Loading...
HomeMy WebLinkAboutRevision; SHGC on Sliding Glass Doors & Energy Calcs to matchOFFICE USE ONLY: ee�� DATE FILED: REVISION FEE: �- Q PERMIT # Z9� �' 06-0 �- RECEIPT # �i YL.2 M PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982.5652 (772) 462-1553 APPLICATION FOR BUILDING PERMIRIEA(t�$10 PROJECT INFORMATION LOCATION/SITE ADD SS• o9 rv� DETAILED DESCRIPTION OF PROJECT REVISIONS: CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: BUSINESS NAME: -(a ►'n QUALIFIERS NAME: .gyp V / cD ADDRESS: 5) -7dg!- e— 64nr CITY: ACT g?JEdC'9" STATE: PHONE (DAYTIME): ME): OWNER/BUILDER INFORMATION: NAME: ADDRESS: ST. LUCIE CO CERT. #: 30 Z-• dz.l • A ZIP: -'AX: CITY: STATE: PHONE (DAYTIME: FAX: ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: STATE: PHONE (DAYTIME): SLCCC: 9123109 Revised 06130/17 ZIP: ZIP: FILE, G�L1Qi FAX: _..._. - -- - R .E C. EI V DEC 16 2019 Permitting Department St. Lucie County, FL FORM R405-2017 -�� FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: CRIPPEN RESIDENCE Builder Name: Street: 24909 ORANGE AVENUE Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: SCOTT CRIPPEN Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) t 1. New construction or existing New (From Plans) 9. Wall Types (3231.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.0 2961.00 ft2 b. Frame - Wood, Adjacent R=23.0 270.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 0 d. N/A R= ft2 10. Ceiling Types (3958.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=30.0 3958.00 ft2 6. Conditioned floor area above grade (ft2) 3716 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(590.4 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: A/C 6 175 a. U-Factor: Sgl, U=0.33 401.11 ft2 b. Sup: Attic, Ret: Attic, AH: A/C 2 6 135 SHGC: SHGC=0.16 b. U-Factor: Sgl, U=0.35 168.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.17 a. Central Unit 36.0 SEER:17.00 b. Central Unit 25.2 SEER:17.50 c. U-Factor: Sgl, U=0.33 21.33 ft2 SHGC: SHGC=0.13 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 27.0 COP:1.00 SHGC: b. Electric Strip Heat 17.0 COP:1.00 Area Weighted Average Overhang Depth: 3.711 ft. Area Weighted Average SHGC: 0.175 14. Hot water systems a. Propane Cap: 50 gallons 8. Floor Types (3716.0 sqft.) Insulation Area EF: 0.600 a. Slab -On -Grade Edge Insulation R=0.0 3716.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits None Glass/Floor Area: 0.159 Total Proposed Modified Loads: 102.17 C S PA�7�7 Total Baseline Loads: 106.81 1 hereby certify that the plans and specifications covered by Review of the plans andZHB this calculation are in compliance with the Florida Energy specifications covered by this "= Code. calculation indicates compliance �j" iiq'�e �,.��` VA with the Florida Energy Code. �n,�r'';..;.:¢ ,';•� �, O� PREPARED BY: DATE:. - IS Before construction is completed this building will be inspected for compliance with Section 553.908 ►■ I hereby certify that this building, as designed, is in compliance Florida Statutes. CAD with the Florida Energy Code. WE'f�� OWNER/AGENT• BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH5 2.4. ION �F I E COPY �'zo '9 12/13/2019 10:01 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 7 CORM R405-2017 INPUT SUMMARY CHECKLIST REPORT -; PROJECT - Title: CRIPPEN RESIDENCE Bedrooms: 0 Address Type: Street Address Building Type: User Conditioned Area: 3716 Lot # Owner Name: SCOTT CRIPPEN Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 24909 ORANGE AVEN Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 UNIT #2 1546 15460 2 UNIT #1 2170 21700 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 LIVNG AREA 667 6670 No 4 1 Yes Yes Yes 2 A/C 2 8 80 No 0 1 No Yes Yes 3 KITCHEN/DINING 556 5560 No 0 1 Yes Yes Yes 4 LAUNDRY 160 1600 No 0 1 Yes Yes Yes 5 POWDER 36 360 No 0 1 Yes Yes Yes 6 MUD ROOM 54 540 No 0 1 Yes Yes Yes 7 HALL 130 1300 No 0 1 Yes Yes Yes 8 TROPHY ROOM 411 4110 No 3 1 No Yes Yes 9 HALLWAY 148 1480 No 0 1 Yes Yes Yes 10 BATH 2 112 1120 No 0 1 Yes Yes Yes 11 BATH 3 112 1120 No 0 1 Yes Yes Yes 12 BEDROOM 2 235 2350 No 1 1 Yes Yes Yes 13 BEDROOM 3 226 2260 No 1 1 Yes Yes Yes 14 CLST.3 35 350 No 0 1 No Yes Yes 15 CLST.2 45 450 No 0 1 Yes Yes Yes 16 TOILET 24 240 No 0 1 Yes Yes Yes 17 M BATH 126 1260 No 0 1 Yes Yes Yes 18 W/H 6 60 No 0 1 No Yes Yes - 19 A/C 6 60 No 0 1 No Yes Yes 20 WIC 2 67 670 No 0 1 No Yes Yes 21 WIC 91 910 No 0 1 No Yes Yes 12113/201910:01 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT SPACES Number Name Area Volume Ktchen Occupants Bedrooms InfilID Finished Cooled Heated 22 MASTERBEDROO 412 4120 No 2 1 Yes Yes Yes 23 PET ROOM 49 490 No 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation LIVNG AREA 46 ft 0 667 ft2 ____ 0 1 0 2 Slab -On -Grade Edge Insulation A/C 2 1 ft 0 8 ft2 ____ 0 1 0 3 Slab -On -Grade Edge Insulation KITCHEN/DININ 33 ft 0 556 ft2 ____ 0 1 0 4SIab-On-Grade Edge Insulation LAUNDRY 13 ft 0 160 ft2 ____ 0 1 0 5 Slab -On -Grade Edge Insulation POWDER 13 ft 0 36 ft2 ____ 0 1 0 6 Slab -On -Grade Edge Insulation MUD ROOM 4 ft 0 54 ft2 ___- 0 1 0 7 Slab -On -Grade Edge Insulation HALL 19 ft 0 130 ft2 ____ 0 1 0 8 Slab -On -Grade Edge Insulation TROPHY ROOM 1 ft 0 411 ft2 ____ 0 1 0 9 Slab -On -Grade Edge Insulation HALLWAY 12 ft 0 148 ft2 ____ 0 1 0 10SIab-On-Grade Edge Insulation BATH 2 23 ft 0 112 ft2 ___- 0 1 0 11Slab-On-Grade Edge Insulation BATH 3 23 ft 0 112 ft2 ___- 0 1 0 12SIab-On-Grade Edge Insulation BEDROOM 2 15 ft 0 235 ft2 ___- 0 1 0 13SIab-On-Grade Edge Insulation BEDROOM 3 13 ft 0 226 ft2 _-__ 0 1 0 14SIab-On-Grade Edge Insulation CLST. 3 1 ft 0 35 ft2 -___ 0 1 0 15SIab-On-Grade Edge Insulation CLST. 2 5 ft 0 45 ft2 ____ 0 1 0 16SIab-On-Grade Edge Insulation TOILET 3 ft 0 24 ft2 _-__ 0 1 0 17SIab-On-Grade Edge Insulation M BATH 14 ft 0 126 ft2 __-_ 0 1 0 18SIab-On-Grade Edge Insulation W/H 1 ft 0 6 ft2 _--_ 0 1 0 19SIab-On-Grade Edge Insulation A/C 1 ft 0 6 ft2 ____ 0 1 0 20SIab-On-Grade Edge Insulation WIC 2 1 ft 0 67 ft2 -___ 0 1 0 21SIab-On-Grade Edge Insulation WIC 1 ft 0 91 ft2 ___- 0 1 0 22SIab-On-Grade Edge Insulation MASTERBEDRO 45 ft 0 412 ft2 -__- 0 1 0 23SIab-On-Grade Edge Insulation PET ROOM 15 ft 0 49 ft2 -___ 0 1 0 12/13/201910:01 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7 FORM R405-2017 INPUT 5UMMAKY L;Hh(:KLIS I KCPUK ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 4155 ft2 0 ft2 Light N 0.6 No 0.9 No 30 26.6 ATTIC RBS IRCC V # Type Ventilation Vent Ratio (1 in) Area 1 Full attic Unvented 0 3715 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) LIVNG AREA 0 Blown 793 ft2 0 Wood 2 Under Attic (Unvented) A/C 2 0 Blown 8 ft2 0.1 Wood 3 Under Attic (Unvented) KITCHEN/DININ 0 Blown 556 ft2 0.1 Wood 4 Under Attic (Unvented) LAUNDRY 0 Blown 160 ft2 0.1 Wood 5 Under Attic (Unvented) POWDER 0 Blown 36 ft2 0.1 Wood 6 Under Attic (Unvented) MUD ROOM 0 Blown 54 ft2 0.1 Wood 7 Under Attic (Unvented) HALL 0 Blown 20 ft2 0.1 Wood 8 Under Attic (Unvented) HALL 0 Blown 130 ft2 0 Wood 9 Under Attic (Unvented) TROPHY ROOM 0 Blown 15 ft2 0.1 Wood 10 Under Attic (Unvented) TROPHY ROOM 0 Blown 471 ft2 0 Wood 11 Under Attic (Unvented) HALLWAY 0 Blown 37 ft2 0.1 Wood 12 Under Attic (Unvented) HALLWAY 0 Blown 132 ft2 0 Wood 13 Under Attic (Unvented) BATH 2 0 Blown 112 ft2 0.1 Wood 14 Under Attic (Unvented) BATH 3 0 Blown 112 ft2 0.1 Wood 15 Under Attic (Unvented) BEDROOM 2 0 Blown 235 ft2 0.1 Wood 16 Under Attic (Unvented) BEDROOM 3 0 Blown 226 ft2 0.1 Wood 17 Under Attic (Unvented) CLST. 3 0 Blown 35 ft2 0.1 Wood 18 Under Attic (Unvented) CLST. 2 0 Blown 45 ft2 0.1 Wood 19 Under Attic (Unvented) TOILET 0 Blown 24 ft2 0.1 Wood 20 Under Attic (Unvented) M BATH 0 Blown 126 ft2 0.1 Wood 21 Under Attic (Unvented) W/H 0 Blown 6 ft2 0.1 Wood 22 Under Attic (Unvented) A/C 0 Blown 6 ft2 0.1 Wood 23 Under Attic (Unvented) WIC 2 0 Blown 67 ft2 0.1 Wood 24 Under Attic (Unvented) WIC 0 Blown 91 ft2 0.1 Wood 25 Under Attic (Unvented) MASTERBEDRO 0 Blown 412 ft2 0.1 Wood 26 Under Attic (Unvented) PET ROOM 0 Blown 49 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below it Ornt In Wall Type SpaceR-VallreR-Vale rien on sor 1 N Exterior Concrete Block - Int InsuLIVNG AREA 4 17 10 12 11 230.3 ft2 0 0 0.6 0 2 S Exterior Concrete Block - Int InsuLIVNG AREA 4 17 10 12 11 230.3 ft2 0 0 0.6 0 3 E Exterior Concrete Block - Int InsuKITCHEN/DI 4 11 0 10 0 110.0 ft2 0 0 0.6 0 12/13/201910:01 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7 FORM R405-2017 INPUT 5UMMARY GHE(;KLI51 REPL)K 1 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 4 S Exterior Concrete Block - Int InsuKITCHEN/DI 4 22 0 10 0 220.0 ft2 0 0 0.6 0 5 N Exterior Concrete Block - Int Insul LAUNDRY 4 13 0 10 0 130.0 ft2 0 0 0.6 0 6 N Exterior Concrete Block - Int Insul POWDER 4 9 0 10 0 90.0 ft2 0 0 0.6 0 7 W Exterior Concrete Block - Int Insul POWDER 4 4 0 10 0 40.0 ft2 0 0 0.6 0 8 W Exterior Concrete Block - Int InsuMUD ROOM 4 4 0 10 0 40.0 ft2 0 0 0.6 0 9 S Exterior Concrete Block - Int Insul HALL 4 15 3 12 6 190.6 ft2 0 0 0.6 0 10 N Exterior Concrete Block - Int Insul HALLWAY 4 9 10 12 2 119.6 ft2 0 0 0.6 0 11 N Exterior Concrete Block - Int Insul BATH 2 4 16 0 10 0 160.0 ft2 0 0 0.6 0 12 W Exterior Concrete Block - Int Insul BATH 2 4 7 0 10 0 70.0 ft2 0 0 0.6 0 13 N Exterior Concrete Block - Int Insul BATH 3 4 16 0 10 0 160.0 ft2 0 0 0.6 0 14 E Exterior Concrete Block - Int Insul BATH 3 4 7 0 10 0 70.0 ft2 0 0 0.6 0 15 W Exterior Concrete Block - Int InsuBEDROOM 2 4 15 0 10 0 150.0 ft2 0 0 0.6 0 16 E Exterior Concrete Block - Int InsuBEDROOM 3 4 13 0 10 0 130.0 ft2 0 0 0.6 0 17 W Exterior Concrete Block - Int Insul CLST. 2 4 5 0 10 0 50.0 ft2 0 0 0.6 0 18 W Exterior Concrete Block- Int Insul TOILET 4 3 0 10 0 30.0 ft2 0 0 0.6 0 19 W Exterior Concrete Block - Int Insul M BATH 4 14 0 10 0 140.0 ft2 0 0 0.6 0 20 E Exterior Concrete Block - Int Insd1AASTERBED 4 7 0 10 0 70.0 ft2 0 0 0.6 0 21 S Exterior Concrete Block - Int InsLMASTERBED 4 18 0 10 0 180.0 ft2 0 0 0.6 0 22 W Exterior Concrete Block - Int InsU14ASTERBED 4 20 0 10 0 200.0 ft2 0 0 0.6 0 23 E Exterior Concrete Block - Int InsuIPET ROOM 4 8 0 10 0 80.0 ft2 0 0 0.6 0 24 S Exterior Concrete Block - Int InsulPET ROOM 4 7 0 10 0 70.0 ft2 0 0 0.6 0 25 W Garage Frame - Wood LAUNDRY 23 27 10 270.0 ft2 0 0.25 0.600000 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Wood LIVNG AREA None .39 6 8 48 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Single Yes 0.33 0.18 N 12.5 ft2 6 ft 0 in 0 ft 11.25 None None 2 N 1 Vinyl Low-E Single Yes 0.33 0.18 N 36.0 ft2 6 ft 0 in Oft 11.3 i None None 3 S 2 Vinyl Low-E Single Yes 0.35 0.17 N 120.0 ft2 2 ft 0 in Oft 14.1 i None None 4 E 3 Vinyl Low-E Single Yes 0.35 0.17 N 48.0 ft2 16 ft 0 in 0 ft 14.12 None None 5 S 4 Vinyl Low-E Single Yes 0.33 0.18 N 54.0 ft2 2 ft 0 in 0 ft 11.25 None None 6 N 5 Vinyl Low-E Single Yes 0.33 0.18 N 12.3 ft2 2 ft 0 in 0 ft 11.25 None None 7 N 6 Vinyl Low-E Single Yes 0.33 0.18 N 12.3 ft2 2 ft 0 in 0 ft 11.31 None None 8 S 9 Vinyl Low-E Single Yes 0.33 0.18 N 54.0 ft2 2 ft 0 in 0 ft 11.3 i None None 9 N 10 Vinyl Low-E Single Yes 0.33 0.18 N 36.0 ft2 6 ft 0 in 0 ft 11.3 i None None 10 N 11 Vinyl Low-E Single Yes 0.33 0.18 N 18.0 ft2 2 ft 0 in 0 ft 11.31 None None 11 N 13 Vinyl Low-E Single Yes 0.33 0.18 N 18.0 ft2 2 ft 0 in 0 ft 11.3 i None None 12 W 15 Vinyl Low-E Single Yes 0.33 0.18 N 36.0 ft2 2 ft 0 in 0 ft 11.31 None None 1 12/13/201910:01 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7 FORM R405-2017 INPUT 15UMMAKY L;HtzUKLIS I Ktl'UK I WINDOWS Orientation shown is the entered, Proposed orientation. �/ # Wall Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 13 14 15 16 17 E 16 Vinyl Low-E Single W 19 Vinyl Low-E Single S 21 Vinyl Low-E Single W 22 Vinyl Low-E Single S 24 Vinyl Low-E Single Yes Yes Yes Yes Yes 0.33 0.18 N 21.1 ft2 2 ft 0 in 0 ft 11.3 i None 0.33 0.18 N 12.0 ft2 2 ft 0 in 0 ft 11.3 i None 0.33 0.18 N 54.0 ft2 2 ft 0 in Oft 11.3 i None 0.33 0.18 N 25.0 ft2 2 ft 0 in 0 ft 11.3 i None 0.33 0.13 N 21.3 ft2 2 ft 0 in 0 ft 11.3 i None None None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 756 ft2 756 ft2 27 ft loft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000445 4335.3 238 447.6 .1685 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 2 Electric Strip Heat/ Electric Strip Heat/ None None COP:1 27 kBtu/hr 2 COP:1 17 kBtu/hr 1 sys#1 sys#2 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 2 Central Unit/ Central Unit/ Split Split Single SEER: 17 36 kBtu/hr cfm 0.7 2 Single SEER: 17.5 25.2 kBtu/hr cfm 0.7 1 sys#1 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Propane None Garage 0.6 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / v # --- Supply---- Location R-Value Area --- Return ---- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 2 Attic 6 175 ft2 Attic 6 135 ft2 Attic Attic 65 ft2 Default Leakage A/C (Default) c(Default) c 45 ft2 Default Leakage A/C 2 (Default) c(Default) c 1 1 2 2 12/13/2019 10:01 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat: N Ceiling Fans: CoolingJan HeatinHJan HFeb Feb Mar Mar Apr Apr f May May Jun ri Jun Jul rj Jul AuSep rj Au ri Se Oct OctNov Nov Dec Dec H Ventin Jan Feb X Mar [X] A r [ Ma Jun Jul Aug Se [X] Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 6B PM 68 68 68 68 68 6B 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 LIVNG AREA Default(8 Ibs/sq.ft. ft2 ft 0.3 A/C 2 Default(8lbs/sq.ft. ft2 ft 0.3 KITCHEN/DINING Default(8 Ibslsq.ft. ftz ft 0.3 LAUNDRY Default(8 Ibs/sq.ft. ft2 ft 0.3 POWDER Default(8 Ibs/sq.ft. ft2 ft 0.3 MUD ROOM Default(8 Ibs/sq.ft. ft2 ft 0.3 HALL Default(8 Ibs/sq.ft. ft2 ft 0.3 TROPHY ROOM Default(8 Ibs/sq.ft. ft2 ft 0.3 HALLWAY Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST. 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST. 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 TOILET Default(8 Ibs/sq.ft. ft2 ft 0.3 M BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 W/H Default(8 Ibs/sq.ft. ft2 ft 0.3 A/C Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC Default(8lbs/sq.ft. ft2 ft 0.3 MASTERBEDROO Default(8 Ibs/s .ft. ft2 ft 0.3 PET ROOM 12/13/2019 10:01 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA i TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: CRIPPEN RESIDENCE Builder Name: Street: 24909 ORANGE AVENUE Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y U Owner: SCOTT CRIPPEN Jurisdiction: w Design Location: FL, Fort Pierce v COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottorr to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring a plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection of lag walls shall be in accordance with the provisions of [CC-400. 12/13/201910:01 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location varies 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 0 13. Cooling system: Capacity 61.2 a) Split system SEER varies 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 3716 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.336 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.175 14. Heating system: Capacity 44.0 c) Area 7c. 590.4 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF 0.60 A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.0 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 23.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 0.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: , 1 hl Address of New Home: 24909 ORANGE AVENUE City/FL Zip: FT. PIERCE, FL 12113/201910:01:19 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1