Loading...
HomeMy WebLinkAboutEnergy Codei I FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method d Project Name: CRIPPEN RESIDENCE Builder Name: Street: 24909 ORANGE AVENUE Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: SCOTT CRIPPEN Jurisdiction: County: St. Lucie (Florida Climate Zone 2 ) Design Location: FL, Fort Pierce 1.^ New construction or existing New (From Plans) 9. Wall Types (3231.0 sqft.) Insulation Area 2961.00 ft2 a. Concrete Block - Ext Insul, Exterior R=4.0 2. Single family or multiple family Single-family b. Frame - Wood, Adjacent R=23.0 270.00 ftZ 3. Number of units, if multiple family 1 c. N/A R= ft2 0 d. N/A R= ft2 4. Number of Bedrooms 10. Ceiling Types (3958.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=30.0 3958.00 ft2 6. Conditioned floor area above grade (ft2) 3716 b. N/A R= ft2 R= ft2 c. N/A I Conditioned floor area below grade (ft2) 0 11. Ducts R ft2 7 Windows(590.4 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: A/C 6 175 b. Sup: Attic, Ret: Attic, AH: A/C 2 6 135 a. U-Factor: Sgl, U=0.33 401.11 ft2 SHGC: SHGC=0.18 12. Cooling systems kBtu/hr Efficiency b. U-Factor: Sgl, U=0.35 168.00 ft2 a. Central Unit 36.0 SEER:17.00 SHGC: SHGC=0.16 b. Central Unit 25.2 SEER:17.50 c. U-Factor: Sgl, U=0.33 21.33 ft2 SHGC: SHGC=0.13 13. Heating systems kBtu/hr Efficiency d.' U-Factor: N/A ft2 a. Electric Strip Heat 27.0 COPA-00 17.0 COPA SHGC: b. Electric Strip Heat -00 i Area Weighted Average Overhang Depth: 3.711 ft. 14. Hot water systems Area Weighted Average SHGC: 0.173 a. Propane Cap: 50 gallons 8. Floor Types (3716.0 sqft.) Insulation Area EF: 0.600 a. Slab -On -Grade Edge Insulation R=0.0 3716.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits None Total Proposed Modified Loads: 97.17 PASS 'lass/Floor Area: 0.159 Total Baseline Loads: 106.81 I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. /--N _1 _n I hereby certify that this building, as designed, is in compliance with the Florida Energy Cie. _ I A� OWNER/AGENT: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code.. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: -fHE S�gTFo Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this proly t requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). VVO' W N01 ® 4 .MIS Page 1 of 7 10/28/2019 8:43 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software INPUT SUMMARY CHECKLIST REPORT ORM R405-2017 PROJECT Title: CRIPPEN RESIDENCE Bedrooms: 0 Address Type: Street Address Building Type: User Conditioned Area: 3716 Lot # Block/Subdivision: Owner Name: SCOTT CRIPPEN Total Stories: 1 PlatBook: # of Units: 1 Worst Case: No Street: 24909 ORANGE AVEN Builder Name: Rotate Angle: 0 County: St. Lucie Permit Office: ST. LUCIE COUNTY Cross Ventilation: No City, State, Zip: FPIERCE, Jurisdiction: Whole House Fan: No FLL , Family Type: Single-family New/Existing: New (From Plans) - Comment: CLIMATE - Design Temp Int Design Temp Heating Design Daily Temp y Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS ?; e Number Name Area Volume li 1 UNIT #2 1546 15460 I 2 UNIT #1 2170 21700 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfiIID Finished Cooled Heated 1 LIVNG AREA 667 6670 No 4 1 Yes Yes Yes 2 A/C 2 8 80 No 0 1 No Yes Yes 3 KITCHEN/DINING 556 5560 No 0 1 Yes Yes Yes 4 LAUNDRY 160 1600 No 0 1 Yes Yes Yes 5 POWDER 36 360 No 0 1 Yes Yes Yes 6 MUD ROOM 54 540 No 0 1 Yes Yes Yes I 7 HALL 130 1300 No 0 1 Yes Yes Yes 8 TROPHY ROOM 411 4110 No 3 1 No Yes Yes 9 HALLWAY 148 1480 No 0 1 Yes Yes Yes 10 BATH 2 112 1120 No 0 1 Yes Yes Yes 11 BATH 3 112 1120 No 0 1 Yes Yes Yes 12 BEDROOM 2 235 2350 No 1 1 Yes Yes Yes 13 BEDROOM 3 226 2260 No 1 1 Yes Yes Yes 14 CLST.3 35 350 No 0 1 No Yes Yes 15 CLST.2 45 450 No 0 1 Yes Yes Yes p 16 TOILET 24 240 No 0 1 Yes Yes Yes 17 M BATH 126 1260 No 0 1 Yes Yes Yes 18 W/H 6 60 No 0 1 No Yes Yes 19 A/C 6 60 No 0 1 No Yes Yes 20 WIC 2 67 670 No 0 1 No Yes Yes 21 WIC 91 910 No 0 1 No Yes Yes 10/28/2019 8:33 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7 INPUT SUMMARY CHECKLIST REPORT ORM R405-2017 !i! SPACES Number 'Name, Area Volume Kitchen Occupants Bedrooms InfiIID Finished Cqoled Heated 22 MASTERBEDROO 412 4120 No 2 1 Yes Yes Yes 23 PET ROOM 49 490 No 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio LIVNG AREA 46 ft 0 667 ft2 ____ 0 1 0 2 Slab -On -Grade Edge Insulatio A/C 2 1 ft 0 8 ft2 ____ 0 1 0 3 Slab -On -Grade Edge Insulatio KITCHEN/DININ 33 ft 0 556 ft2 ____ 0 1 0 of 4 Slab -On -Grade Edge Insulatio LAUNDRY 13 ft 0 160 ft2 ____ 0 1 0 5 Slab -On -Grade Edge Insulatio POWDER 13 ft 0 36 ft2 ----0 1 0 6 Slab -On -Grade Edge Insulatio MUD ROOM 4 ft 0 54 ft2 ____ 0 1 0 7 Slab -On -Grade Edge Insulatio HALL 19 ft 0 130 ft ____ 0 1 0 f 8 Slab -On -Grade Edge Insulatio TROPHY ROOM 1 ft 0 411 ft2 ____ 0 1 0 9 Slab -On -Grade Edge Insulatio HALLWAY 12 ft 0 148 ft2 ____ 0 1 0 3 10SIab-On-Grade Edge Insulatio BATH 2 23 ft 0 112 ft2 ____ 0 1 0 11SIab-On-Grade Edge Insulatio BATH 3 23 ft 0 112 ft2 ____ 0 1 0 12SIab-On-Grade Edge Insulatio BEDROOM 2 15 ft 0 235 ft2 ____ 0 1 0 13SIab-On-Grade Edge Insulatio BEDROOM 3 13 ft 0 226 ft2 ____ 0 1 0 14SIab-On-Grade.Edge Insulatio CLST. 3 1 ft 0 35 ft2 ____ 0 1 0 15SIab-On-Grade Edge Insulatio CLST. 2 5 ft 0 45 ft2 ____ 0 1 0 16Slab-On-Grade Edge Insulatio TOILET 3 ft 0 24 ft2 ____ 0 1 0 17SIab-On-Grade Edge Insulatio M BATH 14 ft 0 126 ft2 ____ 0 1 0 18SIab-On-Grade Edge Insulatio W/H 1 ft 0 6 ft2 ____ 0 1 0 19SIab-On-Grade Edge Insulatio A/C 1 ft 0 6 ft2 ____ 0 1 0 20SIab-On-Grade Edge Insulatio WIC 2 1 ft 0 67 ft2 ___- 0 1 0 21SIab-On-Grade Edge Insulatio WIC 1 ft 0 91 ft2 ____ 0 1 0 G 22SIab-On-Grade Edge Insulatio MASTERBEDRO 45 ft 0 412 ft2 ____ 0 1 0 23SIab-On-Grade Edge Insulatio PET ROOM 15 ft 0 49 ft2 ____ 0 1 0 10/28/2019 8:33 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7 INPUT SUMMARY CHECKLIST REPORT JRM R405-2017 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch ti Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) # Type u 1 Hip Metal 4155 ft2 0 ft2 Light N 0.6 No 0.9 No 30 26.6 i; 'i ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 3715 ft2 N N CEILING 77 # Ceiling Type Space R Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) LIVNG AREA 0 Blown 793 ft2 Wood 2 Under Attic (Unvented). A/C 2 0 Blown 8 ft2 . 1 0. Wood ' 3 Under Attic (Unvented) KITCHEN/DININ 0 Blown 556 ftZ 0.1 Wood 4 Under Attic (Unvented) LAUNDRY 0 Blown 160 ft2 0.1 Wood 5 Under Attic (Unvented) POWDER 0 Blown 36 ft2 0.1 Wood 'i 6 Under Attic (Unvented) MUD ROOM 0 Blown 54 ft2 0.1 Wood 7 Under Attic (Unvented) HALL 0 Blown 20 ft2 0.1 Wood 8 Under Attic (Unvented) HALL 0 Blown 130 ft2 0 0.1 Wood Wood 9 Under Attic (Unvented) TROPHY ROOM 0 Blown 15 ft2 i 10 Under Attic (Unvented) TROPHY ROOM 0 Blown 471 ft2 0 Wood 11 Under Attic (Unvented) HALLWAY 0 Blown 37 ft2 0.1 Wood 12 Under Attic (Unvented) HALLWAY 0 Blown 132 ft2 0 Wood 13 Under Attic (Unvented) BATH 2 0 Blown 112 ft2 0.1 Wood 14 Under Attic (Unvented) BATH 3 I 0 Blown 112 ft2 0.1 Wood 15 Under Attic (Unvented) BEDROOM 2 0 Blown 235 ft2 0.1 Wood !; 16 Under Attic (Unvented) BEDROOM 3 0 Blown 226 ft2 0.1 Wood 17 Under Attic (Unvented) CLST. 3 0 Blown 35 ft2 0.1 Wood 18 Under Attic (Unvented) CLST. 2 0 Blown 45 ft2 0.1 Wood 19 Under Attic (Unvented) TOILET 0 Blown 24 ft2 0.1 Wood 20 Under Attic (Unvented) M BATH 0 Blown 126 ft2 0.1 Wood 21 Under Attic (Unvented) W/H 0 Blown 6 ft2 0.1 Wood 22 Under Attic (Unvented) A/C 0 Blown 6 ft2 0.1 Wood 23 Under Attic (Unvented) WIC 2 0 Blown 67 ft2 0.1 Wood _ 24 UnderAttic(Unvented) WIC 0 Blown 91 ft2 0.1 Wood 25 Under Attic (Unvented) MASTERBEDRO 0 Blown 412 ft2 0.1 Wood 26 Under Attic (Unvented) PET ROOM 0 Blown 49 ft2 0.1 Wood WALLS Cavity Width Height Sheathing Framing Solar Below o Ad'acent 1 _ - 1 N JAW1 TypeSpace Exterior Concrete Block - Ext InddVNG AREA 4 17 10 12 11 230.3 ft2 0 0 0.6 0 _ 2 S Exterior Concrete Block - Ext InddVNG AREA 4 17 10 12 11 230.3 ft2 0 0 0.6 0 _ 3 E Exterior Concrete Block - Ext InsKITCHEN/DI 4 11 0 10 0 110.0 ft2 0 0 0.6 0 10/28/2019 8:33 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7 INPUT SUMMARY CHECKLIST REPORT )RM R405-2017 WALLS I! Cavity Width Height Sheathing Framing Solar Below i Adjacent Space _ - 4 S Exterior Concrete Block - Ext InsKITCHEN/DI 4 22 0 10 0 220.0 ft2 0 0 0.6 0 _ 5 N Exterior Concrete Block - Ext InsaAUNDRY 4 13 0 10 0 130.0 ft2 0 0 0.6 0 ,f 6 N Exterior Concrete Block - Ext InsLIPOWDER 4 9 0 10 0 90.0 ft2 0 0 0.6 0 _ 7 W Exterior Concrete Block - Ext InsuIPOWDER 4 4 0 10 0 40.0 ft2 0 0 0.6 0 _ 8 W Exterior Concrete Block - Ext InsMUD ROOM 4 4 0 10 0 40.0 ft2 0 0 0.6 0 _ 9 S Exterior Concrete Block - Ext Insul HALL 4 15 3 12 6 190.6 ft2 0 0 0.6 0 - _ N Exterior Concrete Block - Ext InsLIHALLWAY 4 9 10 12 2 119.6 ft2 0 0 0.6 0 � -10 11 N Exterior Concrete Block - Ext Insul BATH 2 4 16 0 10 0 160.0 ft2 0 0 0.6 0 _ 12 W Exterior Concrete Block - Ext Insul BATH 2 4 7 0 10 0 70.0 ft2 0 0 0.6 0 _ 13 N Exterior Concrete Block - Ext Insul BATH 3 4 16 0 10 0 160.0 ft2 0 0 0.6 0 _ 14 E Exterior Concrete Block - Ext Insul BATH 3 4 7 0 10 0 70.0 ft2 0 0 0.6 0 4 15 W Exterior Concrete Block - Ext InfiffDROOM 2 4 15 0 10 0 150.0 ft2 0 0 0.6 0 _ E Exterior Concrete Block - Ext InREDROOM 3 4 13 0 10 0 130.0 ft2 0 0 0.6 0 -16 17 W Exterior Concrete Block - Ext InsuICLST. 2 4 5 0 10 0 50.0 ft2 0 0 0.6 0 _ 18 W Exterior Concrete Block - Ext InsulTOILET 4 3 0 10 ' 0 30.0 ft2 0 0 0.6 0 _ W Exterior Concrete Block - Ext InsulM BATH 4 14 0 10 0 140.0 ft2 0 0 0.6 0 p -19 20 E Exterior Concrete Block - Ext InMASTERBED 4 7 0 10 0 70.0 ft2 0 0 0.6 0 21 S Exterior Concrete Block - Ext InUASTERBED 4 18 0 10 0 180.0 ft2 0 0 0.6 0 l 22 W Exterior Concrete Block - Ext InMASTERBED 4 20 0 10 0 200.0 ft2 0 0 0.6 0 _ E Exterior Concrete Block - Ext Ins9ET ROOM 4 8 0 10 0 80.0 ft 0 0 0.6 0 _23 24 S Exterior Concrete Block - Ext InsRET ROOM 4 7 0 10 0 70.0 ft 0 0 0 0 _ 25 W Garage Frame - Wood LAUNDRY 23 27 10 270.0 ft2 0 0.23 0.600000 0 DOORS # Ornt Door Type Space Storms U-Value Ft Width In Height Ft In Area g 1 N Wood LIVNG AREA None 39 6 8 48 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Overhang / v # Wall Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Single Yes 0.33 0.18 N 12.5 ft2 6 ft 0 in 0 ft 11.25 None None 2 N 1 Vinyl Low-E Single Yes 0.33 0.18 N 36.0 ft2 6 ft 0 in 0 ft 11.3 i None' None 3 S 2 Vinyl Low-E Single Yes 0.35 0.16 N 120.0 ft2 2 ft 0 in 0 ft 14.1 i None None 4 E 3 Vinyl Low-E Single Yes 0.35 0.16 N 48.0 ft2 16 ft 0 in 0 ft 14.12 None None 5 S 4 Vinyl Low-E Single Yes 0.33 0.18 N 54.0 ft2 2 ft 0 in 0 ft 11.25 None None 6 N 5 Vinyl Low-E Single Yes 0.33 0.18 N 12.3 ft2 2 ft 0 in 0 ft 11.25 None None 'J 7 N 6 Vinyl Low-E Single Yes 0.33 0.18 N 12.3 ft2 2 ft 0 in 0 ft 11.3 i None None 8 S 9 Vinyl Low-E Single Yes 0.33 0.18 N 54.0 ft2 2 ft 0 in 0 ft 11.3 i None None I{ 9 N 10 Vinyl Low-E Single Yes 0.33 0.18 N 36.0 ft2 6 ft 0 in Oft 11.3 i None None _ 10 N 11 Vinyl Low-E Single Yes 0.33 0.18 N 18.0 ft2 2 ft 0 in 0 ft 11.3 i None None _ 11 N 13 Vinyl Low-E Single Yes 0.33 0.18 N 18.0 ft2 2 ft 0 in 0 ft 11.3 i None None 12 W 15 Vinyl Low-E Single Yes 0.33 0.18 N 36.0 ft2 2 ft 0 in 0 ft 11.3 i None None 10/28/2019 8:33 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7 ?RM R405-2017 INPU I SUIVIIVIAKT t,rnrnLAQ WINDOWS Orientation shown is the entered, Proposed orientation. Overhang �/ # Wall Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 13 E 16 Vinyl Low-E Single Yes 0.33 0.18 N 21.1 ft2 2 ft 0 in oft 11.3 i None None 14 W 19 Vinyl Low-E Single Yes 0.33 0.18 N 12.0 ft2 2 ft 0 in oft 11.3 i None None 15 S 21 Vinyl Low-E Single Yes 0.33 0.18 N 54.0 ft2 2 ft 0 in oft 11.3 i None None 16 W 22 Vinyl Low-E Single Yes 0.33 0.18 N 25.0 ft2 2 ft 0 in oft 11.3 i None None. 17 S 24 Vinyl Low-E Single Yes 0.33 0.13 N 21.3 ft2 2 ft 0 in 0 ft 11.3 i None None d GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 756 ft2 756 ft2 27 ft loft 11 INFILTRATION r, # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 I Wholehouse Proposed ACH(50) .000445 4335.3 238 447.6 .1685 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 27 kBtu/hr 2 sys#1 a 2 Electric Strip Heat/ None COP:1 17 kBtu/hr 1 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 17 36 kBtu/hr cfm 0.7 2 sys#1 2 Central Unit/ Split SEER: 17.5 25.2 kBtu/hr cfm 0.7 1 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Propane None Garage 0.6 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM Collector Storage FSEC Cert # Company Name System Model # Collector Model # Area Volume FEF ft2 None None j! DUCTS —Supply — -- Return -- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location_ Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 175 ft2 Attic 65 ft2 Default Leakage A/C (Default) (Default) 1 1 [ ., A..:., a , 1jr ff2 Aftir. 45 ft2 Default Leakage A/C 2 (Default) (Default) 2 2 10/28/2019 8:33 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7 ;RM R405-20 INPUT SU TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling Jan Feb Mar [ Heating Jan Feb Mar [ ki ] Apr ] Apr [ ] May [ ] May Jun Jun rl rl Jul rl Jul Aug Aug Aug rl Sep Sep [ ]Oct Sep [X] Nov Oct Nov DecV Dec Jan Feb Mar IXl Apr [ ] Ma Jun Jul ntin Venting hermostat Schedule: HERS 2006 Reference Hours 11 8 9 10 12 rhedule Tvoe 1 2 3 4 5 6 7 ;ooling (WD) ;ooling (WEH) ]eating (WD) !eating (WEH) Mass Type Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. AM 78 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 PM PM 80 80 80 80 80 78 78 78 78 78 78 78 78 AM 65 65 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 �68 68 68 PM 68 MASS Area Thickness Furniture Fraction 0 ft2 0 ft 0.3 LIVNG AREA ft2 ft 0.3 A/C 2 ft2 ft 0.3 KITCHEN/DINING ft2 ft 0.3 LAUNDRY ft2 ft 0.3 POWDER ft2 ft 0.3 MUD ROOM ft2 ft 0.3 HALL ft2 ft 0.3 TROPHY ROOM ft2 ft 0.3 HALLWAY ft2 ft 0.3 BATH 2 ft2 ft 0.3 BATH 3 ft2 ft 0.3 BEDROOM 2 ft2 ft 0.3 BEDROOM 3 ft2 ft 0.3 CLST. 3 ft2 ft 0.3 CLST. 2 ft2 ft 0.3 TOILET ft2 ft 0.3 M BATH ft2 ft 0.3 W/H ft2 ft 0.3 A/C ft2 ft 0.3 WIC 2 ft2 ft 0.3 WIC ft2 ft 0.3 MASTERBEDROO ft2 ft 0.3 PET ROOM 10/28/2019 8:33 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: CRIPPEN RESIDENCE Builder Name: Permit Office: ST. LUCIE COUNTY Street: 24909 ORANGE AVENUE Permit Number: Y City, State, Zip: FT. PIERCE, FL, I Jurisdiction: W Owner: SCOTT CRIPPEN U Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall General The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls Walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with a material having a thermal resistance of R-3 sealed. Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. The space between window/door jambs and framing, and Windows, skylights doors skylights and framing shall be sealed. and Rim joists shall include the air barrier. Rim joists shall be insulated. Rim joists Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to maintain permanent contact with the underside of (including insulation. subfloor decking, or floor framing cavity insulation above -garage shall be permitted to be in contact with the top side and cantilevered of sheathing, or continuous insulation installed on floors) the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation Crawl space walls a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Duct shafts, utility penetrations, and flue shafts opening to Shafts, penetrations or unconditioned space shall be sealed. exterior Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on Narrow cavities installation readily conforms to the available cavity spaces. Air sealing shall be provided between the garage and conditioned spac Ds. Garage separation Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building thermal envelope shall be air tight and IC rated. Recessed lighting i shall be sealed to the drywall. Batt insulation shall be cut neatly to fit around wiring Plumbing and wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind noping and wering Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots that penetrate building thermal envelope shall HVAC register boots be sealed to the sub -floor or drywall. Concealed When required to be sealed; concealed fire sprinklers shall only be sealed in a manner that is recommended by the manufacturer. sprinklers Caulking or other adhesive sealants shall not be used to fill voids La. In addition, inspection of log walls shall be in accordance with the provisions of ICU-400. Page 1 of 1 10/28/2019 8:32 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software 20)7 EPL DISPLAY CARD --- ENERGY...PER 0 14AWC LEVEL�EP"�QJS ESTIMATED ENERGY PERFORMANCE INDEX* = 91 The lower the Energy Performance Index, the more efficient the home. 1. New home or,. addition 1. New From Plans) 12. Ducts, .location & insulation level a) Supply ducts 2. Single-family or multiple -family 2. Single-family b) Return ducts R c) AHU location 6.0 varies 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 0 13. Cooling system: Capacity a) Split system SEER 61.2 varies 5. Is this a worst case? (yes/no) 5. No e package SEER_ c) Groulnd/wate9source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 3716 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.336 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.173 c) Area 7c. 590.4 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 9a. 0.0 9b. 9c. 10A1. 10A2. 4.0 110131. 23.0 10132. 11 a. 0.0 11 b. 11 c. 11 d. No 14. Heating system: Capacity 44.0 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP 1.0 d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 15. Water heating system a) Electric resistance EF b) Gas fired, natural gas EF c) Gas fired, LPG EF 0.60 d) Solar system with tank EF e) Dedicated heat pump with tank EF 0 Heat recovery unit HeatRec% g) Other 16. HVAC credits claimed (Performance Method) a) Ceiling fans b) Cross ventilation No c) Whole house fan No d) Multizone cooling credit e) Multizone heating credit f) Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. r I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date:, Address of New Home: 24909 ORANGE AVENUE City/FL Zip: FT. PIERCE FL 10/28/2019 8:32:50 AM EnergyGaugeO USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1