Loading...
HomeMy WebLinkAboutProduct Approval; Swinging Exterior Door Assemblies'MM.� ��'.' ....� ems. � .,'i� BCIS Home Log In User Registration ' I am Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIs site Map Links Search Fl�rica P Product Approval � 0 USER: Public User REVIEWED FOR Product Aooroyal Menu > Product or Aoolicatlon Searrh > @polication List > Application Detail CODE COMPLIANCE �{I� -R10 STFL# FL14569 UCIEJ�p&N �e ®®Y RevisionApplication Code Version 2017 ®C � Application Status Approved *Approved by DBPR. Approvals by DBPR shall be revALS;an tifafl by the POC and/or the Commission if necessary. LL n� 0 N, Comments U cn ¢ Q . ¢, ,LiZ-r-�—� n Archived o I_ O i_ O �, Product Manufacturer 3ELD-WEN 2 z �wQ<l Address/Phone/Email 3737 Lakeport Blvd 7 7 J Klamath Falls, OR 97601 ffs0m0 _, C rD ILI p I (800)535-3936 Lu fbcl@jeid-wen.com ` , c O Authorized Signature Rylee Sumner Fricks 5 ;- :;� ; `? fbcl@jeld-wen.com r d_ < 71 Technical Representative 3ELD-WEN Corporate Customer Service r j Address/Phone/Email 3737 Lakeport Blvd. == ' Klamath Falls, OR 97601 + (800)535-3936 j customerserviceagents@jeld-wen.com 41 Quality Assurance Representative Address/Phone/Email .r -s� Q' { Category Exterior Doors �ta ¢ a �_ U u; X �= =� li Ij Subcategory Swinging Exterior Door Assemblies ¢ C5 Q _ _ w 1Nir, Y1. aa°'.0o-01 o J t I Compliance Method Certification Mark or Listing ¢¢ s Z rr: a o U cc H J U) l_ o L 'I Certification Agency National Accreditation & Management Institute 3 : Validated By National Accreditation & Management Institute Referenced Standard and Year (of Standard) Standard Year TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL14569 R10 Enuiv ASTM E84 Equivalency Letter SS 2017-06-31 pdf Product Approval Method Method 1 Option A .ford ; r,OQ. 0 Date Submitted 05/13/2019 Date Validated 05/15/2019 Date Pending FBC Approval Date Approved 05/17/2019 Summary of Products FL # Model, Number or Name Description 14569.1 Contours Steel, Wood Edge Full Late Door, Outswing, 6'-0" x 6'-8" Limits of Use Certification: Agency Certificate Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes FL14569 R10 C CAC NI006255-R%ndf Quality Assurance Contract Expiration Date Impact Resistant: Yes 09/30/2027 Design Pressure: +60/-60 Installation Instructions Other: Product must be installed per manufacturer FU4569 R1QII 3W0509-03 Installation,odf Instructions as stated on drawing 1W0509-03 Verified By: Hermes Norero 73778 Created by Independent Third Party: Yes Evaluation Reports FL14569 RIO AE PER3392.Rdf Created by Independent Third Party: Yes 14569.2 Contours Steel, Wood Edge Full Ute Door, Inswing, 6'-0" x 6'-8" Limits of Use Certification. Agency Certificate Approved for use in HVHZ: Yes FL14569 RIO C CAC NI006255.02-114.odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 06/30/2027 Design Pressure: +60/-65 Installation Instructions Other: FL14569 R10 11 3W0509-04 Installation.odf Verified By: Hermes Norero 73778 Created by Independent Third Party: Yes Evaluation Reports FL14569 RIO AE PER3393.odf Created by Independent Third Party: Yes 14569.3 Contours Steel, Wood Edge Full Ute Door, Outswing, 6'-0" x 8'-0" Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes FL14569 RIO C CAC 1V1006254-117.odf Quality Assurance Contract Expiration Date Impact Resistant: Yes 09/30/2027 Design Pressure: +50/-50 Other: Installation Instructions PL14569 RIO I1 3W0509-01 SS 2015-07-02 odf Verified By: Hermes Norero 73778 Created by Independent Third Party: Yes Evaluation Reports EL14569 RIO AE PER3391.odf Created by Independent Third Party: Yes 14569.4 Contours Steel, Wood Edge Opaque Door, Inswing/Outswing, w/ or w/o Impact & Non - Impact Rated Glazed Sidelltes, 12'-0" x 6'-B" Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Certification Agency Certificate FL14569 RIO C CAC N1012741-Rl N1012741 01-Ri odf Quality Assurance Contract Expiration Date Impact Resistant: Yes Design Pressure: N/A Other: 04/30/2028 Installation Instructions FL14569 RIO II IW032O12FL Installation rid Verified By: Hermes Norero 73778 Created by Independent Third Party: Yes Evaluation Reports FL14569 RIO AE PER3321.odf Created by Independent Third Party: Yes 14569.5 Contours Steel, Wood Edge Opaque Door, Inswing/Outswing, w/ or w/o Impact & Non - Impact Rated Glazed Sidelites, 8'-4" x 8'-0" Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Certification Agency Certificate FU4569 R16 C CAC NI012740-R1.odf Quality Assurance Contract Expiration Date Impact Resistant: Yes 04/30/2028 Design Pressure: +45/-45 Installation Instructions Other: FL14569 RIO II JW072012FL Installation odf Verified By: Hermes Norero 73778 Created by Independent Third Party: Yes Evaluation Reports FL14569 R10 AE PER3322.odf Created by Independent Third Party: Yes 14569.6 Contours Steel, Wood Edge Opaque Door, Outswing, w/ or w/o Sidelite, V-11" x 6'-8" Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL14569 R10 C CAC NI011082-R3 pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 08/31/2027 Design Pressure: N/A Installation Instructions Other: FL14569 R10 II S-2104 Installation Ddf Verified By: Hermes Norero 73778 Created by Independent Third Party: Yes Evaluation Reports FL14569 R10 AE PER3398.Ddf Created by Independent Third Party: Yes 14569.7 Contours Steel, Wood Edge Opaque Door, Outswing, w/ or w/out Sidelites, 8'-11" x 8'-0" Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL14569 R10 C CAC NI011096- 3 NI011096 01-R2 Ddf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 08/31/2027 Design Pressure: N/A Installation Instructions Other: FL14569 R10 II S-2108-01.Ddf Verified By: Hermes Norero 73778 Created by Independent Third Party: Yes Evaluation Reports FL14569 RIO AE PER3832.pdf Created by Independent Third Party: Yes Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-07-1824 The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850AS7.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click )ig L. Product Approval Accepts: :' 19% NNI Credit Card ,Safe I JELBrV ,N® Steel Ej%rSAVER'L10M=,r- "FYODD®GEQPAWSTMOII7SM IAfPAOI0001iUHt7S1Yl7lfA tT91X0flT&1DtZF17E8 f. THIS PRODUCT f5 t>E IBNED TO aCAIPLY WRH >Fg GURREiIf ftORmA OI1L"% ME ANO Htcli vELol�rr FTURRtt:Ml£ zDNE ?NHZ• RErxnREr�NTs.. 2 WWO O"M V UWSSF IMT M AW O W PROPERLY M TRANSFER OW TO Tn.STRUCMV J. PROW ANCHORS Wffia 09 AS tiSTFFF AND SPA= FMR ANCHOR WM MOMM ANCHOR a m or m Mm mAMt -wu BE art= mL t1RESSTN6 08 S7UCLif, 4. SEE TA@4£ 1 ON M SHEET FOR DESIGN PRESSURE RAT>IYS'w S TFBS Pgopwr Am THE )9ATT3t REQ I MEMS FOR `HVHZ" 7ONK SEE THE OE&f,rl PRESSURE CWr BEUIW. 8 DOORS ARE IMPACT RATED MO 00 NUT REQUIRE A1WM1-aoF, APPROVED INQACT RHSW NT SHilUM. 7. 1fWSF(-DADE APPROVED 10PA£T Rf WAW SHUTIEM ARE REQUIRED FOR StDELNES B. SJDEUTES ARE AN MXW AND CAN BE USED IN A WiME OR DOUBLE 1TEb1DEN1o1L1115UG4THT6TFELTIO tCaaunm,roegeawe b�1 l Cl�StPON&�{f CflY57AUCT1Q�/5: 24 ge: (aO2OjoVhbUm I*kness, Gairenized Steil A-525 tommereTal gas6ty - MW per *W 620 with average mko" yTold strength Fy(tWe}=30.627 Psi, .lEtA*g, EVOded Win` m7h 1.0 to 1.25 IbWd denshy, by ov Pam The active add Na66de Panels dr8!obstructed from 24M (dow min) golvoaized steel, The faro rhea! tops Died bottoms are %t V ovrr the tap add tibttom roils. The top LVL rag rneesures 1.67' Wide x 1.0' high. The $feel boliom td rxeasares 1.67' Vile x 1.21' high.. The opUdhal *dad bottom rag measures 1.67' wide x 1.25' high, . Ttm soles 4f -the loge sheet arc raH formed onto the OL I*A 'stdo cmd Pmderaso Piro hinge stile ivtifcb me am I.W x I . The hetedor cavity is fiTsd wRFr poJystyre>nl, The tope. sheets 'dro glued to the po1}stMo. ed LYe COO, Iffmm sosh is. mr4tructed from 24dC (WO- mta j yohmdald ste the edges of M4 face OW are pent 9O'' over the pa"Ve" — end gored ta. e%' hp ddefte pdrlels are routed to mcow 00 OVL.Up me lianas or.the opuohol Tdreity Ugm fiantm (Soo .sheet 7 for 014609 deto$s:) the as tromes we aret the Near aid mrWor, ime tkresfriietiac 'The frames ofa consbacfed from Pmdemso Pare jombs meosvrtdg 1.25' Wide x 4:563' deep. The dow and s�IoRe head - Idbs aro mortised CM bait joined to the side loft add bandied with (3r16GA Y x 7116' town W&e stoples fie unRs erne a high dam balm fore fmpeiiai Oceshafd moomring 5.28' dreg x I.75' high pr.o staddolf bump face Pemko tprosfx W rneasunhg 4.d11' deep x W' The fhroshoMs are attached to the frames With (3j 166A 2• x 7%16 aroxn Vlfa staples. F h me TYP. 74r UV OA FRAME MOTH 'm*3 PLAN£!. WW A J6' W. 04 W/A5fILlr�tt. PANEL WIDTH ` 96. mC1W 92 ACM MAX. O.LPAM FJEiGT(r J ZS' WAE TGttf tL� 75' TTP 700' .ills' TV. MAX OA FRAM 75' muu. BAR TV?. J6' till,% OA PANEL WTDTN MAX ,r OA PANEL f$/GHf 97.5• OA I Un hVW n .szs` i A0�${,Ot115WING Ilow 1x41f (Xx). V 75• NAIL a.A.yIEWFD Rm FJf1ERtDR FRAlfE MOTH m..rep T36• Mv OA ' aR11lY fIM!! -ir I 96` q llQA7AL OA mm PANEL. 097.5' mm HEIGHT- 97.5' ht4x m OA FRAfCE FRWE fRA1dE Off J4 Din r:rr�a r .75' ..1 m.. 6 —mW150.7W, al, FRAME WIDTH — 71+P }25' W m is DA J6' L6jx. OA PANEL i Gt PAMj WlDW WfASI1TAGAL OE 1 T4ES m RA1gIG-1�iIDTE tYVER 1611TNATliRi 6E41FRETffJIT t5 Wi6udtP FT�f DlRE!6teta W/lUGH off ]IfH65HOlD _ SOLpE.eOpR ut8f (!c ex ;A ov. N/lPU A'S4-r1t�Ct St�tt6 "m po -W psi 460 pd -60 osf am DOOR gM (xx, =," a m) W/O 101- 00 SW= 07 psi -0 W +47 pd -43 psi 15.5` rt u OA. Sit apE F7Nt1E WIDTH 14' WX. OA PANEL WWW f T25' Ma OA aL.a. mm 79.1W UAX OA D.L0. HEIGHT j iOl£ aU[ tjj�1ma (ihLCOxO) tar/ mON-ILr a g. za :, 5 own V7£WA'a.pRtl,4t E1(fERIOR 1 Qs I5.5• u4x OA. �z Slam F1wx tm1H 14' WtX QA PANEL W0174 41 dd IS o 7.125.. JI X 4 #A 1XLa mm 71W, o OA y HEtGTR t � - PrePorCd 8y: 7k `ate PJJU G DROPS INC. Phoo& 407-644-6957 era For 407-644-M S 2108-01 r i orb to 20 1 Z4 �- aig f.A lip * NIZ I yb�N -4 ell A-11 !11 I NO JELDVEN, HVC. =7 UKMfff BLVD, KUUA* PAW, OR, 9760! TOU 'V ,WV1 OM MAW SEE OM 2.19 2O 4 5 7 1 15 SHEET f 2142 34 SEE MOTE 4 ON Mr. 4 EUMM . . `NI\ $1 10 1 1 SEE DETAIL 5 d ;; 5. MORt PONTAL CR��O$S�� SECTION � TC SHIM [� JAM�TOOCK 1.,50" MtN CONCRETE/ EMBED MASONRY BY .07NM PANEL THIS SEE NOTE 4SEE DETAIL ON SOT. 41 r ON 7HlS 7 t4 sHEEr ill HORIZONTAL_ CROSS SECTION T IM E JAL ASTRAGAL t3 6 5 6 3 D f9 1 2 S�HEU SEE NOTE 7 EXTERIOR ON SH% 4 1.75" MIN: AANEL TtiK. ,' x 1-7 � ,, as ON SHEETS HORIZONTAL %88 SECTION Nl &EEO BLI EMBED. ASMACAL THROW BOLTS (2) TOTAL., .(1 EACH) {' 6.31' tNA x 9.4' L.G. At TOP & 9OMM sEt 1 ANAL 11 NOJEt 9M 24 NOT SHO1WN TIM VQV FOR CLWilitrt, AN".G_S F. Nr, r �a �n cr p� nri Pre�nnd BuaDa�c a rric. Fww.407-64{-6957 Far. 407-444-2566 DAM 1f--15- OML N.F.. n c.04DRAWNG F NO.: S-21D$- sates or SEE. NOTE ON SHT. SEE NOV. ON SHL' FOR OPTIONAL 1/2' & 1" LG, 3f SEE' SHEEP j"! SEE NOTE 6, ON SK 4. 1 25 SEE NOTE 5 ON SHf. 4 SET; DE1AH: 5 ON SHEET 5 ORIZ NTAL C S. C SIDE T6 T LA JAMN NpTES: 1. SPACING FORtTEA1 #26 THE /10 x Y PFN SC11E1VS ATTACAING THE IAtPERIAk ASTRAGAL 10 ENE IW Cr 000R IS As FOLLOWS .FROM 7HE TOP om & w 80TY&A UP: 1.0 , 2.5 4.0; 9.5', 110 ; 16:0' & 26,0° Z SPACING tTiR ITEM #8 X 1 1 f2' PIASCREW IS A5' FOLI,QR+s`. 3:0' 1N FROM EACH CORNER. OIN .THE SIDES. VERTICALLY. FOR THE SZIiFdM PANELS.• .3,0", 13:5 ; 24.5 , 36.e. 46.0, 57.5 , 05' & 74,0 3 SPACING FOR ITEM 131 THE IM x 414' MAD TR A# NAIL ATTACHLNO THE OVARTER ROUND TO THE .SIDL:LITE AND THE M WON CAP TO THE MULWN BAR YERTICAUX, IS AS MOM TOP. & 601TOA1 1.25' IN FROM EACH CORNER WILT( (1) NAIL AIM -SPAR, E Sf13ES MMUY: 1.25' FROM SO OM & SIX MOORS EQUALLY SPACED ON THE FIELD: 4. WHEN ATTACMAtG THE SUVKE PLATE TO THl JAW AND BUCK USE M J25, A 18 x 2 112' PFH WOOD SCREW WNLN ATTAC?iINO THE STRIKE PLAIC TO THE JAMB AND SID M JAMB AT THE MUWON USE ITEM 124, A #8 x 2' PFH WOOD SCREW 5, SPACING FOR MV JR$ 7NE #S .x 2 112' PFH WOOD SCREWS ATTACMG THE Ojo Miss . H AT TK MUWOM IS AS MUM- 6.0' FRW ACH VERTICAL. CORNER WITH (0) MORE SCREWS E{3UALLY SPACED ON THE FTELO, C , M 57DE M PANEL IS SECURED E+RO THE OWIE JAW W/ M M. #D 5HJCONE Ly V ON THREE MMS AND Jle QUARTER ROUNDS SECURED: WITH. REA1.131. BRAD TRIM MU S x 3/4' LONG. 7, 1M111EPL ATTACMMG THE HINGE TO lK JAMB AND BLU USE REM #27, A 110 X 2" PRI SCR I WHEN ATTACHING THE .HINGE. TO THE JAMB AND SIOELAE JW AT THE MUM USE OW :114, .A. #10 x 1 314- PFH WOOD SMW- & SPACING FOR lTL ,10 THE J6 x 1 112' PANfW SCREW (1040 L11EFLt ) 15 AS FOLLOWS: MUM LIT1:.MK ! J M Dl M VERTIE•ALtY: 5.63 14,5 1, 23.25 32.i?6, 41', 405, s&W, 67.38" & 76.31'. SHTPUT£ Lmsyc T6P k {jOTTOb1• FRMk THE LEFT: 3.13' & S.W S.USE ITEM jf51 WHEN LNSTALUNG INTO WOOD SUBSTRATE AT HFAD 4 JAM USE fOl #25 WhV INS7ALl1N0. INTO iltHilONS. USE ltEM #16 WHEN PWAUM INTO CONCREXIMASO►IRY SUBST£#ATEE AT SIDELM SILLS. MEWIV 9Y OTHERS 1.75, HN. N PAM TW SEE NOTE 6 ON SHT. 4 W DETAIL 5 ON SHEET S RI20NT 0SS SEO' A S 0HfNr.E JAMB f-nNj#TO.WQOD NOT£ 7 1 SHT.4 i 3 17 3 3 LZ r f \ SEE NOTE 2 ON M. 4 6 2iSENOTE tL75" FOR OPTTLiNA4 1/2" it 1` 1,0. SEE %W 17 xl� paa X �SEE NOTE 2 31 SEE NOTE 3 3 'J.SHEEi 1 ON $HL 4 4 0,13' MIK FOR OPBt U 32 3s CLASS 1w. 1120 & 1` LO. SIE SHW 17 EXTERIOR WMRLOR SEE NOTE 2. ON SHT, 4 . Z NTAt CROSS SECT 18SEE NOTE 6 1 ON SHT. 4 SEE DETAIL 5 ON SHE£T 5 0w 94X S1tM y fwpw * !k Oxnrlle MPs v c. Pho k, 4W-644-8457 Foxy 407-644-2M s-21va-G� 74.50' MAX. OA IMIE M111 SEE O NIL 2 THIS SFIf. SEE DETAIL 4 ON THIS SK 00' 9.QO TYP {2 I St � SPACES lYP TIP. 2194* � SPAC ® JA SEE OUX 5 97.50" gxSOR CW THIS W. _ 24.0" OA FR4WI� M r FRAME s 2a�Da" ss.sa' is l Tw. WlYp " It SEE OUX, 3 ON THIS SHr mmm 0 D 16 SEE NOTE 7 SNEE€ 4 41 E; • O • 6 41 DM 2 - 6 WO .lava DETAIL 3 - 0 'TNRfSHoID ASTIWAI. STRIKE PLATE ASTRAt?fU. STRIKE PLATE MWIS TO mek DOOR 7A25" t= OA FRtW iO`M 9.w TYP. W OR 74,80" �� 5� B.J` S J `' .r TYP. SEE NOTE 5 ON SHEET 4 SEE DETAIL _ ON THIS SHT. !� in 2 24.W p2.W II aco. 36 625' 16 m'• 1 _ T.f_ STRIKE PLATES TKO ASTaOL SiRWE ' TE D A B >I SEE DETAIL 4 ON ms SW. f 15'd�)K C--S►NK• Q N f 1S S{ 25 5m NOTE to 4 ON swu 4 it ifl£RSWK FOR INSTALLAWN ANCHORS p ri e w •► s.) ... .p i tt-Jfi-01 c 0 �' y WEpmed gy SrJtr N.T.S. �.g ! f arc nn RW �,i• ��. Z �• +� E =J BMW Dim INC. PkW: 407-U4+ 6957 DRAA�NC NO.s S 2108-01 sus $ o! Fm 07-544-2JO. — 107W MAX O,A. FRAME WON ---� --- ^--� SEE MAIL 2 on SHEET 5 4:50' iYP. 15,4Y 1YP. SEE WAIL 4 -�! Y1P�' lYP i54?' 1YP ON SHEET 5 — . Tw. t-- no' t . --lw 7YP. i 6:00" 7YP: 6 SPACES iD 14:?5' 97M' MAX FPAVE NQt�yl1 ti! lit ili til 5 5 1YA- 1XP. 25 SEE NOTE ON SHEET 4 SEE IX AIL 5 ON SHEET .5.5 1 �r 3&625' 7YP. Sm DftAiL, 3 0M SHEET 5 =etc M [o, noN,S www FROM lNiom 8..125. 6.00° 1YP. E, 25,94' 6 SPACES ia.2s' 24:00' 26.00" Aw >Y 7 SPACES 12,2:: 97.5V SEE MAI MAX, ON SHEET 0.4nmw HmHT 12.00' 1 ` V.75' MAX. o.A f " fRAME WON VfEi?EA FROM 3 e.i 110- li 2594" . 24.6e 26.00' .L 7 g� id JERI SEE DML 4 ON SHEET S *w ,' PfMnA: 407 544-6s57 Fax: 407-644 2J66 v au [TEWP. EXTERlQR.T3" MIN. GLASS g m 1HICKNESS Q- REM. INTERIOR 5" CLASS 50 30 38 23 ON WE ? SM CIVING om opi la— fRAic SINGLE PANE'L%8" TEMPERED GLASS }iP POLYPROPYLENE THERMOM-106-3"0381 EXTERIOR 1 INTERIOR W25" TEMP. 1.00- ASIN. U 75" AIR SPACE TABS iHK.. �--�--T 0.-i25" TEMP. t ` .75" x .50" MtTERCEPT GLASS GLASS ""I STM SPACER par SEE NOTE 8. a0N SFlr 4 YAW OEWNL TRINV LEE FRAIJE 1 INSULATED TEWERE6 GLASS Ltm EU-= TYF. a Pits. EXTERIOR INTERIOR I UN. 0,125' TEMP. L125' AIR TNX. GLASS SPACE 0.T25" TEMP. .25" x .50" GLASS WERCWT SIM 'FACER SEE WE ON SHT. 448 45MAZINg QM TRIMIX WE E 112" INSULATED TEMPERED GLASS UiPOY.EV-5007 F. x � Prepved t3y: ; N:T.S. RW or v� • '� • omm Mom Ph ,Jo7 699557 rxrawuaa . S-2►OB-01 —r . 7 w� nre for. 407-60-230 1.67' � � 1;67- � � 1.57- J---T 1.67° I—T � 4.56" �tg' jj fP11, W000 B01TOAf RAIL t3 . WOOD mma SR 7 f VL LaTCif Sm E 1 } M TOP flAi1 . 3 a FINGER At"D 9.19 4 il 44. PONDEROSA. PINE g'ACC,it -- 1.67- 3 i 0.38" � 1 v.�7" Y.54` � = 1.54" }..59' D.53° a6z• P w BOT m RA@ sc CORNQi BLOCK FOfi AiP ON WFATNIERSmmay FRME 24GA (0207 STE!' 12: EL sTFFL 9ATTO ,ilAlt t0 LCL L 45 ROP4> fflES�Et ct-ttxv fops s5a t�rurn. PalrPlrpt? Potr>'ROP: d UDF x 3.0' LONG PLASTIC WE fUT tdATERW TR]NIWY PWIX ifTE K(T AdATERlAL O X PLASTIC i #E KIT IdATERL4L hQ' 1:50' PROVEp UNDER Nain-_OaOt APPROVEO UNDER Q i-0828,OYi APPROVER UNDER'NOA 910-IM.01. I.2S' _ a =p° 0. -� 0,62" Q36' �f--7 Ad t.75" 1.05 319 5141�W ROUND � �. i.7s } ASTT4GAL t44S 7W0 ,3f2- Z50,0 .d-.... a Dm- x 0' LONG SOLIS, t,. Q j ! QN TOP,, 1 ON BOTTOM -' �- 3254 zoD' 1 }.38" -1 t j 1.02. L oo t ! g„S m- smkr.1?[A7E Vim- HIM A* 8141E W �'LE�QLD �fLn Lxny Ca►� � RAGM MO- WE NNE o 6063-T6 A ZfMNdUAf 41 �L a ter SE 18 0.05i' 7fflG WALL ALUAWUA# - 8Y WPERIAL 28 PINE .(97.50' LOW) 1 J 4°, x 4" x .097' TRK. S M swim MOD INSERT W. :OIA VARIES VVtrtf NRRO*w USED 4.04" - -{ FAL C G rr Al 9Y PEW - 4.00'>> r. �. Prpwo sy. suac N.T.S. tt `:11r = owe ar:. SYLN {�¢QD-LOL`K 1fLIICK ram •• .•a,�,a A r��� 6UROWG 0ROP5, W� n S 2108-01 }g LVL x 1.71' THK. ± a 407- 6