Loading...
HomeMy WebLinkAboutNOA; Series SH-7700 (Flange Frame) Aluminium Single Hung WindowILU W LU Lu APPROVEDIr REVIEWED FOR N I ROVED AS CORRECTED p,[Py REVISE AND RESUBMIT El LiANCE M1 r,PPROVED ❑ ST. LUCIE CO DADE COUNTY `1NG IS ONLY FOR CONFORMANCE WITH THP nrrc% OL SECTION +.�ONP r r � eel Room 208 DEPARTMENT OF REGULATORY AItII3.�E�OI?k0�� , t � �� Hf 1;W h ONSIVE FOR DI1Vi Wp510iUP& F (786) 315 2599 BOARD AND CODE AAIYILNISTRATION�DW151-Q ,REL,I'ED AT THE SITE FOR NOTICE OF ACCEPTANM' "K + 'IINFORMATION PROCESSES OR TO THE MEA,gs- �r��r. -r��hOULDi7HLS F CONSTRUCTION AND FOR Lawson Industries, Inc. OF THE WORK OF ALL TRADES. ' 85011 NW 90 Street Medley, FL 33166 6 � —� -r�--- sY ARCHITECTURE S PLA'!!' G LI 4r A 7457 SCOT : =rd i ER DRIVE #107 DEERAELD EA , FL RID 33442 This NOA is being issued under the applicable rules and regulation r ng the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade lCounty Product Control Section (In Miami -Dade County) and/ or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to. revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity hurricane Zone. - DESCRIPTION: Series "SH-7700 (Flange Frame)" Aluminum Single Hung Window— L.M.L APPROVAL DOCUMEENT: Drawing No. L7700-0901, titled "Series-7700 Single Hung Flange Frame pact VmdoV', sheets 1 through 5 of 5, dated 05/27/09, with revision D dated 11/01/17, prepared by anufacturer, signed and sealed by Thomas J. Sotos, P.E., bearing the Miami -Dade County Product Control a, Revision stamp with the Notice of Acceptance number and expiration date by the Miami —Dade County o Product Control Section. n: IISSILE, INIPACT RATING: Large and Small Missile Impact Resistant f f T TiAMATIONT S: Insulated Glazing Options Types 6 and 7 are not approved to be installed above 30 feet in gd height without external protection device (shutters) I LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, series, and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been AUVERTISE1tUNT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be providers to the user by the manufacturer or its distributors and shall be available for inspection at the job site at .the request of the Building Official. This NOA revises NOA No. 16-' 003.01 and consists of this page 1 and evidence pages E-1 and E-2, as well as approval document mentioned above. The submitted documentation was reviewed by'Sifang Zhao, P.E. �` �= � :, NOA No. 17-121121 tWIAiil•r3ADE COUN'PY . 1., ; � �, � yx,�• � , �Expiration Date: December 27, 2fl2I Approval Date: February 01, 2018 page 1 Lawson Industries, Inc. NOTICE OF ACCEPTANCE: E ENCE SURIYIHTTED A. DRAWiti-CS 1. Manufacturer's die drawings and sections. (Submitted under NOA No. 09-ff706. 09) 2. Drawing No. L7700-0901, titled "Series-7700 Single Hung Flange Frame Impact Window", sheets 1 through 5 of 5, dated 05/27/09 with revision D dated 11/01/17, prepared by manufacturer, and signed and sealed by Thomas J. Sotos, P.E. B. TESTS 1. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with masked map drawings and installation diagram of an aluminum single hung window, prepared b� Hurricane .Engi Bening .& Testing, Inc., Test Reports No. I ETI- 09-�25MA and IIET 109-2530B, dated 03/02/09, signed and sealed by Candido F. Font, P.E. (Sit bmitted under IV O;4 No. 09-0706. 09) 2. Test reports on: 1) TUniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of an aluminum single hung window, prepared by Hurricane Engineering & Testing, Inc., all Test Reports No. HETI-08-2-003C, HETI-08-2004A, HE'I'I-08-2060A & B, HE, TI-08-2061A & B, CIE T I-08-2062A & B, HETI-08 2.063A .& .B, -IBC+ T1-08-2064A .& B, dated 03115/08, signed and sealed by Candido F. Font, P.E. (Submitted under• ArOA Nor. 08-0825.17) 3. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Resistance Test. per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411 3.2.1, TAS 202-94 .C. 1. Anchor verification-calculafions and structural analysis, comT4ying with FBC, prepared by Lawson Industries, Inc., dated 05/28/09, revised on 01/ 18/10, signed .and sealed. by Thomas d. Sotos, P.E. (Submitted un.der NOA NQ.11-0705.09) 2. Claziizg complies with ASTM EIS00-09 E-1 Sifang Zhao, P.E. .Product Control Examiner NOA No. 17-1212.21 Expiration Date: December27, 2021 ApprovalDat#.e: February 01,.2018 Lawson Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATION'S 1. Notice of Acceptance No. 17-0808.02 issued to Kuraray America, Inc. for their "SentryGlas® (Clear and White) Glass Interlayers" dated 12/28/17, expiring on 07/04/23. 2. Notice of Acceptance No. 16-11I7.01 issued to Kuraray America, Inc. for their "Trosifol® Ultraclear, Clear and Color PYB Interlayers" dated 01/19/17, expiring on 07/08/19. 3. Notice of Acceptance No.17-0712.05 issued to Eastman Chemical Company (NIA) for'their "Saflea Clear and Color Glass Interlayers" dated 09/07/17, expiring on 05/21/21. F. STATEMENTS I. Statement letter of conformance, complying with FBC-61 Edition, (2017), and of no financial interest, dated November 17, 2017, issued by manufacturer, signed and sealed by Thomas J. Sotos, P.E_ 2. Statement letter of no financial interest, dated 05/28/09, issued by manufacturer, signed and sealed by Thomas J. Sotos, P.E. (Submitted under NDA No.11-0705.09) 3. Laboratory compliance letter for all Test Reports No. BETI-09-2530A & B, issued by Hurricane Engineering & Testing, Inc., dated 03/02/09, signed and sealed by Candido F. Font, P.E. (Submitted under NOA No. 09-0706.09) 4. Laboratory compliance letter for Test Reports No. HETI-08-2003C, HETI-08- 2004A., RETI-08-2060A & B, H]ETI-08-2061A & B, HEETI-08-2062 A & B, HETI-08-2063A & B, HETI.08 2064A &B, issued by Hurricane Engineering & Testing, Inc., dated 03/15/08, signed and sealed by Candido F. Font, P.E. (Submitted under NOA No. 08-0825.17)- -. 5. Laboratory compliance letter for Test Reports No. FTL-2987 and. FTL-2986, issued by Fenestration Testing Laboratory, Inc., dated 04/03/01 and 03/27/01, signed and sealecl by Luis Antonio F guexedo; P.E. (Sobntztted under NOA No 01 ' 0444(.08) G OTI5` 1. Notice of Acceptance No.16-1003.01, issued to Lawson Industries, Inc. for their Series"SH-7700 (Flange Frame)" Aluminum Single Flung Window — L.M.I.", approved on 12/15/16 and expiring on 12/27/21. Wang Zhao, P.E. Product Control Examiner NOA No. 17-1212.21 Expiration Bate: December 27, 2021 Approval Dates February 01, 2018 E-2 45 53125• 53125• a aftCMDRS. WINDOW FLANGT. FRAME VI➢iM WINDOW FLAME FRAME VI➢iH INSTALLATION ANCHORS' WIN= FLANGE FRAM£ vipit T FRAME MEt FRAME A➢ �.1 INS TALLATION ANCHORS ca) 4 MAX. AT FRAME HEAD orbs cSEE MAXQC. iW t4mIH1E PER AT FRAM SD.LD MAs/�C, Q) cC) FaIIAnEJARaPER FsaisEE)SET.e4) - A 'I W1X 3n.C.� j C FF (C) FRAME J/NHS =E SHEET Fla) b• C 6•( N - {' 6' a-7-7� 6• ALL CGRNFAS ' IA _ D.LO. Width P1.L CORNEfTs � �_ = uQy* aV 3$s M)IEAE%T. 1fAIGBORVAEILS -___B nii Irei.1�.i -=�' (J FtO C6�Tryc �iR�T`{3�" 30 31 /IlIbF�' TiriG ppll _1:;i / •: 0 q D �o �IT9 � MAX.; ➢f.11fF.--' - ��. � li i __ oo -- IQ va• ? �I- n Ma'D.L.O. VA thAoVtid >= ci• u ag " .� " 4 tl 16" a; 48 1t tQ u 1 e AT n '�'.I. S 1 w';�-u I1 i MEETING ^ h I ii ny2w�Ir'I". j ii B II xo-{y i1 n.z °' b' IAffTET[NG F L'Hi' a�i 1 AT :cV > Zqq 2 g = �y li / •� t�,/T Y� uj TjRAILS V i' /' S 9 T/$• ____ •FBI p in r�ag2 �9 9 VMI A% HELDW I; f . ✓ 2 E Sri x lU yy 6 8 MEERNG X iE1'ING LRA�IL� /�j/ i� q' .-ce=,.e�j_ __ / u E%T. 6 IW. FALSE COL6t ALA C' WSILICONE ANDIARE w. VIKDDW BUCK WIDTH WINDOW DUCK WIDTH AVAILABLE AS OPTIONAL. 48" s 78" EQUAL LITE ELEVATION UN —EQUAL LITE RADIUS ELEVATION 0 INCLUDES UN -EQUAL UTZ AND RADIUS HEAD (LIMITED TO LOADS ON SHEET 4 OF 5) (LIMITED TO LOADS ON SHEET 4 OF 6) SERIES-7700 SINGLE HUNG General Notes: 1.) THIS WINDOW SYSTEM IS DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE (2014-5th EdLUOU & 2017-6th ECItion) INCLUDING INSTAlATHW ANCHORS. HIGH VELOCITY HURRICANE ZONE VELOCITY (HVHZ) AND ASTM 1300-09. w a MA%. AT FRAME MEAD THIS PRODUCT IS IMPACT RESISTANT. (SHUTTERS NOT REQUIRED) le) FRA�EMEP.E1.1=1 _ SHEETDo $.) WOOD BUCKS SHALL BE INSTALLED AND ANCHORED 50 THAT THE BUILDING RESISTS THE SUPERIMPOSED LOADS IN ACCORDANCE WITH THE REQUIREMENTS .CAL aT OF THE F.B.C. & TO BE REVIEWED BY BUILDING OFFICIAL b• CORNERS' 3.) ANCHORS SHOWN ABOVE ARE AS PER TEST UNITS. ANCHORS ON ALL WINDOW SIZES ARE NOT TO EXCEED THESE MAXIMUM SPACINGS ON CENTER (O.C.) AND AS TABULATED ON SHEET 4. -t—'"' 4.) ANCHOR CONDITIONS NOT DESCRIBED IN THESE DRAWING'S ARE. TO BE n 9 5/B• ENGINEERED ON A SITE SPECIFIC BASIS. UNDER SEPARATE APPROVAL AND S MAx. a➢Ov= TO BE REVIEWED BY BUILDING OFFICIAL.. �T 5.) WINDOWS ARE QUALIFIED FOR USE WITH SINGLE GLAZE LAMINATED GLASS TYPES TABULATED HEREIN (SEE SHEET #3). AND FOR USE WITH DOUBLE GLAZE LAMINATED INSULATED GLASS TYPES TABULATED HEREIN (SEE SHEET #3). 6.) SEE SHEET 3 FOR LOCK DETAILS & OPTIONS. 7.) SEE SHEET 4 FOR DESIGN PRESSURES'AND GLASS TYPES. �i EA 8.) FOR OPTIONAL FRAME INSTALLATION DETAILS SEE SHEET 3. 0.) EXT. & TNT. FALSE COLONIAL MUNTINS ARE OPTIONAL & AND ARE APPLIED W/ SDICONE S� 9 AX BELDV 10.) WOOD BUCKS IN CONTACT WITH CONCRETE MUST BE PRESSURE TREATED AND ANCHORED NECTINL RAILS ---c✓ (BY OTHERS). PRIOR TO WINDOW INSTALLATION. (SEE SHEET #2 FOR DETAIL & NOTES) I WOOD BUCKS TO BE ANCHORED IN COMPLIANCE WITH THE FBC CHAPTER 24, SECTION 11.3.3.3. "MAX. 11.) APPROVAL APPLIES TO SINGLE UNITS OR SIDE BY SIDE MULLED UNITS. 12.)'MULLING SINGLE HUNG WINDOWS WITH OTHER TYPES OF MIAMi—DARE COUNTY APPROVED WINDOWS USING A MIAMI—DADS COUNTY APPROVED MULLION IN BETWEEN ARE ACCEPTABLE EXT. 6 INT. FALSE COLONIAL HUNT INS ARE APPLIED v/ BUT THE LOWER DESIGN PRESSURE FROM THE WINDOWS OR MULLION APPROVAL WILL APPLY v/ SILICONE AND ARE TO THE ENTIRE MULLED SYSTEM. AVAILA➢LE AS OPTIONAL. 13.) SEE SHEET # 3 FOR MULLION/METAL ATTACHMENT DETAILS & OPTIONS. 14.) ALL METAL/STEEL IN CONTACT WITH ALUMINUM OR OTHER DISSiMIIAR MATERIALS TO BE PAINTED OR PLATED AND SHALL MEET THE FLORIDA BLDG. CODE, WINDOW FLAME FRANC WIDTH 13 3:a• -- -\— MAY- ILC. i WINDOW SUCK WIDTH :UNEQUAL LITE ELEVATION -'"(LIMITED-TO WADS ON SHEET 4 OF 5) � i L . q HRODUCT REVISED M cWnplping uRh dm Flanda DuddLn 1 - Atrtgtanx ND � ZI?.zI i�IpirntiDq Dive � 521�• - MimDi DDd¢ Lkod50t CoDaat WINDOW DUCK VIDTH - EQUAL LITE ] LEVA'ITON (LIMITED TO LOADS ON SHEET 4 OF 5).. J _ Q O o C] m _ 1 IAA o V L) R oitm _ Kl LE IT+ TL 4 V4 o U -� z a Ul o E!s (� m O 4 [11`7 o� 1/4' TAPCON W! 1 1/4' ALL VDOD BUCKS ENGINEERED SEPARATELY — MIN. EMBEDMENT INTO CONC. & f0 BE REVIEWED BY BLDG. OFFICIAL (TYPJ (SEE ELEVATION AT SHEET #I FOR MAX. FASTENER SPACING) P.T WDOD BUCK NOT BY LAWSON IND. MUST SUSTAIN IMPOSED LOADS --E11G1/ DISKIN O : EXTERIOR C O EXTERIOR GRADE - PERIMETER CAULI i SILICONE ADHESIVE i BEDDING COMPOUND LAMINATED GLASS 2a INTERIOR RAILS 16 EXT. GRADE CAULK Ila% O VFW . � 4: •. 4: •'d: d'e v n - EXT. O EXT. 414 S.M.S. W/ 1 1/4' NUN. EMBEDMENT INTO W1301L (SEE ELEVATION AT SHEET 51 FOR MAX, FASTENER SPACING) DE O Y1, S.S. W/ t 1/4' MIN. EMBEDMENT INTO WOI (SEE ELEVATION AT SHEE FM MAX, FASTENER SPAC GI CAA CAULK BY OR 2 BY GOD BUCK I' MAX. SHIM TYP L NATED GLASS ': .; .PT. WOOD BUCKS 24 <:: ADHESIVE COMPOUND INTERIOR 7 20 :. ' • 1/4' TAPCUN W/ 1 1/4' :o no m _ MIN. EMBEDMENT INTO C011C. (SEE ELEVATION AT SHEET Nl FOR MAX. FASTENER SPACING) N G e m 12 1 I/4' MIN. 'L z D - EMBEDMENT y w = m m 0. MIN. EDGE DISTANCE 0 ' 4' : c •.r. EXTERIOR PERWETEER�CAULKING —WINDOW FRAME WIDTH .A WINDOW INST t�T A rrp�.i t(QTES. 1. THE WINDDV FRAM'FLANGE TD BE BACK -BEDDED W/ AN EXT. GRADE CAULK THROUGHDUT-THE ENTIRE PERIMETER OF FLANGE BY WIN➢DW TNSTAILER <TYPJ �w 2. EXPOSED- THE WIW FRAHE 7O EXT _PERIMETER WINDOW BE *- BE SEALED W! AN,,APPRDVED EXTERIOR GRADE CAULK � BY DTHERS (TYPT • WEEN THE GAP BETWEEN THE WINDOVF FRAIIE AND THE BUCK OP I� MASONRY IS LESS THAN 1*;,-:SHM ARE NOT REQUIRM ` \ Z F N ANCiiORS NOZC , .., ANCHORS TO BE #12 SMS,0R WD, SCREWS INTO WOOD, OR I 1/4' TAPCONS nr'APPROVED:.CCNC. FASTENERS INTO CONC., b WITH A MINIMUM CIF 11A4 -PENETRATION INTO WOOD OR CONC. (REFER -if" LOAD -:TABLES AT SHEET 4 OF 5 FOR QUANTITIES REQQIREO)�' ._, R 5 Eq ;y z Q a K t7(OI)UCFEU3Vi$rD Ib. c) a Q:Jd ,�'i o F'D��Code with tlx FI—du mn�i,9 G;1,_y ni 0 t;''.� 6tCwutioa Ott, By o rn M t'4 Kama DadaYmdnmic. o! �e� �•�' f�<'0l a �� 8 24 71 -SILICONE OPTIOWi D01/ F.-H11S 039 TREMM-N➢BEREAD a TRENCO SPECTRUM 2 GbLD' GLAZENS DEPTH LUMATED CLASS COMPOSITION - TYPE 2 I386I DEED LAYD(ATH ➢EEC➢TPIION 1 ' ANN GLA S 1/d' ANNEAl.EO GLASS 1 Eaatnan Chenicnt cu F—tSm.ch is 2 4*W PLASTIC INTERLAYER _ _ ___ I -JF � 3 VO• ANNEALED GLASS o3(a' LAMINATED GLASS COMPOSITION - TYPE 3 if1DI CI.L93 WECBiP'II(LY DCCALL IAOD(ATE DEBClLIPTIO)i t UD' AvsALED QASE SENTRTGLAS by KuroraY pnerkR, InC. Y a090' FLASTIC INTERLAYER - - -� 3 I/V ANNEPLE➢ GLASS oaHr L UUNATED GLASS COMPOSITION - TYPE 4 RH11 07AHS DC9CIIII"11aN O=AU,GLA 1AIDNATB DSSCRIPI7 _ 2 0.096' PLASTIC 1NTEi3AYFR 3 1 us. ANNEALED LASS 1 Hu(r LAMINATED GLASS COMPOSITION - TYPE 5 ITEM IOASS 1)EELYi@AON ➢IIIAO. IAYINAi& DESCBO`RON 1 1/e' WAY-STRq/GNTERED GLASS TMSIFOL PVB by 2 mow PLASTIC IHRERLAYER K,.raray Anrrica, lac 3 1/8' HEAT-STRENGMTENED CiASS JJ it 20 'SIUCGNE OPTIONS', DOW CORNING 399 sEHB&S-MDIENEAD 0737 24 TRENCH ai'ECYRtM E D.GOD RAZING DEPTH INSULATED LAIIINATED GLASS COMPOSITION TYPE O rum GLASS DescimRICN I.Imnum ➢E➢LTiO'ITO I Va. tFAT-STRENGNTENED GLASS 2 GDW PLASTIC INTERLAYER ® L--���- TRMWOL PVD or 3 7/R• HEAT-STRENGHTEIE➢ GLASS = _ -.- _ = H R K.—Y A-1ce, Inc 4 V4' INSULATED AIR SPACE I 3 UE' ANNEALED GLASS INSULATED LAMINATED GLASS COMPOSITION TYPE 7 nVA WASS D1'SYBII+amti M11, DSl'AO' IAWNAa L 1 R' A"ALED GLASS S QMV PLASTIC OfTERLAYER o .V4- SAFLEX PVH by 3 VW ANNEALED GLASS =- _ _ — E--nan Chi kal Ca. 4 1I4' INSULATED AIR SPACE E I/0' ANNEALED GLASS "H�o• GLAZING DETAILS AND OPTIONS NOTE: WINDOPIS PATH GLASS TYPES "O & 7" INSTALLED ABOVE 301t IN THE HVHZ, THE I.G. IN THE EXTERIOR LITE SHALL BE TEMPERED TO COMPLY WITH THE SMALL MISSILE IMPACT RESISTANCE REQUIREMENTS (ABC-2017• Chapter 24 Section 241L.3.3,7). 414 S.N.S. WJ 1 MIN. EMBEDMENT INTO WOOD. (SEE ELEVATION AT SHEET I', FOR MAX, FASTENER SPACMG) ex ePINTERIOR INO VINWW FRAME AHGE HY MSTALLER EXTERIOR CAULKING GRADE PERNETER 'L WS NG NOT BY TO BEE ALPPIBED BY INDUSTRIES' OYPa STUCCO OVER METAL LATH NAILED TO EXIOUM GRADE PLYWOOD SHEATHING TO BE SPECIFIED BY ARCHITECT OR GC, (EXTERIDt FINISH BY OTHERS) NOT BY LAWSON INDUSTRIES, INC WOOD FRAME iNFFAI.T,ATIQN DE,TAlL ALUMINUM MULLION SEE MULLION APPROVALS MR 11 12 X 3/4' S.D.S. MULLION TYPE, SIZE AND MAX. FLAT HEAD, PHILLIPS, DESIGN PRESSURE UWTATIONS. (SEE ELEVATION AND (ALUM. 0.078- MIN. THICK) _ DP TABLES FOR QUANTITY AND FASTENER SPACING) NOTE: THE LOWER PRESSURES OF SL LE HUNG WINDOW OR IAULL SMALL GOVERN INTERIOR {{ 11 EXTERIOR /j EXTERIOR GRADE PERIMETER CAULKING FRAME MULLING DETAIL 26 6 l LD 25 t Lnj5 il LOCK (LATCH`- AND SWEEP) OPTIONS 1. BOTH EXTRUDED:`ALUMINUSta AND PLASTIC LIFT HANDLE LOCKS ARE "QUALi['iED'FOR-'USE ON ALL WINDOWS. 2. BOTH DIE CAST :AND'NYLON :CAM LOCKS ARE QUALIFIED FOR USE ON ALL WI-NDOWS. ' 3. TWO (2) LOCKS ARE° REQUIRED PER EACH VENT. --'NOTE::-THE LOWER PRESSURES OF SINGLE T�hjpK-.:�Ht1NG'Y/INQOY! 0`9 L:UL, SHALL GCVEERN HUH' 42�4,0.S. .�;;SEE;_ELEV:,-r0R SAAGNG o� i. ALL STEEL IN CONTACT WITH i M. TO BE PAINTED OR PLATED, 3 c 2. MEFAL STRUCTURES x A) STEEL.: Fy - 36 KSI MiN. (STEEL 16 GA. MHN. THICK - 0.046-) PEPoIAETc'-ii :_" WiNDGW FRAME B) ALUMINUM : 6065-75 MIN. t l 6 ci (ALUIL 0.078- MIN. THICK) SEALANT EXTERIOR.. _ ° PI(ODUCT i(EVI5LF� oswlGTayias aHdl Lje Ftoltaa ���crl�a; p+N�._.L. m� 7. !�} v., �, Building Code AECIpt2neeNal BwwaLMsiePr DESIGN LOAD CAPACITY (PSF) -VIEW WINDOWS W/3H VENTS WINDOW 1; Jamb Anchors + /- Pressures (psr) Glass Type 4 Glass Type 5 Glass Typo 6 WIDTH HEIGHT 19.125 50.625 8 60.0 80.0 80.0 26.5 50.625 60.0 8D.0 80.0 37 50.625 60.0 80.0 80.0 42 60.625 60.0 8D,0 80.0 48 50.626 60.0 80.0 80.0 53.125 50.625 60.0 80-0 1 80.0 19.126 59 6 60.0 80.0 80.0 26.5 59 6D.0 80.0 80.0 37 59 60.0 80.0 80.0 42 59 60.0 80.0 80.0 48 59 60.0 80.0 80.0 53.125 Be 60.0 80.0 80.0 19A25 63 6 60.0 80.0 80.0 26.5 63 60.0 80.0 1 80.0 37 63 60.0 80.0 i80.0 42 63 60.0 80.0 80.0 48 63 60.0 B0.0 80.0 53.125 63 60.0 80.0 80.0 19.125 74.25 8 60.0 80.0 80.0 26.5 74.25 60.0 80,0 80.0 37 74.25 60.0 80.0 80.0 42 74.25 60.0 80.0 80,0 19.125 78 a 60.0 80.0 80.0 26.5 78- 60.0 80.0 8010 37 78 60.0 B0.0 80.0 421 78 59.0 79.0 79.0 DESIGN LOAD CAPACITY (PSF) -VIEW WINDOWS Wf 4H VENTS WINDOW 0 Jamb Anchors + f - Pressures (psi) Glass Type 4 Glass Type 5 Glass Type 6 WIDTH HEIGHT 19.125 59 6 60.0 BOA 80.0 26.5 59 60.0 80.0 80.0 37 59 60.0 80,0 80.0 42 59 60.0 80.0 80.0 48 59 60.0 80.0 1 80.0 53.125 59 60.0 80.0 80.0 19.125 63 1 6 60.0 80.0 80.0 26.5 63 60.0 80.0 80,0 37 63 60.0 80.0 80.0 42 63 60.0 80.0 80.0 48 63 60.0 80.0 80.0 53.125 63 60.0 80.0 80.0 19.125 74.25 8 60.0 80.0 80.0 26.5 74.25 60.0 80.0 80.0 37 74.25 60.0 80.0 80.0 42 74.25 60.0 80.0 80.0 53.125 74.25 60.0 1 80.0 80.0 19.125 78 a 60.0 80.0 80.0 26.5 78 60.0 80.0 80.0 37 78 60.0 80.0 80.0 42 78 59.0 79.0 79.0 APPROVED CONFIGURATIONS UN -EQUAL LITE DESIGN LOAD C4PACTTY (PSF),=EQUAL.'LfIE;WINDOWS WINDOW Jamb Anchors (Ps0 Glass Type 2 Glass Type 3 GlassType 4 :.Glass Type 6 Glass Type 6 Glass Type 7 WIDTH HFJGHC 19.125 _ 26 4 60.0 80.0 60:0-;' "'+'" 80,0 80.0 80.0 26.5 26 _ 80.0 80.0 <-s60i0 ='rs-` . , , 80.0 80.0 80.0 37 26 80.0 80,0 60:0 80.0 80.0 80.0 42 26 80.0 $0.0 =60;D= ,,,= ? : . 8D.0 80,0 80A 48 26 80.0 80.0 80 0 80.0 80.0 80.D 53.125 26 80.0 80.0 R60[0. %;- - • . • 80.0 80.0 80.0 19.125 38,375 4 80.0 80.0 60=0 60.0 80.0 80.0 26.5 38.375 80.0 80.0 _60:D 80.0 80.0 80.0 37 38.375 80.0 60.0 fi0:0 .80,0 80.0 80.0 42 38.375 80,0 80.0 "60i0 80.0 80.0 80.0 48 36.375 60.0 80.0 80.0 60.0 80.0 53.125 38.375 80.0 80.0 60:0 80.0 80.0 80.0 19.125 50.625 6 80.0 80,0 600,;;;- :'..:_80.0 80.0 80.0 26.5 50.625 80.0 80.0 60.0 60,0 S0.0 $0.0 37 50.625 80.0 80.0 ?60:0 ,: '_ 8D.0 80.0 80.0 42 50.625 80.0 80.0 •fi0;0 - - 80.0 80.0 80.0 48 50.625 80.0 Mo 80:0 80.0 80.0 80,0 53.125 50.625 80.0. 80.0 GD O_ .., Wo 80.0 86-0 - 19.125 59 6 80.0 1 80.0 600 80.0 80.0 80.0 26.5 59 80.0 80.0 `60i0" -. 80,0 80.o 80.0 37 59 80.0 80.0 60;0 80.0 80.0 80.0 42 59 80.0 80.0 6D30 , 00.0 80.0 80.0 48 59 80.0 80.0 = - _ - - 80.0 53.125 59 80.0 80.0 80.0 ID.125 63 6 80,0 80.0 6D:0 80.0 80.D 80.0 28,5 63 _ 80.0 80.0 600_7; '80.0 37 ( 63 80.0. 80.0 -<600.5 = - 80.0 80.0 80.0 42 63 60.0 80.0 1J60:0" ,- 80.0 80.0 80.0 48 63 80.0 80.0 80.0 53.125 63 80.0 80.0 80.0 19.125 74.25 8 80.0 80.0 :6D:0; •- -,..,_.80.0 60.0 80.0 26.5 74.25 80.0 60.0 600 50.0 80.0 80.0 37 74.25 60.0 80.0 80,0 42 } 74.25 80.0 80.0 80.0 46 74.25 80.0 80.0 - _ ' 80.0 53.125 74.25 1 74.0 77.0 -- - - 80.0 19,125 78 6 80.0 80.0 :60:0 8D.0 80.0 80.0 26.5 78 80.0 80.0 60.0 80.0 80.0 80.0 37 78 80.0 80.0 840 42 78 79.0 79.0 79.0 48 78 71.0 71.0 71.0 FF !i�% I:d APPT?nvp. 1 (`nNRrr_rfPA PTf%MQ - rnrrAT_. T] �\� �r.�.riiJCT(�ViScD m Mmpiyipg n3dr Utc Florida Bui?den.5Cods . AcceptanxNu 'I-I21L•2q Eapimtian ➢a • y ldi:¢t(0o:!,r Yraduvt CoaL•al 0 0 � � I r y G� Gi Q 2 0 0 Y 0 w mna 0 a` e cr a 6j o c7 N 0 FRAME HEAD L-7701 O i .3I d 2.651-----I ( OfIG3-T3 ALVlaN04 ) FRAME SILL L-7702 FDCED MEETING RAIL L-7704 FRAME JAMB L-7 . FRAME TOP CORL I � I FRAME HEAD FR"F JAMS VENT INTERLOCK RAIL VENT BOTTOU RAIL VENT JAMB RAIL L-7706 L-7708 L-7707 O (aow-ra uuwxou) O ( 6063-m Awlmen ) O(d0a3-iA AMllmtpl[ ) —L375—�I al .062 1465 [Ft.) 7�. VENT SPRING LATCH GLAZING BEAD GLAZING BEAD GLAZING BEAD L-7539 L-7708 L-7711 L-4204 O ® 16 17 A62 (G047�fa ui1NJF'UU ! ( Goan-iG AwmttOM) (a0e9_ga Aw{1n�1N L013 .J91 j (i IIIu11► 115 .698 '1 '9b6 ( dwa-iB A uDniM ) \J FP.AME BOTTOM CORNER 3 �•� VENT TOE QQIjjVER 9 jg[(i AAtAB RAtl 1. OVENr HOTfOM RAI_ VENT BOTTOM CORNER FRAME & SASH CORNER DETAILS B1LL '0F MATM1ALS ITEM i9 PART # REQD. iESCIlIPTTON '..' REMARKS 1L L-7801 I FIN:FRAME"£IEAD 6063-T6 ALUMINUM 2 L-70OF 1 FIN,FRAME-,SILL 6063-T6 ALUMINUM 3 L-7803 2 F.1WFRANE ;JAMB 6063-T6 ALUMINUM 4 L-7704 1 FRAME.—ti ED^;MEETING RAIL 6063-T6 ALUMINUM 5 L-7705 1 VENT,MEETikG4IOP) RAIL 6063-T6 ALUMINUM 6 L-7706 1 VE0F_'BOTT(1M�_(LATCH) RAIL 6063-T6 ALUMINUM 7 L-7707 2 VEML'JAMB;:<SIDE) RAIL 6063-T6 ALUMINUM 8 L-7708 AS REQ'D GIAZING;D£AIIi;"3/8' > 6063-T5 ALUMINUM 9 FS-006 AS REQFR FRAME'=-ASS£MBL•Y:SCREWS #8 X 3/4' P.H. PHILLIPS 10 FS-040 AS REQII INSiALLATION''SCREWS 414 X 1 1/4' F.H./PHIL. 11 L-7531 JAS REQ'D DULB VINYL'WTS'P 1/4' DIA, BULB 0033 12 PWS-003 JAS REQ'D. FIN _SEQI::WEAATHERSTRIP 487'x.230' 13 PWS-005 AS REQ'D. FIN SEAL«WEATHERSTRIP .187'x.3501 14 PWS-009 AS REQ'D FIN,SEAL WEATHERSTRIP 187'x.310' 15 HC-024-1 2 SELF..=A13HESIVE`.PILE PAD 1/4' X 1 1/2' 16 L-7711 AS REWB GLAZING BEAD/i:INSULATE➢ 6063-TS ALUMINUM 17 L-4204 AS REQ'D GLAZING;BEAD.-.'RADIUS 6063-T5 ALUMINUM 18 L-7723 I SASH`_IjALANCE-`CAM/GUIDE (2 X VENT) _ 19 L-7725 2- RIGID"VINYL SASH STOP (2 X FRAME) 20 L-7727 2 BLOGK TACKLE, BALANCE BSI Botance Systens 2t L-7539 2 VENT'..LIFT_-LATCH 6063-TS ALUMINUM 22 L-7523 IX LATCH VENT LATCH SPRING STAINLESS STEEL 23 x AS REWD GLAZING; SILICONE SEE GLAZING ® SHT. 3 24 r 2 Lanlnated�Gtoss SEE GLAZING DETAILS 25 HC-057-1 2 VENT�LIFP•LATCH MOLDED NYLON 26 HC-058-1 2 VENV3WtEPCXATCH MOLDED NYLON_ 27 >• 2 FRAME-zSILL FOAM GASKET _ SELF ADHESIVE 28 HC-026-1 1 SCREENfRAME;&''MESH 29 L-7730 1 PRODUCT LADED 30 31 SM-5504 AS REWD. JOINT''S_EALANT.. SM-5504 32 AS REQ'D PERIMETER ACRYLIC CAULK OS1 POLYSEAMSEAL m compfyitrg with the F)0rtda D�i)d(ag CodR Aeeeptwew No ILli•.Z.I 8xpiratlon�I e6G0idnadOPtn �! L