Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA- ENERGY EFFICIENCY CODE FOR• BUILDING CONSTRUCTION .Florida Department of Business and Professional Regulation' -. Residential. Performance -Method Project Name: . WYNNE-THE WINDSOR•IMPACT, Builder Name: WYNNE DEVELOPMENT. Street: Permit Office: : ST. •LUCIE: COUNTY .City, State, Zip:. FT.:PIERCE, FL, Permit Number:. Owner: Jurisdiction: Design Location:. FL, FortPierce County: St. Lucie -(Florida Climate Zone 2) . 1. New construction or.existing. New (From Plans) 9. Wall Types (1432.0 :sgft.). Insulation Area., ... . 2. Single family or multiple family, Single-family a. Concrete Block -. Int Insul, Exterior . R=4.1 1224.00 ft2 - b. Frame - Wood, Adjacent R=11.0 208.00 ft2 3. Number of units; if multiple family 1 c. N/A R= :ft2 4. Number of Bedrooms -3. d. N/A R= . ft2 10. Ceiling Types. (1783.0 sgft.) Insulation .:. Area .. . 5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 1753.00 ft2 6. Conditioned floor area above grade (ft2) 1753 b. Knee. Wall .()/ented) -R=19.0 30.00 ft2. . Conditioned floor area.below_gmde (ft2) -0 c. N/A R= ft2 11. Ducts R ft2 7: Windows(151'.4 sgft.) Description - Area a. Sup: Attic,- Ret: Attic, AH:,Attic - 6 175 a. U-Factor: Sgl, U=1:04- 1.11.36 ft2 SHGC: SHGC=0.29 b. U-Factor: Sgl, U=1.11 ': 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.27 a. Central Unit -34.8 SEER:15.00. c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A, ft2 a. Electric Heat Pump 34.8. HSPF:8.50 SHGC: . Area Weighted Average:Overhang Depth: 2.850 ft.: Area Weighted Average SHGC;. 0:285 14. Hot, water systems ,.• a. Electric. Cap:.40.gallons .: 8. Floor Types' (1753.0 sgft.j Insulation Area EF: 0.970 .a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft2 b. Conservation features b. N/A R= ft2,; None. c: N/A R= ft2. 15. Credits .. Pstat Total Proposed Modified Loads: 52.20 . Glass/Floor Area: 0.086 , PASS Total Baseline Loads: 53.92 hereby certify that the plans and specifications covered by - Review of the plans and 0 this calculation are in compliance -with the.Florida Energy- .Code. specifications covered by this calculation. indicates.compliance `' with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: 1-9-20 this building will be-inspected`for compliance with Section 563.908 4)I�' - Al ° -herebycertify-that that this building, as designed, is in compliance fY 9 9 Florida Statutes. with the Florida Energy Code... 01IVNE A BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air -handler enclosure qualifies as certified factory -sealed in accordance with R4013.2.1. = Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope.leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). . REVIEWED. FOR . CODE COMPLIANCE' T. LUCIE COUNTY 1/8/2020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition, (2CB0(eQnt Software Page 1 of 6 "FORM R405-2017 .INPUT SUMMARY: CHECK T REPORT PROJECT . Title: WYNNE THE WINDSOR IMP • Bedrooms:. 3 Address Type:' Street Address Building Type-, User Conditioned Area: 1753 Lot it. . Owner Name: ' Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case:' Yes PlatBook: Builder Name: IM'NNE DEVELOPMENT. Rotate Angle:. 0 Street: -Permit Office: ST. LUCIE COUNTY Cross Ventilation:. No County: St. Lucie . Jurisdiction: Whole House Fan:. . No City; State_; Zip: FT.'PIERCE-; . Family Type: Single-family. FL, New/Existing: New (From Plans) Comment:. . . CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site . 97.5 % 2;5 % - Winter Summer Degree Days Moisture Range FL; Fort Pierce FL_VERO BEACH_MUNI 39 90 70: 75 299 62 tow: -BLOCKS . -Nam. , . .Area. :Number-..e. Volume.: : . 1 Entire.House 1753 14024 .. SPACES.: Number: Name. Area Volume Kitchen . Occupants: .Bedrooms: InfiliD Finished -Cooled . Heated 1 MASTER BEDROO 224 1792 No 0 1 1 Yes- Yes Yes . 2. WIC : 63 504 No. .0 1: No: : Yes: Yes' ... .. .... .. 3 - MASTER BATH. 56 448 No - .. 0 .. .. V .. .... Yes .Yes .. . Yes - .. 4 M. BATH 61- 488- No' 0 1 . Yes Yes Yes 5.. . LAUDRY .. -:36 .. 288 .. .No . .0'. 1.. No . Yes . Yes . :. 6.. -BEDROOM-2 :. 180. 1440 No 0 1- 1`: 'Yet : Yes 7 DINING/GREAT R . 588. _ 4704 No .21 1 Yes ..Yes Yes 8 KITCHEN .-209 - ...1672 Yes 0 1 Yes Yes Yes 9 BATH.'.. 50:.. 400 . No 0= :.. 1.:: . Yes -Yes __ Yes 10 ' HALL 25 200 No 0' 1 No Yes Yes 11 FOYER 92: 736 No - 0 : -1 Yes, Yes Yes 12 BEDROOM 3.: :169 1352 No 0. 1 1 - Yes Yes -Yes FLOORS : # Floor Type Space: Perimeter Perimeter R-Value . Area Joist R-Value Tile Wood Carpet :.. - 1 Slab -On -Grade Edge, Insulatio MASTER BEDRO .37 ft .. 0 224 ft2 : .0 .1 .0 . . 2 Slab -On -Grade Edge Insulatio WIC 1 ft .0. 63 ftz ___ 0. 1 0 . 3 Slab -On -Grade -Edge, Insulatio MASTER BATH 8 ft 0 56 ft2 0 '1: - 0 : 4 Slab=On-Grade Edge Insulatio M. BATH 7 It 0 61 ft2 0 1 0 5SIab-On7Grade Edge Insulatio . LAUDRY Aft 0 36 W. _ 0-� , 1 0 FQRM R405-2017 INPUT. SUMMARY CHF-GKL15T REPORT . . FLOORS # Flobr Type Space Perimeter Perimeter R-Value . Area , Joist R-Value Tile Wood Carpet 6 Slab -On -Grade Edge Insulatio BEDROOM 2 12 ft : 0 180 ft2 0 A 0 7Sla6-On-Grade Edge Insulatio DINING/GREAT 50 ft 0 588 ft2 0 1 0. 8SIab-On-Grade Edge Insulatio KITCHEN 11 ft 0 209.ft2 ____ 0. 1 0 . 9 Slab -On -Grade Edge Insulatio _ BATH 5 ft 0 50 ft2 0 1 0 10SIab-On-Grade Edge Insulatio HALL 1 ft 0 25 ft2 ____ 0 1.. 0 11SIab-On-Grade Edge Insulatio FOYER 9 ft 0' 92 ft2.-0. 1 0 . 12SIab-On-Grade Edge Insulatio BEDROOM 3 - 14 ft. 0 169 ft2 0 1 0. ROOF, / Roof Gable Roof Rad Solar: SA Emitt EmittDeck . Pitch V # Type Materials Area Area Color Barr Abs or. Tested Tested Insul. (deg) 1 Hip Metal 1847 ft2 0 ft2 Light N 0.4 No 0:9 No 0 18.4 ATTIC. . RBS IRCC V # Type . Ventilation. Vent Ratio (1 in)- Area 1 Full attic Vented 150 1753 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type . 1 . Under Attic (Vented) MASTER BEDRO 30 . Blown 224 ft2 0.1 Wood 2 Under.Attic (Vented) WIC 30 Blown 63 ft2 .• 0.1 Wood . 3 Under Attic (Vented) MASTER BATH 30 Blown 56 ft2 0.1 Wood . 4 Under Attic (Vented) M. BATH 30 Blown 61 ft2 0.1 Wood 5 Under Attic (Vented). LAUDRY 30 Blown 36 ft2 0.1 Wood 6 UnderAftic(Vented) BEDROOM 30- Blown 1.80ftF' 0.1 Wood 7 Under Attic (Vented) DINING/GREAT 30 .: Blown . 588 ft2 0.1 Wood .: 8 Under Attic (Vented) KITCHEN 30 Blown 209 ft2 0.11 Wood 9 Under Attic (Vented) BATH 30 Blown- 50 ft2 0.1 Wood 10 Under Attic (Vented) HALL 30 Blown 25 ft2 0.1 Wood 11 Under. Attic (Vented) FOYER 30 Blown 92 ft2 0.1 Wood 12 Under Attic (Vented) BEDR60M.3 30 Blown 169 ft2 0.1 Wood 13 Knee.Wall (Vented) DINING/GREAT 19 Blown. 30 ft? . .0.11 Wood WALLS Adjacent Cayity Width Height Sheathing Framing :, Solar Below Space 1 E Exterior Concrete Block - Int InsNASTER BE 4.1 16 0 8 0- 128.0 ft2 0 0 0.3 0 2 W Exterior Concrete Block - Int InsiNASTER BE 4.1 7 0 8 0 56.0 ft2 0 0 0.3. 0 3 S Exterior Concrete Block - Int InsWASTER BE 4.1 14 0 8 -0 112.0 ft2 0 0 0.3 0 1/8/2020 4:43 PM . EnergyGauge® USA 6.0.02, (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6 FORM R405=2017 INPUT. SUMMARY CHECKLIST REPORT - WALLS. Adjacent Cavity Width Height Sheathing' Framing : Solar Below Space. 4 E Exterior Concrete Block - Int InsNASTER BA 4.1 :8 0 ' 8 0 64.0 ft2 0• 0 0.3 0 5 E Exterior Concrete Block -. Int Insul M. BATH 4.1 7 " 0 8 0 56.0 ft2 0 0. " 0.3. 0 . .6 E - . Exterior. Concrete Block- Int InsBIEDROOM 2 40 . 12 0 8: ..' 0': . • 96.0 ft2 .. 0-: : 0 ': .. 0.3 . • -0. 7' S Exterior -Concrete Block=Intins1ilINING/GRE ' 4:1 30 . ' 0 8' 0 240.0 V - -0 .0. 0.3 - 0 8 W Exterior Concrete Block- Int Inst3INING/GRE 4.1 20 0.- 8 0 -: " 160.0 ft? 0 ." 0 6.3 6 9 = W Exterior Concrete Block -.Int IrisulKITCHEN 4.1 11 0 8 0, 88.0 ft2 0 0 0.3 0 10 E Exterior Concrete Block- Int Insul BATH 4:1 5 0 .8' " " 0 : 40.0 ft2 0' 0 0.3 0 11 N Exterior Concrete Block- Int lnsul FOYER 4.1 8 0 8 0 64.0 ft2. 0 0 0.3 0 12 N Exterior Concrete Block - Int lnsul FOYER . 4.1 1 - 0 8 .0 8.0 ft2. -0 0 0.3 0. 13 W Exterior. Concrete Block - Int Inse EDROOM:3 4.1 13 . 0 8 0 . 104.0 ft2 0 : 0 0.3 0 14. N-- Exterior Concrete Block - Int InSBIEDROOM 3 .: 4.1 ..1.. .. 0 _8 0-' . •8.0 ft2 0 0.1 0.3. • 0 15 N' Garage Frame - Wood' BEDROOM 3 11 ..26" 8 208.0 ft2 ' 0.23 ."" 0.3 0 " DOORS .. . # Omt . Door Type Space , Storms U-Value Width'' Height' Area _ Ft In . Ft In. . I. N Insulated FOYER None .32 , 3 3 6 8 21.7 ft2 :.. :. : WINDOWS .... Orientation shown is the entered orientation _> changed to Worst Case. / Wall Overhang :. V # Ornt ID" Frame ", Panes • NFRC U-Factor SHGC Imp Area. Depth, Separation Int Shade Screening- 1 S 3 'Metal Low-E Single Yes 1.64 .:0.29. .'N' . 32.442 1 ft 0 in 1. ft 5 in Drapes/blinds Exterior 5 2 E 5 Metal : Low-E Single Yes :1.04 0:29. N :6:912 . .1 ft 0 in : 1 ft 5 in None None: 3 E 6. Metal' •Low-E Single Yes 1.04 0.29 N - 16.2 ft2. 1 ft 0 in 1 ft 5 in None . None - 4 .. S 7 Metal . Low-E Single Yes . 1.04 0.20 .. N.. 39.8 ft2.. 1 ft 0 in .1 ft 5 in .. None. . None..' 5 W 8 : Metal -Low-E Single-- Yes 1.11 . 0:27 N. 4.0.0 ft2. : 8 ft 0 in 1 ft 5 in •. None- None . 6 W A 3 Metal Low-E Single Yes 1.04 0.29 N 16.2 ft2. 1 ft 0 in. 1 f4 5 in.: Drapes/blinds Exterior 5 GARAGE. # Floor -Area ' Ceiling Area . Exposed Wall:Perimeter. Avg. Wall Height. Exposed Wall Insulation 1 806 ft2 806.ft?,- 26 ft. 8 ft 11 ' INFILTRATION # . Scope Method SLA CFM 50 ELA- EgLA -_ -ACH -ACH 50 . 1 :Wholehouse Proposed ACH(50) .'000254: 1168.7 64.-16 120.66 : :0881: -5 1/8/202.0 4.:43 PM . EnergyGau k).USA6:0.02;(Rev.-1) - FlaRes201TFBC 6th Edition (2017) Compliant Software : Page 4 of 6; FORM R405-2017 INPUT. SUMMARY. -CHECKLIST REPORT HEATING SYSTEM" # : System Type _ Subtype = : Speed Efficiency Capacity Block Ducts. 1 Electric Heat Pump/ - Split Singl HSPF'8.5' . ' 34.8 kBtu/hr :1 s01 COOLING SYSTEM .. System Type Subtype Subtype.. Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ . Split Singl SEER: 15.34.8 . kBtu/hi cfm: 0.85 :1 sys#1: HOT WATER SYSTEM #: System Type-;"SubType `; Location - EF: ,. " Cap 'Use SetPnt : : ' Cohservatiorf' " 1 Electric , None Garage 0.97 40 gal 60.9 gal:, 1.20 deg None SOLAR HOT WATER SYSTEM FSEC " Collector . Storage: Cert # Company.Name' System Model # Collector Model # Area Volume FEF None. -.None. DUCTS'.: / -- Supply — - Return — Air: CFM 26 CFM25 . HVAC # V: # Location R-Value Area Location Area . Leakage Type Handler TOT ::OUT' QN RLF: Heat Cool .1 Attic " 6 - 175 ft? Attic 55 ft2 Default Leakage Attic (Default) (Default) 1, 1 . TEMPERATURES Programabl'e Thermostat: Y Ceiling Fans:- Coolin Jan Feb Mar - Heating Jan Feb f X� Mar:. Apr- f Apr f May Jun - Jul Jun Jul May ri [X] Au • [ ] Aug X Se Sep I Oct :Nov: Oct Nov Dec Dec Ver Jan' Feb [X Mar [X A r [ .Ma Jun . Jul. [ )Au Se [X Oct X Nov Dec Thermostat Schedule: :HERS 2006 Reference Hours Schedule Type . . ..1 .. .2 3 . 4 .. 5.: 6 .: ; . . 7. 8" 9 10 .. 11 . 12. -Cooling (WD) AM. 78 78 78 78 . 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78- 78,- 78 78 Cooling (VVEH) : AM: 78 • 78 78- 78 78 78 78 .78: .78 78 78 - 78' PM 78 78 78 78. 78 78 78 '78. 78 - :.-78,.. 78 78 ...78 . Heating (WD) 'AM 66 66 -.66 66 66 68- -68 : 68 68 - w68 68: 68 PM 68 = 68 68 '68 68 68. 68.:. .68 68 68 66. 66 Heating (WEH) AM . 66 66 66 66 .66 68 68 N - 68 68 ,. 68 68 PM : - 68 -.68 - 68- - 68 68 68 68 68 : : 68 68- 66" -66 MASS Mass,Type Area Thickness Furniture Fraction . Space Default(8 lbs/sq.ft. - 0 ftz .. 0 ft. -0.3. -BEDROOM . . Default(8 lbs/sq.ft: ftz' _:.. ft ... 0:3 WIC . . Default(8 lbs)sq.ft. ft' ft . 0.3 M. BATH .: Default(8 Ills/sq.ft.. ft=. ft :. 0.3 KITCHEN . Default(81bs/sq.ft. :. ft: ft 0.3 BATH Default(8 Ills/sq;ft: ft' ft . 0.3 BEDROOM 2,. Default(8 Ibs/sq.ft.. ft' " ft U ENTRY . Default(8 Ibs/sq.ft:. ft2 ft -.0.3 -LAUNDRY. IRM R405-2017 INPUT- SUMMARY:'CHECKLIST REPORT MASS .. Mass Type Area Thickness Furniture Fraction: :Space - Default($ Ibs/sq:ft: ft' ft 0:3 : - GREAT/DINING Project Name: WYNNE THE WINDSOR. IMPACT. Builder Name:. WYNNE DEVELOPMENT Street:. Permit Office:: ST..LUCIE000NTY City, State, Zip: FT: PIERCE, FL, Permit Number:: U Owner:: . .... ... Jurisdiction: . . w. Design Location: FL, Fort Pierce - COMPONENT'- AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall tie' installed in the building envelope:: .: 'Air -permeable •insulation shall _: The exterior thermal envelope contains, a continuous air barrier., not, be used as a sealing material. requirements Breaks'or joints in the air barrier shall be sealed.. Ceiling/attic The air barrier iri-any. dropped ceiling/soffit shall.be aligned with .. The insulation in any dropped ceiling/soffit ' the insulation and any gaps in the.air.barriershall be sealed.. .shall be aligned. with the air barrier. • ' Access. openings, drop down stairs or knee wail doors to . . unconditioned attic spaces shall be sealed. Walls. The junction of. the foundation and sill:plate shall be sealed. 'Cavities within comers and headers of frame walls _ The junction. of the top:plate and'the.top of exterior walls shall be.. shall be insulated by completely filling the: cavity, . . ealed. "ing,a.thermal resistance of R-3s , . Knee walls shall be sealed. per inch minimum. . Exterior thermal envelope:insulation for framed .: . walls shall be installed.in substantial contact and continuous alignriment with the air barrier: Windows,:skylights ,': .The space,between window%doorjambs• andframing,.and and doors skylights and framing shall be sealed.' Rim joists- Rim joists shall include the air barrier.. Rim joists shall be insulated. Floors. The air barrier shall be installed at any exposed edge of : Floor framing cavity insulation shall be installed:to (including: •. = insulation.. maintain permarient contact with the underside of,: . above -garage subfloor decking, or floor framing cavity insulation : and cantilevered shall be permitted to.be in .contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the. . - - bottom. to the top of all perimeter floor framing members: Crawl space walls Exposed earth in unvented crawl spaces isha.11 be covered with Where -provided instead of floor insulation, insulation a Class I;vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. . Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces: Garage separation Air sealing shall be;provided between the -garage and conditioned spa s. Recessed.lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building. shall be sealed to the. drywall. thermal envelope shall be air tight and IC rated.. Plumbing and wining.: Batt insulation shall be cut n around neatly to, fit wiring. and_ plumbing in exterior walls, or insulation that on installation readily conforms to available space'shall Shower/tub . The air barrier installed at exterior walls:adjacent to showers and Exterior walls: adjacent to showers'and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated.: Electrical/phone box or The air.barrier.shall be installed behind electricalor communication. exterior walls boxes or air -sealed boxes shall be installed. HVAC-register boots HVAC register boots that penetrate building thermal envelope shall be sealed to: the sub=floor ordrywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers Sealed: in a manner that'is recommended by the manufacturer... Caulking or other adhesive sealants shall not be used to fill voids a. -In addition,: inspection of log.walls shall be.in accordance with the provisions of ICC-400: 1./8/2020 4:43 PM- EnergyGauge® USA 6...0.-02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) -Compliant Software : Page 1 of-1 2017 EPL DISPLAY CARD. . ENERGY PERFORMANCE LEVEL (EPL) DISPLAY. CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the Energy Performance Index, the more efficient the home::. . 1. New home or, addition 1. 'New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2: Single-family.or multiple -family 2. Single-family ,': b). Return :ducts . R 6.0 c) AHU location Attic. 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. - 3 13. Cooling system: Capacity 34.8 . a) Split system. SEER -15.0.. 5. Is this a worst case? (yes/no) 5. Yes b) Single:package = :SEER . c) Ground/water source SEER/COP . 6. Conditioned floor area '(sq. ft.) 6. 1753 d) Room unit/PTAC EER e) Other 7. Windows, type and area . a) U-factor:(weighted average) 7a. 1.058 - b) Solar Heat Gain'Coefficient (SHGC) 7b.. 0.285. 14. Heating system: Capacity 34.8 c) Area.. 7c. 151.4 a) Split system heat pump .. HSPF .. 8.5 - b) Single'package heat:pump.HSPF 8. Skylights c)'Electric resistance COP a) U-factor:(Weighted average)' 8a. NA d) Gas furnace, natural gas.. AFUE - b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace,. LPG AFUE e f) Other 9: Floor type, insulation level: a) Slab-on_grade (R-value) 9a. 0.0 b) Wood,:.raised (R-value) 9b. 15. Water'heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.97 - .,b) Gas fired; natural gas EF 10. Wall type.and insulation: c).Gas fired, LPG EF . A. Exterior: - d) Solar system with tank EF .1. Wood frame. (Insulation R-value) 10A1.. e) Dedicated heat pump with -tank. EF. 2'Masonry:(Insulation R-value) 10A2. :4.1 f) Heat recovery unit:_ HeatRec%a B. Adjacent:. g) Other 1. Wood frame (insulationR-value) 10131. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVA,C.credits claimed (Performance -Method) 11. Ceiling ;type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11 b: c) Whole house fan No c) Knee walls/skylight walls 116. 19.0 d) Multizone cooling credit . d) Radiant barrier installed. 11d. No e) Multizone heating credit f) Programmable:thermostat Yes 'Label required by Section R303.1.3 of the Florida Building•Cbde, Energy Conservation; if not DEFAULT.. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy savingfeatures which:will'be installed (or exceeded). in this home before final inspection. Otherwise,.a new. EPL display card will .be completed based on installed code compliant features. - Builder Signature: Date: Address of.New Homek O.-Q-GA_') City/FL Zip:: FT. PIERCE, FL 1/8/2020 4:43:52 PM. EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software .Page 1 of 1