Loading...
HomeMy WebLinkAboutApprvd Polyglass Business & Professional Regulation BCIS Hprrle Log In User Registration HotTopirs Submit Surcharge Slats&Facts Publications Contact Us BCIS Site Map Links Search ba Product Appro►ral dpr USER:Public user This Product Approval has been induct AppMval Men>Pmduct or AqP Irc tion Search n AAppI catien List�Application Oetall reviewed and approved by Richard FL# FL5259-R29 Boyette, FL PE 42485 on 9/10/2020 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer POLYGLASS USA Address/Phone/Email 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (954)233-1330 Ext242 malpert@polyglass.com Authorized Signature Maury Alpert ma Ipert@palyg lass.com Technical Representative TECH REP Address/Phone/Email 1111 West Newport Center Drive Deerfield Beach, FL 33442 (866)802-8017 uspolyglasstechnical@polyglass.com Quality Assurance Representative QA REP Address/Phone/Email 1111 West Newport Center Drive Deerfield Beach, FL 33442 (888)410-1375 uspolyglasstechnical@polyglass.com Category Roofing Subcategory Underlayments Compliance Method Evaluation Report From a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/21/2022 Validated By John W. Knezevich, PE Validation Checklist-Hardcopy Received Certificate of independence EL5259 R29 CQI, 2019 01 ,Q$)I NIEMINE .p Referenced Standard and Year(of Standard) Standard year ASTM D1970 2015 ASTM D226 2009 ASTM D4798 2011 ASTM D6163 2008 ASTM D6164 2011 ASTM D6222 2011 ASTM D6509 2009 FM 4424 2011 FRSMRI April 2012 2012 UL 1892 2012 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/15/2019 Date Validated 10/16/2019 Date Pending FBC Approval 10/20/2019 Date Approved 12/10/2019 Summa of Products FL P Model,Number or No. Description 5259.1 vat'glass Roof RooM9 urWerfaYments Underiaymen[s Limits of Dee Installation Instructions Approved for use in 1141 No 115259 922 IL.2019Y Approved for use outside Hill Yes R29 df Impact Resistant: N/A Verified By: Robert Nianimen PE-59166 Design Pressure: +N/A/-622.5 Created by Independent Thirtl Party:Yes Other: 1.)The design pressure in this Evaluation Reports application relates to one particular FB259 R29 AE 2019 10 FINAL Y D - underlayment system(over concrete deck)for B23r W use under foam-on We systems(where the Created by Independent Third Party:Yes underlayment forms part of the load-path). Refer to ER Section SAA for other systems, other deck types and associated maximum design pressures.2.)Refer to ER Section 5 for other limits of use. eaex aax2 gouself Us::2601 Blair some been n a,�a='S R Lea Mma 9a .Sal_ yn.stets wnanm le an AalaEO tmployer. - ::hrvae,snl .. see ry mmailv0 this arson named,context mt,rmtea,mntaexat:m aere onneby from r he traditional Mail,ntyw I,,- Maetlarua T isane,pIn leeme thmeasttt s pup rc.:es ma a-consioner ,amsection naae actions,usen r IiRv listener!mormon 6s,Fmuotlimiem.re newith an man startss if.ry ohe- th one.me ThdaseKmalls pmNaNl maybe used tor hasNmmim n with the berms,Xomewr am.,, ixore ,ma record.uyoud nth wish to admily a pelone ,ease#,pese formal trc Cepetment with or¢mal attract wdkl con be Malls ava0ade bat the cook.To determine ifYou are a licensee Me [hpter<ss, ,fi5.,pleas tll[k hem. PpaUR Rpproeal ACepS: =4107WRE Credit Card Safe NEMO I etc. Certific'tar Of AuNwruatlan#33L55 0 353 Christian Street, Unit#13 Oxford, CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY EVALUATION .O Polyglass USA,Inc. Evaluation Report P12060.02.09-R25 1111 West Newport Center Drive FL5259-R29 Deerfield Beach,FL 33442 Date of Issuance:02/24/2009 (954)233-1230 Revision 25: 10/14/2019 SCOPE: This Evaluation Report is issued under Rule 61620-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E.for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 15"Edition(2017)Florida Building Code sections noted herein. DESCRIPnON: PDlyglass Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report Is valid until such time as the named product(s) Changes, the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named dient constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMOjetc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOjetc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request Of the Building Official. This Evaluation Report consists of pages 1 through 16. Prepared by: Is��r,�2o-ye^y. ; Robert J.M.Nleminen,P.E. Florida Registration No.59166,Florida DC4ANE1983 'P'M YS„°" The rammec aeaiaeneatmg was uumodsed by Ratert Nieminen,FE.on 10/14/2019.This scats not terse as an elMruninlly signM dosument. COMFUUMON OF INDEPENOENCE: 1. NEMOletc. does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMOletc.is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Martinet.P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,norwill acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMOletc. nor Robert Nieminen, P.E. are, In any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 02019 NEMO ETC,LLC OONEMOletc. ROOFING COMPONENT EVALUATION 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the gas Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Stases Year 1504.3.1 Wind Uplift FM 4474 2011 1504.3.1 Wind Uplift UL 1897 2012 1507.2.311507.1.1 Physical Properties ASTM 0226 2W9 1507.2.4/1507.1.1,1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical Properties FRSA/TRI April 2012 2012 1507.11.2 Physical Properties ASTM 1>6163 2008 1507.11.2 Physical Properties ASTM D61M 2011 1507.11.2 Physical Prop irtlas ASTM D6222 2011 1507,11.2 Physical Properties ASTM 06509 2009 TAS 110 Accelerated Weathering ASTM D4798 2011 3. REFERENCES: ET&V Exhappme tX� tender @mminalbn Reference px. Ego(TST E049) Wind Uplift 11757,0.01.1 0/13/2001 ERD ITST fore) Tensile adhesion RW390.04.15 W/03/2015 ERD ITST E049) Wind Uplift 1177eN.02 01/16/2003 ERD DST E(49) TM 103 P443W.30.14-RS M/18/2015 ERD(TST(049) Wind Uplift P1740.01.07 01/0/2007 ERD ton E049) Wind Uplift PLYG-sC0905.05.16-1 05/17/2016 ERD Urn 6M9) MM D1970 P51M.N.074 M/11/2W7 END roe 60491 A9M D1970 PLYG-SC30130.06.16-1 06/27/2016 ownsT60491 WMd Upuft P92EDA3.D8 03121/2008 00(13T60491 Tensile adhesim PLY65C10130.W.162 06/27/2015 ERD(M(iot9) Wind Uplift P30540.11.09-R1 11/30/2M ERD DST Rare) TM 103 PLYG-SC30130.06.16-3 06/27/2016 ERD ITST ants) Tensile Adhesion P3203( 1.09-1 11/30/20(9 ERD(TST6049) ASTM D3970/N790 PLYG-sC0080A7.16 07/I6/2016 ERDUST6049) Wind Uplift P11030.11.092 11/30/I009 ERD(TST60,19) Wind Unift PLYG-5C32025.10.16 10/12/2016 ERD DST 6049) ASTM N977 P11030.11.09-3 11/30/2009 ERD( 5T 6049) TAS 103 PLYG-SC13W0.12.16 12/27/2016 ERD UST aci ASTM o19]0 P33360.H&W 061nnola £RO COST 60491 30(90 phytivk PLYG-SC11901A3.17 03/10(2017 ERD DSi We) TAS 103 P39370.0111 03/02/2011 ERD DST(N9) TM 103 PLYG-SC32115A8.17 08/00/2017 Ego(TST(049) Tensile Adhesion 133370.0Al2 N/26/2011 ERD ITST 6049) TAS 103 PLYG-SC13035.00.17 10/31/2017 ERD ITST 6149) MTM D1970 P37300.10.11 10/19/2011 FM ITST UNIT) Wintl Uplift 3W4091 01/12/2000 ERD CM(N9I TM 103 P40390.08.12-1 OW06/2012 KC-ES(WL VON) IBCCpmpllane, ER-107 W01/2019 ERDITST6N9) Tensile Adhesion P40391.08.12-2 08/07/2012 M-0(CUP 1592) HVN2cwnpiiance NOA 17-C614.22 07/06/2017 ERD(TST6(YVU Tensile Adhesion C41420.00.12-3 09/11/2012 Mn ITST 2508) ASTM M798 JX20117A N/01/2006 ERD ITST role) wheat Uplift P39690.03.13 03/04/2013 NEMO(TST6(49) ASTM D2970 4-0LYG-IOUN.o3.18 03/29/20M £RDDSTEN9) WM D197D P45370.04.13 N/26j2M3 NEMG tlST 6019) Wind Uplift 41-PLY&IM12,01.19 01f13/2019 EHD(TSTEor9) Wind Uplift P1738.02.07hR2 N/29/2013 NEMO(TST6N9) ASTM D610 44PLYG-18-002.01.1&A 01/24/2019 Ego DST 6649) Wind Uplift 11757.N.014-R1 01/30/2013 NEMG ITST spite) ASRd D= 45-PLYG-1&00205.1 05/10/2019 ERD DST Ti(Y19) ASTM D6I61 P37590.03.13-3A 05/W/2013 NEMO ITST Gore) TAS 103 45-PLYG-10-004.10.1 10108/2o19 ERD ITST Iior9) ASTM D009 P37590.03.1&1-RI 06/26/2013 NEMO rW Oil TAS 103 45-PLYG-104RN.10.19-1 10/08/3019 ERD MT W% Workuoit P41630.0H.13 mJWJ2ou NEMo iTST 6069) TA5103 95-PLYG-1H1pG.10.19-1 10/m/2019 ERD(TST 6or9) AST1.11,1601 P45940.09.13 n9/N/2U23 NEMO(TS'T6019) TA5103 4p PLYG-1955UDo01.A 10/10/2019 Ego(TST(OVU Wind Uplift P11751.05.03A3 11/26/2013 PRO LTSr 5878) Tensile Adhesion PRID3111 N/N/2001 END Gore) Wind UpIR P11781.11.o3-Rl 21/26/20B PRO UST 5878) TA5103 PUS4-0111-0241 07/14/3003 ERD UST 6049) 30/90physirals P45270MA4 05/12/2014 PRO(W 5878) TAS 303 14.15A{O35,02-01 W/29/2006 ERD MT 60491 Tensile adhexlon 6010.W.10.5 091,0812(114 Pse M SRI% TAS103 PUS4-0SS02-02 1211011007 ERDfrST61U19) Temikadhesion 6020.09.14£ (9/08/2014 PRI OST 5878) ASTM D6222 1U51,461-02-02 01/20/2008 EBD(MG0,u)) Tensile adhesion P46520.10.34 10/03/2014 PRI(TST 5979) ASTM D61M PUSH488-02-01 0/29/20M ERDDST60i MW D1970/D4798 N3290.30.14 10/17/2014 Poryglms USA P/LAficavit MulnNide Cross Ltg 03/01/20011 NEMG RTC,I.M. Evaluation Report P12 W.02.09-R25 2difkate o/AUMp/un6on R32455 6-MOTION(2017)fIlC NON.HVK EVALUATION FL5259-1129 isch" ew Roof Urkerkymenro:(954)233-1230 Revision 25:10/14/2019 page 2 of 16 ONEM01i Eo1 yt Enminttlon Rehrerste Date safts, Egaminetki Aghlorn[e Date Ego(TST 6049) TM He PLVG-SC)550.03.15 03/24/2015 PolyBlass UM Materials AXldamt Polystick Compound 09/la/2011 UL(DUM62S) duality Control Service Confirmation 09/13/2018 4. PROWCTDESUnPnci Product Specification Plant(s) Description 4.1 Elastobase ASTM D6163 FL Fiberglass-reinforced,SBS modified bitumen base sheet 4.2 Elastobase P ASTM D6164 FL Polyester-reinforced,SBS modified bitumen base sheet 4.3 Elastoflex G TU M-D 13-004 PA Polyester-reinforced,modified bitumen tile underlayment FRSA/TRI April 2012 composed of a sand-surfaced SBS modified bitumen back- side and granule-surfaced APP modified bitumen top-side 4.4 Elastoflex S6 G ASTM 06164 FL Polyester-reinforced,SBS modified bitumen cap sheet FRSA/TRI April 2012 4.5 Elastoflex S6 G FR ASTM D6164 FL Polyester-reinforced,SBS modified bitumen cap sheet FRSA/TRI April 2012 4.6 Mule-Hide SA-APP Cap Sheet ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet FRSA/TRI April 2012 4.7 HydraGuard Dual Pro ASTM D1970 FL Nominal 60-mil thick dual-layer rubberized asphalt waterproofing membrane,fiberglass reinforced,with a polyester fabric surface 4.8 HydraGuard Tile Pro ASTM D1970 FL Nominal 60-mil thick dual-layer rubberized asphalt TAS 103 waterproofing membrane,fiberglass reinforced,with a FRSA/TRI April 2012 polyester fabric surface 4.9 Mule-Hide SA-APP Cap Sheet ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet (FR) FRSA/TRI April 2012 4.10 Polyflex G ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet for FRSA/TRI April 2012 use as an alternate to Heat Applied"Cap Sheet"in the 'Two Ply System"from FRSA/TRI April 2012(04-12) beneath mechanically fastened or adhered tile roof systems 4.11 Polyflex G FR ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet for FRSA/TRI April 2012 use as an alternate to Heat Applied"Cap Sheet'in the "Two Ply System"from FRSA/TRI April 2012(04-12) beneath mechanically fastened tile roof systems 4.12 Polyflex SA P ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet FRSA/TRI April 2012 4.13 Polyflex SA P FR ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet FRSA/TRI April 2012 4.14 Polyglass Base ASTM D6509 FL Fiberglass-reinforced,APP modified bitumen base sheet 4.15 Polyglass G2 Base Sheet ASTM D4601 AL Fiberglass-reinforced,asphaltic base sheet 4.16 Polystick lR-Xe ASTM D1970 FL,PA Nominal 60-mil thick rubberized asphalt waterproofing membrane,glass fiber reinforced,with an aggregate surface 4.17 Polystick NITS Plus TAS 103 FL,PA,TX Nominal 60-mil thick rubberized asphalt waterproofing FRSA/TRI April 2012 membrane,glass fiber reinforced,surfaced with polyolefinic film surface NEMO ETC,LLC. Evaluation Report P32060.02.09-1125 Cemffl.eojAurawliurlene32455 6-EDITION(2017)HIC NON-HVHZ EVALUATION FM59-1129 PPlygleu Roof UndedaymeMs;(954)233-1230 Revision 25:10/14/2019 Page 3 of 16 4. PRODUCT DESCRIPTION: ONEMOletc. Product Specification Plant(s) Description 4.18 Polystick MU-X ASTM D1970 FL,NV,PA Nominal 54-mi1 thick dual-layer rubberized asphalt (See Section 5.8) waterproofing membrane,fiberglass reinforced,with a polypropylene film surface 4.19 Polystick TU Max ASTMD3970 FL,PA,TX Nominal 60-mil thick rubberized asphalt waterproofing TAS 103 membrane with a 190 g/m2 polyester fabric surface FRSA/TRI April 2012 4.20 Polystick TUP TAS 103 TX Nominal 130-mil thick rubberized asphalt waterproofing FRSA/TRI April 2012 membrane,glass-fiber/polyester reinforced,with a granular surface 4.21 Polystick TU Plus ASTM D1970 F4 PA Nominal 80-mil thick rubberized asphalt waterproofing TAS 103 membrane,glass fiber reinforced,with a polyester fabric FRSA/TRI April 2012 surface S. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMO I etc.nor Robert Nieminen,P.E.are,in anyway,the Designer of Record for any Project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed,a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: TABLE I: ROOF covmo TMN9 Wood shakes thadulaymeat Asphalt Shlngles NaPOn Tile Faai rile Metal aShingles slate Elasmbase Yes Yes Yes Yes Yes Yes aaaeSMttln 3ply Mtem (Base Saeetln2-plyry ; ElastobaseP Yes yes YM Yes Yes Yes Box SMetinxRMMteml (BneSneetln x-NYMnm) PGIYgIa55 Base No Yes Yes No No No (sau5aeetln2Plymtzm) (Box shSatinz gvmU+nl Polyglass G2 gaze No Yes Yes No No No (BaeslxoInxprymum) (aasemexlnz-Wmtem) ElartogexGTU Yes Yes Yes (See 5.5.1) No Yes Yes Elastogex SBG Yes Yes Yes (See 5.5.1) No Yes Yes Elastolle,515 G AR Yes Yes No No Yes Yes HydraGuard Dual Pro Yes No No Yes Yes Yes HydraGuard Tile Pro Yes Yes Yes (See 5.5.1) Yes Yes Yes Mule-Hide M-APPCap Yes Yes Yes (See 5.5.1) No Yes Yes Sheet Mule-Hide M-APPCap Yes Yes Yes (See 5.5.1) No Yes Yes She&(FR) POlyIMaG Yes Yes Yes (See 5.5.1) No Yes Yes Polyffex G Fit Yes Yes No No I Yes Yes P.K.SAP Yes Yes Yes Isee5.5.31 No Yes Yes Polyflex SA P FIR Yes Yes yes (See 5.5.11 Na Yes Yes Polystick lR-Xe Yes No No No Yes Yes NEMO ETc,LM. Evaluation Report P12060.0Z.09-1125 Cx.fi..fauMcrizUWa#U2a55 fi-EDITION(2017)FBC NOKNVNZ EVALUATION F1.5259AM Polyglass Roof UMedayments,(954)23 MD RevlSlon 25:10/14/2019 Page 4 of 16 ONEIV10jetc. TABLE I: ROOF COVER OPTIONS Wood Shaiws Undadryment Asphak9hlnrdes hag-0n l0e Foam-Dom Mewl &Shingles Slate Polystick MTS Plus Yes Ves No I Yes I Yes I Yes PalysHck MU-% Yes No No Yes Yes Yez PoIysUck TU Max No Yes Yes (See5.5.1) Yes No Ns Polystick TUP No Yes Yes )See 5.5.11 No No No Polystick TU Plus Yes Yes as (see 5.5.1) Yes Yes Yes 5.5.2 "Foam-On Tile"is limited to Use of the following Approved tile adhesives/underlayment combinations. TABLE 1A:Auu umu THE ADHENVE/UNDERIAYMENT COMBINATONSS Florida Produtt Adhesive Approval Undedayments DAP Foam Touch Seal StormBond Roof Tile Adhesive FL14506 Polystick TU Max or Polystick TU Plus Dow Tilellonl' FL22525 HydraGuard Tile Pro,Polyflex SA P,Polystick TU Max,Polystick TU P or Polystick TU Plus Elastoflex G TU,Elastoflex S6 G,HydraGuard Tile Pro,Mule-Hide SA-APP ICP Adhesives Polyset°AH-160 FL6332 Cap Sheet,Mule-Hide SA-APP Cap Sheet(FRI,Polyflex G,Polyflex SA P, Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus Elastoflex 56 G,HydraGuard Tile Pro,MUIe-Hide SA-APP Cap Sheet,Mule- ICP Adhesives Polyset•RTA-1 11211 Hide SA-APP Cap Sheet(FRI,Polyflex G,Polyflex SA P,Polyflex SA P FR, Polystick TU Max,Polystick TU P or Polystick TU Plus 5.6 Allowable Substrates: TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERIAYMFNTS Undedayment Application Substates(designedto meetwind loads for prp)ect) Type Primer Material(s) HydmGuard Dual Pro, Fadhering Deck/ (Optional)ASTM D41 plywood,OSB,Southern Yellow Pine or Huber HydraGuard Tile Pro, sheathing Engineered Woods-ZIP System"Panels PolysUck(all variations), ASTM D41 s[mttual concrete Mule-Hide SA-APP Cap ASTM C1289 Type 11 Class l polyisocyanuate,ASTM Sheet,Mule-Hide SA-APP Insulation (Optional)A5TM D41 C1289 TypeVorWB-3000 ROCK cypsu -Fibermoof BoarensDeck Cap Sheet(FR),Polyflex PFlme or SECUROCK Gypsum-Fiber Roof Boartl SA P or Polyflex SA P FRBase ASTM D226 felt,Elastobase,Elastobase P or Mule-Hide Sheet N/A Nail Base Deck ASTM D41 structural concrete Elastoflex G TU,Elastoflex hot asphalt Insulation (Optional)ASTM D41 DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Sfi G or Elastoflex 56 G FR Base N/A ASTM D226 felt,Elastobase,Elastobase P,Mule-Hide Nail Sheet Base or Polyglass G2 Base Deck ASTM D41 structural concrete Polyflex G or Polyflex G FR torch- Insulation (Optional)ASTM D41 DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board applied ease Elastobase,Elastobase P,Mule-Hide Nail Base,Polyglass Sheet N/A G2 Base or Polyglass Base 'Refer to Tile Manufacturers or Adhesive Manufactureh Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC,LLE. Evaluation Report P32ow.02.09-RZ5 Cxdflmtee)Hxho,&..n aa455 6'EDITION(2017)FBC NON.HVHZ EVALUATION FUS259-1139 Polydass Roof Underlayments;(am)2a9-1230 11 v161on 25:10/14/2019 Page 5 of 16 ONEMIDIeft. 5.6.1 Wind Resistance for Underlayment Syste Foam-On Tile Applications: The following wind uplift limitations apply to underlayment systems that are not prescriptively addressed in FRSA/TRI April 2012(04-12) and are used in foarni or mortar-set tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads and reflects the ultimate passing pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied).Refer to FRSA/TRI April 2012(04-12),Appendix A,Table lA or FBC 1609 for determination of design wind loads. #1 Maximum Design Pressure=-52.5 nsf: Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Autharty Having Jurisdiction. Joints: Min.flinch wide strips of Elastoflex SA-V over all OSB joints Base Ply: Potystick MTS Plus,self-adhered. Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or PolysdckTU Plus,self-adhered. #2 Maximum Design Pressure=-90 aid. Deck: Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: None Base Pry: (Optional)Polystick NITS Plus,self-adhered. Underlayment Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. #3 Maximum Design Pressure=-975 osf- Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PGIOO or ASTM D41 Base Ply: (Optional)Polystick NITS Plus,self-adhered. Underlayment Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,PDlystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered and back-nailed within the selvedge-edge side laps using 12 V.x 13t"ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c. #4 Maximum Design Pressure=-105 ad, Deck: Min.15/32-inch plywood to meet Project requirements to satisfaction of Authority Having Jurisdiction. Primer: WB-30M Base Ply: (Optional)Polystick WITS Plus,self-adhered. Underlayment Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Potystick TU P or Polystick TU Plus,self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x Ur ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c. #5 Maximum Design Pressure=.135 osf: Deck: MIn.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional)PG100 or ASTM D41 Base Ply: (Optional)Polystick MTS Plus,self adhered. Joints: Min.4-Inch wide strips of Elastoflex SA-V over all plywood joints. Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polyrtick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. #6 Maximum Design Pressure=.315 DO: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Base Ply: fOptional)Polystick MTS Plus,self-adhered. Underlayment:HydraGuard Tile Pro, Mule-Hide SA-APP Cap Sheet, Mule-Hide 5A-APP Cap Sheet IFR), Polyflex SA P, Polyflex SA P FR, Potystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. #7 Maximum Design Pressure=-622 5 osf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PGIOO or ASTM D41 Underlayment Elastoflex G TU or Elastoflex 56 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. NEMO ETC,U.C. Evaluation Report P12060.02.09-R25 CeAdIwoofAutlromadv#32455 6-EDITION(2017)FBC NON.HVHZ EVALUATION FL5259-1129 Painless Roof UrMerlayments;(9541233-IM Revision 25:10/14/2019 Page 6 of 16 NNEMOletc. #8 Maximum Design Pressure=.300 psfg: Deck: Min.15/32-Inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 Be.x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: &inch D.c.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional)Polystick MIS Plus,self-adhered. Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. #9 Maximum Design Pressure=-37 5 We: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 Be.x 1.25-Inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c.at the 3-inch wide side laps and&inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional)Polystick NITS Plus,self-adhered. UnderlaymenT Mule-Hide SA-APP Cap Sheet,Mule-Hide 5A-APP Cap Sheet(Fit),Polyflex SA P,Polyflex SA P Fit,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. #10 Maximum Design Pressure=-37.5 Rsfa: Deck: Min.19/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One(1)or two(2)layers ASTM D226,Type 11 felt Fasteners: 11 Be.x 1.25-inch long x 1-Inch head diameter round metal cap nails Spacing: &inch o.c.at the 3-inch wide side laps and 12-inch o.c.at Two(2)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt. #IS Maximum Design Pressure=-45 psf=: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One(1)layer ASTM D226,Type 11 felt Fasteners: 11ga.x1.25-inch x3/8-inch head diameter annular ring shank roofing nails at 1-5/&inch diametertincaps Spacing: 4-inch o.c.at the 2-inch wide side laps and 4-inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional;for use with self-adhering underlayment only)Polystick MTS Plus,self-adhered. Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(Fit),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered or Elastoflex G TU,applied in full mopping of hot asphalt. #12 Maximum Design Pressure--0 Psf-: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Two(2)layers A51M D226,Type II felt Fasteners: 11 Be.x 1.25-inch long x 3/8-Inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 9-inch O.C.at the 2-inch wide side laps and flinch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional;for use with self-adhering underlayment only)Polystick NITS Plus, elf-adhered, Underlayment:Mule-Hide M-APP Cap Sheet,Mule-Hide SA-APP tap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered or Elastoflex G TU or Elastoflex S6 G,applied In full mopping of hot asphalt. #13 Maximum Design Pressure=-45 ad: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex NAM Cap Fasteners Spacing: 9-inch o.c.at the 2-inch wide side laps and 18-inch o.c.at two(2)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #14 Maximum Design Pressure=-45.0 rtsf: Deck: APA rated,7/16 CAT,DAIS in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elartobase or Muls-Hide Nall Base(poly-film top surface) Fasteners: 12 ga.annular ring shank nails with 1-5/V diameter tin caps Spacing: &inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underlayment Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. NEMO ETC,I.I.C. Evaluation Report P12060.02.09-RZ5 6,ngkckaJAVM.fiu, np32ASS 6-EDITION(2017)FfiC NON.HVHZ EVALUATION FL5259-R29 PoWass Roal Undarlayments;(954)233-1230 Revision 25:10/14/2019 Page 7 of 16 ®NEMOIetc. #15 Maximum Design Pressure=-950 sf: Deck: APA rated,7/16 CAT,0.418 In.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sand top surface) Fasteners: 12 ga.annular ring shank nails with 1-5/8"diameter tin caps Spacing: &mch o.c.at the 3-inch wide side laps andGlnch o.c.at four(4)equally spaced staggered center rows. Underlayment Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt. 416 Maximum Design Pressure=-45.0 osf: Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSS sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass ease Fasteners: 12 ga.annular ring shank nails with 1-5/8"diameter tin caps Spacing: &inch o.c.at the 3-inch wide side laps and 6-Inch o.c.at four(4)equally spaced staggered center rows. Underlayment:Polyflex G,torch-applied. #17 Maximum Design Pressure=-52 5 osf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MARX Cap Fasteners Spacing: 9-Inch o.c.at the 2-Inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #18 Maximum Design Pressure=-52 5 osf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nall Base(poly-film top surface) Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c.at the 3-Inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Base Ply: (Optional)Polystick NITS Plus,self-adhered. Underlayment Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TV Plus,self-adhered. #19 Maximum Design Pressure=-52 5 osf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet Elastobase(sanded top surface for hat-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Slmplex Original Cap Nails Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Underlayment Elastoflex G TV or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #20 Maximum Design Pressure=.60 f: Deck: Min.19/32-inch Plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 8-inch o.c.at the flinch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows. Underlayment Elastoflex G TV or Elastoflex 56 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #21 Maximum Design Pressure=-60 osf: Deck: Min.19/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or arch-applied cap or poly-film surface for torch-applied cap) Fasteners: OMG#12 Standard Roofgrip with OMG Flat Bottom Metal Plates spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch art.at two(2)equally spaced staggered center rows. Underlayment Elastoflex G TV or Elastoflex 56 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. REMO mc,u c. Evaluation Report 1`12060.0209-R25 Cemgw2o/A,fta-fim#32455 6-EDITION(2017)FBC NON-HVH2 EVALUATION 115254a29 PoIndass Roof Undedayments;(9511)233.1230 Revision 25:10/14/2019 Page 8 of 16 NNEM01letc. #22 Maximum Design Pressure=.600 osf: Deck: APA rated,7/16 CAT,OA38 in.,Exposure 1,OSS sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: Simplex MANY Cap Fasteners Spacing: &Inch o.c.at the 3-Inch wide side laps and&inch o.c.at three(3)equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. #23 Maximum Design Press =-600 oaf: Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sand top surface) Fasteners: Simplex MAXX Cap Fasteners Spacing: B-inch o.c.at the 3-Inch wide side laps and 8-Inch o.c.at three(3)equally spaced staggered center rows. Underlayment Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt. #24 Maximum Design Pressure=-60 0 oaf: Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: Simplex MAXX Cap Fasteners Spacing: 8-inch o.c,at the 3-Inch wide side laps and 8-Inch o.c.at three(3)equally spaced staggered center rows. Underlayment: Polvflex G,torch-applied. #25 Maximum Design Pressure=-67 5 osf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass Base(requires use of torch-applied underfayment) Fasteners: 12 ga.x 1.2S-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 8-inch o.c.at the 4-inch wide side laps and 8-inch o.c.at four(4)equally spaced staggered center rows. Underlayment Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or torch-applied or Polyflex G,torch-applied. #26 Maximum Design Pressure=-67.5 osf: Deck: APA rated,19/32 CAT,0.578 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet Elastobase or Mule-Hide Nall Base(poly-film top surface) Fasteners: TRUFAST Versa-Fart Fasteners&Plates with two(2)screws per plate installed 180°Into the holes of the plate,parallel to the width direction of the sheet. Spacing: 12-Inch o.c.at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Primer (Optional)PG3G0 or ASTM D41 primer applied to stress plates. Base Ply; (Optional)Polystick MTS Plus,self-adhered. Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self adhered. #27 Maximum Design Pressure=-67.5 osf: Deck: APA rated,19/32 CAT,0.578 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sand top surface) Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)strews per plate installed 1800 into the holes of the plate,parallel to the width direction of the sheet. Spacing: 12-inch o.c.at the 4-Inch wide side laps and 12-Inch o.c.at two(2)equally spaced staggered center rows. Underlayment Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt. MEMO ET[,Lm Evaluation Report P12060.02.09-R25 .nVf.teofMd oio.Ubn#32455 I EDITION(2017)FBC NON-HVHZ EVALUATION FL5259.029 Polyglass Roof Underlaymems;(9S4)233-1230 Revision 25;10/14/2019 Page 9 of 16 MEMO I etc. #28 Maximum Design Pressure=-675 psf: Deck: APA rated,19/32 CAT,0.578in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180'into the holes of the plate,parallel to the width direction of the sheet. Spacing: 12-inch o.c.at the 4-Inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Underlayment:Polyflex G,torch-applied. #29 Maximum Design Pressure=-75 psf: Deck: MIn.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass Base(requires use of torch-applied underloyment) Fasteners: Dekfast#14 with Dekfast Hex plates,OMG#14 HD with OMG 3"Galvalume Steel Plates,OMG Roofgrip#14 with OMG Flat Bottom Plates(ACcgTrac),Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners Spacing: 10-inch o.c.at the 4-inch wide side laps and 10-inch o.c.at three(3)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex 56 G,applied in full mopping of hot asphalt or torch-applied or Polyflex G,torch-applied. #30 Maximum Design Pressure=-90 psf: Deck: MIn.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: &inch O.C.at the 2-inch wide side laps and Finch o.c.at Me(2)equally spaced staggered cancer rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt Or Polyflex G,torch-applied. #31 Maximum Design Pressure=-90 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cep or poly-film surface for torch-applied cap) Fasteners: OMG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: Cinch o.c.at the 4-Inch wide side laps antl&Inch o.c.at three(3)equally spaced Staggered center rows. Underlayment:Elastoflex G TU or Elastofiex 56 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #32 Maximum Design Pressure=-90 psf: Deck: MIn.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction, Base Sheet: Elastobase(sanded top surface) Fasteners: Trufast#12 OF or Trufast#14 HD with Trufast3"Metal Insulation Plates Spacing: 6-Inch o.c.at the 4-mch wide side laps and&Inch o.c.at three(3)equally spaced Staggered center news. Underlayment:Elastoflex G TU or Flastoflex S6 G,applied in full mopping of hat asphalt. #33 Maximum Design Pressure=-90 psf: Deck: MIn.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass Base(requires use of torch-applied underlayment) Fasteners: Del fast#14 with Dekfast Hex plates,OMG#14 HD with OMG 3"Galvalume Steel Plates,OMG Roofgrip#14 with OMG Flat Bottom Plates(AccuTrec),Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners Spacing: 9-inch O.C.at the 4-inch wide side laps and 9-inch o.c.at four(4)equally spaced staggered center rows. Underlayment.Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or torch-applied or Polyflex G,torch-applied. #34 Maximum Design Press =-900 psf: Deck: APA rated,7/16 CAT,0.418 In.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-H ide Nail Base(poly-fllm top surface) Fasteners: TRU FAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180'into the holes of the plate,parallel to the width-direction of the sheet Spacing: 3inch o.c.at the 2-Inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Primer: P6100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional)Polystick NITS Plus,self-adhered. Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TO P or Polystick TU Plus,self-adhered. NEMO UC,I.I.C. Evaluation RCpVrt P12060.02.09-K5 Certplrore a7AuMahmwn 012455 6n EDITION(2017)FBC NON-NVHZ EVALUATION F15259.829 PoWass Roof underlayments;(9541233-1230 Revision 25:10114/2019 Page 10 of 16 ®NEMO J etc. #35 Maximum Design Pressure=-90.0 osf: Deck: APA rated,7/16 CAT,0,418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sand top surface) Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180°into the holes of the plate,parallel to the width-direction of the sheet Spacing: 9-inch o.c.at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt. #36 Maximum Design Pressure=-900 osf: Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: TRU FAST Versa-Fart Fasteners&Plates with two(2)screws per plate installed 180°into the holes of the plate,parallel to the width-direction of the sheet Spacing: 9-inch O.C.at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Underlayment Polyflex G,torch-applied. #37 Maximum Design Pressure=-97.5 gsf: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-flm top surface) Fasteners: 11 ga.x 1.25-Inch x3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 4-Inch o.c.at the&inch wide side laps and 4-inch o.c.at four(4)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS Plus,seWadhered. Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. #38 Maximum Design Pressure=-97.5 osf: Deck: APA rated,19/32 CAT,0.579 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction, Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Primer: PG300 or ASTM D41 primer applied to stress plates. Base Ply: (Optional)Polystick NITS Plus,self-adhered. Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. #39 Maximum Design Pressure=-975 osf: Deck: APA rated,19/32 CAT,0.578 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sand top surface) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt. #40 Maximum Design Pressure=-97 5 osf: Deck: APA rated,19/32 CAT,0,578 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Underlayment:Polyflex G,torch-applied. #41 Maximum Design Pressure=-105 osf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied up or poly-film surface for torch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c.at the 2-Inch wide side laps and 6-Inch o.c.at three(3)equally spaced staggered center rows. Underlayment Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. MEMO ETC,LLG Evalaation Report P120TA.02.09-R25 CeAiftwe)Auftro,abn#32455 0 EDITION(2017)FBC NON.HVHZ EVALUATION FUu59-R29 Poyglass go&un4adayments,(9s H Z33-1330 Revision 25:10/14/2019 Page 11 of 16 ONEMO]etc. #42 Maximum Design Pressure=-105 0 f: Deck: APA rated,7/16 CAT,0.418 In.,Exposure 1,OSB sheathing to meet project requirementstosatisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: TRUFAST Versa-Fart Fasteners&Plates with two(2)screws per plate installed 180'into the holes of the plate,parallel to the width-direction of the sheet Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-Inch o.c.at three(3)equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional)Polystick MIS Plus,self-adhered. Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Shell(FR),Polyflex SA P,Polyflex SA P FR,PDlystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. #43 Maximum Design Pressure=-1050 f: Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing t0 meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheer Elastobase(sand top surface) Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180'into the holes of the plate,parallel to the width-direction of the sheet Spacing: 6-inch o.c.at the 44nch wide side laps and 6-Inch o.c.at three(3)equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastaflex S6 G,applied in full mopping of hot asphalt. #44 Maximum Design Pressure=-1050 Dsf Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing t0 meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: TRU FAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180'into the holes of the plate,parallel to the width-direction of the sheet Spacing: 6-inch o.c.at the flinch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows. Underlayment:Polyflex G,torch-applied. #45 Maximum Design Pressure=-112 5 DEC Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diametertin caps Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Primer: P61W or ASTM D41 primer at all tin-caps Base Ply: Polystick MTS Plus,self-adhered Underlayment Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. #46 Maximum Design Pressure=-120 Dsf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: OMG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6-inch o.c.at the nch wide side laps and&inch o.c.at five(5)equally spaced staggered center rows. Underlayment Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #47 Maximum Design Pressu re=-120 Dsf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase fronded top surface) Fasteners: Trufast#12 DP or Trofast#14 HD with Trufast 3"Metal Insulation Plates Spacing: 6-Inch o.c.at the 4-inch wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt. NEW ETC,I10. Evaluation Report P32060.02.09-US Gvg1xxe=fAu[1,mizvO..132. 6-EDMON(2011)fBE NON-HVHZ EVALUATION 1I5259-M9 PolWLss Roof Uralerlayments;(954)233-1Z30 Revision 25:10/14/2019 Page 12 of 16 ONEMOjetc. #48 Maximum Design Pressure=-1275 osf: Deck: APA rated,19/32 CAT,0,578 in.,Exposure 1,OSS sheathing to meet Project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: TRUFAST Versa-Fast Fasteners&Plates with one(1)screw per plate,In the center hole. Spacing: 9-Inch o.c.at the flinch wide side laps and 9-inch o.c.at four(4)equally spaced staggered center rows. Primer: PGSOO or ASTM D41 primer applied to stress plates. Base Ply: (Optional)Polystick NITS Plus,self-adhered. Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. #49 Maximum Design Pressure=-127.5 osf: Deck: APA rated,19/32 CAT,0.578 in.,Exposure 1,058 sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sand top surface) Fasteners: TRUFAST Versa-Fast Fasteners&Plates with one(1)screw per plate,in the center hole. Spacing: 9-inch o.c.at the 44nch wide side laps and 9-inch o.c.at four(4)equally spaced staggered center rows. Underlayment:Elastoflex G TU or ElasV flex 56 G,applied in full mopping of hot asphalt. #50 Maximum Design Pressure=-1275 osf: Deck: APA rated,19/32 CAT,0.579 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet Elastobase or Polyglass Base Fasteners: TRUFAST Versa-Fart Fasteners&Plates with one(1)screw Per plate,in the center hole. Spacing: 9-inch o.c.at the 4-inch wide side laps and 9-Inch o.c.at four(4)equally spaced staggered center rows. Underlayment Polyflex G,torch-applied. 5.6.1.1 All other direct-deck, adhered Polyglass Underlayment systems beneath foam-on tile systems carry a Maximum Design Pressure of-45 psf. 5.6.1.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012(04-12),Appendix A,Table IA. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDI, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations setforth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(January 2016)for Zone 2/3 enhancements. 5.7 Exposure Limitations: TABLE 3: ExPosuBB11MRATROM Underayment Maximum Exposure jdays) Elastoflex G TU,HydraGuard Dual Pro,HydraGuard Tile Pro,Polystick NITS Plus,Polystick TU INMax,Polystick TU P or Polystick TU Plus Polystick IR-Xe or Polystick MU-X 90 Elastobase,Elastobase P,Polyglass G2 Base or Polyglass Base 30 180 Elastoflex S6 G,Elastoflex 56 G FR,Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet (for adhesive-set tile) (FR),Polyflex G,Polyflex G FR,Polyflex SA P or Polyflex SA P FR UNLIMITED (for mechanically fastened roof prepared roof coven) 5.8 Polystick MU-%has been found through comparative testing to have a lesser coefficient of friction than ASTM D226 roofing felt in a dry condition,tested at standard laboratory conditions. Agreement between purchaser and seller, as set forth in Section 4.3,Note 1 of ASTM D1970-15,should be established as to slip resistance. NFMO eTG U.C. Evaluation Report 1`32060.02.09-R25 CemykareolAWhwosVonx32A55 6-EDITION(2017)FBC NON-NVNZ EVALUATION FL5253R29 Polyglass Roof Undedaymerrtn(9M)233-1230 Revision 25:10/1412D19 Page 13 of 16 ONEMOletc. 5.9 Tile Slippage Limitations(FRSA/TRI April 2012(04-1211, When loading roof tiles on the underlayment in direct-deck tile assemblies,the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TAaLE 2: TILE SLIPPAGE UWADONS FOR DIRER-DEOtt THE INSTAVATIONS Undedayment Tile Profile Staging Method Maximum Slope Flat 10-tile stack 7:12 ElastoflezG TU Lugged R-tile stack(6 over 2) 5:12 Elastoflez S6 G or 56 G FR Fiat or Lugged 54ile stack(4 over 2) 4,12 HydmGuard Tile Pro Flat or Lugged 6-tile stack(4 over 2) 7:12 Polyflex G or G FR Flat or Lugged 6-tile stack i4 over 2) 4:12 Polyflex SA P or SA P FR Flat or Lugged 6-tile stack(4 over 2) 4:12 Flat 6-dk stacks aver 21 5:12 Polystick MTS Plus Lugged 6-tilesWck(4 over 2) 4:12 Flat 6-tile stack(4 over 2)or 10-tile stack 7:12 Polystick TU Max Lugged 6-tile stack(4 over 2) ]:12 Lugged 10-tile stack 6:12 Flat 5-tile stack(4 over 2) 6:12 Polysuck TU P Lugged 6-tile stack(4 over 2) 4:12 Polystick TU Plus Flat or Lugged 6-111e stack i4 over 2) ]:12 Flat ar Lu ed 10-tile stack 6:12 6. INSTALLATION: 6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate(if applicable). 6.3 Elastobase,Elastobase P or MuIrHWe Nail Base: 6.3.1 Non-Tile Applications: Shall be installed in compliance with the codified requirements for ASTM D226,Type II underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed and Polyglass published requirements. Elastobase,Elastobase P or Mule-Hide Nail Base may be covered with a layer of Polystick,Polyflex SAP,Polyflex SA P FR,Mule- Hlde SA-APP Cap Sheet or SA-APP Cap Sheet(FR), self-adhered, Elastoflez G TU,Elastoflez S6 G or Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G FR,torch applied. Roof cover limitations are those are those associated with the top-layer underlayment,as set forth in Table 1. 6.3.2 Tile Applications: Elastobase, Elastobase P or Mule-Hide Nail Base are limited to use as a mechanically attached base sheet in the "Two Ply System"from FRSA/TRI April 2012(04-12). Reference is made to Table 1 and Section 5.6.1 herein,coupled with FRSA/TRI April 2012(04-12)Installation Manual. NEIVO ETC,LLC Evaluation Report P32050.02.09-R25 CeIifl to ofluIW ction 131455 6'EDITION(2o17)FBC NON-HVHZ EVALUATION 115259-R29 Polyglass Roof Underlayments;(954)233-1230 Revision 25:10/14/2019 Page 14 of 16 ONEMOjetc. 6.4 HydraGuard Dual Pro,HydraGuard Tile Pro,Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P, U Polyflex SA P FR,Polystick IR-Xe,Polystick MTS Plus,Polystick M -X,Poystick TU Max,Polystick TU P or Polystick TU Plus: 6.4.1 General: All seal-lap seams(selvage laps)must be firmly rolled with a in accordance with Polyglass requirements to ensure full contact and adhesion. For HydraGuard Dual Pro and HydraGuard Tile Pro, align the edge of the top sheet to the end of the glue pattern(the sheet will overlap the fabric). VlewofO idap Seamof HydraGuard Oual Pro and HydraGuardnie Pro 6.4.2 Non-Tile Aool'cat'ons, Shall be installed in compliance with the codified requirements for ASTM D1970(except Polystick TU P) underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed and Polyglass published requirements. 6.4.3 Tile Applications lexcludes HydraGuard Dual Pro,Polystick IR-X and P lmick MUA, Shall be installed in compliance with the requirements for Self-Adhered Membrane set forth in FRSA/TRI April 2012(04-12)and Polyglass published requirements. For mechanically fastened tile roofing over 2-ply system,consisting of Base Sheet and self-adhering top sheet(s), Base Sheet fastening shall be not less than FRSA/TRI April 2012(04-12),Table 1. For adhesive-set tile applications,refer to Section 5.6.1 herein. 6.4.4 Multi-Ply Underlayment Systems. Polystick NITS Plus followed by HydraGuard Tile Pro, Polyflex SA P, Polystick MTS Plus, Polystick MU.X, Polystick TU Max, Polystick TU P or Polystick TU Plus is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with the top-layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired. Polystick MTS Plus followed by HydraGuard Tile Pro, Polylex SA P, Polystick TU Max, Polystick TU P or Polystick TU Plus is allowable for use under adhesiveset tile systems. Limits of use are those associated with the top-layer material. This is not a requirement,but is allowable if a 2-ply underlayment system is desired. 6.5 Elastoflex G TU,Elast rflexS6 G or Elastoflex S6 G FR: 6.5.1 Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications: ✓ Elastoflex G TU is for use as an alternate to"Mineral Surface Roll Roofing"(ASTM D6380,Class M)in the"Single Ply System" from FRSA/TRI April 2012(04-12)beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet" In the"Two Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened or adhered tile roof systems. ✓ Elastoflex S6 G is for use as an alternate to"Mineral Surface Roll Roofing'(ASTM D6380,Class M)in the"Single Ply System" from FRSA/TRI April 2012(04-12)beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet" in the"Two Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened or adhered tile roof systems. ✓ Elastoflex S6 G FR is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened tile roof systems orthe Hot Asphalt applied"Cap Sheet"in the"Two Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened file roof systems. NENIO ETC,U.C. Enluaeon Report P32060.02.09-R25 Cert$a[e oJAut4Mzatlon#32455 6'"EDITION 12017I FBC NON.HVHZ EVALUATION FL52m R29 Polyglass Roof Undod,nients;(954)233-1230 Revision 25:10/14/2019 Page 15 of 16 ONEMOjetc. 6.5.2 For hot-asphalt-applications,Elastoflex G TU,Elastoflex56 G or Elastoflex S6 G FR shall be fully asphalt-applied to the substrates noted in Table 2. Side laps shall be minimum 3-inch and end-laps minimum 6-inch wide,off-set minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge. 6.6 Polyfex G or Pofyflex G FR: 6.6.1 Polyflex G or Polyflex G FR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications: ✓ Polyflex G is for use as an altemate to the Heat Applied"Cap Sheet'in the"Two Ply System"from FRSA/TRI April 2012(04- 12)beneath mechanically fastened or adhered tile roof systems(Refer to Table 2 for base sheet options). ✓ Polyflex G FR is for use as an alternate to the Heat Applied "Cap Sheet"in the"Two Ply System"from FRSA/TRI April 2012 (04-12)beneath mechanically fastened tile roof systems(Refer to Table 2 for base sheet options). 6.6.2 Polyflex G or Polyflex G FR shall be fully torch-applied to the substrates noted in Table 2. Side laps shall be minimum 3-inch and end-laps minimum 6-inch wide,off-set minimum 3 feet from course to course. Side and end laps shall be fully heat-welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap edge. 6.7 Tile Staging: 6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to Table 2 herein,and Polyglass published requirements for tile staging. 6.7.2 Battens and/or Counter-battens,as required by the tile manufacturer and FRSA/TRI April 2012(04-12)must be used on all roof slopes greater than 7:12. Precautions should be taken as needed,such as the use of battens or nail-boards,to prevent tile sliding and/or damage to the underlayment during the loading process. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANM Contact the noted CIA agency for information on product locations covered for F.A.C. 61G20-3 CIA requirements. Refer to Section 4 herein for product&production locations having met codified physical properties specifications. 9. QUALITY ASSURANCE ENTRY: UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com -END OF EVALUATION REPORT- NEMO ETC,LUC. Evaluation Report P32060.03.0 US C1nUko.gfA.hohmhuuk32. 0 EOITION(2017)FBC NON-HVHZ EVALUATION FL52591129 Palyglau Roof Ue4eHayments;(SIM)233-1230 Revision 25:10/14/2019 Page 16 of 16