HomeMy WebLinkAboutKoval Atlas Armor NOA%MEMIAMI FPiiVkT • �1 1 • 1 • 1 1 • 1 • NOTICE OF ACCEPTANCE (NO Atlas Armor, Inc. 1101 Holland Drive, Suite 16 Boca Raton, Florida 33487 SCOPE: MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.m iamidade.gov/economy This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER- Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: "Atlas Armor Hurricane Screens" Flexible Wind Abatement System APPROVAL DOCUMENT: Drawing No. AD12-60, titled "Atlas Armor Hurricane Screens", sheets 1 through 10 Of 10, prepared by -MC Engineering, Inc., dated March 04, 2019, last revision #2 dated March 04, 2019, signed and sealed by Yiping Wang, P.E., bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and the expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each panel shall bear a permanent label with the manufacturer's name or logo, city, state, the following statement: "Miami -Dade County Product Control Approved and NOA number, per TAS-201, TAS- 202, and TAS-203, unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA #17-0426.11 and consists of this page 1, evidence submitted pages E-1, E-2, E-3 & E4 as well as approval document mentioned above. The submitted documentation was reviewed by Helmy A. Makar, P.E. M.S. MIAMMADE COUNTY NOA No. 19-0415.03 f �'ow r f Expiration Date: 04/18/2023 Approval Date: 06/06/2019 061 Pagel Atlas Armor, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL #12-1107.05 A. DRAWINGS 1. Drawing No. AD12-60, titled "Gladiator Screening Systems ", sheets 1 through 10 Of 10, prepared by MCY Engineering, Inc., dated April 03, 2013, signed and sealed by Yiping Wang, P.E., on April 04, 2013. B. TESTS 1. Test report on Uniform Static Air Pressure Test of Gladiator Screening System Flexible Hurricane Wind Abatement System, prepared by Hurricane Engineering & Testing, Inc., Report No. HETI-11-3340, dated December 12, 2011, signed and sealed by Rafael E. Droz-Seda, P.E. 2. Test report on Large Missile Impact Test and Cyclic Wind Pressure Test of Gladiator Screening System Flexible Hurricane Wind Abatement System, prepared by Hurricane Engineering & Testing, Inc., Report No. HETI41-3341, dated December 12, 2011, signed and sealed by Rafael E. Droz-Seda, P.E. 3. Test report on Uniform Static Air Pressure Test of Gladiator Screening System Flexible Hurricane Wind Abatement System, prepared by Hurricane Engineering & Testing, Inc., Report No. HETI41-3343, dated December 12, 2011, signed and sealed by Rafael E. Droz-Seda, P.E. 4. Test report on Large Missile Impact Test and Cyclic Wind Pressure Test of Gladiator Screening System Flexible Hurricane Wind Abatement System, prepared by Hurricane Engineering & Testing, Inc., Report No. HETI41-3336, dated December 12, 2011, signed and sealed by Rafael E. Droz-Seda, P.E. 5. Test report on Large Missile Impact Test and Cyclic Wind Pressure Test of Gladiator Screening System Flexible Hurricane Wind Abatement System, prepared by Hurricane Engineering & Testing, Inc., Report No. HETI424057, dated September 21, 2012, signed and sealed by Rafael E. Droz-Seda, P.E. 6. Test report on Uniform Static Air Pressure Test of Gladiator Screening System Flexible Hurricane Wind Abatement System, prepared by Hurricane Engineering & Testing, Inc., Report No. HETI424056, dated September 21, 2012, signed and sealed by Rafael E. Droz-Seda, P.E. 7. Test report on Uniform Static Air Pressure Test of Gladiator Screening System Flexible Hurricane Wind Abatement System, prepared by Hurricane Engineering & Testing, Inc., Report No. HETI41-3335, dated December 12, 2011, signed and sealed by Rafael E. Droz-Seda, P.E. 8. Test report on Uniform Static Air Pressure Test of Gladiator Screening System Flexible Hurricane Wind Abatement System, prepared by Hurricane Engineering & Testing, Inc., Report No. HETI424060, dated September 21, 2012, signed and sealed by Rafael E. Droz-Seda, P.E. w J11&141� ° elmy A. Makar, P.E., M.S. Product Control Section Supervisor NOA No. 19-0415.03 Expiration Date: 04/18/2023 Approval Date: 06/06/2019 E-1 AtiaS Armor, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 9. Test report on Large Missile Impact Test and Cyclic Wind Pressure Test of Gladiator Screening System Flexible Hurricane Wind Abatement System, prepared by Hurricane Engineering & Testing, Inc., Report No. HETI424061, dated September 215 2012, signed and sealed by Rafael E. Droz-Seda, P.E. 10. Compressive Strength of Cylindrical Concrete Specimens, per ASTM C39-12, prepared by Hurricane Engineering & Testing, Inc., Report No. HETI41-C173, dated October 02, 2012, signed and sealed by Rafael E. Droz-Seda, P.E. 11. Compressive Strength of Grout, per ASTM C3942, prepared by Hurricane Engineering & Testing, Inc., Report No. HETI-11-072, dated October 02, 2012, signed and sealed by Rafael E. Droz-Seda, P.E. 12. Breaking Strength and Elongation of Textile Fabrics Grab Test per ASTM D 5034-09 prepared by Hurricane Engineering & Testing, Inc., Report No. HETI42-T121, dated September 21, 2012, signed and sealed by Rafael E. Droz-Seda, P.E. 13. Breaking Strength and Elongation of Textile Fabrics Grab Test per ASTM D 5034-09 prepared by Hurricane Engineering & Testing, Inc., Report No. HETI42-T122, dated September 21, 2012, signed and sealed by Rafael E. Droz-Seda, P.E. 14. Sewn Seams Strength Using Grab Tensile Test per ASTM D 1683.11 a prepared by Hurricane Engineering & Testing, Inc., Report No. HETI42-T123, dated September 21, 2012, signed and sealed by Rafael E. Droz-Seda, P.E. 15. Breaking Force and elongation of Textile fabrics per ASTMD 63840/ASTMD 5035- 11 prepared by Hurricane Engineering & Testing, Inc., Report No. HETI42-U108, dated July 24, 2012, signed and sealed by Rafael E. Droz-Seda, P.E. 16. Breaking Force and elongation of Textile fabrics per ASTMD 638.10/ASTMD 5035- 11 prepared by Hurricane Engineering & Testing, Inc., Report No. HETI42-U109, dated July 24, 2012, signed and sealed by Rafael E. Droz-Seda, P.E. 17. Accelerated Weathering Using Xenon Arc light Apparatus per ASTM G 155-05a prepared by Hurricane Engineering & Testing, Inc., Report No. HETI42 A403, dated July 24, 2012, signed and sealed by Rafael E. Droz-Seda, P.E. 18. Test report on Large Missile Impact Test and Cyclic Wind Pressure Test of Gladiator Screening System Flexible Hurricane Wind Abatement System, prepared by Hurricane Engineering & Testing, Inc., Report No. HETI-11-3345, dated December 12, 2011, signed and sealed by Rafael E. Droz-Seda, P.E. 19. Test report on Large Missile Impact Test and Cyclic Wind Pressure Test of Gladiator Screening System Flexible Hurricane Wind Abatement System, prepared by Hurricane Engineering & Testing, Inc., Report No. HETI41-3344, dated December 12, 2011, signed and sealed by Rafael E. Droz-Seda, P.E. 0 Helmy A. Makar, P.E., M.S. Product Control Section Supervisor NOA No. 19-0415.03 Expiration Date: 04/18/2023 Approval Date: 06/06/2019 E-2 Atlas Armor, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED C. CALCULATIONS 1. Comparative Analysis and Anchor calculations dated November 03, 2012, Pages L-1, L-2, D-1, TR-1, A-1 through A-31, R-1 through R-3, T-1 through T-SS, prepared by MCYEngineering, Inc., signed and sealed by Yiping Wang, P.E. D. QUALITY ASSURANCE 1. By Miami -Dade County Department of Regulatory and Economic Resources. E. MATERIAL CERTIFICATIONS 1. Fabric specifications. 2. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL #14-0811.17 A. DRAWINGS 1. Drawing No. AD12-60, titled "Gladiator Screening Systems ", sheets 1 through 10 Of 10, prepared by MCYEngineering, Inc., dated April 03, 2013, last revision #1 dated October 13, 2015, signed and sealed by Yiping Wang, P.E. B. TESTS 1. None. C. CALCULATIONS 1. Anchor calculations dated October 12, 2015, Pages L-1, L-2, D-1, TR-1, A-1 through A-36, R-1 through R-S, prepared by MCY Engineering, Inc., signed and sealed by Yiping Wang, P.E., on October I5, 2015. D. QUALITY ASSURANCE 1. By Miami -Dade County Department of Regulatory and Economic Resources. E. MATERIAL CERTIFICATIONS 1. Fabric specifications. E-3 ' Helmy A. Makar, P.E., M.S. Product Control Section Supervisor NOA No. 19-0415.03 Expiration Date: 04/18/2023 Approval Date: 06/06/2019 Atlas Armor, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 3. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL #17-0426.11 A. DRAWINGS 1. None. B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. By Miami -Dade County Department of Regulatory and Economic Resources, E. MATERIAL CERTIFICATIONS 1. None. 4. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. AD12-60, titled "Atlas Armor Hurricane Screens ", sheets 1 through 10 Of 10, prepared by MCY Engineering, Inc., dated March 04, 2019, last revision 92 dated March 04, 2019, signed and sealed by Yiping Wang, P.E. B. TESTS 1. None, C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. By Miami -Dade County Department of Regulatory and Economic Resources. E. MATERIAL CERTIFICATIONS 1. None. E-4 Helmy A. Makar, P.E., M.S. Product Control Section Supervisor NOA No. 19-0415.03 Expiration Date: 04/18/2023 Approval Date: 06/06/2019 0 0 N TRACK TO TRACK (TT) 230" MAX. SPAN SCREEN WIDTH Ya" TEKS SCREWS- 1 21" FROM EA. END & 43" O.C. MAX. TYP. h �w Ow = W U� Z Q I - r I � I I �I I �I l J IMPACT RESISTANT y �'� - I I �I I I I �I l I (SEE CHART ON � � �PP. SHEET 3) z z g � ran fcn� w w 4 CV 1 - 1 ATLAS ARMOR HURRICANE SCREEN SYSTEM WITH HOUSING GENERAL NOTES: a (SEE CHART ON SHEET 3) DESIGN LOADS V.S. SCREEN WIDTH SEE CHART ON SHEET 3 —Ya" TEKS SCREWS 21" FROM EA. END & 43" O.C. MAX. TYP. -THE ROLLING SCREEN SYSTEM IS NON -POROUS LARGE/SMALL MISSILE IMPACT PROTECTION -ANCHORING OR LOADING CONDITIONS NOT SHOWN IN THESE DETAILS ARE NOT PART OF THIS APPROVAL DEVICE. IT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE 6TH EDITION FLORIDA BUILDING CODE (2017) EDITION. FOR USE INSIDE OF THE HIGH -MATERIALS INCLUDING BUT NOT LIMITED TO METAL SCREWS THAT COME INTO CONTACT WITH OTHER VELOCITY HURRICANE ZONE (HVHZ). DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE 6TH EDITION FLORIDA BUILDING CODE (2017) -THIS PRODUCT HAVE BEEN TESTED AS PER FBC 2017 TAS 201, 202 (STRUCTURAL WIND LOAD ONLY) AND 203 FOR LARGE/SMALL MISSILE IMPACT. THE SYSTEM IS ALSO TESTED AS PER ASTM D635-06, ASTM D2843-99, ASTM D1929-96 AND ASTM G155. -THIS PRODUCT HAS SUCCESSFULLY PASSED THE EXTENDED WEATHERING TEST (ASTM G-155) FOR DAILY USAGE IN FULL SPECTRUM SUNLIGHT. - DESIGN LOAD SHALL BE DETERMINED BASED ON BASIC WIND SPEED, BUILDING HEIGHT AND WIND ZONE USING APPLICABLE ASCE 7-10 STANDARD. - DESIGN LOAD OBTAINED FROM ASCE 7-10 (ULTIMATE LOAD), MULTIPLY BY 0.6, SHALL BE LESS THAN OR EQUAL TO MAX. DESIGN LOAD IN THIS DOCUMENT. - ANCHORS SHALL BE AS LISTED, SPACED AS SHOWN ON DETAILS. ANCHORS EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO.. SECTION AS APPLICABLE. - IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR/E.O.R. TO VERIFY THAT THE EXISTING STRUCTURE OR APPROVED MULLION IS DESIGNED TO SUPPORT Fx & Fy FORCES AT END OF TRACK. FOR Fx & Fy REFER TO CHART ON SHEET 3. - ROLLUP MECHANISM IS NOT PART OF THIS APPROVAL. CARE SHOULD BE TAKEN WHEN SCREEN IS IN MOTION TO ENSURE THAT PERSONAL INJURY OR DAMAGE TO THIS PRODUCT DOES NOT OCCUR. -ALL SCREEN PANELS SHALL BE PERMANENTLY LABELED, IN A READILY VISIBLE LOCATION, WITH AT LEAST ONE LABEL STATING: ATLAS ARMOR, INC. 22909 IRONWEDGE DRIVE BOCA RATON, FL 33433 MIAMI DADS COUNTY PRODUCT CONTROL APPROVAL MIAMI DADE COUNTY F.LORIfiJA'REGISTRATfON PE #55983 CQN. ' 286i DATE 03-04-2019 SCALE AS NOTED DRAWN yR7 PROJECT MCY 12-135 DRAWING AD12-60 N0. SHEET 1 OF 10 x Q C v CV i i /� � � / O � I I I 1 o L'' N �� ///// (2) STI CHINGS z_ �� � � � 'v H � � � m � � � � � �/ i - -- - -' � AT TOP AND TWO V DETAIL EDGES FOR ROLL D SCREEN WIDTH SCREEN ELEVATION OTH SIDES SUPPORT -'- - �, �� � � ��� (8) STITCHINGS �� i FULL LENGTH � � (2) EXTRA �� � STITCHINGS 12" � � LONG AT EACH � � � END j I � \ � � i � i � i � � ERTICAL ��-----'� OWN SCREEN �� DETAIL ALL EDGES ON FIXED SCREEN. ��a PP. 19a :h ATLAS ARMOR HURRICANE SCREEN SYSTEM WITHOUT HOUSING (L.M.I. & S.M.I) SCREEN ELEVATION TOP &BOTTOM SUPPORT DESIGN LOADS V.S. SCREEN WIDTH SEE CHART ON SHEET 3 a �i R R Z V Z� V Z Z F � � W� W Z Z O WQ J V � H ;'ail AMV, M as Fr F� HART FOR DESIGNLOAD VS. SPAN AND ANCHOR SPAIG o M E PC z F ANCHOR SPACING (IN.) A END REACTIONS GLASS MAX. SPAN / AT TRACK SEPARATION o DESIGN SCREEN F A DETAIL A DETAIL B DETAIL C z LOAD WIDTH (PSF) (INCHES) Fx Fy a OPTION 1 OPTION 2 OPTION 3 OPTION 4 OPTION 1 OPTION 2 OPTION 3 OPTION 4 OPTION 1 OPTION 2 OPTION 3 OPTION 4 0 t O a LBS/FT LBS/FT IN. CONCR, CONCR. STEEL ALUM. WOOD CONCR. CONCR. STEEL ALUM, WOOD CONCR, CONCR, STEEL ALUM. WOOD 0 TO 84.0 602 175 9.7 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 4.9 5.5 5.5 5.5 5.5 5.5CD 120.0 - 685 250 15.0 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 4.2 5.5 5.5 5.5 5.5 5.5 C <_ 50 156.0 734 325 21.7 5.5 5.5 5.5 5.5 5.0 5.5 5.5 5.5 5.5 3.9 5.5 5.5 5.5 5.5 5.0 U co 192.0 761 400 29.9 5.4 5.5 5.5 5.5 4.5 5.4 5.5 5.5 5.5 - 5.5 5.5 5.5 5.5 4.7 Z 230.8 774 481 40.6 5.0 5.5 5.5 5.3 4.0 5A 5.5 5.5 5.5 - 5.5 5.5 5.5 5.5 4.5 Z h <_ 65 0 TO 72 732 195 9.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 4.1 5.5 5.5 5.5 5.5 5.3 0� LO D o WZ 0 TO 84.0 964 280 9.7 5A 5.5 5.5 5.3 4.6 - 5.5 5.5 5.3 - 5.5 5.5 5.5 5.5 4.0 W o F z ° 80 120.0 1097 400 15.0 - 5.5 5.5 4.4 3.7 - 4.8 5.5 4.5 - 5.5 5.5 5.5 5.5 5.5 0 � m 156.0 1175 520 26.8 - 4.9 5.5 3.9 3.2 - - 5.5 4.0 - 5.5 5.5 5.5 5.5 - w N 0 JCO bL <_ 100 0 TO 79.0 1205 350 10.0 - 5A5.5 4.2 3.7 - 4.5 5.3 4.2 - 5.5 5.5 5.5 5.5 - O LO co Fy /� Fy 1" X 2" X 1/8" THK. \ ALUMINUM COVER \ ANGLE. 2 5/8" LG, Fx Fx 06 06 1 " X 2" X 1/8" TH K. I ALUMINUM COVER ------------- t----------------- O ANGLE. 3 1/4" LG. z i w w 0 wM z >! M Fy Fy p M � a W c o w Z 0 z 1/4-20 X 3/4" JACKNUT V ON Q o C RETENTION ANCHOR U) a a v (1) PER ANGLE _J a N m a � 0 75 2 5/8" 3 1/4" Q J Ico F i Q --- YIPiNG R.E. iWANG; FLORIDA . REGtSTRATON 1" X 2" X 1/8" THK. _b= :, PE #55983 DATE 03-o4-zo�a ALUMINUM ANGLE w.�.� c.A.y. 2as77,. sOntE NOTED 1/4-20 X 3/4" JACKNUT 1§ DRAWN '� RETENTION ANCHOR in PROJECT MOY i2-�36 (1) PER ANGLE- DRAWING NO. AD12-60 MIAMI DADE COUNTY SHEET 3 OF 10 5 Z_ I" �0 1/4-14SIDS AT 2'.',3- �° 1/2" FROM BOTTOM M & 4" Q.C. CONCRETE 5/16' DIA. ULTRACON W/ 2" MIN EMBEDMENT INTO CONCRETE. FOR SPACING SEE CHART ON SHEET 3 5/16" DIA. ULTRACON W/ 2" MIN EMBEDMENT INTO CONCRETE. FOR SPACING SEE CHART ON SHEET 3 g 2 12 OR 1 I 1/4 - 14 SIDS AT� 2", 3 1/2" FROM BOTTOM & 4" O.C. C3 (TT) TRACK TO TRACK (FW) FINISHED WIDTH A OPTION 1 DETAILS WITH HEAVY DUTY TRACKS z� U) �o w 1/4-14SDSAT- M o 21113 1/2" FROM UJ BOTTOM & 4" O.C. CONCRETE 5/16" DIA. ULTRACON W/ 2" MIN EMBEDMENT INTO CONCRETE, FOR SPACING SEE CHART ONSHEET3 3) 7—1 g l 10 1 TRACK TO TRACK (FW) FINISHED WIDTH A OPTION 1 ANCHOR 5/16" DIA. ULTRACON BY'ELCO' (Fy=155 ksi Fu = 177 ksi) 1/4 - 14 SDS AT-- 2", 3 1/2" FROM BOTTOM & 4" O.C. C3 3 1/8" MIN, 5/16" DIA. ULTRACON W/ 2" EDGE DIST, MIN EMBEDMENT INTO CONCRETE, FOR SPACING EE CHART ON SHEET 3 CONCRETE fc'=3515 PSI 3 1/8" MIN, MIN. EDGE DIST, TYR 9 CONCRETE fc'=3515 PSI I I 1 i 1 f 2 / 5/8" 3 9 2 5/8" (TT) TRACK TO TRACK 2 5/8" (TT) TRACK TO TRACK (FW) FINISHED WIDTH (FW) FINISHED WIDTH B OPTION 1 3 1/8" MIN. EDGE`DIST. ` CONCRETE fc'=3515 PSI MIN 5/16" DIA. ULTRACON W/ 2" MIN EMBEDMENT INTO CONCRETE, FOR SPACING SEE CHART ON SHEET 3 C OPTION 1 5/16" DIA. ULTRACON W/ 2" MIN EMBEDMENT INTO CONCRETE. FOR SPACING SEE CHART ON SHEET 3 3 1/8" MIN, 1"x3"x1/4 OR EDGE DIST, MIN. 2"x3"x1/4 OR YP 2" x 4" x1/4" THK. c ALUM. TUBE CONCRET fc'=3515 PSI F1 4 r� ti 3 1/4" U � (TT) TRACK TO TRACK (FW) FINISHED WIDTH B OPTION 1 ATTACHMENT TO CONCRETE fc= 3515 PSI MIN. 0 pi -� 3 1/4" 1 � (TT) TRACK TO TRACK (TT) TRACK TO TRACK (FW) FINISHED WIDTH OPTION 1 C t a co W �Z00 (aj Qoom � � J Boa N m = a O a J a YIPLNG 1�JANG, P.F. .FLOf7}DA REGI57}7/tTION "— aPE ; 55983 DATE 03-04-2019 C.A.N. 28677 SCALE AS NOTED DRAWN yIN �f4er PROJECT MCY 12-135 DRAWING N0. ff a Ja�.v. _�:1s�f F ~ AD12-60 MIAMI DADE COUNTY SHEET 4 OF 10 MAR 2 1 2019 DETAILS !A'D TRACKS H zU) �ILL] M Q w CONCRETE 3/4" fc'=3000 PSI MIN A OPTION 2 3" MIN EDGE DIST. 3/8" POWERS WEDGE BOLT 5 W/ 2 1/2" MIN. EMBEDMENT INTO CONCRETE. FOR 3" MIN, SPACING SEE CHART ON EDGE DIST. 3/8" POWERS WEDGE BOLT W/ SHEET 3 2 1/2" MIN. EMBEDMENT INTO CONCRETE CONCRETE. FOR SPACING SEE fc'=3000 PSI MIN CHART ON SHEET 3 / CJ /� CONCRETE / �J/ f '-3000 PSI MIN 1/4 - 14 SDS 3 1/2" FROM BOTTOM &4"O.C. DETAILS WITH HEAVY DUTY TRACKS 5 3/8" POWERS WEDGE BOLT W/ 1/4 - 14 SDS 3 1/2" FROM BOTTOM & 4110 .C. 3/4 B OPTION 2 CONCRETE. FOR SPACING SEE CHART ON SHEET 3 3/4" 9 12 OR 6 � 1 z o - a ih r CONCRETE _ fc'=3000 PSI MI 3/4" 3 10 1/4 - 14 SIDS 3 1/2" 3 1/4" (TT) TRACK TO TRACK FROM BOTTOM & 4" O.C. (FW) FINISHED WIDTH A OPTION 2 ANCHOR 3/8" DIA. WEDGE BOLT BY: "POWERS" Fu =100 KSI Fy= 65KS1 3" MIN. EDGE DIST. CONCRETE fc'=3000 PSI MIN m 3/8" POWERS WEDGE BOLT W/ 2 1/2" MIN. EMBEDMENT INTO CONCRETE, FOR SPACING SEE CHART ON SHEET 3 1/4 - 14 SDS 3 1/2" FROM BOTTOM & y) 1 (Ti TRACK TO TRACK (FW) FINISHED WIDTH B OPTION 2 3 3" MIN. -;EDGE DIST. 10 (FW) FINISHED WIDTH C OPTION 2 o� xE 0 U h0 c- � �t ao o � co U c zF 1, �z a 8 Q 3/8" POWERS WEDGE BOLT W/ Z J Lo 2 1/2" MIN. EMBEDMENT INTO W 0 8 CONCRETE. Z uJ w 0 OPTION 2 Z 0 co ab C C W N �� G Q � oo 3/8" POWERS WEDGE BOLT W/ V w 2 1/2" MIN, EMBEDMENT INTO co CONCRETE. FOR SPACING SEE CHART ON SHEET 3 Go otS M co 00 w z �o a z�-^ � Q oUa N O a a a YIPING`WANG, .P;f.. `. FLORIDA-'REI�fSTRATIQN , PEJ55983 DATE 03-04-2019 €,sr d St- C.A.N. 28677I SCATS AS NOTED .DRAWN YIN x PROJECT RCY 12-135 4 p / t ( DRAWING N0. AD12-60 MIAMI DADE COUNTY SHEET 5 OF 10 1 (TT) TRACK TO TRACK 5 5/16"-12 S/S TEKS INTO 1/4" THK STEEL OR ALUMINUM, FOR SPACING SEE CHART ON SHEET 3 3 9 2 1/4 - 14 SDS 3 1/2" FROM BOTTOM OPTION 3 A -- DETAILS WITH HEAVY DUN TRACKS N� 1/4 - 14 SDS 3 1/2" FROM BOTTOM 5/16"-12 S/S TEKS INTO 1!4" THK STEEL OR ALUMINUM. FOR SPACING SEE CHART �N SHEET 3 3/4 1/4" THK. MIN. STEEL OR MIAMI-DADE COUNTY APPROVED ALUM. MULLION 5/16"-12 S/S TEKS INTO 1/4" THK STEEL OR ALUMINUM, FOR SPACING SEE CHART pN SHEET 3 IN. 1/4" THK. MIN. STEEL fP � MIAMI-DADE COUNT APPROVED ALUM. M I 0" IN. YP. I 5/16"-12 S/S TEKS INTO 1/4" THK STEEL OR ALUMINUM. FOR SPACING SEE CHART �N SHEET 3 1/4" THK. MIN. STEEL OR MIAMI-DADE COUNTY _ APPROVED ALUM. MULLIO C OPTION 3 1/4" THK. MIN. STEEL O MIAMI-DADE COUNTY APPROVED ALUM. LLION 5/16"-12 S/S TEKS INTO 1/4" THK STEEL OR ALUMINUM. FOR SPACING SEE CHART ON SHEET 3 E 5/16"-12 S/S TEKS INTO 1/4" THK STEEL OR ALUMINUM. �1 FOR SPACING SEE CHART � - � MIN. TYP. ON SHEET 3 0" MIN. 9 12 OR 6 3/4" I 9 TYP. 1/4-14SDS31/2" 1 1 3 3 1/4" 1� (TT) TRACK TO TRACK FROM BOTTOM - 1/4 - 14 SDS 3 1/2" - l`' & 4" O.C. � FROM BOTTOM a _ � & 4" O.C. (FW) FINISHED WIDTH �c7 1/4" THK. MIN. STEEL OR MIAMI-DADE COUNTY APPROVED ALUM. MULL 10 (FW) FINISHED WIDTH OOPTION 3 TRACK TO TRACK ANCHOR 5/16" ST./ST. TEKS SCREW Fu=100 KSI Fy= 65 KSI Ec3 m (FW) FINISHED WIDTH B OPTION 3 TRACK TO TRACK ATTACHMENT TO STEEL/ALUM. A36TOR 6063-T5 MIN. 1/4" MIN. THK C OPTION 3 0 1/4 14 S 3 1/2" w ROM B TTOM Mo WOOD BUC I WOOD STRUCTUR SG=0.55 MIN 5/16" O ULTRACONS W/ 2" MIN EMBEDMENT INTO WOOD. FOR SPACING SEE CHART ON SHEET 3 5/16" PJ ULTRACONS W/ 2" MIN EMBEDMENT INTO WOOD. FOR SPACING SEE CHART ON SHEET 3 i 1 FROM BOTTOM 2 5/8" � (TT) TRACK TO TRACK (FW) FINISHED WIDTH A OPTION 4 DETAILS WITH HEAVY DUTY TRACK 5 0 1/4 14 S 3 1/2" ROM B TOM M � WOOD BUC WOOD STRUCTUR SG=0.55 MIN 5/16" QJ ULTRACONS W/ 2" MIN EMBEDMENT INTO WOOD. FOR SPACING SEE CHART ON SHEET 3 5/16" O ULTRACONS W/ 2" MIN EMBEDMENT INTO WOOD. FOR SPACING SEE CHART ON SHEET 3 1 3 1/4" � (TT) TRACK TO TRACK (FW) FINISHED WIDTH A OPTION 4 ANCHOR 5/16" DIA. ULTRACONS BY'ELCO' (Fy=155 ksi Fu = 177 ksi) 3 1/4-14SDS31/2"- FROM BOTTOM C�-- 3 EDGE DIS3 1 2 5/8" (TT) TRACK TO TRACK (FW) FI—NIS�HED WIDTH �r,� OPTION 4 3 1/8" MIN. EDGE DISC OR WOOD STR 0 10 3 1/4" � (TT) TRACK TO TRACK (FW) FINISHED WIDTH 5/16" O ULTRACONS W/ 2" MIN EMBEDMENT INTO WOOD. FOR SPACING SEE CHART ON SHEET 3 3 1/8" MIN. EDGE DJ.� � D BUCKS WOOD STR URE SG=0.55 MI 2 2 5/8" (TT) TRACK TO TRACK (FW) FINISHED WIDTH C OPTION 4 C OPTION 4 5/16" QJ ULTRACONS W/ 2" MIN EMBEDMENT INTO WOOD. FOR SPACING SEE CHART ON SHEET 3 i FOl END OF FLAP ,� SCREEN BOTTOM EDGE LD C SUMMARY OF TEST RESULTS HURRICANE TEST DESCRIPTION TEST RESULT MIAMI DADE COUNTY ENGINEERING AND STANDARDS CRITERIA TESTING NUMBER ASTM D1929-96 SELF IGNITION TEMPERATURE (SIT) SIT=751°F ACCEPTABLE IF >650°F TEL-01700388C ASTM D635 RATE OF BURNING (CC1 / C-1) CC1/C-1 LESS THAN PASS IF < 1.0 IN./MIN HETI-12-F108 1.0 IN./MIN. ASTM D635 AVERAGE TIME OF BURNING - - - - - - HETI-12-F108 ASTM D635 AVERAGE EXTENT OF BURNING - - - - - - HETI-12-F108 ASTM D2843-99 SMOKE DENSITY (SDR) SDR=10.6% ACCEPTABLE IF <75% TEL-01700388E ASTM G155-05a ACCELERATED WEATHERING +7.2% DIFFERENCE ACCEPTABLE IF <10% HETI-12-A403 BREAKING STRENGTH &ELONGATION OF TEXTILE FABRICS HURRICANE TEST MAX. FORCE ELONGATION ENGINEERING AND TESTING NUMBER ASTM D638 &ASTM 473 Ib/in 98.6% HETI-12-U109 WEAK DIRECTION D5035-11 ASTM D638 &ASTM 438.8 Ib/in 94.80% HETI-12-U108 WEAK DIRECTION D5035-11 ASTM D1683-11A 231.7 Ib/in 25.00% HETI-12-T123 AT SEWN SEAMS ASTM D5034-09 742.6 Ib/in 19.60% HETI-12-T122 STRONG DIRECTION ASTM D5034-09 449.8 Ib/in 74.60% HETI-12-T121 WEAK DIRECTION i �'Ile�' �� SUBSTRATE; 1" (2) 5/16" TAPCONS 1 3/4" MIN. EMBED. AND 2 1/2" MIN. EDGE DISTANCE INTO MASONRY BALL BEARING ASSEMBLY OR SIMU FREE END PRODUCT COVER CUSTOM HOOD/BRACKET WALL MOUNT 1/4" TEKS SCREW (1) PER ROTOR TUBE 3.93 in x 3,93 in x 1/8" THK, STEEL BEARING PLATE WITH (4) 1/4" SMS WALL MOUNT BRACKET OPTIONS 1/8" ALUM. RIVETS OR #8 SS SIDS ROTOR TUBE MOTOR ASSEMBLY MIN. 0.040 ALUM, HOOD OCTOGONALTUBE SCREEN WEAVE ALTERNATE SQUARE HOUSING HOUSING ASSEMBLY DETAIL -OPTION NOT PART OF THIS NOA i 0.030" fd ARAMID (HORIZONTAL) 0.027" fd POLYESTER YARNS (VERTICAL) 1 SCREEN WEAVE SCREEN SPAN <_84" ALUMINUM ANGLE (6063-T6) 5 ALUMINUM TUBES (6063-T6) 6 2"x3"x1/4" OR 2"x4"x1/4" C 2 ALUMINUM GUIDE RAIL (6063-T6) 10 ALUMINUM GUIDE RAIL (6063-T6) o m 0 3 ALUMINUM GUIDE RAIL CAP (6063-T6) ALUMINUM ROLLER TUBE � (6063-T6) 2.000" 0 z� 000 a� N O 0 4 BOTTOM WEIGHT ITEM # Lu QTY. PROFILE DESCRIPTION MATERIAL MANUFACTURER/ REMARKS 1 AS READ. T03A15899 SCREEN WOVEN POLYESTER & ARAMID 0.045" THICK / TWITCHELL CORP. 2 2 EACH - STANDARD GUIDE RAIL ALUM. 6063-T6 ATLAS ARMOR 3 2 EACH - GUIDE RAIL CAP ALUM, 6063-T6 ATLAS ARMOR 4 1 OR 2 EACH - BOTTOM WEIGHT STEEL ATLAS ARMOR 4A AS REQD. - BOTTOM WEIGHT BAR/US PATENT NO. 9382752 ALUM, 6063-T6 ATLAS ARMOR 5 AS REQD. - ALUMINUM ANGLE ALUM. 6063-T6 ATLAS ARMOR 6 AS REQD. - ALUMINUM TUBE ALUM, 6063-T6 ATLAS ARMOR 7 AS REQD. - ROLLER TUBE ALUM. 6063-T6 ATLAS ARMOR 8 AS REQD. - ROLLER TUBE REINFORCEMENT ALUM, 6063-T6 ATLAS ARMOR 9 1 PER SIDE 0.325 DIX (3)1s" - BRAIDED ROPE POLYPROPYLENE ATLAS ARMOR 10 2 EACH - HEAVE DUTY GUIDE RAIL ALUM. 6063-T6 ATLAS ARMOR 11 AS REQD. - ROLLER TUBE REINFORCEMENT ALUM. 6063-T6 ATLAS ARMOR 12 AS REQD. - ALUMINUM TUBE ALUM. 6063-T6 ATLAS ARMOR 13 AS REQD. - ALUMINUM ANGLE COVER 1"x2"x1/8" ALUM. 6063-T6 ATLAS ARMOR 14 AS REQD. - SELF ADJUSTING BOTTOM BLADE ALUM, 6063-T5 ATLAS ARMOR 8 ROLLOR TUBE REINFORCEMENT I 11 ROLLOR TUBE REINFORCEMENT OPTION (6063-T6) (6063-T6) 3" 4" ALUMINUM TUBES (6063-T6) 12 1"x3"x1/4" OR 1"x4"x%4' 13 ALUMINUM ANGLE (6063-T6) 14 SELF ADJUSTING BOTTOM BLADE (ALU M. 6063-T5) 4A BOTTOM WEIGHT BAR F.IE6oik" RF68TT,FATION PE #55983 - Nf F-A. N; -. 77 n� .. 137 t. , t MIAMI DADE COUNTY o a o aBF U SwAA � ca�> Wm� A s o z®® off$ J G7 Z z M r two W O o"(o wzo U Q OOCN LO = Q N m O Q Q J Q DATE 03-04-2019 SCALE AS NOTED DRAWN YIPI PROJECT MCY 12-135 DRAM] N0. AD12-60 SHEET 10 OF 10