Loading...
HomeMy WebLinkAboutCertificate for Design Load ComplianceL At ti Planning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (77.2) 462-1553 Certification for Design Load Compliance Project Name: Crippen Residence Project Address: 24909 Orange Ave Ft. Pierce, FL 34945 Permit #: Occupancy Type: R-3 Construction Type: 111-13 INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code Sixth Edition with 2017 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed Partially Enclosed Open 3. Risk Category:_I X II , III IV Exposure Category: B X C D 4. Design Wind Velocity 124 mph X ASD LRFD End Zone Width: 4 ft 5. Mean Roof Height < 20 FT ft Roof Pitch: 5:12 & 8::12 Parapet: n/a ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: +21/-33 Zone 2: +21/-57 Zone 3: +211-84 Zone 4: +33/-39 Zone 5: +36/-48 Garage: +30 /-37 7. Design Loads: Floor: n/a PSF Roof/Dead: 20 PSF Roof/Live: 20 Balcony: n/a PSF Dock: n/a PSF Deck: n/a PSF Stairs: n/a PSF Fence: n/a PSF Railings: n/a PSF 8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2,000 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forc 5ro'Wfic� Michael Lue oo ° d 0 Print Name Cert # & Co. Cert Auth. FL Certification#: PE 47520/ SI# 1061 - COA # 8662 /fN 75 %'0 to f' Zi. ignatuKATE,Qtl Sea,(° 0: L Engineering, Inc., 2030 37th Ave., Vero Beach, FL 32960 0° ° ;�. q.✓ti Company Name & Address �o 'iz07%20�8