HomeMy WebLinkAboutUpdated Energy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
ProjectName: MIRIAM SUE MURRELL
BuilderName:
Street: 161 BE SERENATA COURT
Permit Office:
city, State, Zip: PORT ST. LUCIE , FL,
PermitNumber:
Owner: MIRIAM SUE MURRELL
Jurisdiction:
Designi-ocation: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing Addition
9. Wall Types (582.1 sqft.)
Insulation Area
a. Frame -Wood, Exterior
R=13.0 582.08 ft2
2. Single family or multiple family Single-family
b. N/A
R= ft'
3. Number of units, if multiple family i
c. N/A
R= ft2
4. Number of Bedrooms(Bedrms In Addition) 0(0)
d. N/A
10.Ceiling Types (256.0 sqft,)
R= ft2
Insulation Area
5. Is this a worst case? No
a.Cathedral/SingleAssembly(Unvented)
R=30.0 256.00 ft'
6. Conditioned floor area above grade (ft) 256
b. N/A
R= ft2
ft,
c. NIA
R=
Conditioned floor area belowgrade(W) 0
11. Ducts
R ft2
7. Windows(36.0 sqft.) Description Area
a. U -Factor: SgI, U=0.44 20.00 ft'
SHGC: SHGC=0.25
12. Cooling systems
kBtu/hr Efficiency'
b. U -Factor: SgI, U=0.34 16.0oft2
a. Central Unit
12.0 SEER:19.00
SHGC: SHGC=0.23
c. U -Factor: N/A ft2
,
SHGC:
13. Heating systems
kBtumr Efficiency
d. U -Factor: N/A ft2
a. Electric Heat Pump
12.0 HSPF:9.50
SHGC:
Area Weighted Average Overhang Depth: 2.000 ft.
14. Hot water systems -Nonerequired
Area Weighted Average SHGC: 0,241
A
Cap: NIA
8. Floor Types (256.0 sqft,) Insulation Area
a.
EF: 0.000
a. Slab -On -Grade Edgelnsulalion R=0.0 256.00 ft2
b. Conservation features
b. NIA R= ft2
c. N/A R= ft'
15. Credits
Pstat
Total Proposed Modified Loads: 8.48
PASS
Glass/Floor Area: 0.141
Total Baseline Loads: 11.84
I hereby certify that the plans and specifications covered by
Review of the plans and
qNF wr4Z
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY: ___
Before construction is completed
DATE: _-
this building will be inspected for
compliance with Section 553.908
°
_T2�-'2��d.
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
COC
WF
with the Florida E ergy Code,
OWNER/A EN ._ oq�BUILDING
OFFICIAL --------.--
DATE: --.- --
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with 11402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
7/21/20209:02 AM EnergyGauge®USA 6.0.02(Rev.1)- RaRes2017 FBC 6th Edition (2017) Compliant Software Pagel of
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
7/21/2020 9:02 AM EnergyGauge® USA 6.0.02 (Rev.1)- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
PROJECT
Title:
MIRIAM SUE MURRELL Bedrooms: 0
Address Type: Street Address
Building Type:
User
ConditionedArea: 256
Lot#
OwnerName:
MIRIAM SUE MURRELL Total Stories: 1
Block/Subdivision:
#of Units:
1
Worst Case: No
PlatBook:
BuilderName:
RotaleAngie: 0
Street: 161 SE SERENATA CO
Permit Office:
CrossVentilation: No
County: St. Lucie
Jurisdiction:
Whole House Fan: No
City, State, Zip: PORT ST. LUCIE ,
FamilyType:
Single-family
FL,
New/Existing:
Addition
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating Design DailyTemp
V DesignLocation
TMY Site 97.5% 2.5%
Winter Summer DegreeDays Moisture Range
FL, Fort Pierce
FL_VERO_BEACH_MUNI 39 90
70
75 299 62 Low
BLOCKS
Number
Name
Area Volume
1
Entire House
256 2406.4
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms Infil ID Finished Cooled Heated
1
ENCLOSED ROOM 256 2406.4 No 0
1 Yes Yes Yes
FLOORS
_FloorType_
Space_ Perimeter R -Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulation ENOLOSEDROO 55ft 0
256 ft'
_-__ 0 1 0
ROOF
Roof Gable Roof
Rad
Solar SA Emitt Emitt Deck Pitch
V #
Type
Materials Area Area Color
Barr
Absor, Tested Tested Insul. (deg)
1
Gableorshed
Compositionshingles 270 ft' 42W Medium
N
0.5 No 0.9 No 0 18.4
ATTIC
/
V
#
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
No attic
Unvented 0 256 ft'
N N
CEILING
#
Ceiling Type
Space R -Value Ins Type
Area Framing Frac Truss Type
1
Cathedral/SingleAssembly(UnveriaKLOSED ROO 30 Blown
256 ft' 0.1 Wood
7/21/2020 9:02 AM EnergyGauge® USA 6.0.02 (Rev.1)- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
7/21/2020 9:02 AM EnergyGauge0 USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4
WALLS
/
V _Drat
_ 1 N
_ 2 E
_ 3 S
4 W
Adjacent
—_7�_... Wz1Uype__.--
Exterior Frame -Wood
Exterior Frame -Wood
Exterior Frame -Wood
Exterior Frame -Wood
Space Cavity Width Height
p R V A a Ft Au--_ Ft_Jn---_Arae_—_—R,Lalue__FracUon
ENCLOSED 13 7 0 10 7 74.1 ft'
ENCLOSED 13 16 0 10 7 169.3 ft'
ENCLOSED 13 16 0 10 7 169.3 ft2
ENCLOSED 13 16 0 10 7 169.3 ft2
Sheathing Framing Solar Below
nnmr Grzde°lo—.
0 0.25 0.6 0
0 0.25 0.6 0
0 0.25 0.6 0
0 0.25 0.6 0
WINDOWS
Orientation shown lathe entered. Proposed orientation.
V#
Wall
Ornt ID Frame Panes
Overhang
NFRC LI -Factor SH_GC ImpArea Depth_ Separation Int Shade
Screening
1
2
S 3 Vinyl Low-ESingle
N 1 Metal Low-ESingle
Yes 0.34 0.23 Y 16.0 ft2 2ft01n
Yes 0.44 0.25 Y 20.0 ft2 2 ft 0 in
1ft4 in None
1 ft 4 in Drapes/blinds
None
Exterior 1
INFILTRATION
# Scope
Method
SLA CFM 50 ELA Eq LA ACH
ACH 50
1 Wholehouse ProposedACH(50)
.000299 200.5 11.01 20.7 .1104
5
HEATING SYSTEM
System Type
Speed_ Efficiency Capacity
Block
Ducts
___#
1
ElectricHeatPump/Supplemen
_Subtype
Split Single HSPF:9.5 12 kBtu/hr
1
Ductless
COOLING SYSTEM
#
System Type
HR_ Block_
Subtype Subtype Efficiency Capacity Air Flow —SHR -
Ducts
1
Central Unit/Supplementalfora
Split Single SEER: 19 12 kBtu/hr
cfm 0.7 1
Ductless
SOLAR HOT WATER SYSTEM
FSEC
Cert # CompanyName
System Model# CollectorModel#
Collector Storage
Area Volume
FEF
7/21/2020 9:02 AM EnergyGauge0 USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
7/21/20209:02 AM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4of4
TEMPERATURES
Programable[[T]]hermostat::Jan
Crr eilingFans:Coo
Heating [X] Jan [`x�
]iY Feb
Feb
((]]
fX] Mar Mar
€
May
jM:yjXjj
Jun
jr[` j1Jj
Jul
44 jjjj
Aug
ji4 jj
Sep
[[ff OctOct
j[Xjj Nov
Dec
jjXjj
Venting II 11 Jan I
L
1 Feb
1
IIX1l Mar
Apr
[
]
[ ]
lXl
[X]
lX�
[X�
[X] Nov
[ j Dec
ThermostatSchedule: HERS 2006
Reference
Hours
ScheduleType
1
2
3
4
5
6
7
8
9
10
11
12
Cooling(WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling(WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
fib
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating(WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8lbs/s .ft.
0 ft2
0 ft
0.3
ENCLOSED
ROOM
7/21/20209:02 AM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4of4