLONS / GPD Senfic new CAPACITY A [ j GALLONS / GPD N/A CAPACITY N [ J GALLONS GREASE INTERCEPTOR CAPACITY [MAXIMUM CAPACITY SINGLE TANK:1250 GALLONS] K [ ] GALLONS DOSING TANK CAPACITY [ ]GALLONS @[ ]DOSES PER 24 HRS #Pumps [ ] D [ 500 ] SQUARE FEET Drainfield new SYSTEM R [ .] SQUARE FEET N/A SYSTEM A TYPE SYSTEM: [ ] STANDARD [x] FILLED [ ] MOUND. [ ] I CONFIGURATION: [ j TRENCH [•X] BED [ ] N F LOCATION OF BENCHMARK: Orange painted Nail in W side of Admiral St center of property J ` I E L D 0 T H E R L REQUIRED 13.001 INCHES EXCAVATION REQUIRED: [ 13.UU] INCtwtj ie system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total: estimated flow of . 0 gpd. ie licensed contractor installing the system is responsible for installing the minimum category of tank in.accordance with 64E-6.013(3)(f), FAC. FILE COPY SPECIFICATIONS BY: A Brian J Ingrpiq TITLE' Environmental Specialist II APPROVED BY: or. I : Environmental Specialist II St. Lucie CBD Brian J Ingr DATE ISSUED: 06l0412018 EXPIRATION DATE: 12/04/2019 DR 4016, 08109 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC c Page 1 of 3 1.1.4 AP1341182 SE1080005 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION PERMIT FOR: OSTDS New APPLICANT: John George PROPERTY ADDRESS: TBD Admiral St Fort Pierce, FL 34981 LOT: 22 BLOCK: 6 SUBDIVISION PROPERTY ID #: 2421-802-0074-000-0 Maravilla Gardens PERMIT #: 56-SF-1 842183 APPLICATION #: AP1341182 DATE PAID: FEE PAID: RECEIPT #: DOCUMENT #: PR1119801 [SECTION, TOWNSHIP, RANGE, PARCEL NUMBER] [OR TAX ID NUMBER] ro SYSTEM MUST BE CONSTRUCTED IN ACCORDANCE WITH SPECIFICATIONS AND STANDARDS OF SECTION 381 '00.65, F.S., AND CHAPTER 64E-6, F.A.C. DEPARTMENT APPROVAL OF SYSTEM DOES NOT GUARANTEE .kATISFACTORY PERFORMANCE FOR ANY SPECIFIC PERIOD OF TIME. ANY CHANGE IN MATERIAL FACTS, WHICH SERVED AS A BASIS FOR ISSUANCE OF THIS PERMIT, REQUIRE THE APPLICANT TO MODIFY THE 'PERMIT APPLICATION. SUCH MODIFICATIONS MAY RESULT IN THIS PERMIT BEING MADE NULL AND VOID. :a ISSUANCE OF THIS PERMIT DOES NOT EXEMPT THE APPLICANT FROM COMPLIANCE WITH OTHER FEDERAL, STATE, OR LOCAL PERMITTING REQUIRED FOR DEVELOPMENT OF THIS PROPERTY. SYSTEM DESIGN AND SPECIFICATIONS T [ 900 ] GALLONS / GPD SeDtic new CAPACITY A [ j GALLONS / GPD N/A CAPACITY N [ ] GALLONS GREASE INTERCEPTOR CAPACITY [MAXIMUM CAPACITY SINGLE TANK:1250 GALLONS] K [ ] GALLONS DOSING TANK CAPACITY [ ]GALLONS @[ ]DOSES PER 24 HRS #Pumps [ D [ 500 ] SQUARE FEE! R [ ] SQUARE FEE! A TYPE SYSTEM: [ ] I CONFIGURATION: [ ] N F LOCATION OF BENCHMARK: Drainfield new SYSTEM N/A SYSTEM STANDARD [x] FILLED [ ] MOUND TRENCH [x] BED [ ] Orange painted Nail in W side of Admiral St center of I ELEVATION OF PROPOSED SYSTEM SITE [ 1.00 ][ INCHES FT ][ ABOVE BELOW] BENCHMARK/REFERENCE POINT E BOTTOM OF DRAINFIELD TO BE [ 4.00 ][ INCHES FT ][ABOVE BELOW BENCHMARK/REFERENCE POINT L D FILL REQUIRED: 113.001 INCHES EXCAVATION REQUIRED: [ 13.00] INCHES The system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total. estimated flow of 0 300 gpd. T The licensed contractor installing the system is responsible for installing the minimum category of tank in:accordance with H s. 64E-6.013(3)(f), FAC. E R SPECIFICATIONS BY: Brian J Ing T1TLr:: Environmental Specialist II APPROVED BY: ITLE: Environmental Specialist II St. Lucie CHD Brian a Ingr DATE ISSUED: 06/04/2018 EXPIRATION DATE: 12/04/2019 DR 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 1 of 3 v 1.1,9 AP1341182 SE1080005 y NOTICE OF RIGHTS A party whose substantial interest is affected by this order may petition for an administrative hearing pursuant to sections 120.569 and 120.57, Florida Statutes. Such proceedings are governed by Rule 28-106, Florida Administrative Code. A petition for administrative hearing must be in writing and must be received by the Agency Clerk for the Department, within twenty-one (21) days from the receipt of this order. The address of"the Agency Clerk is 4052 Bald Cypress Way, BIN A-02, Tallahassee, Florida 32399. The Agency Clerk's facsimile number is 850-413-8743. Mediation is not available as an alternative remedy. Your failure to submit a petition for hearing within 21 days from receipt of this order will constitute a waiver of your right to an administrative hearing, and this order shall become a 'final .order'. Should this order become a final order, a party who is adversely affected by it is entitled to judicial review pursuant to Section 120.68, Florida Statutes. Review proceedings are governed by the Florida Rules of Appellate Procedure. Such proceedings may be commenced by filing one copy of a Notice of Appeal with the Agency Clerk of the Department of Health and a second copy, accompanied by the filing fees required by law, with the Courtof Appeal in the appropriate District Court. The notice must be filed within 30 days of rendition of the final order. St. Lucie County Health Department 5150 NW Milner Dr Port Saint Lucie, FL 34983. PAYING ON: PERMIT #: 56-SF-1842183 BILL Doc #:56-BID-3722981 CONSTRUCTION APPLICATION #: AP1341182 RECEIVED FROM: Georqe and Associates AMOUNT PAID: $ 515.00 PAYMENT FORM: CHECK 5778 PAYMENT DATE: 04/25/2018 MAIL TO: John George 93 q- 'f Oo 9 �- LIS-o— T(o3"7 FACILITY NAME: PROPERTY LOCATION: TBD Admiral St Fort Pierce, FL 34981 Lot: 22 Block: 6 Property ID: 2421-802-0074-000-0 EXPLANATION or DESCRIPTION: QUANTITY FEE 128 - OSTDS Construction System Inspection Research Fee 1 $ 5.00 -1 - OSTDS New Permit Surcharge 1 $ 100.00 -1 - OSTDS Construction Application and Plan Review,New 1 $ 100.00 123 - OSTDS Construction Site Evaluation 1 $ 115.00 126 - OSTDS Construction Permit (New or Mod, Amendment) 1 $ 55.00 127 - OSTDS Construction System Inspection 1 $ 75.00 133 - OSTDS Construction Reinspection 1 $ 50.00 -1 - Surcharge (All) 1 $ 15.00 RECEIVED BY: VanceMH AUDIT CONTROL NO. 56-PID-3523353 Y 4 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM �OpWE APPLICATION FOR CONSTRUCTION PERMIT APPLICATION FOR: PERMIT NO. DATE PAID: FEE PAID: �s RECEIPT #: l [v/] New System [ ] Existing System [ ] Holding Tank [ ] Innovative [ ] Repair [ ] Abandonment [ ] Temporary [ ] APPLICANT: John George AGENT: George and Associates - Contractor TELEPHONE: 772-834-7001 of MAILING ADDRESS: 786 Bent Creek Drive, Fort Pierce FL 34947 01. , 4} (6,37 TO BE COMPLETED BY APPLICANT OR APPLICANT'S AUTHORIZED AGENT. SYSTEMS MUST BE CONSTRUCTED BY A PERSON LICENSED PURSUANT TO 489.105(3)(m) OR 489.552, FLORIDA STATUTES. IT IS THE APPLICANT'S RESPONSIBILITY TO PROVIDE DOCUMENTATION OF THE DATE THE LOT WAS CREATED OR PLATTED (MM/DD/YY) IF REQUESTING CONSIDERATION OF STATUTORY GRANDFATHER PROVISIONS. PROPERTY INFORMATION LOT: 22 BLOCK: 6 SUBDIVISION: MARAVILLA PLAZA PLATTED: PROPERTY ID #: 2421-802-0074-000-0 ZONING: I/M OR EQUIVALENT: [ Yes ] • PROPERTY SIZE: ACRES WATER SUPPLY: [ l PRIVATE PUBLIC [✓ ]<=2000GPD [ 1>2000GPD IS SEWER AVAILABLE AS PER 381.0065, FS? [ Yes ] DISTANCE TO SEWER: FT PROPERTY ADDRESS: TBD Admiral Street. DIRECTIONS TO PROPERTY: Next to 2980 Admiral Street on south side BUILDING INFORMATION [✓] RESIDENTIAL [ ] COMMERCIAL Unit Type of No. of Building Commercial/Institutional System Design No Establishment Bedrooms Area Sqft Table 1, Chapter 64E-6, FAC 1 Single 3 2,1.641- P-� 23 I-- IA Z 2 3 4 [ ] Floor/Equipment Drains SIGNATURE: DH 4015, 08/09 (Obsolet Incorporated 64E-6.001, [ ] Other (Specify) editions which may not be used) DATE: 4/24/18 Page 1 of 4 r 'Y STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM SITE EVALUATION AND SYSTEM SPECIFICATION APPLICANT: John George CONTRACTOR / AGENT: George and Associates LOT: 22 BLOCK: 6 SUBDIVISION: Maravilla Gardens ID#: 2421-802-0074-000-0 APPLICATION # API341182 PERMIT # 56-SF-1842183 • DOCUMENT # SE1080005 TO BE COMPLETED BY ENGINEER, HEALTH DEPARTMENT EMPLOYEE, OR OTHER QUALIFIED PERSON. ENGINEERS MUST PROVIDE REGISTRATION NUMBER AND SIGN AND SEAL EACH PAGE OF SUBMITTAL. COMPLETE ALL ITEMS. PROPERTY SIZE CONFORMS TO SITE PLAN: [XIYES [ ]NO NET USABLE AREA AVAILABLE: 0.29 ACRES TOTAL ESTIMATED SEWAGE FLOW: 300 GALLONS PER DAY [ I RESIDENCES -TABLET / OTHER -TABLE 2 ] AUTHORIZED SEWAGE FLOW: 724.98 GALLONS PER DAY [ 1500 GPD/ACRE OR 2500 GPD/ACRE ] UNOBSTRUCTED AREA AVAILABLE: 1099.00 SQFT UNOBSTRUCTED AREA REQUIRED: 750.00 SQFT BENCHMARK/REFERENCE POINT LOCATION: Orange painted Nail in W side of Admiral St center of ELEVATION OF PROPOSED SYSTEM SITE 1.00 [I INCHES I/ FT ] [IABOVEI/ BELOW ] BENCHMARK/REFERENCE POINT THE MINIMUM SETBACK WHICH CAN BE MAINTAINED FROM THE PROPOSED SYSTEM TO THE FOLLOWING FEATURES SURFACE WATER: FT DITCHES/SWALES: FT NORMALLY WET: [ ]YES [X]NO WELLS: PUBLIC: FT LIMITED USE: FT PRIVATE: FT NON -POTABLE: FT BUILDING FOUNDATIONS: 5 FT PROPERTY LINES: 5 FT POTABLE WATER LINES: 55 FT SITE SUBJECT TO FREQUENT FLOODING? [ ]YES [X]NO 10 YEAR FLOODING? [ ]YES IXINO] 10 YEAR FLOOD ELEVATION FOR SITE: FT[ MSL / NGVD ] SITE ELEVATION: FT [ MSL / NGVD QnTT. DLnT'. TT.r- TWVn12MAmTnA QTT12 1 ROTT. PROFTLR INFORMATION SITE 2 USDA SOIL SERIES:Pepper sand Munsell #/Color Texture Depth 10YR 4/3 Fill - Loamy Sand 0 To 11 10YR 4/1 Sand 11 To 23 10YR 5/1 Sand 23 To 35 10YR 6/1 Sand 29 To 44 1 OYR 4/4 Fine Sand 44 To 52 10YR 5/4 Fine Sand 52 To 72 USDA SOIL SERIES:Pepper sand Munsell #/Color Texture Depth 1OYR 4/3 Fill - Loamy Sand 0 To 13 10YR 4/1 Sand 13 To 24 . 1 OYR 5/1 Sand 24 To 36 10YR 6/1 Sand 36 To 47 1 OYR 4/4 Sand 47 To 51 10YR 5/4 Sand 51 To 63 HOLE CAVING' Refusal 63 To 72 OBSERVED WATER TABLE: 35.00 INCHES [ ABOVE / BELOW ] EXISTING GRADE TYPE: [ PERCHED / APPARENT ] ESTIMATED WET SEASON WATER TABLE ELEVATION: 29 INCHES [ ABOVE / BELOW ] EXISTING GRADE HIGH WATER TABLE VEGETATION: [ ]YES [X]NO. MOTTLING: [X]YES [ ]NO DEPTH: 29.00 INCHES SOIL TEXTURE/LOADING RATE FOR SYSTEM SIZING: Sand/0.60 DEPTH OF EXCAVATION: 13 INCHES DRAINFIELD CONFIGURATION: [ ] TRENCH [X] BED [ ] OTHER (SPECIFY) REMARKS/ADDITIONAL CRITERIA WSWT determined using USDA WSS and soil borings. 10YR6/1 stripping in 10YR5/1 matrix >10% w/ diffuse boundaries starting at 29" in SB1. SB1 1" above BM. SB2 2" above- . SITE EVALUATED BY: DATE: 05/18/2018 Ingram, Brian (Title:'Environ ntal Specialist II) (ENVIRONMENTAL HEALTH) DR 4015, 08/09 (Obsoletes previous editions which may n bs used) Incorporated: 64E-6.001, FAC Page 3 Of 4 AP1341182 EID1842183 v 1.0.2