Loading...
HomeMy WebLinkAboutEnergy Codeu ; 0, R405-2017 J*A�IORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method rGTVFf') Project Name: PEREZ RESIDEL34950 Builder Name: OWNER/BUILDER Street: 200 BRIDLEWOAYQCT 11 2019 Permit Office: ST LUCIE COUNTY City, State, Zip: FT PIERCE, FL Permit Number:1907-0591 Owner: SANTOS Lucie County,Permitting Jurisdiction: 661000 Design Location: FL, West Palm B County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2822.5 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 2558.10 ft2 b. Concrete Block - Int Insul, Adjacent R=4.1 264.44 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 10. Ceiling Types (3094.0 sgft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 3094.00 ft2 6. Conditioned floor area above grade (ft2) 3094 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(468.3 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Garage 6 240 a. U-Factor: Sgl, U=0.65 468.33 ft2 b. Sup: Attic, Ret: Attic, AH: Garage 6 320 SHGC: SHGC=0.25 b. U-Factor: WA ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 36.0 SEER:16.00 b. Central Unit 42.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d.. U-Factor: N/A ft2 a. Electric Strip Heat 26.2 COPA.00 SHGC: b. Electric Strip Heat 32.8 COP:1.00 Area Weighted Average Overhang Depth: 15.396 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems a. Electric Cap: 65 gallons 8. Floor Types (3094.0 sgft.) Insulation Area EF: 0.880 a. Slab -On -Grade Edge Insulation R=1.0 3094.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.151 Total Proposed Modified Loads: 110.50 PASS Total Baseline Loads: 115.11 I hereby certify that the plans -and specifications covered by Review of the plans and TBE S-r this calculation are in compliance` with the Florida Energy specifications covered by this fy0 = �0�, Code. calculation indicates compliance u,, �''J, �`;=,.',�o� V" 'O Afel with the Florida Energy Code. ti +n�,,'��% = :w:�;;;��'�,� PREPARED BY; DATE: a Before construction is completed this building will be inspected for compliance with Section 553.908 0 I hereby certify that this building, as designedUs n compliance Florida Statutes. COD with the Florida Energy Code. WE OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with 11402.4.11.11 and this prof quires an envelope leakage test report with envelope leakage no greater than 4.50 ACH50 (R402.4.1.2). 10/9/2019 1:02 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5 r RM. R405-2017 INPUT SUMMARY CHFCKI 1ST RFPC)RT PROJECT it le: PEREZ RESIDENCE Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 3094 Lot # Owner Name: SANTOS Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: OWNER / BUILDER Rotate Angle: 0 Street: 200 BRIDLEWOOD WA Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: 661000 Whole House Fan: No City, State, Zip: FT PIERCE, Family Type: Single-family FL, 34950 New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, West Palm Beach FL WEST_PALM_BEAC 44 90 70 75 316 60 Medium BLOCKS Number Name Area Volume 1 Block1 1340 15544 2 Block2 1754 17978.5 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 LIIVING 1340 15544 Yes 2 0 1 Yes Yes Yes 2 BEDROOMS 1754 17978.5 No 8 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio LIIVING 69 ft 1 1340 ft2 ---- 1 0 0 2 Slab -On -Grade Edge Insulatio BEDROOMS 174 ft 1 1754 ft2 ---- 1 0 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 3351 ft2 0 ft2 Light N 0.75 No 0.9 No 2 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 3094 ft2 N Y 10/9/2019 1:02 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 FORNd.R405-2017 INPUT SUMMARY CHECKLIST REPnRT CEILING . # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) LIIVING 30 Blown 1340 ft2 0.11 Wood 2 Under Attic (Vented) BEDROOMS 30 Blown 1754 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below Ornt To Wall Type Able Ft In Et In Area R-Atallie Eractonn Ahqnr r4rarle% _ 1 S Exterior Concrete Block - Int Insul LIIVING 4.0999 30 0 11 4 340.0 ft2 2 0 0.75 0 _ 2 E Exterior Concrete Block - Int Insul LIIVING 4.1 16 4 11 4 185.1 ft2 2 0 0.75 0 3 N Exterior Concrete Block - Int Insul LIIVING 4.1 27 0 11 4 306.0 ft2 2 0 0.75 0 _ 4 N Exterior Concrete Block - Int InsiREDROOMS 4.1 16 6 9 4 154.0 ft2 2 0 0.75 0 5 E Exterior Concrete Block - Int Ins®EDROOMS 4.1 30 4 11 4 343.8 ft2 2 0 0.75 0 6 S Exterior Concrete Block - Int InsfiIEDROOMS 4.1 34 4 9 4 320.4 ft2 2 0 0.75 0 7 N Exterior Concrete Block - Int InsfIEDROOMS 4.1 20 4 11 4 230.4 ft2 2 0 0.75 0 8 W Exterior Concrete Block - Int InsfBEDROOMS 4.1 57.7 9 4 538.5 ft2 2 0 0.75 0 9 W Exterior Concrete Block - Int InsMEDROOMS 4.1 12 4 11 4 139.8 ft2 2 0 0.75 0 10 E Garage Concrete Block - Int Ins®EDROOMS 4.1 23 4 11 4 264.4 ft2 2 0 0.75 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Insulated LIIVING Metal .2 6 8 48 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 1 Metal Single (Tinted) Yes 0.65 0.25 Y 96.0 ft2 14 ft 4 in 3 ft 4 in Drapes/blinds None 2 S 1 Metal Single (Tinted) Yes 0.65 0.25 Y 36.0 ft2 2 ft 0 in 3 ft 4 in Drapes/blinds None 3 E 2 Metal Single (Tinted) Yes 0.65 0.25 Y 64.0 ft2 49 ft 0 in 3 ft 4 in Drapes/blinds None 4 N 3 Metal Single (Tinted) Yes 0.65 0.25 Y 36.0 ft2 12 ft 0 in 1 ft 4 in Drapes/blinds None 5 N 3 Metal Single (Tinted) Yes 0.65 0.25 Y 12.0 ft2 17 ft 0 in 0 ft 6 in Drapes/blinds None 6 S 6 Metal Single (Tinted) Yes 0.65 0.25 Y 96.0 ft2 14 ft 0 in 3 ft 4 in Drapes/blinds None 7 N 7 Metal Single (Tinted) Yes 0.65 0.25 Y 27.0 ft2 2 ft 0'in 3 ft 4 in Drapes/blinds None 8 W 8 Metal Single (Tinted) Yes 0.65 0.25 Y 8.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None 9 W 8 Metal Single (Tinted) Yes 0.65 0.25 Y 45.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None 10 N 3 Metal Single (Tinted) Yes 0.65 0.25 Y 12.0 ft2 12 ft 0 in 1 ft 4 in Drapes/blinds None 11 N 4 Metal Single (Tinted) Yes 0.65 0.25 Y 27.0 ft2 12 ft 0 in 1 ft 4 in Drapes/blinds None 12 S 6 Metal Single (Tinted) Yes 0.65 0.25 Y 9.3 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None 10/9/2019 1:02 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 FORM, R405-2017 INPUT SUMMARY CHECKLIST REPORT GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 588 ft2 588 ft2 72 ft 9.3 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .00031 2513.5 137.99 259.51 .1419 4.4988 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 2 Electric Strip Heat/ Electric Strip Heat/ None None COPA 26.2 kBtu/hr 1 COPA 32.8 kBtu/hr 2 sys#1 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 2 Central Unit/ Central Unit/ Split Split SEER: 16 36 kBtu/hr 1200 cfm 0.75 1 SEER: 16 42 kBtu/hr 1400 cfm 0.75 2 sys#1 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.88 65 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS # --- Supply --- Location R-Value Area -- Return - - Air CFM 25 CFM25 Location Area Leakage Type Handier TOT OUT QN RLF HVAC # Heat Cool 1 2 Attic 6 240 ft2 Attic 6 320 ft2 Attic Attic 66 ft2 Default Leakage Garage (Default) (Default) 90 ft2 Default Leakage Garage (Default) (Default) 1 1 2 2 10/9/2019 1:02 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017)_ Compliant Software Page 4 of 5 0 . .: FORM R405-2017 INPUT-RUMMORY rHFrKI IAT RFPnPT TEMPERATURES ,Programable Thermostat: Y Ceiling Fans: Heating Jan Mar Apr X� Jul X� Aug ] Oct Nov Dec [X� �Feb r Rj �X� AprX� �Jun May �X XSep J �X� [X Jan Feb Mar Jun [X Jul [X Aug [X Sep L�] Oct Nov X� DecVenting Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MECHANICAL VENTILATION Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System Fans/ERV 50 50 80 50 1 - Electric Strip Heat 1 % 1 - Central Unit Fans/ERV 200 200 250 50 2 - Electric Strip Heat 1 % 2 - Central Unit MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 LIIVING Default 8 Ibs/s .ft. 0 ft2 0 ft 0.3 BEDROOMS 10/9/2019 1:02 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5