HomeMy WebLinkAboutRevision; SHGC on Sliding Glass Doors & Energy Calcs to matchOFFICE USE ONLY: ee��
DATE FILED:
REVISION FEE: �- Q
PERMIT # Z9� �' 06-0 �-
RECEIPT # �i YL.2 M
PLANNING & DEVELOPMENT SERVICES
BUILDING & CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34982.5652
(772) 462-1553
APPLICATION FOR BUILDING PERMIRIEA(t�$10
PROJECT INFORMATION
LOCATION/SITE
ADD SS• o9 rv�
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #:
BUSINESS NAME: -(a ►'n
QUALIFIERS NAME: .gyp V / cD
ADDRESS: 5) -7dg!- e— 64nr
CITY: ACT g?JEdC'9" STATE:
PHONE (DAYTIME):
ME):
OWNER/BUILDER INFORMATION:
NAME:
ADDRESS:
ST. LUCIE CO CERT. #: 30
Z-•
dz.l •
A ZIP:
-'AX:
CITY: STATE:
PHONE (DAYTIME: FAX:
ARCHITECT/ENGINEER INFORMATION:
NAME:
ADDRESS:
CITY: STATE:
PHONE (DAYTIME):
SLCCC: 9123109
Revised 06130/17
ZIP:
ZIP: FILE, G�L1Qi
FAX: _..._. - -- -
R
.E C. EI V
DEC 16 2019
Permitting Department
St. Lucie County, FL
FORM R405-2017
-�� FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: CRIPPEN RESIDENCE
Builder Name:
Street: 24909 ORANGE AVENUE
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
Permit Number:
Owner: SCOTT CRIPPEN
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
t 1. New construction or existing New (From Plans)
9. Wall Types (3231.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.0 2961.00 ft2
b. Frame - Wood, Adjacent
R=23.0 270.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 0
d. N/A
R= ft2
10. Ceiling Types (3958.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Roof Deck (Unvented)
R=30.0 3958.00 ft2
6. Conditioned floor area above grade (ft2) 3716
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(590.4 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: A/C
6 175
a. U-Factor: Sgl, U=0.33 401.11 ft2
b. Sup: Attic, Ret: Attic, AH: A/C 2
6 135
SHGC: SHGC=0.16
b. U-Factor: Sgl, U=0.35 168.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.17
a. Central Unit
36.0 SEER:17.00
b. Central Unit
25.2 SEER:17.50
c. U-Factor: Sgl, U=0.33 21.33 ft2
SHGC: SHGC=0.13
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
27.0 COP:1.00
SHGC:
b. Electric Strip Heat
17.0 COP:1.00
Area Weighted Average Overhang Depth: 3.711 ft.
Area Weighted Average SHGC: 0.175
14. Hot water systems
a. Propane
Cap: 50 gallons
8. Floor Types (3716.0 sqft.) Insulation Area
EF: 0.600
a. Slab -On -Grade Edge Insulation R=0.0 3716.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
None
Glass/Floor Area: 0.159 Total Proposed Modified Loads: 102.17
C S
PA�7�7
Total Baseline Loads: 106.81
1 hereby certify that the plans and specifications covered by
Review of the plans andZHB
this calculation are in compliance with the Florida Energy
specifications covered by this
"=
Code.
calculation indicates compliance
�j" iiq'�e �,.��` VA
with the Florida Energy Code.
�n,�r'';..;.:¢ ,';•� �, O�
PREPARED BY:
DATE:. - IS
Before construction is completed
this building will be inspected for
compliance with Section 553.908
►■
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
CAD
with the Florida Energy Code.
WE'f��
OWNER/AGENT•
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH5 2.4.
ION
�F I E COPY
�'zo
'9
12/13/2019 10:01 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 7
CORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
-;
PROJECT
-
Title:
CRIPPEN RESIDENCE
Bedrooms: 0
Address Type:
Street Address
Building Type:
User
Conditioned Area: 3716
Lot #
Owner Name:
SCOTT CRIPPEN
Total Stories: 1
Block/Subdivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
24909 ORANGE
AVEN
Permit Office:
ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State, Zip:
FT. PIERCE,
Family Type:
Single-family
FL,
New/Existing:
New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp
Heating
Design
Daily Temp
V Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer
Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
UNIT #2
1546
15460
2
UNIT #1
2170
21700
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1
LIVNG AREA
667
6670 No
4
1
Yes
Yes
Yes
2
A/C 2
8
80 No
0
1
No
Yes
Yes
3
KITCHEN/DINING
556
5560 No
0
1
Yes
Yes
Yes
4
LAUNDRY
160
1600 No
0
1
Yes
Yes
Yes
5
POWDER
36
360 No
0
1
Yes
Yes
Yes
6
MUD ROOM
54
540 No
0
1
Yes
Yes
Yes
7
HALL
130
1300 No
0
1
Yes
Yes
Yes
8
TROPHY ROOM
411
4110 No
3
1
No
Yes
Yes
9
HALLWAY
148
1480 No
0
1
Yes
Yes
Yes
10
BATH 2
112
1120 No
0
1
Yes
Yes
Yes
11
BATH 3
112
1120 No
0
1
Yes
Yes
Yes
12
BEDROOM 2
235
2350 No
1
1
Yes
Yes
Yes
13
BEDROOM 3
226
2260 No
1
1
Yes
Yes
Yes
14
CLST.3
35
350 No
0
1
No
Yes
Yes
15
CLST.2
45
450 No
0
1
Yes
Yes
Yes
16
TOILET
24
240 No
0
1
Yes
Yes
Yes
17
M BATH
126
1260 No
0
1
Yes
Yes
Yes
18
W/H
6
60 No
0
1
No
Yes
Yes
-
19
A/C
6
60 No
0
1
No
Yes
Yes
20
WIC 2
67
670 No
0
1
No
Yes
Yes
21
WIC
91
910 No
0
1
No
Yes
Yes
12113/201910:01 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
SPACES
Number Name Area Volume
Ktchen Occupants
Bedrooms
InfilID Finished
Cooled
Heated
22 MASTERBEDROO 412
4120
No 2
1 Yes
Yes
Yes
23 PET ROOM 49
490
No 1
1 Yes
Yes
Yes
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood
Carpet
1 Slab -On -Grade Edge Insulation
LIVNG AREA
46 ft
0
667 ft2
____
0
1
0
2 Slab -On -Grade Edge Insulation
A/C 2
1 ft
0
8 ft2
____
0
1
0
3 Slab -On -Grade Edge Insulation
KITCHEN/DININ
33 ft
0
556 ft2
____
0
1
0
4SIab-On-Grade Edge Insulation
LAUNDRY
13 ft
0
160 ft2
____
0
1
0
5 Slab -On -Grade Edge Insulation
POWDER
13 ft
0
36 ft2
____
0
1
0
6 Slab -On -Grade Edge Insulation
MUD ROOM
4 ft
0
54 ft2
___-
0
1
0
7 Slab -On -Grade Edge Insulation
HALL
19 ft
0
130 ft2
____
0
1
0
8 Slab -On -Grade Edge Insulation
TROPHY ROOM
1 ft
0
411 ft2
____
0
1
0
9 Slab -On -Grade Edge Insulation
HALLWAY
12 ft
0
148 ft2
____
0
1
0
10SIab-On-Grade Edge Insulation
BATH 2
23 ft
0
112 ft2
___-
0
1
0
11Slab-On-Grade Edge Insulation
BATH 3
23 ft
0
112 ft2
___-
0
1
0
12SIab-On-Grade Edge Insulation
BEDROOM 2
15 ft
0
235 ft2
___-
0
1
0
13SIab-On-Grade Edge Insulation
BEDROOM 3
13 ft
0
226 ft2
_-__
0
1
0
14SIab-On-Grade Edge Insulation
CLST. 3
1 ft
0
35 ft2
-___
0
1
0
15SIab-On-Grade Edge Insulation
CLST. 2
5 ft
0
45 ft2
____
0
1
0
16SIab-On-Grade Edge Insulation
TOILET
3 ft
0
24 ft2
_-__
0
1
0
17SIab-On-Grade Edge Insulation
M BATH
14 ft
0
126 ft2
__-_
0
1
0
18SIab-On-Grade Edge Insulation
W/H
1 ft
0
6 ft2
_--_
0
1
0
19SIab-On-Grade Edge Insulation
A/C
1 ft
0
6 ft2
____
0
1
0
20SIab-On-Grade Edge Insulation
WIC 2
1 ft
0
67 ft2
-___
0
1
0
21SIab-On-Grade Edge Insulation
WIC
1 ft
0
91 ft2
___-
0
1
0
22SIab-On-Grade Edge Insulation
MASTERBEDRO
45 ft
0
412 ft2
-__-
0
1
0
23SIab-On-Grade Edge Insulation
PET ROOM
15 ft
0
49 ft2
-___
0
1
0
12/13/201910:01 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7
FORM R405-2017 INPUT 5UMMAKY L;Hh(:KLIS I KCPUK
ROOF
Roof
Gable
Roof Rad
Solar
SA Emitt
Emitt Deck
Pitch
V #
Type
Materials Area
Area
Color Barr
Absor.
Tested
Tested Insul.
(deg)
1
Hip
Metal 4155 ft2
0 ft2
Light N
0.6
No 0.9
No 30
26.6
ATTIC
RBS
IRCC
V #
Type
Ventilation
Vent Ratio (1 in)
Area
1
Full attic
Unvented
0
3715 ft2
N
N
CEILING
#
Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Unvented)
LIVNG AREA
0
Blown
793 ft2
0
Wood
2
Under Attic (Unvented)
A/C 2
0
Blown
8 ft2
0.1
Wood
3
Under Attic (Unvented)
KITCHEN/DININ
0
Blown
556 ft2
0.1
Wood
4
Under Attic (Unvented)
LAUNDRY
0
Blown
160 ft2
0.1
Wood
5
Under Attic (Unvented)
POWDER
0
Blown
36 ft2
0.1
Wood
6
Under Attic (Unvented)
MUD ROOM
0
Blown
54 ft2
0.1
Wood
7
Under Attic (Unvented)
HALL
0
Blown
20 ft2
0.1
Wood
8
Under Attic (Unvented)
HALL
0
Blown
130 ft2
0
Wood
9
Under Attic (Unvented)
TROPHY ROOM
0
Blown
15 ft2
0.1
Wood
10
Under Attic (Unvented)
TROPHY ROOM
0
Blown
471 ft2
0
Wood
11
Under Attic (Unvented)
HALLWAY
0
Blown
37 ft2
0.1
Wood
12
Under Attic (Unvented)
HALLWAY
0
Blown
132 ft2
0
Wood
13
Under Attic (Unvented)
BATH 2
0
Blown
112 ft2
0.1
Wood
14
Under Attic (Unvented)
BATH 3
0
Blown
112 ft2
0.1
Wood
15
Under Attic (Unvented)
BEDROOM 2
0
Blown
235 ft2
0.1
Wood
16
Under Attic (Unvented)
BEDROOM 3
0
Blown
226 ft2
0.1
Wood
17
Under Attic (Unvented)
CLST. 3
0
Blown
35 ft2
0.1
Wood
18
Under Attic (Unvented)
CLST. 2
0
Blown
45 ft2
0.1
Wood
19
Under Attic (Unvented)
TOILET
0
Blown
24 ft2
0.1
Wood
20
Under Attic (Unvented)
M BATH
0
Blown
126 ft2
0.1
Wood
21
Under Attic (Unvented)
W/H
0
Blown
6 ft2
0.1
Wood
22
Under Attic (Unvented)
A/C
0
Blown
6 ft2
0.1
Wood
23
Under Attic (Unvented)
WIC 2
0
Blown
67 ft2
0.1
Wood
24
Under Attic (Unvented)
WIC
0
Blown
91 ft2
0.1
Wood
25
Under Attic (Unvented)
MASTERBEDRO
0
Blown
412 ft2
0.1
Wood
26
Under Attic (Unvented)
PET ROOM
0
Blown
49 ft2
0.1
Wood
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing Solar
Below
it Ornt
In Wall Type
SpaceR-VallreR-Vale
rien
on sor
1 N
Exterior Concrete Block
- Int InsuLIVNG AREA
4 17
10 12 11
230.3 ft2
0
0 0.6
0
2 S
Exterior Concrete Block - Int InsuLIVNG AREA
4 17
10 12 11
230.3 ft2
0
0 0.6
0
3 E
Exterior Concrete Block - Int InsuKITCHEN/DI
4 11
0 10 0
110.0 ft2
0
0 0.6
0
12/13/201910:01 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7
FORM R405-2017
INPUT 5UMMARY GHE(;KLI51 REPL)K 1
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing
Solar
Below
Space
4
S
Exterior
Concrete Block - Int InsuKITCHEN/DI
4
22
0
10
0
220.0 ft2
0
0
0.6
0
5
N
Exterior
Concrete Block - Int Insul LAUNDRY
4
13
0
10
0
130.0 ft2
0
0
0.6
0
6
N
Exterior
Concrete Block - Int Insul POWDER
4
9
0
10
0
90.0 ft2
0
0
0.6
0
7
W
Exterior
Concrete Block - Int Insul POWDER
4
4
0
10
0
40.0 ft2
0
0
0.6
0
8
W
Exterior
Concrete Block - Int InsuMUD ROOM
4
4
0
10
0
40.0 ft2
0
0
0.6
0
9
S
Exterior
Concrete Block - Int Insul HALL
4
15
3
12
6
190.6 ft2
0
0
0.6
0
10
N
Exterior
Concrete Block - Int Insul HALLWAY
4
9
10
12
2
119.6 ft2
0
0
0.6
0
11
N
Exterior
Concrete Block - Int Insul BATH 2
4
16
0
10
0
160.0 ft2
0
0
0.6
0
12
W
Exterior
Concrete Block - Int Insul BATH 2
4
7
0
10
0
70.0 ft2
0
0
0.6
0
13
N
Exterior
Concrete Block - Int Insul BATH 3
4
16
0
10
0
160.0 ft2
0
0
0.6
0
14
E
Exterior
Concrete Block - Int Insul BATH 3
4
7
0
10
0
70.0 ft2
0
0
0.6
0
15
W
Exterior
Concrete Block - Int InsuBEDROOM 2
4
15
0
10
0
150.0 ft2
0
0
0.6
0
16
E
Exterior
Concrete Block - Int InsuBEDROOM 3
4
13
0
10
0
130.0 ft2
0
0
0.6
0
17
W
Exterior
Concrete Block - Int Insul CLST. 2
4
5
0
10
0
50.0 ft2
0
0
0.6
0
18
W
Exterior
Concrete Block- Int Insul TOILET
4
3
0
10
0
30.0 ft2
0
0
0.6
0
19
W
Exterior
Concrete Block - Int Insul M BATH
4
14
0
10
0
140.0 ft2
0
0
0.6
0
20
E
Exterior
Concrete Block - Int Insd1AASTERBED
4
7
0
10
0
70.0 ft2
0
0
0.6
0
21
S
Exterior
Concrete Block - Int InsLMASTERBED
4
18
0
10
0
180.0 ft2
0
0
0.6
0
22
W
Exterior
Concrete Block - Int InsU14ASTERBED
4
20
0
10
0
200.0 ft2
0
0
0.6
0
23
E
Exterior
Concrete Block - Int InsuIPET ROOM
4
8
0
10
0
80.0 ft2
0
0
0.6
0
24
S
Exterior
Concrete Block - Int InsulPET ROOM
4
7
0
10
0
70.0 ft2
0
0
0.6
0
25
W
Garage
Frame - Wood LAUNDRY
23
27
10
270.0 ft2
0
0.25 0.600000 0
DOORS
#
Omt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
N
Wood LIVNG AREA
None
.39
6
8
48 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
Wall
Overhang
#
Ornt ID
Frame Panes NFRC U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
N 1
Vinyl Low-E Single Yes
0.33
0.18
N
12.5 ft2
6 ft 0 in
0 ft 11.25
None
None
2
N 1
Vinyl Low-E Single Yes
0.33
0.18
N
36.0 ft2
6 ft 0 in
Oft 11.3 i
None
None
3
S 2
Vinyl Low-E Single Yes
0.35
0.17
N
120.0 ft2
2 ft 0 in
Oft 14.1 i
None
None
4
E 3
Vinyl Low-E Single Yes
0.35
0.17
N
48.0 ft2
16 ft 0 in
0 ft 14.12
None
None
5
S 4
Vinyl Low-E Single Yes
0.33
0.18
N
54.0 ft2
2 ft 0 in
0 ft 11.25
None
None
6
N 5
Vinyl Low-E Single Yes
0.33
0.18
N
12.3 ft2
2 ft 0 in
0 ft 11.25
None
None
7
N 6
Vinyl Low-E Single Yes
0.33
0.18
N
12.3 ft2
2 ft 0 in
0 ft 11.31
None
None
8
S 9
Vinyl Low-E Single Yes
0.33
0.18
N
54.0 ft2
2 ft 0 in
0 ft 11.3 i
None
None
9
N 10
Vinyl Low-E Single Yes
0.33
0.18
N
36.0 ft2
6 ft 0 in
0 ft 11.3 i
None
None
10
N 11
Vinyl Low-E Single Yes
0.33
0.18
N
18.0 ft2
2 ft 0 in
0 ft 11.31
None
None
11
N 13
Vinyl Low-E Single Yes
0.33
0.18
N
18.0 ft2
2 ft 0 in
0 ft 11.3 i
None
None
12
W 15
Vinyl Low-E Single Yes
0.33
0.18
N
36.0 ft2
2 ft 0 in
0 ft 11.31
None
None
1
12/13/201910:01 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7
FORM R405-2017 INPUT 15UMMAKY L;HtzUKLIS I Ktl'UK I
WINDOWS
Orientation shown is the entered, Proposed orientation.
�/ #
Wall
Ornt ID Frame Panes
NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation Int Shade
Screening
13
14
15
16
17
E 16 Vinyl Low-E Single
W 19 Vinyl Low-E Single
S 21 Vinyl Low-E Single
W 22 Vinyl Low-E Single
S 24 Vinyl Low-E Single
Yes
Yes
Yes
Yes
Yes
0.33 0.18 N 21.1 ft2 2 ft 0 in 0 ft 11.3 i None
0.33 0.18 N 12.0 ft2 2 ft 0 in 0 ft 11.3 i None
0.33 0.18 N 54.0 ft2 2 ft 0 in Oft 11.3 i None
0.33 0.18 N 25.0 ft2 2 ft 0 in 0 ft 11.3 i None
0.33 0.13 N 21.3 ft2 2 ft 0 in 0 ft 11.3 i None
None
None
None
None
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
756 ft2
756 ft2
27 ft loft 11
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000445
4335.3 238 447.6 .1685 7
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency Capacity Block
Ducts
1
2
Electric Strip Heat/
Electric Strip Heat/
None
None
COP:1 27 kBtu/hr 2
COP:1 17 kBtu/hr 1
sys#1
sys#2
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1
2
Central Unit/
Central Unit/
Split
Split
Single SEER: 17 36 kBtu/hr cfm 0.7 2
Single SEER: 17.5 25.2 kBtu/hr cfm 0.7 1
sys#1
sys#2
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Propane None
Garage
0.6 50 gal 60.9 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None None
ft2
DUCTS
/
v #
--- Supply----
Location R-Value Area
--- Return ---- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT QN RLF
HVAC #
Heat Cool
1
2
Attic 6 175 ft2
Attic 6 135 ft2
Attic
Attic
65 ft2 Default Leakage A/C (Default) c(Default) c
45 ft2 Default Leakage A/C 2 (Default) c(Default) c
1 1
2 2
12/13/2019 10:01 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
Programable Thermostat:
N
Ceiling Fans:
CoolingJan
HeatinHJan HFeb
Feb
Mar
Mar
Apr
Apr
f
May
May
Jun
ri Jun
Jul
rj Jul
AuSep
rj Au
ri Se
Oct
OctNov
Nov
Dec
Dec
H
Ventin Jan
Feb
X Mar
[X] A r
[
Ma
Jun
Jul
Aug
Se
[X] Oct X
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Heating (WD)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
Heating (WEH)
AM
65
65
65
65
65
65
65
68
68
68
68
6B
PM
68
68
68
68
68
6B
68
68
68
68
68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
LIVNG AREA
Default(8 Ibs/sq.ft.
ft2
ft
0.3
A/C 2
Default(8lbs/sq.ft.
ft2
ft
0.3
KITCHEN/DINING
Default(8 Ibslsq.ft.
ftz
ft
0.3
LAUNDRY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
POWDER
Default(8 Ibs/sq.ft.
ft2
ft
0.3
MUD ROOM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALL
Default(8 Ibs/sq.ft.
ft2
ft
0.3
TROPHY ROOM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALLWAY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST. 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST. 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
TOILET
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
W/H
Default(8 Ibs/sq.ft.
ft2
ft
0.3
A/C
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC
Default(8lbs/sq.ft.
ft2
ft
0.3
MASTERBEDROO
Default(8 Ibs/s .ft.
ft2
ft
0.3
PET ROOM
12/13/2019 10:01 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
i
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: CRIPPEN RESIDENCE Builder Name:
Street: 24909 ORANGE AVENUE Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Y
U
Owner: SCOTT CRIPPEN Jurisdiction:
w
Design Location: FL, Fort Pierce
v
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in any dropped ceiling/soffit
insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be sealed.
shall be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of insulation.
Floor framing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation shall
and cantilevered floors)
be permitted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottorr
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring a
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs.
insulated.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover plates and walls or ceilings.
a. In addition, inspection of lag walls shall be in accordance with the provisions of [CC-400.
12/13/201910:01 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 96
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
varies
3. No. of units (if multiple -family)
3. 1
4. Number of bedrooms
4. 0
13. Cooling system: Capacity
61.2
a) Split system SEER
varies
5. Is this a worst case? (yes/no)
5. No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6. 3716
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a. 0.336
b) Solar Heat Gain Coefficient (SHGC)
7b. 0.175
14. Heating system: Capacity
44.0
c) Area
7c. 590.4
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a. NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b. NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a. 0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
0.60
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2. 4.0
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131. 23.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a. 0.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11d. No
e) Multizone heating credit
f) Programmable thermostat
No
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date: , 1 hl
Address of New Home: 24909 ORANGE AVENUE City/FL Zip: FT. PIERCE, FL
12113/201910:01:19 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1