Loading...
HomeMy WebLinkAboutSoil Nuclear Gauge• Soil Nuclear Gauge Client: Project: Report Date: 1/21/2020 Andrew Berry 20-7861.00 'RNAr�`'P Test Method: ASTM D 6938 2909 N 25th Street Perez Residence Port St. Lucie Ft. Pierce, FL 34946 200 Bridlewood Way FBPE CA # 4930 Fort Pierce, FL 34945 607 NW Commodity Cove Port St. Lucie, FL 34986 Phone: 772-924-3575 1 Fax: 772-924-3580 Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) Probe Depth (in) Percent Compaction Min/Max Comp. (%) Remark 1 1/8/20 9906 - D1557 N/A 10.2 116.2 9.1 111.1 12 96 951105 Pass 2 1/8/20 9906 - D1557 N/A 10.2 116.2 8.4 113.0 12 97 95 / 105 Pass 3 1/8/20 9906 - D1557 N/A. 10.2 116.2 9.2 112.2 12 97 95 / 105 Pass 4 1/8/20 9906 - D1557 N/A 10.2 116.2 9.1 112.4 12 97 95 / 105 Pass 5 1/8120 9906 - D1557 N/A 10.2 116.2 9.8 111.3 12 96 951105 Pass 6 1/8/20 9906 - D1557 N/A 10.2 116.2 9.5 110.7 12 95 95 / 105 Pass 7 1/8/20 9906 - D1557 N/A 10.2 116.2 8.7 113.7 12 98 95 / 105 Pass 8 1/8/20 9906 - D1557 N/A 1 10.2 j 116.2 1 8.8 1 114.6 1 12 1 99 1 95 / 105 Pass Test Information Test # Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 1 Below Slab Grade: House, NE Comer 0-1' Troxler / T3440 / 27974 / Liverman, Robert 2 Below Slab Grade: House, Center 0-1' Troxler / T3440 / 27974 / Liverman, Robert 3 Below Slab Grade: House, SW Comer 0-1' Troxler / T3440 / 27974 / Liverman, Robert 4 1 Below Slab Grade: Guest House, SW Comer 0-1' Troxler / T3440 / 27974 / Liverman, Robert 5 Below Slab Grade: Guest House, Center 0-1' Troxler / T3440 / 27974 / Liverman, Robert 6 Below Slab Grade: Guest House, NE Comer 0-1' Troxler / T3440 / 27974 / Liverman, Robert 7 Below Slab Grade: Garage, NE Corner 0-1' Troxler / T3440 / 27974 ! Liverman, Robert 8 Below Slab Grade: Garage, Center 0-1' Troxler / T3440 / 27974 / Liverman, Robert Remarks Comments vv J O /q q 135 R F('f=V r t, Pass: Tests results comply with specifications Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. 1, 2, 3, 4, 5, 6, 7, 8: Below stripped surface 0-1, 1-2', HCP=40+, > 95 % Compaction, PASS. HCP tests are empirically correlated to the relative density of the soil. • vr.,4 C t-W JAN 2 2 2020 L ucie County, Permitting Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. Page 1 of 2 Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. • • Soil Nuclear Gauge Client: Project: Report Date:-1/21/2020 Andrew Berry 20-7861.00 ''FRNAToaPv Test Method: ASTM D 6938 2909 N 25th Street Perez Residence Port St. Lucie Ft. Pierce, FL 34946 200 Bridlewood Way FBPECA#4930 Fort Pierce, FL 34945 607 NW Commodity Cove Port St. Lucie, FL 34986 Phone: 772-924-3575 I.Fax: 772-924-3580 Test Results Optimum Maximum In Place In Place Probe Min/Max Retest Test Soil Moisture Dry Density Moisture Dry Density Depth Percent Comp. Test # Of Date Proctor ID Method Classification (%) (pcf) (%) (pcf) (in) Compaction N Remark 9 1/8/20 9906 - D1557 N/A 10.2 116.2 9.1 112.9 12 97 95 / 105 Pass Test Information Gauge Test # Test Location Elevation Reference Make / Model / SN / Calibrated Field Technician 9 Below Slab Grade: Garage, SW Comer 0-1' Troxler / T3440 / 27974 / Liverman, Robert Remarks Comments Pass: Tests results comply with specifications Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. 9: Below stripped surface 0-1, 1-2', HCP=40+, > 95 % Compaction, PASS. HCP tests are empirically correlated to the relative density of the soil. NN .... _\CENSF No 63218 _ a /21 �2020 el 4-Kent, P .44/ ' 01ri sion§1rEW Kber,/# 8 S% iOG/r 1DP.•�C) '///!�N11110\\�. Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Page 2 of 2