HomeMy WebLinkAboutEngineeringDESIGN CRITERIA: APPLICABLE CODES, REGULATIONS & STANDARDS 1. THE 2017 FLORIDA BUILDING CODE, SPECIFICALLY CHAPTER 16 STRUCTURAL DESIGN, CHAPTER 20 ALUMINUM & CH. 23 WOOD. 2. AA ASM 35 & SPECIFICATIONS FOR ALUMINUM STRUCTURES, PART 1-A OF THE ALUMINUM DESIGN MANUEL PREPARED BY THE ALUMINUM ASSOCIATION, INC. WASHINGTON D.C. 2005 ED. 3. ASCE 7-10 & SE17 4. NDS NATIONAL DESIGN SPECIFICATION FOR WOOD. 5. AC1318 CONCRETE REFRENCE MANUAL. WIND LOADS 1. BUILDING OCCUPANCY CATEGORY, PARAGRAPH 1604.5 & TABLE 1604.5: RISK CATEGORY 1. 2. BASIC WIND SPEED, TABLE 1609C, STATE OF FLORIDA DEBRIS REGION & BASIC WIND SPEED, PARAGRAPH 1609.3.1 & TABLE 1609.3.1 EQUIVALENT BASIC WIND SPEED: 150 MPH EXPOSURE CATEGORY, PARAGRAPH 1609.4.3: _ C 3. WIND LOADS PER FBC TABLE 2002.4 (MWFRS) VULT = 150 MPH & EXPOSURE = C FOR 20 X 20 X 0.013" MESH SCREEN HORIZONTAL PRESSURES ON WINDWARD SURFACES = 43 PSF HORIZONTAL PRESSURES ON LEEWARD SURFACES = 34 PSF VERTICAL PRESSURES ON SCREEN SURFACES = 12 PSF VERTICAL PRESSURES ON SOLID SURFACES = 36 PSF FOR 18 X 14 X 0.013" MESH SCREEN, APPLIED FACTOR = .88 FOR ALLOWABLE STRESS DESIGN, APPLIED FACTOR = •6 FOUNDATION DESIGN FOOTING SIZE EXISTING CONCRETE SLAB. NO ADDITIONAL FOOTING OR FOUNDATION SYSTEM IS REQUIRED BY THE PROPOSED CONSTRUCTION IF A MINIMUM 4" CONCRETE SLAB IS PROVIDED IN SOUND CONDITION, FREE FROM STRUCTURAL CRACKING, SPALLING & OTHER DETERIORATION. EXISTING FOUNDATION/FOOTING UNDER CONCRETE SLAB MINIMUM 8"x8" W/ (1) #5 BAR TO BE VERIFIED BY CONTRACTOR. SEE TYPICAL FOOTING DETAILS FOR NEW FOOTING DESIGN MINIMUM REQUIREMENTS. SPECIFICATIONS THE FOLLOWING SPECIFICATIONS ARE APPLICABLE TO THIS PROJECT: 1. WHERE CONCRETE SPECIFICATIONS ARE REQUIRED, WHETHER IN THE SCREEN ENCLOSURE SCOPE OF NOT, BY ONE OR MORE REGULATORY AGENCY, THE FOLLOWING SPECIFICATIONS ARE APPLICABLE: a. CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING COMPONENTS: i. PORTLAND CEMENT TYPE 1 - ASTM C 150 ii AGGREGATES - LARGE AGGREGATE 3/4 MAX. - ASTM C 33 iii. AIR ENTRAINING +/- 1 %- ASTM C 260 iv. WATER REDUCING AGENT - ASTM C 494 v. CLEAN PORTABLE WATER vi. OTHER ADMIXTURES NOT PERMITTED b. METAL ACCESSORIES SHALL CONFORM TO: i. REINFORCING BARS - ASTM A615, GRADE 60 ii. WELDED WIRE FABRIC - ASTM A185 c. CONCRETE SLUMP AT DISCHARGE CHUTE NOT LESS THAN 3" OR MORE THAN 5". WATER ADDED AFTER BATCHING IS NOT PERMITTED. d. PREPARE & PLACE CONCRETE PER AMERICAN CONCRETE INSTITUTE MANUAL OF STANDARD PRACTICE, PART 1, 2, & 3 INCLUDING HOT WHEATHER RECOMMENDATIONS. e. MOIST CURE OR POLYETHYLENE CURING PERMITTED. f. PRIOR TO PLACING CONCRETE, TREAT THE ENTIRE SUBSURFACE ARE FOR TERMITES IN COMPLIANCE WITH THE FBC. g. CONCRETE SHALL BE PLACED OVER A POLYETHYLENE VAPOR BARRIER. 2. WHEN PAVERS ARE UNDER ALUMINUM MEMBERS, CONTRACTOR SHALL EPDXY TO DECK OR GROUT TO DECK w/3000 PSI GROUT WITH BONDING AGENT 3. WHEN APPLICABLE FOR NEW SLAB ADDITION TO ADJACENT DRILL & EPDXY #5 X 8" REBAR INTO EX. FOUNDATION WITH 1" MIN. HOLE, EMBED 4" MIN W/ NON -SHRINKING SIMPSON EPDXY -TIE (OR EQUAL) 48" O.C. TYP. ALL LOCATIONS 4. WHEN APPLICABLE FOR NEW FOOTER TO EXISTING, DRILL & EPDXY NEW STEEL INTO EX. FOUNDATION WITH 1" MIN. HOLE, EMBED 6" MIN W/ NON -SHRINKING SIMPSON EPDXY -TIE (OR EQUAL) TYP. ALL LOCATIONS 5. MINIMUM CONCRETE STRENGTH 3000 PSI UNLESS OTHERWISE NOTED. ALUMINUM SPECIFICATIONS ALUMINUM MEMBERS DIMENSIONS 1. ALUMINUM EXTRUSIONS SHALL BE 6005 T5 ALLOY UNLESS OTHERWISE NOTED. HOLLOW SECTIONS 2. ALL SELF MATING BEAM SECTIONS ARE TO BE STITCHED WITH 2 x 2: 2" x 2" x 0.050" ## 12 SCREWS 6" FROM ENDS & 24" CENTER TO CENTER. 2 x 3: 2" x 3" x 0.050" 3. ROOF BRACING SHALL BE A MINIMUM 2"X2"X.050". 2 x 4: 2" x 4" x 0.050" 4. THE MINIMUM NORMAL THICKNESS OF PROTECTOR PANELS 2 x 5: 2" x 5" x 0.050" (KICKPLATES) SHALL BE AN INDUSTRY STANDARD OF 0.024 INCHES. OPEN BACK SECTIONS 5. VINYL AND ACRYLIC PANELS SHALL BE REMOVED WHEN 1 x 2: 1" x 2" x 0.044" WIND SPEEDS EXCEED 75 MPH PER FBC. 1 x 3: 1" x 3" x 0.045" 6. SCREEN MATERIAL SHALL BE 18/14 SCREEN UNLESS APPROVED BY FLORIDA ENGINEERING LLC. SNAP SECTIONS 5. 1"X2" & 1"X3" NON STRUCTURAL MEMBERS MAY BE USED 2 x 2 SNAP: 2" x 2" x 0.045" INTERCHANGEABLY. 2 x 3 SNAP: 2" x 3" x 0.050" 2 x 4 SNAP: 2" x 4" x 0.045" FASTENER SPECIFICATIONS 1. FASTENERS ARE REQUIRED TO BE SAE GRADE 2 OR BETTER ZINC PLATED. (CONCRETE ANCHORS ARE TO BE TAPCONS OR BETTER, INSTALLED TO MFG. SPECIFICATIONS) 2. IT IS THE OWNERS RESPONSIBILITY TO MAINTAIN THE SCREENS, FASTENERS AND SCREENS TO MANUFACTURING SPECIFICATIONS. 3. WHERE WOOD DECK IS PRESENT USE 1 /4" X 3-1/2" GALV. LAG SCREWS IN LIEU OF MASONRY ANCHORS. UNLESS OTHERWISE SPECIFIED. 4. 1"X2" NON STRUCTURAL MEMBERS ATTACHED TO HOST A. FOR MASONRY/CONCRETE APPLICATION USE GALVANIZED 1 /4" X 2-3/4" TAPCONS OR EQUAL AT 24" O.C. AND 6" FROM ENDS B. FOR WOOD APPLICATION USE # 14 X 2-3/4" WOOD SCREW AT 24" O.C. AND 6" FROM ENDS. C. FOR ALUMINUM APPLICATION USE # 10 X 1-1 /2" SMS OR TEK SCREW AT 24" O.C. AND 6" FROM ENDS D. WHERE 1 "X2" INSTALLED THROUGHOUT AN "OPEN VIEW' SPACING SHALL BE REDUCED TO 18" O.C. AND 6" FROM ENDS MASONRY SPECIFICATIONS _ 1. CONCRETE MASONRY UNITS (CMU) SHALL BE STANDARD HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON TYPE M OR S MORTAR. 2. ALL MORTAR SHALL BE TYPE M OR S. 3. ALL GROUT SHALL BE 2000 PSI MINIMUM AND HAVE MAXIMUM COARSE AGGREGATE SIZE OF 3/8". 4. PROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING REINFORCEMENT WHEN GROUT POUR EXCEEDS 5'-0" IN HEIGHT. MISCELLANEOUS 1. SCREENED ENCLOSURES CONTAINING SWIMMING POOLS SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF FBC R4501.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS. 2. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME, IF THE EXISTING STRUCTURE IS ONE OF THESE, A SEPERATE 4TH WALL SUPPORT SYSTEM IS SO TO BE ENGINEERED SO THAT NO ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED HOME. 3. DOOR LOCATION MAY BE RELOCATED BY CONTRACTOR IN THE FIELD. 4. WHERE PAVERS ARE UNDER ALUMINUM MEMBERS, CONTRACTOR SHALL EPDXY TO DECK OR GROUT TO DECK w/3000 PSI GROUT WITH BONDING AGENT. 5. INTEGRITY OF EXISTING/ HOST STRUCTURE SHALL NOT BE COMPROMISED WITH THE ATTACHMENT OF THE PROPOSED STRUCTURE. 6. ALL 2X4 & GREATER ARE TO BE 2 x 4 SMB: 2"x4"x0.044"x0.100" UNLESS OTHERWISE INDICATED. RESPONSIBILITIES 1. ALL SITE WORK SHALL BE PERFORMED BY A LISCENED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDANANCES, AND THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES. 2. FOR FASTENERS WHICH ARE NOT VISIBLE AFTER INSTALLATION, THE CONTRACTOR SHALL VERIFY AND ENSURE INSTALLATION HAS BEEN ACCOMPLISHED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS AND IN ACCORDANCE WITH THE ATTACHED DETAILS. 3. FOR "PICTURE WINDOW" MODIFICATION TO EXISTING SCREEN ENCLOSURES, ALL OTHER "EXISTING SCREEN ENCLOSURE" FEATURES ARE TO MEET THE TYPICAL DETAILS AS PROVIDED IN THESE DETAILS. CONTRACTOR IS TO VERIFY & ASSURE EXISTING SCREEN ENCLOSURE IS STRUCTUALLY SOUND. SELF MATING (SMB) 2 x 4 SMB: 2" x 4" x 0.046" x 0. 100" 2x5SMB: 2"x5"x0.050"x0.116" 2 x 6 SMB: 2" x 6" x 0.050" x 0. 120" 2 x 7 SMB: 2" x 7" x 0.055" x 0. 120" 2x8SMB: 2"x8"x0.072"x0.224" 2 x 9 SMB: 2" x 9" x 0.072" x 0.224" 2x9(H) SMB: 2" x 9" x 0.082" x 0.306" 2 x 10 SMB: 2" x 10" x 0.092" x 0.374" DETAIL A s t= U " p' di co co Q O U ry 0.2 0�a LL Lo M � � N Q 0 F- �' 0 n f`- 00 d' N O N 0 z 0 w 0 ry n U U = J J � � z z z W w 0 J E - LL ry W W w ry o QZU LL! o z a 0 0 OLoQ CL - J-d z O o a DESIGN DATE: 09/09/2020 REVISION 1: DATE REVISION 2: DATE PAGE: DRAWN BY: TCP SCALE: NTS 0 1X3 2X3 DJ 2X3 DJ 0 bo 4X4X.125 m u 00 \ N 1X3 8'-6" CD N 2X3X.050 DIAG. BRACE TYP. ------- :v u • `, HOST 12" O/H STRUC. GUTTER - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- -- - - - - - - ------------ ------------ - ----Y 2X3 TYP. co 2 ur) co 2 N cn 2 V) co 2 N co �i N m 2 V) x N X N X N x N N N L N N 2X3 TYP. I-7'-9" --7'-9" -�-7'-9" �7'-9" 7'-9"--- -7'-9" 7'-9" -r- —7-9" -I 4'-0" MAX. i I I t I i i `. 2X10 SMB C.B. 2X10 SMB C.B. N � X lD / X `. 1X3 TYP. ,' 1X3 TYP. 3'-0" -� 1X3 -� 2X3 DJ 2X3 DJ r r r r r r 2X5SMB o O I � N O rn co + X m X N co N X _Q I� I i � 2X5SMB \ o 1X3 I 8'-6" o. m . IIJ nl o J 00 o JT rn o F- cy o' �r z Q E LLJ L � 0 O U ry cl� O (J LL O Go - W Q J 0) L - Lo zr ' L W � a' M O't W Q a) ry Q ono 00 H o �I ry U U = 07 J J m z z W W <L OD W w ry o QZU W o z a 75 Q O c) 0 Lr) a - J—d z O O Of � a DESIGN DATE: 09/09/2020 REVISION 1: DATE REVISION 2: DATE PAGE: DRAWN BY: TCP SCALE: NTS FLASHING 'HORIZONTAL OR SLOPED 'x2FASTEN TO CO" (INTERNAL) WN2) ox U2 SMSFASTEN 0 EAVE RAILS 4sovc N- #Iox r2 S, 5 26' O.C. AND 6" FROM END. - — o TABLE "D° f ° BEAM QTY EACH SIDE/SIZE_ _ 2 x� 4/12 — 2 x 4 5112 2 x 5 5/12 2 x 6 6/12 2 x 7 7112 2 x 8 8/14 2 x 9 9/14 2 x 10 9l14 MA,NTAIN MIN, OF 5r8" SEPERATION FROM EDGE OF BEAM SMS O.C. TYP. NOTE- IF PAVERS ARE PRESEMIT, CONCRETE ANCHORS SHALL PENETRATE INTO FOOTING 2-11L" MIN. (TYP.) NOTE: WHEN FASTENING TO WOOD USE I/[." GALL. LAG SCREW IN LIEU OF CONC. ANCHORS AND ENSURE PENETRATION MIN 2-11L" INTO 5 TRUCTURAL FRAMING BPP E'TH (TYP_) o 0 Tio 0 o �- BEAM PER PLAN NOT TO RECEIVE INTO BE; CO_UMP: WITHIN BEAM SMS. (EACH SIDE) QTY PER TABLE D NOTCH PROFILE MAY VARY TO PERMIT CORRECT # SMS NST ALL E IF TO CGR!VE COLUMN PER PLANS DETAIL "E" - UPRIGHT TO BEAM CONNECTION SCALE: N.T.S. 1/4' DIA. TAPCON SCHEDULE UPRIGHT QTY. TAPCON/ QTY. #12 SMS E/S 2X3 (1) 1/4" TAPCON/ (4) #12 2X4 (2) 1/4" TAPCON/ (4) #12 2X5 (2) 1/4" TAPCON/ (4) #12 2X6 (3) 1/4" TAPCON/ (6) #12 2X7 (3) 1/4" TAP_CON/ (6) #12 2X8 (4) 1/4" TAPCON/ (8) #12 2X9 (4) 1/4" TAPCON/ (8) #12 2X10 (5) 1/4" TAPCON/ (10) #12 SCHEDULE BASED ON 2-1/4` MIN. CONCRETE ANCHOR EMBEDMENT 118'x2'x2'x ANGLE 5032 H-32 ANGLE (2) 912 SMS INTO COLUMN /L" MASONRY ANCHOR EACH ANGLE EACH SDE COL 2 1/L° MIN. CONC. ANCHOR EMBEDMENT d ° d 3000 PSI CONC. SLAB/ FTG. 6x6-i0xI0 WYlM OR FIBERMESH 114' MASONRY ANCHOR AT EACH ANGLE — 3/8" DIA. TAPCON SCHEDULE UPRIGHT QTY. TAPCON/ OTY. #12 SMS EIS 2X3 (1) 3/8" TAPCON/ (4) #12 2X4 (2) 3/8" TAPCON/ (4) #12 2X5 (2) 3/8" TAPCON/ (4) #12 2X6 (2) 3/8" TAPCON/ (6) #12 2X7 (2) 3/8" TAPCON/ (6) #12 2X8 (3) 3/8" TAPCON/ (6) #12 21 X9 (3) 3/8" TAPCON/ (6) #12 2XIO (4) 3/8" TAPCON/3/8" TAPCON/ (8 (2) #I0x3" SMS INTO SCREW BOSSES FOR EDGE MEMBER I; EDGE `"E"18ER o ° 0 ° OR PURLIN 00 II ! EDGE MEMBER _ OR PURLIN DETAIL "D" - ROOF BRACING CONNECTION SCALE: N.T.S. SCHEDULE BASED ON MIN. CONCRETE ANCHOR EMBEDMENT SELF -MATING OR I / SNAP SECTION TYP. PER PLAN I"x20.8- BASE PLATE-TYP. i i I I/L" (-'(N LONG ANCHOR EMBEDMENT i 2- MIN, AP CHOR SPACING WHEN GREATER THAN 2x4 a " UPRIGHT IS USED SEE TAPCON SCHEDULE ABOVE 2-#12 SMS 1/4' TAPCON XL (RED HEAD MFG. OR EQUAL) 2 @ Ix2 BASE 2 @ SLAB (BEYOND) 1x2' BASE PLATE ANCHORED TO CONC w/ i!L" MASONRY ANCHOR 6" MAX EACH SIDE • • n ° OF POST AND 24" O.C- MAX 3000 PSI CONC, SLAB,' FTG. 6x6-IoxW WWM FRONT VIEW OR FIBERMESH DETAIL "B" - 2"x4" OR LARGER SELF MATING UPRIGHT TO DECK DETAILS SCALE: N.T.S. ALUMINUM NUM INTERNAL Rr A OR EXTERNAL RECEIVING CHANNEL v!( ) 10 . INTO GIRT OR PURLIN 8 (2) L _ INTO BEAM OR UPRIGHT 0,062 ' [NGL CLIPS MAYBE LStJ (L) #10x2' SMS INTO SCREWBOSSES 0.0625" 6063 6 FLAT PLATE W1(8) #IOx3IL" SMS, MIN. 1!2" EDGE DISTANCE, PLATE MAY BE i FASTE(ED INTERNALLY TO BRACE PURLIN UPRIGHT, BEAM -SNAP, t1EM6PR SELF MATING,OR HOLLOW CI DETAIL "C" - GIRT OR PURLIN TO BEAM OR POST DETAIL SCALE: N.T.S. 'ALL MEMBERS PER PLAN PAGE 2 2'x2"x.063" - DIM. TO MATCH FURLIN +EMBERS VARY PER PLAN PAGE 2 SIZE RECEIVINGCHANNEL (2) #12 SMS INTERNAL ERNAL TO EA`JE — —i RAIL (3) #12 EACH SIDE INTO PURLIN H'STEr 'TOP 0� ADE" TO INTERSECTING la 'j 1 MEMBER w�(2) "10- SMS wl" PENETRATION INTO SCREW BOSS OF I E'V- RAIL - SEE PLAN - MEMBER - TYP. BOTH SIDES i Ix2 OPEN BACK EXTRUSION COOR JAMB PER PLAN III I' FASTEN HEADER w/(2) #10x3` I I INTO SCREW BOSS 0, HEADER ALTERNATE HEADER CONNECTION WHEN Z-BAR IS USED - FASTEN Z-BAR TO COL/HEADER AT EACH CORNER AND 18" 0!C ALTERNATE BASE PLATE CONNECTION ATTACH MEMBER TO BASE PLATE (INTERNAL) w1(2) #I0x2' SMS ATTACH BASE PLATE TO MEMBER W112) #IOx3" SMS INTO SCREW BOSS OF BASE PLATE d ° ° ° ° ° a L d ° a ° ° ° °d n ° °6 a ° ° ° a G J' ° d ° ° ° a ° n ° ° ° d � a d 1/4' TAPCON (RED HEAD MFG. OR EQUAL) WITHIN 6" OF COLUMN 8 2L' O.C. MAX. 1-1/4' PENETRATION INTO UNDERLYING FOOTING DETAIL "F" - DOOR JAMB 81 HEADER CONNECTION SCALE: N.T.S. a` uj a �s .n .. s R ' t a `o Q . a, a . t0 i Jo o }— co � o � WQ _z U U U WJDoo- Li < LL U r ce) I c W < I N ry ,47 Q `S 0 U O (.0_ 00 d UPRIGHT (2) #10x2" S411S THRU I12 INTO i EAVE RAIL EACH SIDE OF COLUMN DETAIL `G" - SLOPED PURLIN CONNECTION SCALE: N.T.S. -Ir2'x I/16"'PLATE (12) #12xi" SMS (TOP OR BOTTOM) @ 1" SPACING Z Y.2" EDGE BEAM (2) #I0x3" SMS INTO SCREW BOSSES CONNECTING EDGE BEAM TO PUP.LIN - I'x2' FASTENED TO COLUMN w/(2) 410x1-112' SMS INTO SCREW BOSSES FOR SMB OR SNAP COLUMN - I"x2' SNAP NOTCH COLUMN AS REO'D. COLUMN PER PLAN ALTERNATE DETAIL "G" SLOPED PURLIN CONNECTION SCALE: N.T.S. x, U <) J D z m z W O0 W J F- LL O W QZU o W O z Q m d a 0 3 O (a Q IL w z O O DESIGN DATE: 09/09/2020 REVISION 1: DATE REVISION 2: DATE PAGE: DRAWN BY: TCP SCALE: NTS - -- -- -- --r - - .. - -- 0 GIRT FASTENED INTERNALLY AT EACH END O #f0,L5' EACH SCREW GROOVE. FASTEN TO BEAM w/ 2x2x.125 ANGLE (2) #12 SMS FOR BEAMS ABOVE INSTAL I GUTTER BRACE AT MID MIDrO NT "' a C E (2) #tCxi.5 T`HRU ANGLE NTO GJ :�. 1 R NO Girc IS PRES�t'. kTTACH BETWEEN BEAMS 6 INC UD 2" ANGLE DIRw,iY TO GUT"EA GUTTER BRACE AT oACN BCA� " LOCATION V - _ 050" GUTTER STIFENER � FASTEN TO FASIA::(2) :. ILx2 WOOD SCREW FASTEN TO GUTTER •.,•(2) GUTTER L9 2"x2 a 8' ANGLE v.i(2) I2 SMS #i2 SMS EACH LEG WHEN BEAM 8 PURLIN�- --h!T Oh CORNER - - FAST t OUTSIDE OF FOR GUTTEP, TO FASCIA: #12 SMS (1) #IA @ 18` 0 C — wN I18a2 x2"LANGLE00- o FOR GU -TER BRACE,' STRAP: 8 (») #I2 SMS EACH LEG '0 "u O t` o I (2) #IA EA. STRAP. # CLOSE BOTTOM OF ° ° GUTTER BEAM WHEN TRIMMED SEE TOP VIEW F- M F -OLL RECEIVING CHAIN NEL•- CLLI .i FASTEN wX2) #IZ SMS o 0 ry FOR BEAM OVER Zx5 Q EACH SIDE OF BEAM NTE R ALLY G CHANNEL FASTEN TO STRUCTURAL GUTTER � _ INTERNALLY w!(2) #I2 SMS C) ALTERNATELY 2x2xf/8" At9GLE BELOW G1P.T. (2) #IL 5.95 INTO FASTEN INSIDE CORNER BEAR 8 (2) #12 SMS INTO STRUCTURAL GUTTER (SEAM TO PURLIN) wt i18"x2"s2" ANGLE 0 co w,(2) #12 SMS - - J m SIDE VIEW INTO EA. MEMBER W Q LL Lo •y_ -va(BEAM 8 PURLIN) L.L GIRT uj co #IC SMS WITHIN 6" (9) #10x2" S?^,S t— 0) FASTEN of BEAM a 2L° Q.c GUTTERTODETAIL "M" BEAM & PURLIN TO GUTTER z G Q FAsaA . #ILx2" CONNECTION SCALE: N.T.S. !r8" PLATE ON L504NGLE W Q _j WOOD SCREW I8" O.C. -- OR !18"x2"xz" aivGLE II/(A) cr 4-7 412 SMS INTO EACH o o o o „{ +� (2) #12 SMS INTERSECTtNG MEMBER o < Z o - — q EYEBOLT FOR F� ti (2) #ILx2" (2) -;L.WOOD SCREWS o CABLE TENSION 2x2zV8" ANG! E co MOOD SCREW INTO FASCIANt EA. SIDE OF BEat-S PERIMETER (2) ni2 SMS � �_ ^ w/(2) #I2 SMS FRAMING 1 1/8" ST"AIMLESS STEEL l.L.. EACH LEG EACH SIDE ! BEADED CABLE FASCIA {2"xb" FtIN. EXISTING) b2x1i8" ANGLE ea(2) GIRT ( ( i� #12 SMS EA, LEG STRUCTURAL GUTTER ° ° O o o DETAIL "I-2" CABLE CONNECTION z TOP VIEW SMB ° _ AT CORNER SCALE: N.T.S. DETAIL "H" BEAM TO GUTTER W CONNECTION SCALE: N.T.S. ° ° GIRT o ° i, � O lf8" STAINLESS STEEL 3000 PSI CONC. CL 118"x2"xL" STRAP STRUCTURAL GUTTER BRAIDED CABLE 6x6-IOxIO rF (2) #12 SMS (NTO BEAM SIDE VIEW - LOO MIN. WWM OR FIBERMESH _ 60= MAX (2) #12 SMS INTO GUTTER o o o1 o o f o I o o F °I o ol \\ o `F GIRT ' (2) GUTTER BRACES L 0 EACH wl(2) #12 SMS FASCIA \\o o r INTO GUTTER 8 t2) #IL X 2" L" MIN- SLAE U \\ o 0 0 ""'5052-H32 GUSSET WOOD SCREWS INTO FASCIA w/FOOTING 318" DIA x 3" EMBED \ F INTERNAL OR EXTERNAL CONC.SCREW ANCHOR \\° 8" INTO EA. SIDE TYP. 2x2MI8" ANGLE •./(2) ° (TAPCON OR EOU40 J U) (2XIOSMB ILLUSTRATED) #12 SMS EA. LEG —) m NOTE F INSTALL FASTENERS ALONG PERIMETER OF GUSSET -BEAM JOINT 3/8' MIN, FROM EDGE FASTENERS MAY BE STAGGERED TO INSURE PROPER QUANTITY PER TABLE B-I FASTENER PATTERN MAY APPEAR DIFFERENT FROM ILLUSTRATION. MAfNTAN 1/2" SEPARATION BETWEEN FASTENERS. MAINTAIN 3/8' MIN, FASTENER SEPARATION FROM BEAM JOINT OR EDGE OF BEAM LAP FASTENERS MAY BE EVENLY SPACED AROUND EDGE OF GUSSET WITHIN 5/8' OF BEAM JOINT. FASTENERS MAY BE STAGGERED TO INSURE PROPER OUANTITY PER TABLE B-1 TABLE B-I aEAM SIZE CCL TO BEAM Q' Y SMS/ SIDE OF COL 'BEAM TO 'BEAM CITY SMSI FACE/SIDE 2 x 4 (5) #12 (9) #12 2 x 5 (5) #12 (9) #12 2 x 6 (7) #12 (9) #12 2 x 7 (10) #12 (10) #12 2 x 8 (12) #12 (14) #12 2 x 9 (14) #14 (14) #14 2 x 10 (16) #14 (15) #14 3000 PSI CONIC bx6-IOx'o Z W100 Z O 4G0 MIN. 60E MAX. WWM OR FIBERMESH W J /� F- LL SMB V (n Q . e e , 0 s` Q U 8'x2"xA' STRAP . as W O Z1 m (2) #12 SMS INTO BEAM GIRT STRUCTURA! GUT, d 0 G J (2) 912 SMS INTO GUTTER Q O »" MIN. SLAB Z W .r a - TOP VIEW w/FOOTING 5"x5.5" ALUM. STRAP O w1(2) i1W DIA. x 2-1!:." O af MASONRY ANCHOR C.) CL DETAIL "L" CORNER GUTTER (TAPCON OR EQUAL) DESIGN DATE: 09/09/2020 CONNECTION SCALE: N.T.S. DETAIL "I -I" CABLE CONNECTION REVISION 1: DATE DETAIL "K" GUSSET CONNECTION AT FOUNDATION SCALE: N.T.S. REVISION 2: DATE PAGE: SCALE: N.T.S. DRAWN BY: TCP SCALE: NTS 3/16" 5052-H32 GUSSET #14 SMS @ 1 1/4" O.C. 2" X PURLINS ATTACH TO BEAM WITH MIN (4) #10 X 1 1/2" SMS PLACE WASHER UNDER SCREW IN GUSSET CORNER / o 0 0 0 0 0 0 0 1 114" (TYPICAL) 00 51a" 2"X2"X1/8" ANGLE X 4" LONG PROVIDE #14 X 1" INTO EACH MEMBER AS INDICATED BELOW PROVIDE INTERIOR ANGLE ABOVE AND BELOW CHAIRRAIL 2318 5"' a NOTES: 1. 1. GUSSET DIMENSION ARE MINIMUM (2) REQ'D (1) EA SIDE OF BEAM - MAYBE INTERNAL OR EXTERNAL 2. AS BEAM SIZE CHANGES, ADD OR SUBTRACT SCREWS TO MAINTAIN 1-1/4" C/C SPACING 3. GUSSET LENGTHS REMAIN CONSTANT WIDTHS CHANGE TO MATCH BEAM SIZE. EXTERIOR PLATE CORNER POST /- EAVE RAIL 1" x 2" O.B. PATIO SECTION 3" x 3" x 0.050" MIN., 6063-T6 ALLOY PLATE DR STRONGER (ONE SIDE) WITH (3) - #12 x 3/4" S.M.S. EACH SIDE AS SHOWN (318" MIN. PLATE EDGE DISTANCE & C-C FASTENER SPACING) x2x0.0 DACE (TYP.) K-BRACE LATERAL "K"-BRACING CONNECTION DETAILS 1" X 2" O.B. FASTENED TO CORNER POST W/ #12 X 1 1/2" SMS AT 6" FROM 'ANGLE TOP & BOTTOM RAILS TYPICALLY @ 24" O.C. 1" INTO EACH 1/8" X 2" X 2" EXTRUDE ANGLE 5052 DICATED BELOW CONCRETE SCREW ANCNCHOROR INTO H-32 ALLOY EA CORNER W/ (2) #14 X 2" CORNER POST- SMS INTO POST & (1) CONCRETE 1� 6" I'll I — (2) #10 X 1 1/2" SMS THRU SCREW BOSSES 2 7/4M " 4 CONC �ANCHOR Ejpv�1tBEDMENT ;:-1. SLAB/FOOTING NOTES: SEE PLAN 1. CONNECTION DETAIL AT EAVE RAIL SIMILAR SIDE VIEW GUSSET PLATE PER &SERIES SELF MATING BEAM PURLIN DETAIL #2 3" x 2" x 0.050" MIN., 6063-T6 ALLOY PLATE DR STRONGER (ONE SIDE) CONTRACTOR TO INSTALL (2) #14 X 2" SMS THRU BRACE INTO BEAM THRU GUSSET PLATE CORNER POST CORNER K-BRACE DETAIL SCALE: N.T.S. (4) #14 X 3/4" SMS INTO POST 1" X 2" BASE PLATE ANCHORED TO CONC W/ 1/4" CONCRETE SCREW ANCHOR (MIN. 1 1/4" EMBED) 6" MAX EACH SIDE OF POST AND 24" O.C. MAX Fill �iM3U�1 2" -{ CORNER POST W/ 1" X 2" @ h - BACKSIDE 3/8" X LENGTH AS REQUIRED FOR 2 1/4" EMBED CONCRETE SCREW ANCHOR INTO CONCRETE CP-1 CORNER POST TO CONCRETE DETAIL A-4 SCALE: NTS o " di cm 11,co 00 Q ,O fl- M J- M co 17- M Z�< 0 Q C) W' o u,j-jOoo0) I U7 W <C LL Lc> .— z_CK L m (ri ~ I� Cr) W Q i rn a) 4— Q =�� o<U !� F- ti O °O u- o r'li 6" x 5" x 0.050" COLUMN Ly- (3) - #12 x 3/4" S.M.S., U EACH SIDE AS SHOWN 60DE) ALLOY PLATE (1/2" MIN. PLATE EDGE K-BRACE (ONE SIDE) OR STRONGER 2 x 2 x 0.093 (� _ DISTANCE & C-C BRACE (TYP.) D FASTENER SPACING) K-BRACE Z III Z x2x0.093 W O BRACE (TYP. W 2 x 3 x 0.070 CHAIR RAIL u- p1 p ®--p CO i- 1 -1 p w > f- p l p p p 1 p GIRT (CHAIR RAIL) W <( Z U 1 W o K-BRACE m 75 --- - ----a ® Z 4 p p p, J I Q NT U 0 < h d J Q. z O 2 x 2 x 0.093 318" 0 CONCRETE ANCHOR (2 PLATES) d FOUNDATION IN LIEU OF TYP. 1/4" 0 CONCRETE BRACE (TYP.) . A TOTAL) - 2 x 3/4" SCREWS FOR CORNER COLUMN S.M.S. E (1 SHOWN (1/2" MIN. DESIGN DATE: 09/09/2020 PLATE EDGE DISTANCE & REVISION 1: DATE LATERAL "K"-BRACING C-C FASTENER SPACING) LATERAL "K"-BRACING REVISION 2: DATE PAGE : CONNECTION DETAILS CONNECTION DETAILS DRAWN BY: TCP SCALE: NTS (3) 1/4" DIA. MACHINE BOLTS wl 3/4" DIA. WASHERS THRU CARRIER BEAM & POST Up CARRIER BEAM VARIES / POST NOTE: FOR DOUBLE OR TRIPLE CARRIER BEAM, OUTSIDE WEBS SHALL OVERLAP 4x4 POST OR NOTCH POST AS ABOVE FOR 6x6 POST. ALL CASES, CONNECT USING MACHINE BOLTS DECRIBED ABOVE. 2" x7' FASTENED TO CARRIER IL BEAM w/(2) # 10xl-1 /7' SMS INTO SCREW BOSSES EACH END 4 L I 1"x7' MEMBER (2) 2"x_ SMB FOR SCREENING (SEE PAGE 2 FOR SIZE) HORIZONTAL BEAM # 14x1 SMS 17' O.C. ON ITS SIDE STAGERED ROWS (IF REQUIRED) — 2"xZ'x0.125" i 2" FOR SINGLE RECEIVING CHANNEL HORIZONTAL BEAM OR ANGLE EACH SIDE 4" FOR DOUBLE HORIZONTAL (6) # 1Ox0.75" SMS BEAM OR 4'h4" EACH SIDE 6' FOR TRIPLE HORIZONTAL BEAM OR 6X6 112) # 1 OxO.7S' SMS 2 ROWS OF (6) FOR RECEIVING CHANNEL OR (6) EACH ANGLE CARRIER BEAM TO POST DETAIL SCALE: NTS CARRIER. BEAM 1"x7' MEMBER 0 FOR SCREENING-� ° 0 # 1 Oxl -1 /2' SMS 9- 24" O.C. MAX CONNECTING TO Yx2"CARRIER BEAM # IOxI -l /T SMS a 24" O.C. MAX CONNECTING - TO 1"x2" POST 2"x2'x0.125' ANGLE EACH SIDE TYP. ROOF BEAM (SLOPED OR FLAT) (NOTE USE SIMILAR DETAIL FOR NOTCHED UPRIGHT CONNECTION TO CARRIER BEAM .�- 3/4" SMS SEE TABLE FOR QUANTITY (TYP. EACH SIDE) 3/4- SMS SEE TABLE FOR QUANTITY (TYP. EACH SIDE) NOTE: FOR DOUBLE OR TRIBLE CARRIER BEAM, OUTSIDE WEBS SHALL OVERLAP 4x4 POST OR NOTCH POST AS ABOVE FOR 6x6 POST. ALL CASES, CONNECT USING MACHINE BOLTS DECRIBED ABOVE. ROOF BEAM TO CARRIER BEAM CONNECTION DETAIL SCALE: NTS ROOF BEAM TO C.B. W/ 1 /8" ANGLE TABLE BEAM SIZE QUANTITY/ SIZE EA. LEG TO BEAM 2 x 4 (4) # 12 OR (2) # 16 2 x 5 (5) # 12 OR (3) # 16 2 x 6 (5) # 12 OR (3) # 16 2 x 7 (6) # 14 OR (4) # 16 2x8 (7) #14OR(4) # 16 2 x 9 (8) # 14 OR (5) # 16 2 x 10 (9) # 14 OR (6) # 16 N 'O (3) 1/4" DIA. MACHINE BOLTS— �" a w/ 3/4" DIA. WASHERS THRU POST' U` CARRIER BEAM & POST - (3) 1/4" DIA. MACHINE BOLTS w/ 3/4" DIA. WASHERS THRU CARRIER BEAM & POST TOP VIEW CARRIER BEAM O CARRIER BEAM 0 t / CARRIER (BEAM & POST A. MACHINE BO wl 3/4" DIA. WASHERS US 0 I f (3) 1/4" DIA. MACHINE BOLTS POST wl 3/4" DIA. WASHERS THRU CARRIER BEAM & POST FRONT VIEW CORNER CARRIER BEAM CONNECTION DETAIL SCALE: NTS (4) 3/97c4" TAPCON THRU BOTTOM LEG OF ANGLE INTO CONC. 1" (6) 3/8"x5" TAPCON THRU BOTTOM LEG (6) 3/8" xS' TAPCON (3) 1/4" DIA. MACHINE -,-}- OF ANGLE INTO CONC. _ _[ 1 THRU BOTTOM LEG BOLTS w/ WASHERS 1 2. OF ANGLE INTO CONC. I i (4) 1/4" DIA. MACHINE 4" (4) 1/4" DIA. MACHINE (D I j 3-3/4" FROM EDG 1., BOLTS w/ WASHERS BOLTS w/ WASHERS I i OF SLAB/ FTG. 3-3/4" FROM EDG i" 3-3/4" FROM EDGE TOP VIEW OF SLAB/ OF SLAB/ FTG. OF SL AB/ FTG. FROM EDG OF SLAB (TYP.) --t COLUMN PER PLAN TOP VIEW TOP VIEW (3) 1/4" DIA. MACHINE 6X6 POST 6X6 POST PER PLAN / PER PLAN BOLTS w/ WASHERS (4) 1/4" DIA. MACHINE (4) 1/4" DIA. MACHINE 1/9xn2'x3-3/4" BOLTS w/ WASHERS BOLTS w/ WASHERS (LENGTH) ANGLE 1/8"xn7'x5-3/4" (4) 3/8"x4" TAPCON (INTERNAL) i (LENGTH) ANGLE THRU BOTTOM LEG (6J 3/8"x5" TAPCON i (INTERNAL) (3) 1 /2' DIA. EXPANSION I I 7'x6'x0.125 ANGLE OF ANGLE INTO CONC. �� c THRU BOTTOM LEG I I BOLTS SEE NOTE #2 j OF ANGLE INTO CONC. I THIS PAGE FOR BOLT i I I PLACEMENT 3000 PSI CONC. • ° f� • , 3000 PSI CONC. SLAB/FTG. ° SLAB/FTG. 6x6-1Ox10 WWM 6x6-1Ox10 WWM OR FIBERMESH FRONT VIEW OR FIBERMESH 4X4 COLUMN ALT. BASE ATTACHMENT DETAIL SCALE: NTS NOTES: 1. 3x3 POST TO HAVE 3/8" RED HEAD - TRUBOLT WEDGE ANCHORS (STAINLESS STEEL, PROVIDE MINIMUM 2" FROM EDGE OF SLAB AND PROVIDE MINIMUM 2" SPACING TO ANY OTHER CONNECTOR. SEE MFG. NOTES FOR INSTALLATION REQUIREMENTS. THREADED ROD REQUIRES 3" MINIMUM EDGE DISTANCE. 2. 4x4 POST TO HAVE 1 /2" RED HEAD - TRUBOLT WEDGE ANCHORS (STAINLESS STEEL, PROVIDE MINIMUM 3-3/4" FROM EDGE OF SLAB AND PROVIDE MINIMUM 3-3/4" SPACING TO ANY OTHER CONNECTOR. SEE MFG. NOTES FOR INSTALLATION REQUIREMENTS. FRONT VIEW 6"x6' POST CONNECTION DETAIL (INTERNAL BASE) SCALE: N.T.S. 3000 PSI CONC. SLAB/ FTG. ° 6x6-1Ox10 WWM OR FIBERMESH FRONT VIEW 6"x6" POST CONNECTION DETAIL SCALE: N.T.S. 3. WHERE PAVERS ARE PRESENT ANCHOR LENGTH SHALL BE INCREASED BY THICKNESS OF PAVER NOT TO EXCEED 2-1/7' FOR PAVER THICKNESS MORE THAN 2-1/7' SPECIFICATIONS SHALL BE REQUIRED. PAVERS SHALL BE BONDED TO UNDERLYING CONCRETE FOUNDATION.