HomeMy WebLinkAboutEnergy Codeu ;
0, R405-2017
J*A�IORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
rGTVFf')
Project Name: PEREZ RESIDEL34950
Builder Name: OWNER/BUILDER
Street: 200 BRIDLEWOAYQCT 11 2019
Permit Office: ST LUCIE COUNTY
City, State, Zip: FT PIERCE, FL
Permit Number:1907-0591
Owner: SANTOS Lucie County,Permitting
Jurisdiction: 661000
Design Location: FL, West Palm B
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (2822.5 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 2558.10 ft2
b. Concrete Block - Int Insul, Adjacent
R=4.1 264.44 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
10. Ceiling Types (3094.0 sgft.)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=30.0 3094.00 ft2
6. Conditioned floor area above grade (ft2) 3094
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(468.3 sgft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Garage
6 240
a. U-Factor: Sgl, U=0.65 468.33 ft2
b. Sup: Attic, Ret: Attic, AH: Garage
6 320
SHGC: SHGC=0.25
b. U-Factor: WA ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
36.0 SEER:16.00
b. Central Unit
42.0 SEER:16.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d.. U-Factor: N/A ft2
a. Electric Strip Heat
26.2 COPA.00
SHGC:
b. Electric Strip Heat
32.8 COP:1.00
Area Weighted Average Overhang Depth: 15.396 ft.
Area Weighted Average SHGC: 0.250
14. Hot water systems
a. Electric
Cap: 65 gallons
8. Floor Types (3094.0 sgft.) Insulation Area
EF: 0.880
a. Slab -On -Grade Edge Insulation R=1.0 3094.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.151 Total Proposed Modified Loads: 110.50
PASS
Total Baseline Loads: 115.11
I hereby certify that the plans -and specifications covered by
Review of the plans and
TBE S-r
this calculation are in compliance` with the Florida Energy
specifications covered by this
fy0 = �0�,
Code.
calculation indicates compliance
u,, �''J, �`;=,.',�o� V"
'O
Afel
with the Florida Energy Code.
ti +n�,,'��% = :w:�;;;��'�,�
PREPARED BY;
DATE: a
Before construction is completed
this building will be inspected for
compliance with Section 553.908
0
I hereby certify that this building, as designedUs n compliance
Florida Statutes.
COD
with the Florida Energy Code.
WE
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with 11402.4.11.11 and this prof quires an
envelope leakage test report with envelope leakage no greater than 4.50 ACH50 (R402.4.1.2).
10/9/2019 1:02 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5
r
RM. R405-2017
INPUT SUMMARY CHFCKI 1ST RFPC)RT
PROJECT
it le:
PEREZ RESIDENCE
Bedrooms: 4
Address Type: Street Address
Building Type:
User
Conditioned Area: 3094
Lot #
Owner Name:
SANTOS
Total Stories: 1
Block/Subdivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
OWNER / BUILDER
Rotate Angle: 0
Street: 200 BRIDLEWOOD WA
Permit Office:
ST LUCIE COUNTY
Cross Ventilation: No
County: St. Lucie
Jurisdiction:
661000
Whole House Fan: No
City, State, Zip: FT PIERCE,
Family Type:
Single-family
FL, 34950
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating Design Daily Temp
V Design
Location
TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture Range
FL, West Palm Beach FL WEST_PALM_BEAC 44 90
70
75 316 60 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
1340 15544
2
Block2
1754 17978.5
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
LIIVING
1340 15544 Yes 2
0
1 Yes Yes Yes
2
BEDROOMS
1754 17978.5 No 8
4
1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio LIIVING 69 ft 1
1340 ft2
---- 1 0 0
2 Slab -On -Grade Edge Insulatio BEDROOMS 174 ft 1
1754 ft2
---- 1 0 0
ROOF
Roof Gable Roof
Rad
Solar SA Emitt Emitt Deck Pitch
V #
Type
Materials Area Area Color
Barr
Absor. Tested Tested Insul. (deg)
1
Hip
Metal 3351 ft2 0 ft2 Light
N
0.75 No 0.9 No 2 22.6
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 300 3094 ft2
N Y
10/9/2019 1:02 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORNd.R405-2017 INPUT SUMMARY CHECKLIST REPnRT
CEILING
. #
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Vented) LIIVING
30
Blown
1340 ft2
0.11
Wood
2
Under Attic (Vented) BEDROOMS
30
Blown
1754 ft2
0.11
Wood
WALLS
Adjacent Space
Cavity
Width Height
Sheathing Framing Solar
Below
Ornt
To
Wall Type
Able
Ft
In Et
In
Area
R-Atallie
Eractonn Ahqnr
r4rarle%
_ 1 S
Exterior
Concrete Block - Int Insul LIIVING
4.0999
30
0 11
4
340.0 ft2
2
0 0.75
0
_ 2 E
Exterior
Concrete Block - Int Insul LIIVING
4.1
16
4 11
4
185.1 ft2
2
0 0.75
0
3 N
Exterior
Concrete Block - Int Insul LIIVING
4.1
27
0 11
4
306.0 ft2
2
0 0.75
0
_ 4 N
Exterior
Concrete Block - Int InsiREDROOMS
4.1
16
6 9
4
154.0 ft2
2
0 0.75
0
5 E
Exterior
Concrete Block - Int Ins®EDROOMS
4.1
30
4 11
4
343.8 ft2
2
0 0.75
0
6 S
Exterior
Concrete Block - Int InsfiIEDROOMS
4.1
34
4 9
4
320.4 ft2
2
0 0.75
0
7 N
Exterior
Concrete Block - Int InsfIEDROOMS
4.1
20
4 11
4
230.4 ft2
2
0 0.75
0
8 W
Exterior
Concrete Block - Int InsfBEDROOMS
4.1
57.7
9
4
538.5 ft2
2
0 0.75
0
9 W
Exterior
Concrete Block - Int InsMEDROOMS
4.1
12
4 11
4
139.8 ft2
2
0 0.75
0
10 E
Garage
Concrete Block - Int Ins®EDROOMS
4.1
23
4 11
4
264.4 ft2
2
0 0.75
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
N
Insulated LIIVING
Metal
.2
6
8
48 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
Wall
Overhang
#
Ornt ID
Frame Panes NFRC U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
S 1
Metal Single (Tinted) Yes
0.65
0.25
Y
96.0 ft2
14 ft 4 in
3 ft 4 in
Drapes/blinds
None
2
S 1
Metal Single (Tinted) Yes
0.65
0.25
Y
36.0 ft2
2 ft 0 in
3 ft 4 in
Drapes/blinds
None
3
E 2
Metal Single (Tinted) Yes
0.65
0.25
Y
64.0 ft2
49 ft 0 in
3 ft 4 in
Drapes/blinds
None
4
N 3
Metal Single (Tinted) Yes
0.65
0.25
Y
36.0 ft2
12 ft 0 in
1 ft 4 in
Drapes/blinds
None
5
N 3
Metal Single (Tinted) Yes
0.65
0.25
Y
12.0 ft2
17 ft 0 in
0 ft 6 in
Drapes/blinds
None
6
S 6
Metal Single (Tinted) Yes
0.65
0.25
Y
96.0 ft2
14 ft 0 in
3 ft 4 in
Drapes/blinds
None
7
N 7
Metal Single (Tinted) Yes
0.65
0.25
Y
27.0 ft2
2 ft 0'in
3 ft 4 in
Drapes/blinds
None
8
W 8
Metal Single (Tinted) Yes
0.65
0.25
Y
8.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
None
9
W 8
Metal Single (Tinted) Yes
0.65
0.25
Y
45.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
None
10
N 3
Metal Single (Tinted) Yes
0.65
0.25
Y
12.0 ft2
12 ft 0 in
1 ft 4 in
Drapes/blinds
None
11
N 4
Metal Single (Tinted) Yes
0.65
0.25
Y
27.0 ft2
12 ft 0 in
1 ft 4 in
Drapes/blinds
None
12
S 6
Metal Single (Tinted) Yes
0.65
0.25
Y
9.3 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
None
10/9/2019 1:02 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM, R405-2017 INPUT SUMMARY CHECKLIST REPORT
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
588 ft2
588 ft2
72 ft 9.3 ft 1
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse
Proposed ACH(50)
.00031
2513.5 137.99 259.51 .1419 4.4988
HEATING SYSTEM
#
System Type
Subtype
Efficiency Capacity Block
Ducts
1
2
Electric Strip Heat/
Electric Strip Heat/
None
None
COPA 26.2 kBtu/hr 1
COPA 32.8 kBtu/hr 2
sys#1
sys#2
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1
2
Central Unit/
Central Unit/
Split
Split
SEER: 16 36 kBtu/hr 1200 cfm 0.75 1
SEER: 16 42 kBtu/hr 1400 cfm 0.75 2
sys#1
sys#2
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Electric None
Garage
0.88 65 gal 70 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None
None
ft2
DUCTS
#
--- Supply ---
Location R-Value Area
-- Return - - Air CFM 25 CFM25
Location Area Leakage Type Handier TOT OUT QN RLF
HVAC #
Heat Cool
1
2
Attic 6 240 ft2
Attic 6 320 ft2
Attic
Attic
66 ft2 Default Leakage Garage (Default) (Default)
90 ft2 Default Leakage Garage (Default) (Default)
1 1
2 2
10/9/2019 1:02 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017)_ Compliant Software Page 4 of 5
0 . .:
FORM R405-2017 INPUT-RUMMORY rHFrKI IAT RFPnPT
TEMPERATURES
,Programable Thermostat: Y
Ceiling Fans:
Heating Jan
Mar
Apr
X� Jul
X� Aug
] Oct
Nov
Dec
[X�
�Feb
r
Rj
�X� AprX�
�Jun
May �X
XSep
J
�X�
[X Jan
Feb
Mar
Jun
[X Jul
[X Aug
[X Sep
L�] Oct
Nov
X� DecVenting
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78 78
78
78
78
80
80
80
80
PM
80
80
78
78 78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78 78
78
78
78
78
78
78
78
PM
78
78
78
78 78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66 66
68
68
68
68
68
68
68
PM
68
68
68
68 68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66 66
68
68
68
68
68
68
68
PM
68
68
68
68 68
68
68
68
68
68
66
66
MECHANICAL VENTILATION
Type
Supply CFM
Exhaust CFM Fan Watts HRV Heating System
Run Time Cooling System
Fans/ERV
50
50
80 50
1 - Electric Strip Heat
1 %
1 - Central Unit
Fans/ERV
200
200
250 50
2 - Electric Strip Heat
1 %
2 - Central Unit
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
Oft
0.3
LIIVING
Default 8 Ibs/s
.ft.
0 ft2
0 ft
0.3
BEDROOMS
10/9/2019 1:02 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5