Loading...
HomeMy WebLinkAboutEnergy Coder Whole Building Performance Method for Commercial Buildings Form 40OA-97 ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs j FLA/COM-97 Version 2.2 PROJECT NAME -PGA EDUCATIONAL CENTER ADDRESS:' 8555 COMMERCE CENTER DR.-S OWNER: _PGA AGENT: BUILDING TYPE: _Service Establishments_ CONSTRUCTION CONDITION: New construction LONESIGN COMPLETION: Finished Building DITIONED FLOOR AREA: _20956 . TONNAGE OF EQUIPMENT PER SYSTEM: _ COMPLIANCE CALCULATION: PERMITTING OFFICE: _Port St. Lucie CLIMATE ZONE: 6 PERMIT NO: JURISDICTION NO: 661200 .e METHOD A DESIGN CRITERIA RESULT ----------------- -------------- ------ A. WHOLE BUILDING 37.00 100.00 PASSES PRESCRIPTIVE REQUIREMENTS: LIGHTING LIGHTING CONTROL REQUIREMENTS PASSES HVAC EQUIPMENT COOLING EQUIPMENT 1. EER 12.00 8.50 PASSES IPLV 12.00 7.50 PASSES 2. EER 12.00 8.90 PASSES IPLV 12.00 8.30 PASSES 3. EER 12.00 8.90 PASSES IPLV 12.00 8.30 PASSES 4. EER 12.00 8.50 PASSES IPLV 12.00 7.50 PASSES 5. SEER 12.00 10.00 PASSES 6. SEER 12.00 10.00 PASSES 7. SEER 12.00 10.00 PASSES 8. SEER 12.00 10.00 PASSES 9. EER 12.00 8.50 PASSES IPLV 12.00 7.50 PASSES HEATING EQUIPMENT 1. Et 12.00 N/A 2. Et 12.00 N/A 3. Et 12.00 N/A ti4. Et 12.00 N/A 5. Et 12.00 N/A 6. Et 12.00 N/A - 7. Et 12.00 N/A 8. Et 12.00 N/A 9. Et 12.00 N/A ' AIR DISTRIBUTION SYSTEM INSULATION REQUIREMENTS 1. With Insulated Roof 6.00 4.20 PASSES 2. With Insulated Roof 6.00 4.20 PASSES 3. With Insulated Roof 6.00 4.20 PASSES 4. With Insulated Roof 6.00 4.20 PASSES 5. With Insulated Roof 6.00 4.20 PASSES 6. With Insulated Roof 6.00 4.20 PASSES . 7.1With Insulated Roof 6.00 4.20 PASSES 8. With Insulated Roof 6.00 4.20 PASSES 9.. With Insulated Roof 6.00 4.20 PASSES . REHEAT SYSTEM TYPES USED NO REHEAT SYSTEM is USED WATER HEATING EQUIPMENT 1. EF 20.00 0.90 PASSES PIPING INSULATION REQUIREMENTS 1. ---------------------------------------------------------------------------- Non -Circulating 2.00 1.00 PASSES COMPLIANCE CERTIFICATION: I hereby certify that the plans and specifications covered by this cal - lation are in complian e- h e Florida Energy c .o e. PREPARED BY: DATE: I hereby certify that this building is in compliance with the Florida Energy Efficiency Code. OWNER/AGENT: DATE: Review of the plans and specifica- tions covered by this calculation indicates compliance with the Florida Energy Efficiency Code. Before construction is completed, this building will be inspected for compliance in accordance with Section 553.908, Florida Statutes. BUILDING OFFICIAL: DATE: I hereby certify(*) that the system design is in compliance with the Florida Energy Efficiency Code. SYSTEM DESIGNER REGISTRATION/STATE ARCHITECT : MECHANICAL: PLUMBING ELECTRICAL: LIGHTING . (*) Signature is required where Florida law requires design to be performed by registered design professionals. Typed names and registration numbers may be used where all relevant information is contained on signed/sealed plans. ---------------------------------------------------------------------------- ---------------------------------------------------------------------------- BUILDING ENVELOPE SYSTEMS COMPLIANCE CHECK 401.------GLAZING--ZONE 1------------------------------------------------ v- Elevation --------- Type --------------- U ---- ---- SC ---- VLT Shading -------------- Area(Sgft) ---------- North Commercial 1.31 .80 .20 None 0 South Commercial 1.31 .80 .20 None 0 East Commercial 1.31 .80 .20 None 0 'kest Commercial 1.31 .80 .20 None 0 Total Glass Area in Zone 1 = 0 401------- GLAZING --ZONE 2------------------------------------------------ v- Elevation Type U SC VLT Shading Area(Sgft) --------- North --------------- Commercial ---- ---- 1.31 ---- .80 .20 -------------- None ---------- 0 South Commercial 1.31 .80 .20 None 136 5ast Commercial 1.31 .80 .20 None 0 West Commercial 1.31 .80 .20 None 0 Total Glass Area in Zone 2 = 136 401------- GLAZING --ZONE 3------------------------------------------------ v- Elevation Type U SC VLT Shading Area(Sgft) --------- North --------------- Commercial ---- ---- 1.31 ---- .80 .20 -------------- None ---------- 0 South Commercial 1.31 .80 .20 None 0 East Commercial 1.31 .80 .20 None 0 West Commercial 1.31 .80 .20 None 0 Total Glass Area in Zone 3 = 0 401.------GLAZING--ZONE 4------------------------------------------------ v- Elevation Type U SC VLT Shading Area(Sgft) --------- North --------------- Commercial ---- ---- 1.31 ---- .80 .20 -------------- None ---------- 0 South Commercial 1.31 .80 .20 None 0 East Commercial 1.31 .80 .20 None 0 West Commercial 1.31 .80 .20 None 0 Total Glass Area in Zone 4 = 0 401.------GLAZING--ZONE 5------------------------------------------------ v- Elevation --------- Type --------------- U ---- ---- SC ---- VLT Shading -------------- Area(Sgft) ---------- North Commercial 1.31 .80 .20 None 0 South Commercial 1.31 .80 .20 None 0 East Commercial 1.31 .80 .20 None 0 West Commercial 1.31 .80 .20 None 0 Total Glass Area in Zone 5 = 0 401.------GLAZING--ZONE 6------------------------------------------------ v- Elevation --------- Type U ---- SC ---- VLT Shading -------------- Area(Sgft) ---------- North --------------- Commercial ---- 1.31 .80 .20 None 0 South Commercial 1.31 .80 .20 None 0 East~ Commercial 1.31 .80 .20 None 0 .West Commercial 1.31 .80 .20 None 0 Total Glass Area in Zone 6 = 0 401.------GLAZING--ZONE 7------------------------------------------------ v- Elevation ---------- Type --------------- U ---- ---- SC ---- VLT Shading -------------- Area(Sgft) ---------- North Commercial 1.31 .80 .20 None 0 South Commercial 1.31 .80 .20 None 0 East Commercial 1.31 .80 .20 None 0 West Commercial 1.31 .80 .20 None 0 Total Glass Area in Zone 7 = 01 401.------GLAZING--ZONE 8------------------------------------------------ v- Elevation Type U SC VLT ---- ---- ---- Shading -------------- Area(Sgft) ---------- --------- North --------------- Commercial 1.31 .80 .20 None 0 South Commercial 1.31 .80 .20 None 0 East Commercial 1.31 .80 .20 None 0 West Commercial 1.31 .80 .20 None 0 • Total Glass Area in Zone 8 = 0 '401.------GLAZING--ZONE 9------------------------------------------------ v- Elevation Type --------------- U SC VLT ---- ---- ---- Shading -------------- Area(Sgft) ---------- --------- North Commercial 1.31 -.80 .20 None 0 South Commercial 1.31 .80 .20 None 0 East Commercial 1.31 .80 .20 None 48 West Commercial 1.31 .80 .20 None 0 Total Glass Area in Zone 9 = 48 Total Glass Area = 184 402.------WALLS--ZONE 1------------------------------------------------ --- Elevation Type U Insul ----- ------- R Gross(Sgft) ----------- --------- North -------------------------------- 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 5 0 South 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 5 1152 East 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 5 0 West 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 5 1836 Total Wall Area in Zone 1 = 2988 402.------WALLS--ZONE 2------------------------------------------------ --- Elevation Type U Insul ------- R Gross(Sgft) ----------- --------- North -------------------------------- 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp ----- 0.151 5 0 South 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 5 170 East 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 5 0 West 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 5 0 Total Wall Area in Zone 2 = 170 402.------WALLS--ZONE 3------------------------------------------------ --- Elevation Type U Insul R Gross(Sgft) --------- North -------------------------------- 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp ----- ------- 0.151 5 ----------- 0 South 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 5 550 East 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 5 340 West 811CMU/3/411ISO Btwn 24"oc/5/8"Gyp 0.151 5 0 Total Wall Area in Zone 3 = 890 402.------WALLS--ZONE 4------------------------------------------------ --- Elevation Type U Insul R Gross(Sgft) --------- North -------------------------------- 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp ----- ------- 0.151 5 ----------- 370 .South 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 5 0 East 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 5 340 West 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 5 0 Total Wall Area in Zone 4 = 710 402.: ----- WALLS --ZONE 5------------------------------------------------ --- Elevation Type U Insul R Gross(Sgft) --------- North -------------------------------- 8"CMU/3•/4"ISO Btwn 24"oc/5/8"Gyp ----- ------- 0.151 5 ----------- 500 South 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 5 0 East 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 5 0 West 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 5 170 Total Wall Area in Zone 5 = 670 I 402.------WALLS--ZONE 6 ------------------------------------------------ Elevation Type U Insul R Gross(Sgft) ----------- --------- North -------------------------------- 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp ----- ------- 0.151 5 0 South 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 5 0 East 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 5 0 West 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 5 0 Total Wall Area in Zone 6 = 0 402-------- WALLS --ZONE 7 ------------------------------------------------ .tlevation Type U Insul ------- R Gross(Sgft) ----------- --------- North -------------------------------- 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp ----- 0.151 5 360 South 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 5 0 East 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 5 360 West 811CMU/3/411ISO Btwn 24"oc/5/8"Gyp 0.151 5 470 Total Wall Area in Zone 7 = 1190 4,,02.------WALLS--ZONE 8 ------------------------------------------------ Elevation Type U Insul R Gross(Sgft) ----------- --------- North -------------------------------- 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp ----- ------- 0.151 5 320 South 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 5 100 East 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 5 200 West 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 5 240 Total Wall Area in Zone 8 = 860 402.------WALLS--ZONE 9 ------------------------------------------------ Elevation Type U Insul R Gross(Sgft) --------- North -------------------------------- 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp ----- ------- 0.151 5 ----------- 240 South 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 5 300 East 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 5 450 West 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 5 0 Total Wall Area in Zone 9 = 990 Total Gross Wall Area = 8468 403.------DOORS--ZONE 1 ------------------------------------------------ Elevation Type U Area(Sgft) --------- North ------------------------------------------ 1-3/8 Wood Door -Solid core flush ----- 0.39 ---------- 21 South 1-3/8 Wood Door -Solid core flush 0.39 0 East 1-3/8 Wood Door -Solid core flush 0.39 0 West 1-3/8 Wood Door -Solid core flush 0.39 0 Total Door Area in Zone 1 = 21 403------- DOORS --ZONE 2 ------------------------------------------------ Elevation Type U Area(Sgft) --------- North ------------------------------------------ 1-3/8 Wood Door -Solid core flush ----- 0.39 ---------- 0 South 1-3/8 Wood Door -Solid core flush 0.39 136 ,_,East 1-3/8 Wood Door -Solid core flush 0.39 0 West 1-3/8 Wood Door -Solid core flush 0.39 0 Total Door Area in Zone 2 = 136 .403.------DOORS--ZONE 3 ------------------------------------------------ Elevation Type U Area(Sgft) --------- North ------------------------------------------ 1-3/8 Wood Door -Solid core flush ----- 0.39 ---------- 0 South 1-3/8 Wood Door -Solid core flush 0.39 0 East 1-3/8 Wood Door -Solid core flush 0.39 0 West 1-3/8 Wood Door -Solid core flush 0.39 0 Total Door Area in Zone 3 = 0 403.------DOORS--ZONE 4------------------------------------------------ Elevation Type U ----- Area(Sgft) ---------- --------- North ------------------------------------------ 1-3/8 Wood Door -Solid core flush 0.39 0 South 1-3/8 Wood Door -Solid core flush 0.39 0 East 1-3/8 Wood Door -Solid core flush 0.39 0 West 1-3/8 Wood Door -Solid core flush 0.39 0 Total Door Area in Zone 4 = 0 403.--_ --- DOORS --ZONE 5 ------------------------------------------------ Elevation Type U Area(Sgft) I--------- ------------------------------------------ ----- ---------- North 1-3/8 Wood Door -Solid core flush 0.39 0 South 1-3/8 Wood Door -Solid core flush 0.39 0 East 1-3/8 Wood Door -Solid core flush 0.39 0 West 1-3/8 Wood Door -Solid core flush 0.39 21 Total Door Area in Zone 5 = 21 403.------DOORS--ZONE 6------------------------------------------------ Flevation Type U Area (Sgft) --------- North ------------------------------------------ 1-3/8 Wood Door -Solid core flush ----- 0.39 ---------- 0 South 1-3/8 Wood Door -Solid core flush 0.39 0 East 1-3/8 Wood Door -Solid core flush 0.39 0 West 1-3/8 Wood Door -Solid core flush 0.39 0 Total Door Area in Zone 6 = 0 403.------DOORS--ZONE 7 ------------------------------------------------ Elevation Type U Area(Sgft) --------- North ------------------------------------------ 1-3/8 Wood Door -Solid core flush ----- 0.39 ---------- 0 South 1-3/8 Wood Door -Solid core flush 0.39 0 East 1-3/8 Wood Door -Solid core flush 0.39 0 West 1-3/8 Wood Door -Solid core flush 0.39 0 Total Door Area in Zone 7 = 0 403.------DOORS--ZONE 8 ------------------------------------------------ Elevation Type U Area(Sgft) --------- North ------------------------------------------ 1-3/8 Wood Door -Solid core flush ----- 0.39 ---------- 0 South 1-3/8 Wood Door -Solid core flush 0.39 0 East 1-3/8 Wood Door -Solid core flush 0.39 0 West 1-3/8 Wood Door -Solid core flush 0.39 0 Total Door Area in Zone 8 = 0 403.------DOORS--ZONE 9 ------------------------------------------------ Elevation Type U Area(Sgft) --------- North ------------------------------------------ 1-3/8 Wood Door -Solid core flush ----- 0.39 ---------- 0 South 1-3/8 Wood Door -Solid core flush 0.39 0 East 1-3/8 Wood Door -Solid core flush 0.39 96 West 1-3/8 Wood Door -Solid core flush 0.39 0 Total Door Area in Zone 9 = 96 Total Door Area 274 404------- ROOFS --ZONE 1 ------------------------------------------------ ,= .Type Color U Insul R Area(Sgft) ------------------------------------ Built-up Gravel/2" ISO/Mtl Deck ------ ----- Medium ------- .065 14 ---------- 2578 Total Roof Area in Zone 1 = 2578 4-04------- ROOFS --ZONE 2 ------------------------------------------------ Type Color U Insul R Area(Sgft) ------------------------------------ Built-up Gravel/2" ISO/Mtl Deck ------ ----- Medium ------- .065 14 ---------- 2578 Total Roof Area in Zone 2 = 2578 404.------ROOFS--ZONE 3 ------------------------------------------------ Type Color ------ ----- U Insul R ------- Area(Sgft) ---------- ------------------------------------ Built-up Gravel/2" ISO/Mtl Deck Medium .065 14 2578 Total Roof Area in Zone 3 = 2578 404: ------ ROOFS --ZONE 4 ------------------------------------------------ Type Color U Insul R Area(Sgft) ----------i ----------------------------------- Built-up Gravel/2" ISO/Mtl Deck ------ ----- Medium ------- .065 14 3202' Total Roof Area in Zone 4 = 3202 404------- ROOFS --ZONE 5------------------------------------------------' Type Color U Insul R ------- Area(Sgft) ---------- ------------------------------------ Built-up Gravel/2" ISO/Mtl Deck ------ ----- Medium .065 14 2036 Total Roof Area in Zone 5 = 2036 404.------ROOFS--ZONE 6 ------------------------------------------------ Type Color U Insul R Area (Sgft ) ---------- ------------------------------------ Built-up Gravel/2" ISO/Mtl Deck ------ ----- Medium ------- .065 14 2036 • Total Roof Area in Zone 6 = 2036 404.------ROOFS--ZONE 7 ------------------------------------------------ Type Color U Insul R ------- Area(Sgft) ---------- ------------------------------------ Built-up Gravel/2" ISO/Mtl Deck ------ ----- Medium .065 14 1067 Total Roof Area in Zone 7 = 1067 404------- ROOFS --ZONE 8 ------------------------------------------------ Type Color U Insul R Area(Sgft) ---------- ------------------------------------ Built-up Gravel/2" ISO/Mtl Deck ------ ----- Medium ------- .065 14 1456 Total Roof Area in Zone 8 = 1456 404------- ROOFS --ZONE 9 ------------------------------------------------ Type Color U Insul R ------- Area(Sgft) ---------- ------------------------------------ Built-up Gravel/2" ISO/Mtl Deck ------ ----- Medium .065 14 3431 Total Roof Area in Zone 9 = 3431 Total Roof Area = 20962 405.------FLOORS-ZONE I ------------------------------------------------ Type Insul R ------- Area(Sgft) ---------- ------------------------------------------------ Slab on Grade/Uninsulated 2 2578 Total Floor Area in Zone 1 = 2578 405.------FLOORS-ZONE 2 ------------------------------------------------ Type Insul R Area(Sgft) ------------------------------------------------ Slab on Grade/Uninsulated ------- 2 ---------- 2578 Total Floor Area in Zone 2 = 2578 .405.------FLOORS-ZONE 3 ------------------------------------------------ Type, Insul R Area(Sgft) ------------------------------------------------ -Slab on Grade/Uninsulated ------- 2 ---------- 2578 - Total Floor Area in Zone 3 = 2578 405.------FLOORS-ZONE 4 ------------------------------------------------ Type =----------------------------------------------- Insul R Area (Sgft) Slab on Grade/Uninsulated ------- 2 ---------- 3202 Total Floor Area in Zone 4 = 3202 405.------FLOORS-ZONE 5 ------------------------------------------------ Type Insul R Area(Sgft) ------------------------------------ Slab on Grade/Uninsulated ------ - - - - - -- - - - - -- 2 ---- - - - - - - 2036 Total Floor Area in Zone 5 = 2036 405.------FLOORS-ZONE 6 ------------------------------------------------ Type ,, _--.--------------------------------------------- Insul ------- R Area(Sgft) ---------- Slab on Grade/Uninsulated 2 2036 Total Floor Area in Zone 6 = 2036 405-------- FLOORS -ZONE 7 ------------------------------------------------ Type Insul R Area(Sgft) ------------------------------------------------ Slab on Grade/Uninsulated ------- 2 ---------- 1067 Total Floor Area in Zone 7 = 1067 405.------FLOORS-ZONE 8--------- --------------------------------------- Type Insul ------- R Area(Sgft) ---------- ------------------------------------------------ Slab on Grade/Uninsulated 2 1459 Total Floor Area in Zone 8 = 1459 405.------FLOORS-ZONE 9 ------------------------------------------------ Type Insul ------- R Area (Sqf t ) ---------- ------------------------------------------------ Slab on Grade/Uninsulated 2 3431 Total Floor Area in Zone 9 = 3431 Total Floor Area = 20965 406.------INFILTRATION -------------------------------------------------- ICHECK Infiltration Criteria in 406.1.ABCD have been met. MECHANICAL SYSTEMS CHECK HVAC load sizing has been performed. (407.1.ABCD) 1 407------- COOLING SYSTEMS ----------------------------------------------- Type No Efficiency IPLV ------------------- Tons 1. ---------------------------- Air Cooled ( >= 65,000 Btu/h --- 1 ---------- 12 12 60.00 2. Air Cooled ( >= 65,000 Btu/h 1 12 12 6.35 3. Air Cooled ( >= 65,000 Btu/h 3 12 12 6.61 4. Air Cooled ( >= 65,000 Btu/h 1 12 12 19.42 5. Split System 1 12 12 2.42 6. Split System 1 12 12 3.96 7. Split System 1 12 12 4.83 8. Split System 1 12 12 3.38 9. Air Cooled ( >= 65,000 Btu/h 1 12 12 13.70 408.------HEATING SYSTEMS ----------------------------------------------- Type No Efficiency ------------------------ BTU/hr 1. -------------------------------- Electric Resistance --- 1 12 90000 2. Electric Resistance 1 12 15200 • 3. Electric Resistance 3 12 10600 4. Klectric Resistance 1 12 24950 5. Electric Resistance 1 12 8000 6. Electric Resistance 1 12 10000 '7. Electric Resistance 1 12 10000 8. Electric Resistance 1 12 10000 9. Electric Resistance 1 12 18400 409.------VENTILATION --------------------------------------------------- ICHECK - Ventilation Criteria in 409.1.ABCD have been met. 410------ AIR DISTRIBUTION SYSTEM---------------------------------------- CHECK- Duct --------------------------- sizing and design have been ------------------------------ performed. (410.1.ABCD) ---- .AHU Type Duct Location R-value 1. ----------------------------------- Air Conditioners ---------------------- With Insulated Roof ------- 6 -2, Air Conditioners With Insulated Roof 6 '3. Air Conditioners With Insulated Roof 6 4. Air Conditioners With Insulated Roof 6 5. Air Conditioners With Insulated Roof 6 6. Air Conditioners With Insulated Roof 6 7. Air Conditioners With Insulated Roof 6 8. Air Conditioners With Insulated Roof 6 9. Air Conditioners With Insulated Roof 6 CHECK ---------------------------------------------------------- Testing and balancing will be performed. (410.1.ABCD) ---- 411.-----PUMPS AND PIPING -ZONE ----------------------------------------- Basic prescriptive requirements in 411.1.ABCD have been met. PLUMBING SYSTEMS 411.-----PUMPS AND PIPING -ZONE Type ------------------------ 1. Non -Circulating 411.-----PUMPS AND PIPING -ZONE Type ------------------------ 1. Non -Circulating 411------ PUMPS AND PIPING -ZONE Type ------------------------ 1. Non -Circulating 411.-----PUMPS AND PIPING -ZONE Type ------------------------ 1. Non -Circulating 411.-----PUMPS AND PIPING -ZONE Type ------------------------ 1. Non -Circulating 411.-----PUMPS AND PIPING -ZONE Type ------------------------ 1. Non -Circulating 411.-- --- PUMPS AND PIPING -ZONE Type ------------------------ 1. Non -Circulating 411.-----PUMPS AND PIPING -ZONE Type ------------------------ 1. Non -Circulating 4i1.-----PUMPS AND PIPING -ZONE Type 1--------------------------------------- R-value/in Diameter Thickness --------------------------- 4 .75 2 2 --------------------------------------- R-value/in Diameter Thickness --------------------------- 4 .75 2 3 --------------------------------------- R-value/in Diameter Thickness --------------------------- 4 .75 2 4------------------------------ --------- R-value/in Diameter Thickness --------------------------- 4 .75 2 5 --------------------------------------- R-value/in Diameter Thickness --------------------------- 4 .75 2 6 --------------------------------------- R-value/in Diameter Thickness --------------------------- 4 .75 2 7 --------------------------------------- R-value/in Diameter Thickness --------------------------- 4 .75 2 8 --------------------------------------- R-value/in Diameter Thickness --------------------------- 4 .75 2 9 --------------------------------------- R-value/in Diameter Thickness 1. Non -Circulating 4 .75 2 412.-----WATER HEATING SYSTEMS -ZONE 1 ---------------------------------- Type ------------------------ Efficiency StandbyLoss ------------------------------ InputRate ---------- Gallons • 1.• <=12 kW 20 0 200 20 412.-----WATER HEATING SYSTEMS -ZONE 2 ---------------------------------- Type •------------------------ Efficiency StandbyLoss ------------------------------ InputRate ---------- Gallons 412.-----WATER HEATING SYSTEMS -ZONE 3 ---------------------------------- Type ------------------------ Efficiency StandbyLoss ------------------------------ InputRate ---------- Gallons 412.-----WATER HEATING SYSTEMS -ZONE 4 ---------------------------------- Type ------------------------ Efficiency StandbyLoss ------------------------------ InputRate ---------- Gallons 412.-----WATER HEATING SYSTEMS -ZONE 5---------------------------------- Type ------------------------ Efficiency StandbyLoss ------------------------------ InputRate ---------- Gallons 412.-----WATER HEATING SYSTEMS -ZONE 6---------------------------------- Type ------------------------ Efficiency StandbyLoss ------------------------------ InputRate ---------- Gallons 412.-----WATER HEATING SYSTEMS -ZONE 7 ---------------------------------- Type ------------------------ Efficiency StandbyLoss ------------------------------ InputRate ---------- Gallons 412------ WATER HEATING SYSTEMS -ZONE 8---------------------------------- Type ------------------------ Efficiency StandbyLoss ------------------------------ InputRate ---------- Gallons 412.-----WATER HEATING SYSTEMS -ZONE 9---------------------------------- Type ------------------------ Efficiency StandbyLoss ------------------------------ InputRate ---------- Gallons ELECTRICAL SYSTEMS CHECK 413.-----ELECTRICAL POWER DISTRIBUTION---------------------------- ----- Metering criteria in 413.1.ABCD have been met. 414.-----MOTORS --------------------------------------------------- ----- Motor efficiencies in 414.1.ABCD have been met. 415,.-----LIGHTING SYSTEMS -ZONE 1 --------------------------------------- Space Type No Control Type 1 No Control Type 2 No Watts Area(Sgft) ---------- ----------------- Classroom/ 1 On/Off ----------------- 2 None --- 0 ------ 500 ---------- 2578 Total Watts for Zone 1 = 500 Total Area for Zone 1 = 2578 415.-----LIGHTING SYSTEMS -ZONE 2 --------------------------------------- Space Type No Control Type 1 No Control Type 2 No Watts Area(Sgft) ---------- -------=--------- ,_,Corridor 1 On/Off ----------------- 2 None --- 0 ------ 500 ---------- 2578 Total Watts for Zone 2 = 500 Total Area for Zone 2 = 2578 415.-----LIGHTING SYSTEMS -ZONE 3--------------------------------------- Space„Type No Control Type 1 No Control Type 2 No Watts Area(Sgft) ---------- ----------------- Classroom/ 1 On/Off ----------------- 2 None --- 0 ------ 500 ---------- 2578 Total Watts for Zone 3 = 500 Total Area for Zone 3 = 2578 415.-----LIGHTING SYSTEMS -ZONE 4 --------------------------------------- Space Type No Control Type 1 No Control Type 2 No Watts Area(Sgft) ---------- ----------------- ----------------- --- ---------------- Classroom/ 1 On/Off 415.-----LIGHTING SYSTEMS -ZONE Space Type No Control Type 1 ---------- --- -------------- Material H 1 On/Off 415.-----LIGHTING SYSTEMS -ZONE Space Type No Control Type 1 ---------- --- -------------- Toilet and 1 On/Off 415.-----LIGHTING SYSTEMS -ZONE Space Type No Control Type 1 ---------- --- -------------- Reading, T 1 On/Off 415.-----LIGHTING SYSTEMS -ZONE Space Type No Control Type 1 ---------- --- -------------- Recreation 1 On/Off 415.-----LIGHTING SYSTEMS -ZONE Space Type No Control Type 1 ---------- --- -------------- Laboratory 1 On/Off 2 None 0 500 3002 Total Watts for Zone 4 = 500 Total Area for Zone 4 = 3002 5 --------------------------------------- No Control Type 2 No Watts Area(Sgft) ----------------- --- ---------------- 2 None 0 500 2036 Total Watts for Zone 5 = 500 Total Area for Zone 5 = 2036 6 --------------------------------------- No Control Type 2 No Watts Area(Sgft) ----------------- --- --------------- 2 None 0 500 2036 Total Watts for Zone 6 = 500 Total Area for Zone 6 = 2036 7 --------------------------------------- No Control Type 2 No Watts Area(Sgft) ----------------- --- ---------------- 2 None 0 500 1067 Total Watts for Zone 7 = 500 Total Area for Zone 7 = 1067 8 --------------------------------------- No Control Type 2 No Watts Area(Sgft) ----------------- --- ---------------- 2 None 0 500 1459 Total Watts for Zone 8 = 500 Total Area for Zone 8 = 1459 9 --------------------------------------- No Control Type 2 No Watts Area(Sgft) ----------------- --- ---------------- 2 None 0 500 3431 Total Watts for Zone 9 = 500 Total Area for Zone 9 = 3431 Total Watts = 4500 Total Area = 20765 CHECK Lighting criteria in 415.1.ABCD have been met. 16. Operation/maintenance manual will be provided to owner.(102.1) -------------------------------------------------------------------------