HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: MICHAEL FOSTER
Builder Name:
Street: 176 ESTEIA LANE
Permit Office:
City, State, Zip: PORT ST. LUCIE , FL,
Permit Number:
Owner:
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing Existing (Projecte
9. Wall Types (1224.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1224.00 ft2
b. N/A
R= ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (1162.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1162.00 ft2
6. Conditioned floor area above grade (ft2) 1162
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0 4
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(252.0 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: A/C
6 145
a. U-Factor: Dbl, U=0.65 252.00 ft2
SHGC: SHGC=0.25
b. U-Factor: N/A ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
_ 24.6 SEER:16.00
c. 'U-'Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
27.0 COPA.00
SHGC:
Area Weighted Average Overhang Depth: 6.114 ft.
Area Weighted Average SHGC: 0.250
14. Hot water systems
8. Floor Types (1162.0 sqft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1162.00 ft2
b. Conservation features
EF: 0.950
b. N/A R= ft2
None
c. N/A R= " ft2
15. Credits
CF, Pstat
Glass/Floor Area: 0.217 Total Proposed Modified Loads: 48.25
PASS
Total Baseline Loads: 48.60
I hereby certify that the plans and specifications covered by
Review of the plans and
Sy q?�
this calculation are in compliance with the Florida Energy
specifications covered by this
O�ZSE
Code.
calculation indicates compliance
with the Florida Energy Code.
ti �r,,,,, , ., .,;;_ ,, ,
'' ,,j. •` „ O
PREPAR D BY:
Before construction is completed
c �
DATE: - I -
this building will be inspected for
O ^ ` y
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
! ��
with the Florida Energy Code.
G'OD WME
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
RECeiveo
DEC 9101�
at
e a
12/12/2018 8:16 AM EnergyGauge® USA Section R405.4.1 Compliant Softw to uq ent Payl of 5
FORM R405-2017 INPLJ� ..SUMMARY CHECKLIST REPORT'
PROJECT
Title: MICHAEL FOSTER
Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 1162
Lot #
Owner Name:
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
176 ESTEIA LANE
Permit Office:
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State, Zip:
PORT ST. LUCIE
,
Family Type: Single-family
FL,
New/Existing: Existing (Projected)
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location
TMY Site 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39
90
70
75 299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1162 10458
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
InflID Finished Cooled
Heated
1 BATH
76 684 No
0
-
1 Yes
Yes
Yes
2 BEDROOM 2
220 1980 No
0
1
1 Yes
Yes
Yes
3 BEDROOM 1
180 1620 No
0
1
1 Yes
Yes
Yes
4 BED 3
108 972 No
0
1
1 Yes
Yes
Yes
5 KITCHEN
121 1089 Yes
0
1 Yes
Yes
Yes
6 LIVING AREA
240 2160 No
0
1 Yes
Yes
Yes
7 LIVING
211 1899 No
0
1 Yes
Yes
Yes
8 A/C
6 54 No
0
1 No
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
BATH 15 ft 0
76 ft2.
____
0 1
0
2 Slab -On -Grade Edge Insulatio
BEDROOM 2 32 ft 0
220 ft2
----
0 1
0
3 Slab -On -Grade Edge Insulatio
BEDROOM 1 27 ft 0
180 ft2
_-__
0 1
0
4 Slab -On -Grade Edge Insulatio
BED 3 9 ft 0
108 ft2
____
0 1
0
5 Slab -On -Grade Edge Insulatio
KITCHEN 22 ft 0
121 ft2
____
0 1
0
6 Slab -On -Grade Edge Insulatio
LIVING AREA 34 ft 0
240 ft2
____
0 1
0
7 Slab -On -Grade Edge Insulatio
'LIVING 13 ft 0
211 ft2
-___
0 1
0
8 Slab -On -Grade Edge Insulatio
A/C 1 ft 0
6 ft2
--__
0 1
0
12/12/2018 8:16 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 2 of 5
,y
FORM R405-2017 INPU'l]'.. wUMMARY CHECKLIST REPORT
ROOF
v
! Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
#
Type Materials Area
Area
Color
Absor.
Tested
Tested
Insul.
(deg)
1
Hip Composition shingles 1225 ft2
0 ft2
Medium
0.6
No
0.9
No
0
18.4
ATTIC
V
#
Type Ventilation
Vent Ratio (1
in) Area
RBS
IRCC
1
Full attic Vented
150
1162 ft2
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Vented) BATH
30
Blown
76 ft2
0.1
Wood
2
Under Attic (Vented) BEDROOM 2
30
Blown
220 ft2
0.1
Wood
3
Under Attic (Vented) BEDROOM 1
30
Blown
180 ft2
0.1
Wood
4
Under Attic (Vented) BED 3
30
Blown
108 ft2
0.1
Wood
5
Under Attic (Vented) KITCHEN
30
Blown
121 ft2
0.1
Wood
6
Under Attic (Vented) LIVING AREA
30
Blown
240 ft2
0.1
Wood
7
Under Attic (Vented) LIVING
30
Blown
211 ft2
0.1
Wood
8
Under Attic (Vented) A/C
30
Blown
6 ft2
0.1
Wood
WALLS
Adjacent Space
Cavity Width Height
le Et In, Et In
Area
Sheathing Framing
R-1/able EraCtoon
Solar
AhSor
Below
Grade%
1
SW
Exterior Concrete Block - Ext Insul BATH
4.1 8
0 9
0
72.0 ft2
0
0
0.6
0
_ 2
NW
Exterior Concrete Block - Ext Insul BATH
4.1 7
0 8
0
56.0 ft2
0
0
0.6
0
3
SE
Exterior Concrete Block - Ext InfiffDROOM 2,,
4.1 16
0 8
0
128.0 ft2
0
0
0.6
0
_ 4
SW
Exterior Concrete Block - Ext InEEDROOM 2 ,
4.1 16
0 8
0
128.0 ft2
0
0
0.6
0
_ 5
NE
Exterior Concrete Block - Ext InREDROOM 1
4.1 15
0 8
0
120.0 ft2
0
0
0.6
0
_ 6
SE
Exterior Concrete Block - Ext IndIEDROOM 1
4.1 12
0 8
0
96.0 ft2
0
0
0.6
0
7
NE
Exterior Concrete Block - Ext Insul BED 3
4.1 9
0 8
0
72.0 ft2
0
0
0.6
0
8
SW
Exterior Concrete Block - Ext InsuKITCHEN
4.1 11
0 8
0
88.0 ft2
0
0
0.6
0
9
NW
Exterior Concrete Block - Ext InsuKITCHEN
4.1 11
0 8
0
88.0 ft2
0
0
0.6
0
10
NE
Exterior Concrete Block - Ext InsLAVING ARE
4.1 24
0 8
0
192.0 ft2
0
0
0.6
0
11
NW
Exterior Concrete Block - Ext InsUVING ARE
. 4.1 10
0 8
0
80.0 ft2
0
0
0.6
0
12
SW
Exterior Concrete Block - Ext Insul LIVING
4.1 13
0 8
0
104.0 ft2
0
0
0.6
0
DOORS
#
Ornt Door Type Space
Storms
U-Value Width
Height
Area
Ft
In
Ft In
1
NW Insulated LIVING ARE
None
.39
3
7
21 ft2
2
SW Insulated LIVING
None
.39
3
7
21 ft2
12/12/2018 8:16 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2017 INPU,_ •SUMMARY CHECKLIST REPORT'
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V #
Ornt ID Frame
Panes NFRC
U-Factor SHGC Imp
Area
Depth
Separation
Int Shade
Screening
1
SW 1 Metal
Low-E Double Yes
0.65 0.25 N
9.0 ft2
2 ft 0 in
1 ft 4 in
None
None
2
SE 3 Metal
Low-E Double Yes
0.65 0.25 N
11.7 ft2
2 ft 0 in
1 ft 4 in
None
None
3
(SW 4 Metal
Low-E Double Yes
0.65 0.25 N
11.3 ft2
2 ft 0 in
1 ft 4 in
None
None
4
SW 4 Metal
Low-E Double Yes
0.65 0.25 N
23.3 ft2
2 ft 0 in
1 ft 4 in
None
None
5
NE 5 Metal
Low-E Double Yes
0.65 0.25 N
11.7 ft2
2 ft 0 in
1 ft 4 in
None
None
6
NE 5 Metal
Low-E Double Yes
0.65 0.25 N
12.0 ft2
2 ft 0 in
1 ft 4 in
None
None
7
SE 6 Metal
Low-E Double Yes
0.65 0.25 N
11.7 ft2
2 ft 0 in
1 ft 4 in
None
None
8
NE 7 Metal
Low-E Double Yes
0.65 0.25 N
12.0 ft2
2 ft 0 in
1 ft 4 in
None
None
9
NE 7 Metal
Low-E Double Yes
0.65 0.25 N
12.3 ft2
2 ft 0 in
1 ft 4 in
None
None
10
SW 8 Metal
Low-E Double Yes
0.65 0.25 N
9.0 ft2
2 ft 0 in
1 ft 4 in
None
None
11
NE 10 Metal
Low-E Double Yes
0.65 0.25 N
11.7 ft2
12 ft 0 in
1 ft 4 in
None
None
12
NE 10 Metal
Low-E Double Yes
0.65 0.25 N
12.0 ft2
12 ft 0 in
1 ft 4 in
None
None
13
NE 10 Metal
Low-E Double Yes
0.65 0.25 N
80.0 ft2
12 ft 0 in
1 ft 4 in
None
None
14
SW 12 Metal
Low-E Double Yes
0.65 0.25 N
12.0 ft2
2 ft 0 in
1 ft 4 in
None
None
15
SW 12 Metal
Low-E Double Yes
0.65 0.25 N
12.3 ft2`
2 ft 0 in
1 ft 4 in
None
None
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .0004
1220.1 66.98 125.97
.3005
7
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/ None
COP:1
27 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency
Capacity Air Flow SHR Block
Ducts
1
Central Unit/
Split
SEER: 16 24.6 kBtu/hr
cfm
0.8 1
sys#1
HOT WATER SYSTEM
#
System Type
SubTpe Location
EF Cap
Use
SetPnt
Conservation
1
Electric
None Attic
0.95 40 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector
Model #
Area
Volume
FEF
None None
ft2
12/12/2018 8:16 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 5
FORM lR405-2017 INP6, -SUMMARY CHECKLIST REPORT', -1
DUCTS
--- Supply ----
V
---- Return ----
Air
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT QN
RLF
Heat Cool
1 Attic
6 145 ft2
Attic
45 ft2
_ Default Leakage
A/C
(Default)
(Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJan Feb
HeatinHJan H Feb
Mar
H Mar
E
Apr
i AprfiMayf
Ma
X Jun
lJun
X Jul
4 Jul
Au
rj Au
SeP
jXj Se
Oct
� Oct
H
Nov
Nov
Dec
HDec
Ventin Jan Feb
X Mar
[X
A r
[
Ma
[ Jun
[ Jul
Aug
Se
Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD) AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH) AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD) AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH) AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
Oft
0.3
BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 1
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BED 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LIVING AREA
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LIVING
Default(8 Ibs/s .ft.
ft2
ft
0.3
A/C
Name:
Rating Compant:
Signature:-CtmRae�;-,et�
D.
12/12/2018 8:16 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 5
2017 - AIR BARRIER AND INSULL- rJON INSPECTION COMPONENT CR'r..-.:RIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: MICHAEL FOSTER Builder Name:
Street: 176 ESTEIA LANE Permit Office:
City, State, Zip: PORT ST. LUCIE , FL, Permit Number:
Y
U
Owner: Jurisdiction:
W
Design Location: FL, Fort Pierce
U
f
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed. l
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed. ,
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
Ds.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring,
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, -concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinkler cover plates and walls or ceilings.
a. in addition, inspection or log watts shall ne in accordance with the provisions of ICC-400.
12/12/2018 8:16 AM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1
2417 EPL DISPLAY CARD ,
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* =. 99
The lower the Energy Performance .Index, the more efficient the home.
1. New home or, addition
1. Existing (Projected)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location Attic/Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
3
13. Cooling system: Capacity
24.6
a) Split system SEER
16.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1162
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.650
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.250
14. Heating system: Capacity
27.0
c) Area
7c.
252.0
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.95
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
f). Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
2. Masonry (Insulation R-value)
10B2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
Yes
a) Under attic
11 a.
30.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11 c.
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
"Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature:,
Date:
Address of New Home: 176 ESTEIA LANE City/FL Zip: PORT ST. LUCIE, FL
12/12/2018 8:16:41 AM EnergyGaugeO USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1