BLOWER DOOR TEST FORM
House Infiltration Vest Cerifsicadon
PrescriPtive and PeriOrmance Method
SE j
Permit 4: [ � (o - O 1 0�
n, a , F
v,,:^ e L,,
�_Aew construction - Con, Plete
51- C-,6e , FL 3 `Fes
( ) Erisi:ing -Aiter Additson
House Infiltration Test Results SLC Climate Zone 2
CFM (50) Q -}
Test Date:
Volume= i l ll—
AcH (so) = cFM (so) x 60 /volume = ___ 6 t (_
Me hanical Ventilatlan requited less than 3 ^,CH
Passing results must be & ACI-1 (50) or less (Pass
( ) Fail
FBC, Energy
The building or dwelling unit shall betested and verified as having an air leakage rate of not exceeding 7 air changes per
hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall he conducted with a
blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (9) or (i) or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be penormed at anytime after creation of all penetrations of the building
thermal envelope.
FSC, Residential
Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
Pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
Testing Companv
Company Name: Pro -Duct Services
Address: 1915 P.io Vista Drive, Ft. Pierce, FL 34949
I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accordance with Section R402.4.1.2 Climate %one 2.
Signature:
Printed Name: Martin Klein
License/Certification #: 5061633