Loading...
HomeMy WebLinkAboutUpdated Energy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method ProjectName: MIRIAM SUE MURRELL BuilderName: Street: 161 BE SERENATA COURT Permit Office: city, State, Zip: PORT ST. LUCIE , FL, PermitNumber: Owner: MIRIAM SUE MURRELL Jurisdiction: Designi-ocation: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing Addition 9. Wall Types (582.1 sqft.) Insulation Area a. Frame -Wood, Exterior R=13.0 582.08 ft2 2. Single family or multiple family Single-family b. N/A R= ft' 3. Number of units, if multiple family i c. N/A R= ft2 4. Number of Bedrooms(Bedrms In Addition) 0(0) d. N/A 10.Ceiling Types (256.0 sqft,) R= ft2 Insulation Area 5. Is this a worst case? No a.Cathedral/SingleAssembly(Unvented) R=30.0 256.00 ft' 6. Conditioned floor area above grade (ft) 256 b. N/A R= ft2 ft, c. NIA R= Conditioned floor area belowgrade(W) 0 11. Ducts R ft2 7. Windows(36.0 sqft.) Description Area a. U -Factor: SgI, U=0.44 20.00 ft' SHGC: SHGC=0.25 12. Cooling systems kBtu/hr Efficiency' b. U -Factor: SgI, U=0.34 16.0oft2 a. Central Unit 12.0 SEER:19.00 SHGC: SHGC=0.23 c. U -Factor: N/A ft2 , SHGC: 13. Heating systems kBtumr Efficiency d. U -Factor: N/A ft2 a. Electric Heat Pump 12.0 HSPF:9.50 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. 14. Hot water systems -Nonerequired Area Weighted Average SHGC: 0,241 A Cap: NIA 8. Floor Types (256.0 sqft,) Insulation Area a. EF: 0.000 a. Slab -On -Grade Edgelnsulalion R=0.0 256.00 ft2 b. Conservation features b. NIA R= ft2 c. N/A R= ft' 15. Credits Pstat Total Proposed Modified Loads: 8.48 PASS Glass/Floor Area: 0.141 Total Baseline Loads: 11.84 I hereby certify that the plans and specifications covered by Review of the plans and qNF wr4Z this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: ___ Before construction is completed DATE: _- this building will be inspected for compliance with Section 553.908 ° _T2�-'2��d. I hereby certify that this building, as designed, is in compliance Florida Statutes. COC WF with the Florida E ergy Code, OWNER/A EN ._ oq�BUILDING OFFICIAL --------.-- DATE: --.- -- DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with 11402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 7/21/20209:02 AM EnergyGauge®USA 6.0.02(Rev.1)- RaRes2017 FBC 6th Edition (2017) Compliant Software Pagel of FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT 7/21/2020 9:02 AM EnergyGauge® USA 6.0.02 (Rev.1)- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 PROJECT Title: MIRIAM SUE MURRELL Bedrooms: 0 Address Type: Street Address Building Type: User ConditionedArea: 256 Lot# OwnerName: MIRIAM SUE MURRELL Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: No PlatBook: BuilderName: RotaleAngie: 0 Street: 161 SE SERENATA CO Permit Office: CrossVentilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: PORT ST. LUCIE , FamilyType: Single-family FL, New/Existing: Addition Comment: CLIMATE / Design Temp Int Design Temp Heating Design DailyTemp V DesignLocation TMY Site 97.5% 2.5% Winter Summer DegreeDays Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 256 2406.4 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 ENCLOSED ROOM 256 2406.4 No 0 1 Yes Yes Yes FLOORS _FloorType_ Space_ Perimeter R -Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulation ENOLOSEDROO 55ft 0 256 ft' _-__ 0 1 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor, Tested Tested Insul. (deg) 1 Gableorshed Compositionshingles 270 ft' 42W Medium N 0.5 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 No attic Unvented 0 256 ft' N N CEILING # Ceiling Type Space R -Value Ins Type Area Framing Frac Truss Type 1 Cathedral/SingleAssembly(UnveriaKLOSED ROO 30 Blown 256 ft' 0.1 Wood 7/21/2020 9:02 AM EnergyGauge® USA 6.0.02 (Rev.1)- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 7/21/2020 9:02 AM EnergyGauge0 USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 WALLS / V _Drat _ 1 N _ 2 E _ 3 S 4 W Adjacent —_7�_... Wz1Uype__.-- Exterior Frame -Wood Exterior Frame -Wood Exterior Frame -Wood Exterior Frame -Wood Space Cavity Width Height p R V A a Ft Au--_ Ft_Jn---_Arae_—_—R,Lalue__FracUon ENCLOSED 13 7 0 10 7 74.1 ft' ENCLOSED 13 16 0 10 7 169.3 ft' ENCLOSED 13 16 0 10 7 169.3 ft2 ENCLOSED 13 16 0 10 7 169.3 ft2 Sheathing Framing Solar Below nnmr Grzde°lo—. 0 0.25 0.6 0 0 0.25 0.6 0 0 0.25 0.6 0 0 0.25 0.6 0 WINDOWS Orientation shown lathe entered. Proposed orientation. V# Wall Ornt ID Frame Panes Overhang NFRC LI -Factor SH_GC ImpArea Depth_ Separation Int Shade Screening 1 2 S 3 Vinyl Low-ESingle N 1 Metal Low-ESingle Yes 0.34 0.23 Y 16.0 ft2 2ft01n Yes 0.44 0.25 Y 20.0 ft2 2 ft 0 in 1ft4 in None 1 ft 4 in Drapes/blinds None Exterior 1 INFILTRATION # Scope Method SLA CFM 50 ELA Eq LA ACH ACH 50 1 Wholehouse ProposedACH(50) .000299 200.5 11.01 20.7 .1104 5 HEATING SYSTEM System Type Speed_ Efficiency Capacity Block Ducts ___# 1 ElectricHeatPump/Supplemen _Subtype Split Single HSPF:9.5 12 kBtu/hr 1 Ductless COOLING SYSTEM # System Type HR_ Block_ Subtype Subtype Efficiency Capacity Air Flow —SHR - Ducts 1 Central Unit/Supplementalfora Split Single SEER: 19 12 kBtu/hr cfm 0.7 1 Ductless SOLAR HOT WATER SYSTEM FSEC Cert # CompanyName System Model# CollectorModel# Collector Storage Area Volume FEF 7/21/2020 9:02 AM EnergyGauge0 USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT 7/21/20209:02 AM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4of4 TEMPERATURES Programable[[T]]hermostat::Jan Crr eilingFans:Coo Heating [X] Jan [`x� ]iY Feb Feb ((]] fX] Mar Mar € May jM:yjXjj Jun jr[` j1Jj Jul 44 jjjj Aug ji4 jj Sep [[ff OctOct j[Xjj Nov Dec jjXjj Venting II 11 Jan I L 1 Feb 1 IIX1l Mar Apr [ ] [ ] lXl [X] lX� [X� [X] Nov [ j Dec ThermostatSchedule: HERS 2006 Reference Hours ScheduleType 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 fib 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8lbs/s .ft. 0 ft2 0 ft 0.3 ENCLOSED ROOM 7/21/20209:02 AM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4of4