Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: MICHAEL FOSTER Builder Name: Street: 176 ESTEIA LANE Permit Office: City, State, Zip: PORT ST. LUCIE , FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing Existing (Projecte 9. Wall Types (1224.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1224.00 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (1162.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1162.00 ft2 6. Conditioned floor area above grade (ft2) 1162 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 4 c. N/A R= ft2 11. Ducts R ft2 7. Windows(252.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: A/C 6 145 a. U-Factor: Dbl, U=0.65 252.00 ft2 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit _ 24.6 SEER:16.00 c. 'U-'Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 27.0 COPA.00 SHGC: Area Weighted Average Overhang Depth: 6.114 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems 8. Floor Types (1162.0 sqft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1162.00 ft2 b. Conservation features EF: 0.950 b. N/A R= ft2 None c. N/A R= " ft2 15. Credits CF, Pstat Glass/Floor Area: 0.217 Total Proposed Modified Loads: 48.25 PASS Total Baseline Loads: 48.60 I hereby certify that the plans and specifications covered by Review of the plans and Sy q?� this calculation are in compliance with the Florida Energy specifications covered by this O�ZSE Code. calculation indicates compliance with the Florida Energy Code. ti �r,,,,, , ., .,;;_ ,, , '' ,,j. •` „ O PREPAR D BY: Before construction is completed c � DATE: - I - this building will be inspected for O ^ ` y compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. ! �� with the Florida Energy Code. G'OD WME OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). RECeiveo DEC 9101� at e a 12/12/2018 8:16 AM EnergyGauge® USA Section R405.4.1 Compliant Softw to uq ent Payl of 5 FORM R405-2017 INPLJ� ..SUMMARY CHECKLIST REPORT' PROJECT Title: MICHAEL FOSTER Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1162 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 176 ESTEIA LANE Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: PORT ST. LUCIE , Family Type: Single-family FL, New/Existing: Existing (Projected) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1162 10458 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InflID Finished Cooled Heated 1 BATH 76 684 No 0 - 1 Yes Yes Yes 2 BEDROOM 2 220 1980 No 0 1 1 Yes Yes Yes 3 BEDROOM 1 180 1620 No 0 1 1 Yes Yes Yes 4 BED 3 108 972 No 0 1 1 Yes Yes Yes 5 KITCHEN 121 1089 Yes 0 1 Yes Yes Yes 6 LIVING AREA 240 2160 No 0 1 Yes Yes Yes 7 LIVING 211 1899 No 0 1 Yes Yes Yes 8 A/C 6 54 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BATH 15 ft 0 76 ft2. ____ 0 1 0 2 Slab -On -Grade Edge Insulatio BEDROOM 2 32 ft 0 220 ft2 ---- 0 1 0 3 Slab -On -Grade Edge Insulatio BEDROOM 1 27 ft 0 180 ft2 _-__ 0 1 0 4 Slab -On -Grade Edge Insulatio BED 3 9 ft 0 108 ft2 ____ 0 1 0 5 Slab -On -Grade Edge Insulatio KITCHEN 22 ft 0 121 ft2 ____ 0 1 0 6 Slab -On -Grade Edge Insulatio LIVING AREA 34 ft 0 240 ft2 ____ 0 1 0 7 Slab -On -Grade Edge Insulatio 'LIVING 13 ft 0 211 ft2 -___ 0 1 0 8 Slab -On -Grade Edge Insulatio A/C 1 ft 0 6 ft2 --__ 0 1 0 12/12/2018 8:16 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 2 of 5 ,y FORM R405-2017 INPU'l]'.. wUMMARY CHECKLIST REPORT ROOF v ! Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1225 ft2 0 ft2 Medium 0.6 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1162 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BATH 30 Blown 76 ft2 0.1 Wood 2 Under Attic (Vented) BEDROOM 2 30 Blown 220 ft2 0.1 Wood 3 Under Attic (Vented) BEDROOM 1 30 Blown 180 ft2 0.1 Wood 4 Under Attic (Vented) BED 3 30 Blown 108 ft2 0.1 Wood 5 Under Attic (Vented) KITCHEN 30 Blown 121 ft2 0.1 Wood 6 Under Attic (Vented) LIVING AREA 30 Blown 240 ft2 0.1 Wood 7 Under Attic (Vented) LIVING 30 Blown 211 ft2 0.1 Wood 8 Under Attic (Vented) A/C 30 Blown 6 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height le Et In, Et In Area Sheathing Framing R-1/able EraCtoon Solar AhSor Below Grade% 1 SW Exterior Concrete Block - Ext Insul BATH 4.1 8 0 9 0 72.0 ft2 0 0 0.6 0 _ 2 NW Exterior Concrete Block - Ext Insul BATH 4.1 7 0 8 0 56.0 ft2 0 0 0.6 0 3 SE Exterior Concrete Block - Ext InfiffDROOM 2,, 4.1 16 0 8 0 128.0 ft2 0 0 0.6 0 _ 4 SW Exterior Concrete Block - Ext InEEDROOM 2 , 4.1 16 0 8 0 128.0 ft2 0 0 0.6 0 _ 5 NE Exterior Concrete Block - Ext InREDROOM 1 4.1 15 0 8 0 120.0 ft2 0 0 0.6 0 _ 6 SE Exterior Concrete Block - Ext IndIEDROOM 1 4.1 12 0 8 0 96.0 ft2 0 0 0.6 0 7 NE Exterior Concrete Block - Ext Insul BED 3 4.1 9 0 8 0 72.0 ft2 0 0 0.6 0 8 SW Exterior Concrete Block - Ext InsuKITCHEN 4.1 11 0 8 0 88.0 ft2 0 0 0.6 0 9 NW Exterior Concrete Block - Ext InsuKITCHEN 4.1 11 0 8 0 88.0 ft2 0 0 0.6 0 10 NE Exterior Concrete Block - Ext InsLAVING ARE 4.1 24 0 8 0 192.0 ft2 0 0 0.6 0 11 NW Exterior Concrete Block - Ext InsUVING ARE . 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 12 SW Exterior Concrete Block - Ext Insul LIVING 4.1 13 0 8 0 104.0 ft2 0 0 0.6 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 NW Insulated LIVING ARE None .39 3 7 21 ft2 2 SW Insulated LIVING None .39 3 7 21 ft2 12/12/2018 8:16 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 INPU,_ •SUMMARY CHECKLIST REPORT' WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 SW 1 Metal Low-E Double Yes 0.65 0.25 N 9.0 ft2 2 ft 0 in 1 ft 4 in None None 2 SE 3 Metal Low-E Double Yes 0.65 0.25 N 11.7 ft2 2 ft 0 in 1 ft 4 in None None 3 (SW 4 Metal Low-E Double Yes 0.65 0.25 N 11.3 ft2 2 ft 0 in 1 ft 4 in None None 4 SW 4 Metal Low-E Double Yes 0.65 0.25 N 23.3 ft2 2 ft 0 in 1 ft 4 in None None 5 NE 5 Metal Low-E Double Yes 0.65 0.25 N 11.7 ft2 2 ft 0 in 1 ft 4 in None None 6 NE 5 Metal Low-E Double Yes 0.65 0.25 N 12.0 ft2 2 ft 0 in 1 ft 4 in None None 7 SE 6 Metal Low-E Double Yes 0.65 0.25 N 11.7 ft2 2 ft 0 in 1 ft 4 in None None 8 NE 7 Metal Low-E Double Yes 0.65 0.25 N 12.0 ft2 2 ft 0 in 1 ft 4 in None None 9 NE 7 Metal Low-E Double Yes 0.65 0.25 N 12.3 ft2 2 ft 0 in 1 ft 4 in None None 10 SW 8 Metal Low-E Double Yes 0.65 0.25 N 9.0 ft2 2 ft 0 in 1 ft 4 in None None 11 NE 10 Metal Low-E Double Yes 0.65 0.25 N 11.7 ft2 12 ft 0 in 1 ft 4 in None None 12 NE 10 Metal Low-E Double Yes 0.65 0.25 N 12.0 ft2 12 ft 0 in 1 ft 4 in None None 13 NE 10 Metal Low-E Double Yes 0.65 0.25 N 80.0 ft2 12 ft 0 in 1 ft 4 in None None 14 SW 12 Metal Low-E Double Yes 0.65 0.25 N 12.0 ft2 2 ft 0 in 1 ft 4 in None None 15 SW 12 Metal Low-E Double Yes 0.65 0.25 N 12.3 ft2` 2 ft 0 in 1 ft 4 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .0004 1220.1 66.98 125.97 .3005 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 24.6 kBtu/hr cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Attic 0.95 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 12/12/2018 8:16 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 5 FORM lR405-2017 INP6, -SUMMARY CHECKLIST REPORT', -1 DUCTS --- Supply ---- V ---- Return ---- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 145 ft2 Attic 45 ft2 _ Default Leakage A/C (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan Feb HeatinHJan H Feb Mar H Mar E Apr i AprfiMayf Ma X Jun lJun X Jul 4 Jul Au rj Au SeP jXj Se Oct � Oct H Nov Nov Dec HDec Ventin Jan Feb X Mar [X A r [ Ma [ Jun [ Jul Aug Se Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 BED 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 LIVING AREA Default(8 Ibs/sq.ft. ft2 ft 0.3 LIVING Default(8 Ibs/s .ft. ft2 ft 0.3 A/C Name: Rating Compant: Signature:-CtmRae�;-,et� D. 12/12/2018 8:16 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULL- rJON INSPECTION COMPONENT CR'r..-.:RIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: MICHAEL FOSTER Builder Name: Street: 176 ESTEIA LANE Permit Office: City, State, Zip: PORT ST. LUCIE , FL, Permit Number: Y U Owner: Jurisdiction: W Design Location: FL, Fort Pierce U f COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. l per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. , Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac Ds. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring, Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, -concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a. in addition, inspection or log watts shall ne in accordance with the provisions of ICC-400. 12/12/2018 8:16 AM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 2417 EPL DISPLAY CARD , ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* =. 99 The lower the Energy Performance .Index, the more efficient the home. 1. New home or, addition 1. Existing (Projected) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 24.6 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1162 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.650 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 14. Heating system: Capacity 27.0 c) Area 7c. 252.0 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.95 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f). Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans Yes a) Under attic 11 a. 30.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes "Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature:, Date: Address of New Home: 176 ESTEIA LANE City/FL Zip: PORT ST. LUCIE, FL 12/12/2018 8:16:41 AM EnergyGaugeO USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1